Heat Transfer Analysis of Corrugated Plate Heat Exchanger over Coil Type Heat Exchanger: A Review
Mr. Mohd. Sohail Ansari
Department of Mechanical Engineering, G.H. Raisoni Academy of Engg. & Tech, 37-39/1, Shraddha Park Hingna Wadi Link Road, Nagpur, Maharashtra- 440016 India
Mr. Prashant Mishra
Department of Mechanical Engineering, G.H. Raisoni Academy of Engg. & Tech, 37-39/1, Shraddha Park Hingna Wadi Link Road, Nagpur, Maharashtra- 440016 India
Mr. Kunal Gaikwad
Department of Mechanical Engineering, G.H. Raisoni Academy of Engg. & Tech, 37-39/1, Shraddha Park Hingna Wadi Link Road, Nagpur, Maharashtra- 440016 India
Guided By: Prof. P.N. Awachat
Department of Mechanical Engineering, G.H. Raisoni Academy of Engg. & Tech, 37-39/1, Shraddha Park Hingna Wadi Link Road, Nagpur, Maharashtra- 440016 India
AbstractCompared to coil type heat exchanger, corrugated plate heat exchangers (PHE) have larger heat transfer surface. Due to the presence of corrugations on plates of PHE, turbulence level is increased and so the heat transfer. In this study, experiment of heat transfer phenomenon was carried out at bottle washer of beverage making industry. This typical bottle washer which has coil type heat exchanger consumes more amounts of energy. Study shows that employing PHE instead of coil type heat exchanger saves considerable amount of energy.
Keywords Coil Heat transfer System, Furnace oil yield, Bottle washer, Plate Heat Exchanger (PHE) .
-
INTRODUCTION
Experiment was performed at bottle washer which is used for rinsing and cleaning of bottles. For this purpose heated caustic solution is used. Heating of caustic solution inside bottle washer is done by coil type heat exchanger. Focus is made to reduce the quantity of steam utilized in bottle washing process. Phenomenon of heating the solution depends on the area expose to heat transfer as well as heat transfer rate of coil type heat exchanger. Study of PHE shows that its effectiveness is much higher than convectional coil system .Configuration of corrugated plates of PHE leads to increase in area expose to heat transfer which causes increased heat transfer rate .When PHE is incorporated instead of coil system, steam consumption is reduced and there is a significant increase in efficiency of the process.
-
Bottle Washer Unit
The bottle washer unit consists of five compartments namely pre-rinse, soak1, soak2, again pre-rinse and final rinse out of which Soak1 and Soak2 have capacity of 28000 L and 8000 L of storage. This soak tanks contains caustic solution which is used for cleaning of bottles. Bottles from market are first passed through pre-rinsed section for hydrowash by the rotary jets. Steam from boiler passes through coils inside the soak tanks. The steam enters the soak through the coils which are
nothing but the hollow pipe of metallic material. As this steam passes through the coil type heat exchanger, energy and heat of steam is rejected to the surrounding. The surrounding is a mixture of water and caustic soda solution. The caustic solution at ambient temperature of 280C is made to heat up upto 650C which is the required temperature. The steam from other end of coil comes out as condensate which is further utilized and fed into feed water tank.
-
Coil Heat Transfer system
The system is placed inside bottle washer. Its purpose is to heat the caustic solution from ambient temperature to to around 650C. In this steam generated from boiler is passed through separate coils which are surrounded by caustic solution. Heat rejected by steam is gained by caustic solution. The principle of heating caustic solution is based on the fact that water becomes lighter and comes to the top when it is heated up. The caustic solution which is in contact with coils (carrying steam inside) gets heated up first and comes to the top. This process continues till remaining solution acquires heat. The area exposed to heat transfer is the surface area of the pipe.
-
Plate Heat Exchanger (PHE)
The plate heat exchanger (PHE) is a specialized design well suited to transfer heat between medium and low-pressure fluids. Stainless steel is a commonly used metal for the plates because of its ability to withstand high temperatures, its strength, and its corrosion resistance. The plates are often spaced by rubber sealing gaskets which are cemented into a section around the edge of the plates [9].The plates are pressed to form troughs at right angles to the direction of flow of the liquid which runs through the channels in the heat exchanger. These troughs are arranged so that they interlink with the other plates which forms the channel with gaps of 1.31.5 mm between the plates. Arrangement of PHE & Flow through
PHE and construction of plate is shown in figure [2].
Fig.1. Various Part of Plate Heat Exchanger
The plates produce an extremely large surface area, which allows for the fastest possible transfer. Making each chamber thin ensures that the majority of the volume of the liquid contacts the plate, again aiding exchange. The troughs also create and maintain a turbulent flow in the liquid to maximize heat transfer in the exchanger. A high degree of turbulence can be obtained at low flow rates and high heat transfer coefficient can then be achieved. A plate heat exchanger consists of a series of thin, corrugated plates which are mentioned above. These plates are gasketed, welded or brazed together depending on the application of the heat exchanger. The plates are compressed together in a rigid frame to form an arrangement of parallel flow channels with alternating hot and cold fluids.
-
Physical Parameters Affecting Plate Heat Exchanger
The six most important parameters are as follows:
-
The amount of heat to be transferred (heat load).
-
The inlet and outlet temperatures on the primary and secondary sides.
-
The maximum allowable pressure drop on the primary and secondary sides.
-
The maximum operating temperature.
-
The maximum operating pressure.
-
The flow rate on the primary and secondary sides.
Temperature Program:
This means the inlet and outlet temperatures of both media in the heat exchanger.
Heat Load:
Disregarding heat losses to the atmosphere, which are negligible, the heat lost (heat load) by one side of a plate heat exchanger is equal to the heat gained by the other. The heat load (P) is expressed in kW or kcal/h.
Logarithmic Mean Temperature Difference:
Logarithmic mean temperature difference (LMTD) is the effective driving force in the heat exchanger.
Density:
Density () is the mass per unit volume and is expressed in kg/m3 or kg/dm3.
Flow Rate:
This can be expressed in two different terms, either by weight or by volume. The units of flow by weight are in kg/s or kg/h, the units of flow by volume in m3/h or l/min. To convert units of volume into units of weight, it is necessary to multiply the volume flow by the density.
Pressure Drop:
Pressure drop (p) is in direct relationship to the size of the plate heat exchanger. If it is possible to increase the allowable pressure drop, and incidentally accept higher pumping costs, then the heat exchanger will be smaller and less expensive. As a guide, allowable pressure drops between 20 and 100 kPa are accepted as normal for water/water duties.
Specific Heat:
Specific heat (cp) is the amount of energy required to raise 1 kg of a substance by one degree centigrde. The specific heat of water at 20°C is 4.182 kJ/kg °C or 1.0 kcal/kg °C.
Viscosity:
Viscosity is a measure of the ease of flow of a liquid. The lower the viscosity, the more easily it flows. Viscosity is expressed in centipoises (cP) or centistokes (cSt).
Overall Heat Transfer Coefficient:
Overall heat transfer coefficient (U) is a measure of the resistance to heat flow, made up of the resistances caused by the plate material, amount of fouling, nature of the fluids and type of exchanger used. Overall heat transfer coefficient is expressed as W/m2 °C or kcal/h, m2 °C.
Operating Principle of Plate Heat Exchanger
-
Channels are formed between the plates & corner ports are arranged so that the two media flow through alternate channels.
-
The heat is transferred through the thin plate between the channels, and complete counter current flow is created for highest possible efficiency. No intermixing of the media or leakage to the surroundings will take place as gaskets around the edges of the plates seal the unit. Operating Principle of Plate Heat Exchanger.
Fluid Flow in Plate Heat Exchanger
Figure 2, illustrates the nature of fluid flow through the plate heat exchanger. The primary and secondary fluids flow in opposite directions on either side of the plates. Water flow and circuiting are controlled by the placement of the plate gaskets. By varying the position of the gasket, water can be channelled over a plate or past it. Gaskets are installed in such a way that a gasket failure cannot result in a mixing of the fluids. In addition, the outer circumference of all gaskets is exposed to
the atmosphere. As a result, should a leak occur, a visual indication is provided.
Fig.3. Fluid flow in plate heat exchanger
Heat transfer in Plate Heat Exchanger
-
Conduction
Energy is transferred between solids or stationary fluids by the movement of atoms or molecules.
Heat transfer by conduction within chevron plates during whole process of heat transfer in chevron plates heat exchanger.
-
Convection
-
-
Energy is transferred by mixing part of a medium with another part.
Heat transfer takes between molecules of water in chevron plate heat exchanger.
-
-
CALCULATIONS AND RESULTS
-
Efficiency of the boiler:-
In determining the boiler efficiency, rate of steam produced per hour is taken as output whereas energy liberated from burning of fuel is taken as input.
= 81.98 %
In case of PHE, the area exposed to heat transfer and the heat transfer rate are much more than that of the coil type heat exchanger. Therefore replacing the coil system with PHE leads to raise the bottle washer process efficiency up to 84%.
Now by performing reverse calculations and putting efficiency equal to 84% in eqn 2, new steam consumption is assumed as x and thus new steam consumption rate was found out to be reduced by 34% Further to calculate amount of fuel saved (i.e. furnace oil) in boiler due to reduction in steam consumption,
Reduction in furnace oil considering boiler efficiency =
saving in steam × enthalpy of steam at working pressure × B
Calorific value of fuel
Thus furnace oil consumption was found out to be reduced by 23%.
-
-
COMPARISON OF CONSUMPTION OF FURNACE OIL AND STEAM IN COIL HEAT EXCHANGER VS. PHE
120
100
Coil Heat Exchanger
PHE
80
60
40
20
0
Furnace Oil (Kg/hr)
Fig. 5. Consumption of furnace oil
-
Efficiency of the bottle washing process considering coil system:-
In calculating bottle washer process efficiency by coil type heat exchanger, the amount of caustic solution being heated up from 28o C to 65oC is taken as output and the amount of steam utilized is taken as input. Here the heat rejected by steam is gained by caustic solution. The efficiency of process is found out to be 56.05%.
= 56.05 %
1400
1200
1000
800
600
400
200
0
Coil Heat Exchanger
PHE
Steam (Kg/hr)
Fig.6. Consumption of steam
Thus the furnace oil yield is increased i.e. liters of beverage produced is more at the expense of reduced furnace oil ,which will further lead to increased the overall efficiency of the plant.
-
-
CONCLUSIONS
Heat transfer analysis of PHE shows that as the effectiveness of PHE is more than that of the coil type heat exchanger ,more effective heat transfer takes place with reduced amount of energy inputs(steam and fuel ).
REFERENCES
-
N. Srihari- Transient response of plate heat exchangers considering effect of flow maldistribution.
-
Jos_e M. Pinto – Optimal configuration design for plate heat exchangers.
-
Jorge A.W. Gut- Modeling of plate heat exchangers with generalized configurations.
-
Nicolas Galanis-Heat transfer and fluid flow in a plate heat exchanger. Part II: Assessment of laminar and two-equation turbulent models.
-
Xiao-Hong Han, Li-Qi Cui, Shao-Jie Chen, Guang-Ming Chen, Qin Wang- A numerical and experimental study of chevron, corrugated-plate heat exchangers.
-
Harika Sammeta, Kalaichelvi Ponnusamy- Effectiveness charts for counter flow corrugated plate heat exchanger.
-
Sadik Kakaç and Hongtan Liu .-Heat Exchangers: Selection, Rating and Thermal Design.
-
P M V Subbarao- Creators of Turbulent Flows at Low Reynolds Numbers.
-
Akash Pandey- Performance analysis of compact heat exchanger.
-
Focke W.W, Zachariades J., Olivier I. , 1985 The effect of the corrugation inclination angle on the thermo hydraulic performance of plate heat exchangers, Int. J. Heat Mass Transfer 28 [8], pp 14691479.
-
Mehrabian M.A , Poulter R., 2000 Hydrodynamics and thermal characteristics of corrugated channels: computational approach, Applied Mathematical Modelling 24 ,pp 343-364
-
Metwally H.M. , Manglik R.M. ,2004 Enhanced heat transfer due to curvature-induce lateral vortices in laminar flows in sinusoidal corrugated-plate channels, International Journal of Heat and Mass Transfer 47, pp 22832292
-
Gradeck M. , Hoareau B., Lebouche M.,2005 Local analysis of heat transfer inside corrugated channel, International Journal of Heat and Mass Transfer 48 ,pp19091915
-
Bobbili Prabhakara Rao , Sunden Bengt , Das Sarit K.,2006 An experimental investigation of the port flow maldistribution in small and large plate package heat exchangers, Applied Thermal Engineering 26 ,pp 19191926
-
Garc´a-Cascales J.R., Vera-Garc´a F., Corberan-Salvador J.M., Gonzalvez- Macia J. , 2007 Assessment of boiling and condensation heat transfer correlations in the modelling of plate heat exchangers, International Journal of Refrigeration 30 ,pp 1029-10.
-
Lin J.H. , Huang C.Y., Su C.C., 2007 Dimensional analysis for the heat transfer characteristics in the corrugated channels of plate heat exchangers, International Communications in Heat and Mass Transfer 34 ,pp 304312
-
Zhi-jian LUAN, Guan-min ZHANG, Mao-cheng TIAN, Ming-xiu FAN ,2008 Flow resistance and heat transfer characteristics of a new-type plate heat exchanger, Journal of Hydrodynamics 20 ,pp 524-529
-
Warnakulasuriya F.S.K, Worek W.M.,2008, Heat transfer and pressure drop properties of high viscous solutions in plate heat exchangers, International Journal of Heat and Mass Transfer 51
,pp 5267.
-
Tsai Ying-Chi, Liu Fung-Bao , Shen Po-Tsun, 2009
Investigations of the pressure drop and flow distribution in a chevron-type plate heat exchanger, International Communications in Heat and Mass Transfer 36 ,pp 574578