- Open Access
- Total Downloads : 454
- Authors : P. D. Yadav, M. J. Patil
- Paper ID : IJERTV3IS051378
- Volume & Issue : Volume 03, Issue 05 (May 2014)
- Published (First Online): 24-05-2014
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
A Parametric Study of Hybrid (Adhesive and Bolted) Single Lap Joints
-
P. D. Yadav, (2) Prof. Mr. M. J. Patil
(1)M.Tech, Mechanical,Bharati Vidyapeeth College of Engineering,Pune(India)
-
Prof. Department of Mechanical Engineering, Bharti Vidyapeeth College of Engineering, Pune(India)
Abstract: Hybrid joints are a combination of adhesive bonding and mechanical fastening and are known to combine the advantages of both joint types. In this paper, we evaluate the mechanical behavior of a representative structure consisting of composite material and metal under tensile load. We have considered the properties of both bolted and adhesive joint. And it is believed that the adhesive layer between bolted lap joint results in a two stage failure of the joint. Hence a modified joint is obtained with increased strength. . In the present study, the influence of the base material, bolt geometry, and adhesive on tensile shear strength was assessed.
Keywords- Hybrid joint, Composite joint, lap joint in automobiles
-
INTRODUCTION
Joint design in the composite structures is a very important consideration because improper design may lead to overweight or defective structures. The joining of composite materials has traditionally been achieved by mechanical fastening or adhesive bonding in this technique the important idea how we can get high ability to load transfer hence composite materials can be two or more than two materials in similar or dissimilar materials the purpose of composite is to get high properties of materials and to improve the ability of load transfer [7]
Adhesive bonding does not require holes and distributes the load over a larger area than mechanical joints; however, adhesive bonding joints are very sensitive to the surface treatment of the material, service temperature, humidity and other environmental conditions.
Figure1.1 Sketch of hybrid (adhesive/bolted) joint.
Hybrid joint is a process that makes use of two different joining techniques. They, in principle, bring together the advantages of two different techniques. In hybrid joining two or more joining operations are carried out either simultaneously or sequentially, leading to enhanced properties of the joint. Hybrid joining is used in the assembly of modern light weight automotive and commercial vehicle structures. Combining adhesive bonding with mechanical joining can offer advantages in terms of process ability and load bearing capacity.
Any number of papers can easily be found about mechanical joints that use bolts, rivets, or pins. These papers consider various approaches, including Design of Experiments methodology [4] and the 3-dimensional finite element method [9,10] and/or test [2,5]
We are going to use Bolted joint as mechanical joining and adhesives to prepare a hybrid joint that will be useful for automotive applications. Mechanical Joints (bolted joints) often fails under fatigue loading and adhesive alone often peels off. So, to prevent adhesive peel action we are using adhesives with bolts which in result provide more strength of the joint and avoid failure.
-
LITERATURE REVIEW
M. Luci [1] investigated aluminum single lap adhesively bonded joints. Maximal strength of joint might be reached if optimal overlap length of joint is applied. The influence of the adherend elastic/plastic behavior is very significant for joint strength. It is important to note that final adherend roughness influenced with joint preparation procedure could affect joint strength.
Patel Vijaykumar V [3] in this paper presents about optimization of the automotive chassis with constraints of maximum shear stress, equivalent stress and deflection of chassis under maximum load.Structural systems like the chassis can be easily analyzed using the finite element techniques.
-
Manalo [6] in this paper presents about the behavior of an innovative hybrid Fibre Reinforced Polymer (FRP) composite with bolted joints was investigated. Coupons and full-size specimens were tested to determine the effect of applied bolt torque and the contribution of adhesive bonding on the load capacity and failure mode of the hybrid FRP with bolted joints. The hybrid FRP composite girder with joints
connected using bolts and epoxy adhesives exhibited the same strength and stiffness as the girder without joints while bolting alone resulted to a beam with only 65% of the stiffness of those without joints.
-
Barut [8] In his study, a semi-analytical method was developed for the coupled in-plane and bending analysis of composite bondedbolted single-lap hybrid joints.. The following particular cases were investigated in this study: The joint has no initial defects, no debonding occurs, and all loads are transferred by the adhesive bond, The adhesive bond is partially debonded, resulting in the bolt transferring some of the load.
-
-
-
DESIGN OF EXPERIMENTS AND ANOVA
-
The experimental setup, the machine required for experimentation was STAR TENSILE TESTING MACHINE. The lap joints are prepared. One of the ends of the plate was held fixed and other end subjected to tension loading by the load cell at 5mm/min speed.
Figure 3.1Star Tensile Testing Machine
The following factors are used for experimentation:
-
Base Metal (Aluminium and Composite)
-
Adhesive type (H3151 & E120HP)
-
No of bolts (Single or Double bolted)
A. Number of Observations:
The 2k factorial design is used and there are three independent variables in this experiment. Meaning three variables are varied at 2 levels i.e. low and high. Hence the minimum number of observations are 23 i.e. 8.
Parameters
Nomenclature
High(+)
Low(-)
Base
Metal
BM
Al
FRP
Adhesive
A
H3151
E120HP
No of
bolts
NB
2
1
-
EXPERIMENTATION AND DATA COLLECTION
The design is created for an experiment. The data is collected. The experimental factor have some level. For example in the experiment the base metal taken at two levels as mentioned above high abbreviated as +1 and low abbreviated as -1. The runs combined as per the higher and lower levels as shown in the table below :
-
DOE in coded form:
Input Parameters
Run
Factor 1 (BM)
Factor 2 (A)
Factor 3 (NB )
1
Al(+)
H3151 (+)
SINGLE BOLTED (-)
2
FRP(-)
E120HP (-)
DOUBLE BOLTED (+)
3
Al(+)
E120HP (-)
DOUBLE BOLTED (+)
4
FRP(-)
H3151 (+)
SINGLE BOLTED (-)
5
FRP (-)
E120HP(-)
SINGLE BOLTED (-)
6
Al(+)
H3151(+)
DOUBLE BOLTED (+)
7
Al (+)
E120HP (-)
SINGLE BOLTED (-)
8
FRP (-)
H3151(+)
DOUBLE BOLTED (+)
li>
Experimental Results:
Input Parameters
Output Parameters
Ru n
Factor 1
(BM)
Factor 2 (A)
Factor 3 (NB )
UTS (KN) (P)
1
Al(+)
H3151 (+)
SINGLE BOLTED (-)
47.089
2
FRP(-)
E120HP (-)
DOUBLE BOLTED (+)
11.65
3
Al(+)
E120HP (-)
DOUBLE BOLTED (+)
42.885
4
FRP(-)
H3151 (+)
SINGLE BOLTED (-)
13.79
5
FRP (-)
E120HP(-)
SINGLE BOLTED (-)
8.43
6
Al(+)
H3151(+)
DOUBLE BOLTED (+)
47.079
7
Al (+)
E120HP (-)
SINGLE BOLTED (-)
45.72
8
FRP (-)
H3151(+)
DOUBLE BOLTED (+)
18.48
-
-
ANALYSIS OF EXPERIMENTS
-
Mean square or variance (MS or V)
Sum of squares when divided degrees of freedom given mean square or variance. Variance is calculated for all the factors as well as interactions and following ANOVA table is formed.
MS = Sum of square / degree of freedom
Sr. No
Factors
Sum of square
Degree of freedom
Variance of mean square
1
B
2126.26
1
2126.26
2
A
39.3961
1
39.3961
3
N
3.2068
1
3.2068
4
BA
5.4896
1
5.4896
5
BN
14.4587
1
14.4587
6
AN
2.3058
1
2.3058
7
BAN
0.2294
1
0.2294
Final ANOVA table
Sr.No
.
Factor
Sum of square
Degree of
freedom
Variance of mean
square
FO
1
B
2126.26
1
2126.26
757.24
2
A
39.3961
1
39.3961
14.030
3
BN
14.4587
1
14.4587
1.142
4
Pooled
error
11.2316
4
2.8079
From the above table it can be observed that the value of variance ranges from 0.2294 to 2126.26 .which is very wide range to avoid tedious calculations all sum of squares below
Now, in calculation of F ratio, Degree of freedom for numerator = 1
Degree of freedom for denominator =4
There for consulting F distribution table, for 95% level of
5.4896 can be pooled together to form of square due to error(SSerror)
confidence we find that F value is F
0.05,1,4
F limit =7.71 since
Following sources can be pooled together. N+BA+AN+BAN
=3.2068+5.4869+2.3058+0.2294
Pooled error = 11.2316
Mean square or variance for error can be calculated as. MSerror = SSerror/Verror
= 11.2316/4
=2.8079
These pooled figures are removed from their place in ANOVA table and recorded as error factor at the bottom of ANOVA table.
Various tables with Pooled Error
Sr.No.
Factor
Sum of square
Degree of freedom
Variance of mean
square
1
B
2126.26
1
2126.26
2
A
39.3961
1
39.3961
3
BN
14.4587
1
14.4587
4
Pooled
error
11.2316
4
2.8079
-
Calculation for F value
Our main aim in this method of analysis is to see if the signal created by the factor is stronger than the background noise (error).the F test is used to compare two variances.
FO = SSA/Vfactor ÷ SSE/Verror =MSfactor/MSerror
Including this F factor, we form are final ANOVA table as below.
all the F value in the table are lesser than the limiting value of
F ratio.
-
-
REGRESSION ANALYSIS
In many problems there are two or more variables that are related, and it is of interest to model and explore this relationship. in general, suppose that there is a single dependent variables or response y that depends upon k independent or regression variables, for eg, x1,x2,x3.Xk. A mathematical model called a regression model characterizes the relationship between these variable, it is important to express the result of an experiment quantitavely, in terms of an empirical model to facilitate understanding, interpretation, and implementation.
In general, the response variable y may be related to k regressor variable.
The model-
Y= o + 1×1+ 2×2+.. kxk+.
Is called a multiple linear regression model with k regressor variable.
The parameters BJ,J = 0,1k, are called the regression coefficient. this model describes a hyper plane in the k dimensional space regressor variables (xj).the parameter bj represent the expected changing in response y per unit change in xj when all the remaining independent variables xi(I J)are held constant.
-
Multiple line regression model
For the current problem the regression model is in the form Y = o + 1×1+ 2×2+ 3x1x2
Where x1,x2 are the factors A,C respectively,x1x2 represent the interaction between A and C.
-
Calculation of coefficient
In coded form of the equation, coefficient o = the avg values of response value.
N
o = yi/N
i=1
therefore o = 235.123 / 8
= 29.3903
Other coefficients can be calculated by using the effect estimates for corresponding factors interaction.
The effect of particular factor is the difference between the average values of response at the high and low setting of the factor.
i.e. Effect of factor B = yB+-= yB-
= (182.773) / 4 (52.35) / 4
= 45.6932-13.0875
= 32.6057
-
Effect estimation
Final ANNOVA table
Remark
Factor
/Interact ion
Effect estimate
Sum of square
Percentage contributio n
Model
B
32.6057
2126.26
97.0298
Model
A
4.4382
39.3961
1.7978
Model
BN
-2.6887
14.4587
0.6598
Error
N
1.2663
3.2068
0.1463
Error
BA
-1.6567
5.4896
0.2505
Error
AN
1.0737
2.3058
0.1052
Error
BAN
0.3387
0.2294
0.0104
=
2191.3464
Percentage contribution for B = (2126.26/2191.3464)*100
= 97.0298
Now the regression coefficient is exactly one half of the usual effect this is always true for a 2k design. Hence the regression coefficient in equation
can be calculated as below:
1 = ½ (effect estimate for factor B) = 32.6057 / 2
= 16.3028
2= ½ (effect estimate for factor A) = 4.4382 / 2
= 2.2191
3 = ½ (effect estimate for factor BN ) = – 2.6887/ 2
= – 1.3443
-
-
RESULTS AND DISCUSSION
Single Lap Joint 1 Single Lap Joint 2
Single Lap Joint 3 Single Lap Joint 4
Single Lap Joint 5 Single Lap Joint 6
Single Lap Joint 7 Single Lap Joint 8
Aluminium Single Bolted Lap Joint
Result Table (Tensile Testing) Load Cell: 50kn |
|||
Maximum Load (KN) |
Extension at Break (mm) |
Load at Break (N) |
Tensile stress (N/mm2) |
10.09617 |
3.74561 |
9350.61723 |
4.03847 |
Aluminium Double Bolted Lap Joint
Result Table (Tensile Testing) Load Cell: 50kn |
|||
Maximum Load (KN) |
Extension at Break (mm) |
Load at Break (N) |
Tensile stress (N/mm2) |
18.09946 |
5.03029 |
7864.27408 |
7.23978 |
9. CONCLUSIONS
This dissertation work entitled A Parametric Study of Hybrid (Adhesive and Bolted) Single Lap Joints taking input parameters as Base Metal (Aluminium and Composite), Adhesives (H3151 & E120HP) , Number of bolts (Single or Double bolted) & output parameter as Ultimate tensile strength (UTS) of hybrid joints.
Following facts can be concluded:- Final equation in terms of coded forms:
Peak Load = 29.3903 + 16.3028×B + 2.2191×A – 1.3443×BN
-
If we used base metal as Aluminium and Composite (FRP), then Ultimate tensile strength of hybrid joint is increases (97.02%)
-
If we used adhesive as H3151 and E120HP, then the UTS of hybrid joints increases (1.79%)
-
Number of bolts also has less effect on UTS (0.14%),
-
The strength of a hybrid joint is significantly greater than that of simple bolted joints.
10. REFERENCES
-
M. Luci , A. Stoi , J. Kopa , Investigation of aluminum single lap adhesively bonded joints, Journal of Achievements in Materials and Manufacturing Engineering, VOLUME 15 ,ISSUE 1-2,March-April 2006.
-
Peng Hao Wang, The Effects of Adding Attachments in Conventional Composite Hybrid Joints on Tensile Strength, Purdue University Purdue e-Pubs, 12-1-2010.
-
Patel Vijaykumar V , Prof. R. I. Patel, Structural Analysis of Automotive Chassis Frame and Design Modification for Weight Reduction, (IJERT) Vol. 1 Issue 3, May – 2012 ISSN: 2278-0181
-
F. Moroni , A.Pirondi , F.Kleiner, Experimental analysis and comparison of the strength of simple and hybrid structural joints, International Journal of Adhesion & Adhesives 30 (2010) 367379.
-
Jin-Hwe Kweon, Jae-Woo Jung, Tae-Hwan Kim, Jin-Ho Choi, Dong- Hyun Kim, Failure of carbon composite-to-aluminum joints with combined mechanical fastening and adhesive bonding, Composite Structures 75 (2006) 192198.
-
A.C. Manalo, H. Mutsuyoshi , S. Asamoto, Mechanical behavior of hybrid FRP composites with bolted joints, Japan.
-
Gordon Kelly, Load transfer in hybrid (bonded/bolted) composite single-lap joints, Composite Structures 69 (2005) 3543.
-
A. Barut, E. Madenci, Analysis of boltedbonded composite single-lap joints under combined in-plane and transverse loading, Composite Structures 88 (2009) 579594.
-
Vincent Caccese , Jean-Paul Kabche, Keith A. Berube, Analysis of a hybrid composite/metal bolted connection subjected to flexural loading, Composite Structures 81 (2007) 450462.
-
Alda, K., and Sen F, STRESS ANALYSIS OF HYBRID JOINTS USING DIFFERENT MATERIALS VIA 3D-FEM, International
Journal of Engineering & Applied Sciences (IJEAS) Vol.3, Issue 1(2011)90101.
-
Thomas Bus SAE Article, automotive Engineering 2005.