Structural Evaluation of Steel Adapter and Door Type Ring Stiffener in Wind Turbine Tower for Certification

DOI : 10.17577/IJERTV3IS070583

Download Full-Text PDF Cite this Publication

Text Only Version

Structural Evaluation of Steel Adapter and Door Type Ring Stiffener in Wind Turbine Tower for Certification

Chethan M C

    1. ech Student, Department of Mechanical Engineering Vijaya Vittala Institute of Technology, Bangalore, India

      Bharath V G

      Analyst, Kshipra Simulations Bangalore, India

      Harish H

      Assistant Professor, Department of Mechanical Engineering

      Vijaya Vittala Institute of Technology

      Dr. K Kumar

      Additional Manager, Kshipra Simulations Bangalore, India

      Abstract The steel consumption in steel towers for wind turbines in the period 2007-2009 has reach about 3.5 million tonnes of steel. The steel tower is about 20% of the total costs for the wind turbine. Optimization of the steel tower using improved assembling techniques and higher steel grades has targeted savings of about 10% of the tower costs. The first being an investigation for an improvement of the existing flange detail using an available technique from bridge construction to remedy unavoidable imperfections in the joint. The second is proposing a use of the friction type joint to allow higher strains in the shell. Creating a more slender shell is causing needs to review the stability issues and detailing such as door openings and optimizing door stiffening rings by varying plate thickness for structural standpoint. With the light of the above, the present paper demonstrate the static structural evaluation of steel adapter and door type ring stiffener of a wind turbine tower by making use of blend of analytical equations and European standards design codes. Finite element analysis has been effectively utilized for the verification of design calculation for extreme loads as well as for fatigue loads, considering the life of tower to be around 20 years.

      Keywords Steel tower, door type ring stiffener, wind turbine, fatigue loading, optimization, finite element analysis

      1. INTRODUCTION

        When countries around the world were developing into industrialized and developed nations, renewable energy resources were not developed on a large scale. Fossil fuels, such as coal, oil, and natural gas, were abundant and cheap so the worlds wealthy nations grew fast. Today, as the world watches developing nations turn into industrial power-houses; many people are advising that these newly developed nations start with renewable energy resources in order to save money as well as prevent more greenhouse gasses from entering our worlds atmosphere. Therefore, a renewable source, such as wind is becoming a valuable resource around the world[1]. Wind power is the conversion of wind energy into a useful form of energy. A blade acts much like an airplane wing. When the wind blows; a pocket of low-pressure air forms on the downwind side of the blade. The low-pressure air pocket then pulls the blade toward it, causing the rotor to turn. This

        is called lift. The force of the lift is actually much stronger than the wind's force against the front side of the blade, which is called drag. The combination of lift and drag causes the rotor

        to spin like a propeller, and the turning shaft spins a generator to make electricity. The result of over a millennium of windmill development and modern engineering, today's wind turbines are manufactured in a wide range.

        Wind turbines are designed to exploit the wind energy that exists at a location. Aerodynamic modeling is used to determine the optimum tower height, control systems, number of blades and blade shape. Wind turbines convert wind energy to electricity for distribution. Conventional horizontal axis turbines can be divided into three components. The rotor component, which is approximately 20% of the wind turbine cost, includes the blades for converting wind energy to low speed rotational energy. The generator component, which is approximately 34% of the wind turbine cost, includes the electrical generator, the control electronics, and most likely a gearbox. The structural support component, which is approximately 15% of the wind turbine cost, includes the tower and rotor yaw mechanism[2].

        The work done by different researchers on wind turbine development lead the windmill initially developed to mill the food grain into one of the words emerging green energy production method. There are several scientists and researched who worked on the development of wind turbine/wind turbine components. Ring flanges are used in standard connections in tubular structures, especially in towers for wind energy converters. The design of ring flange connections is generally performed by using an approach of Petersen. The load bearing capacity can simply be calculated with the plastic hinge theory considering three failure mechanisms of the critical segment. The flange is considered as a beam and failure modes are defined with plastic hinges developing at different locations. Initially three failure modes were defined by Petersen [3]. Finite element method simulations are used to conduct stress analyses and to optimize the tower geometry [4]. The approaches for fatigue

        analyses used in the wind industry highlights the particular conditions for the design of these dynamically loaded components and the crack initiation life is predicted using methods of damage accumulation which include hysteresis properties of the material involved and stress or strain histories at highly stressed locations [5]. Fatigue analyses of weldments require detailed knowledge of the stress fields in critical regions[6]. The stress information is subsequently used for finding high local stresses where fatigue cracks may initiate and for calculating stress intensity factors and fatigue crack growth [7].

        Meshing: Plane 42 Quad 4noded elements with solid 95 elements is used for meshing as shown in Figure 5.Rated Power of 2000 kW and Hub height of 67 m.

      2. PROBLEM DESCRIPTION

        The present work is carried out with two problem definitions of a wind turbine. In the first case of the study, we need do carry out static structural analysis of a steel adapter of a wind turbine. The analysis includes the pre tensioning of bolts, linear static analysis near the weldment and flange connection regions and to estimate the fatigue life of a steel adapter of a wind turbine tower. In second case of the present work, we have to carry out the structural analysis of a wind turbine tower door by varying the thickness of the ring type door stiffener.

      3. STATIC STUCTURAL ANLYSIS OF STEEL ADAPTERS

        1. Design conditions

          Maximum Moment = 9720 kNm (Due to wind load)

          Axial compression =1900kN

          (Weight of the tower + Nacelle + rotor)

          Steel Adapters are mechanical machine elements used for structural integrity of machine elements commonly found in offshore jackets, decks, oil and gas equipments, pipe line

          Material

          Specification

          Value

          Steel Adapter S355 High grade steel (hot rolled)

          Modulus of Elasticity

          210 GPa

          Poisson Ratio

          0.3

          Density

          7850 kg/mm3

          Bolt

          High grade steel 10.9 grade

          Concrete

          Modulus of Elasticity

          55 GPa

          Poisson Ratio

          0.19

          Density

          250 kg/mm3

          No. of bolts top flange

          24

          No. of bolts bottom

          flange

          96

          Design Code

          DIN Standards

          design, wind tunnels, vacuum tunnels and so on. Similar application is found in renewable wind turbine towers where the tower height is approximately 70-80 m.Here, a single structure of 80M height is impossible without adapter piece. Hence, they play a vital role as integrators.

          TABLE I. MATERIL PROPERTIES

        2. Design considerations[8]

          The tower should sustain a max moment of 1850 kNm

          The tower should sustain a max compressive load = 750kN Modeling: ANSYS Software is considered for geometric modeling as shown in Figure 1 and 3.

          Fig. 1. Model of Steel Adapter Assembly

          The loads considered for Tower Top verification are given below and these loads are given by Hamburg head office Dept of Civil Engineering and Rotor Blades are MZ = 9720 KNm and FY = -1845 KN. Pre-Tensions applied for upper flange and lower flange are 1680 kN and 1380 kN respectively as shown in Figure 2 and 4.

          Fig. 2. Pre-tension loading for upper and lower flange

          Fig. 3. Geometry of steel adapter assembly

          Crushing stress on thread:

          c = (5)

          c = 186.66 MPa

          Bending stress:

          Where:

          b = (6)

          Fig. 4. Bolts area of interest

        3. Design of bolt for flane connection in steel adopters

          From DDHB (Lingaiah) for M42 Bolt size following parameter is taken

          Major Diameter, d=42 mm

          Minor Diameter, d =37.092523 mm Pitch Diameter, d= 39.401924 mm Pitch of thread, p = 4 mm

          Initial stress due to screwing up forces:

          Tensile stress due to stretching of bolts initial tightening load for making a fluid tight joint.

          Fi = 2804.69 × d Fi = 117796.98 N

          If the bolt is not initially stressed, then the maximum safe axial load

          Length of shank of the Bolt, L= 84 mm

          Difference in height between extreme corners of the nut or head, a= 0.25 mm

          Youngs modulus, E=2e5 N/mm² b = 297.61 N/mm²

          Stress due to external forces Tensile stress :

          t = (7)

          Where:

          Applied Load, Fa =750 kN

          Core Area, Ac = (8)

          Ac = 1080.594 mm²

          t = 694.062 N/mm²

          Shear stress :

          = (9)

          Where:

          Area of Bolt, A =

          F=As × (1)

          Where:

          Permissible stress in Bolt Material, =1040 MPa (From DDHB)

          Stress Area of Bolt,

          As = /4 × (d+d/2)² (2) As=1149.06 mm²

          Substitute As& values in above equation F = 1040 ×1149.06

          F= 1195.02 kN

          Torsional Shear stress :

          t = (3)

          Where:

          Frictional Torque, Mt = 0.2 × Fa Applied Load, Fa = 750 KN

          Mt = 150000 N mm

          Torsional Shear Stress t = 555.25 N/ mm²

          Shear stress across threads :

          = (4)

          Where:

          Number of Threads in Engaged, i= 21 mm Width of Thread at root, b= 0.471 mm Shear Stress, = 1036.81 N/mm²

          A = 1385.44 mm² .

          Therefore, = 541.51 N/mm²

          Combined stress :

          Maximum Principal Shear stress,

          max = ½ (10)

          max = 643.166 MPa Maximum principal normal stress,

          max = (11)

          max = 990.197 MPa

          max<t The design is safe.

          Final Load on the Bolt:

          Ff = Fa+ Fi (12)

          Ff = 867.796 KN

          Ff< F

          The design is safe.

          The finite element model consists of 51,504 elements and 66,042 Nodes.Tower-13758 elements, Concrete base – 5760 elements and Adapter- 20736 elements

          Fig. 5. Finite Element Model of steel tower

        4. Boundary conditions

          • Base of the Adapter is fixed in all DOF.

          • Moment and Axial force is applied at pilot node at the centre.

          • Through contact wizard (pilot node option)

            Fig. 6. Bolted connections to ensure the nodal connectivity

        5. Results of steel adopter of wind turbine tower

        Fig. 7. Von mises plot for Tower Adapter bottom flange (radius) Nodal Solution

        Fig. 8. Von mises plot for Tower Adapter bottom weld seem (Nodal Solution)

        Maximum Von Mises stress of 301 MPa has occurred near the steel adapter bottom flange region which indicates the crack initiation of the bottom flange as shown in Figure 7. But Figure 8 shows the maximum Von Mises stress of 202 MPa near the weld seem of the bottom flange region which is well within the limits.

        Fig. 9. Principal Stress Plot-I for Tower Adapter bottom flange (Radius) Nodal Solution

        Fig. 10. Principal Stress Plot-I for Tower Adapter bottom weld seem (Nodal Solution)

        Maximum principal stress of 265 MPa has occurred near the steel adapter bottom flange region which helps in life estimation of the flange due to fatigue as shown in Figure 9. But Figure 10 shows the maximum principal stress of 196 MPa near the weldseem of the bottom flange region which is well within the limits.

      4. STRUCTURAL EVALUATION OF RING TYPE DOOR STIFFENER IN WIND TURBINE TOWER

        1. Preliminary design considerations

          • The foundation of the tower is made fixed rigidly to the ground and bolts are arranged in zigzag fashion.

          • Elliptical door placed in vertical direction helps in utilization of space over circumferential area compared elliptical door placed in horizontal direction and circular door.

          • The mass is assumed to be rigidly attached to the bottom tower door frame.

          • Material of tower door frame is linearly elastic, isotropic and homogeneous.

          • Under any load combination (including any load safety factors), the material of the load bearing structural elements of the tower should remain in the linear elastic region of its stress-strain diagram i.e. no plastic deformation has occurred.

          • Height of Tower is assumed to be 80 meters.

          • Tower and door opening stiffener is assumed to be made out of S355 Steel [10].

          • For thickness above 16 mm and up to 40 mm which is used in our door and tower bottom has allowable yield of 345 MPa.

          • For wind turbine design a material safety factor of

            1.1 is assumed hence Allowable stress is 345/1.1=313 MPa.

          • Modeling: CATIA software is considered for geometric modeling as shown in Figure 11.

            Fig. 11. Geometry of bottom tower with ring type stiffener door frame

            All dimensions are in mm

            Fig. 12. Dimensions of the tower cut out view shows the ring type door stiffener

            Fig. 13. FE Model of ring type door stiffener

            Element type used for discritizing the geometry is higher order tet and hex element as shown in Figure 13, the total number of elements and nodes are 22676 and 133453 respectively.

        2. Boundary conditions for static and fatigue loading

          (A) (B)

          Fig. 14. (A) Static loading (B) Fatigue loading

        3. Results of wind turbine door ring type stiffener

        The dimensioning of a structure or component depends primarily on the type of possible failure. If two or more types of loading occur simultaneously, the combined resulting stresses shall be assessed. As a rule, the ultimate limit state verifications shall be carried out with regard to the material and loading, using the following equivalent stress hypotheses. For ductile materials, the Von-Mises hypothesis, the maximum shear stress hypothesis or maximum shear strain energy hypothesis are used. Other hypotheses, such as the shear stress intensity may be used[9].

        Von mises stress of 380 MPa is observed at the location of stiffener region for first iteration i.e. width of 150 mm and is greater than allowable stress and the Von mises stress reduced to 302 MPa for second iteration i.e. of stiffener width 200 mm and it is well below the allowable stress of 313 MPa as shown in Figure 15 and

        16. Principal stress near the weld connection is averaged for three weld length away from Max stress at weld. Hence the Principal stress for weld is 21.8 MPa.

        Fig. 15. Plot of Von mises result of first iteration

        (

        Fig. 16. Plot of Von mises result of second iteration

        Max rincipal stress in Ring stiffener is 30MPa and for wind turbine fatigue evaluation is done for weld as shown in Figure 17 and 18. Here the weld connection between the ring stiffener and the tower shell is evaluated.

        Fig. 17. Stress plots of fatigue analysis

        Fig. 18. Stress plots of fatigue analysis near weld connection region

        Stress allowable for 1e8 cycles is (90/1.15).(2e6/1e8)^(1/4)= 29.4 N/mm2.

        Wind turbines are designed for specific fatigue cycles. For this wind turbine of 80m height we assume 1E8 Fatigue Cycles. Since weld Principal stress

        21.8 N/mm2 < 29.4 N/mm2 Allowable fatigue stress the design is safe for fatigue.

      5. CONCLUSIONS

The following are the conclusions made from the present work:

  • Steel Adapter bottom flange radius has stress of

    301 MPa which is within the design limits for extreme load case.

  • Principal stress plots are obtained to estimate the life of the flange subjected to fatigue loading. Principal stress value near the steel tower bottom flange fillet radius of 270 MPa subjected to tension has been visualized which is within the fatigue design stress limits and principal stress of 196 MPa is visualized near weld seem region which is well within the limits.

  • Static structural analysis of turbine door frame is carried out and stresses and displacement plots are obtained for two cases and it has been concluded that the stress and displacement value has reduced by increasing the width of the stiffener.

  • Wind turbines are designed for specific fatigue cycles. For this wind turbine of 80m height we assume 1E8 fatigue cycles. Since the weld principal stress is within allowable limits, one can conclude our design is safe for fatigue for 20 years.

REFERENCES

  1. Wind turbines, Coherent Application Threads (CATs) Publication, Boston University.

  2. Cosgrove T. C. Tension Control Bolts, Grade S10T, in Friction Grip Connections, The Steel Construction Institute, Vol 4,2004

  3. Petersen, C.: Stahlbau (Steel Construction), 3. Edition: Vieweg-Verlag. Braunschweig, 1997 [in German]

  4. Eurocode 3: Design of Steel structures; Part 1-1: General rules and rules and buildings. DIN V ENV 1993-1-1,European Committee for Standardisation CEN. Brussels 1992.

  5. Milan Ristow and Ali Muhammad, Fatigue Life of Wind Turbine Structural Components, NAFEMS Seminar, Wiesbaden, Germany, November 10 – 11, 2010.

  6. Thomas Frese and Peter Dalhoff, Fatigue Analysis of Bolted and Welded Joints, NAFEMS Seminar: Fatigue Analysis, Wiesbaden,

    Germany.VDI 2230, February 2003

  7. MustafaAygul, Fatigue Analysis of Welded Structures using the Finite Element Method, Department of Civil and Environmental Engineering, Chalmers University Publication, Gothenburg, Sweden, 2010

  8. ChawinChantharasenawong, PattaramonJongpradist and SasarajLaoharatchapruek, Preliminary Design of 1.5-MW Modular Wind Turbine, 2nd TSME International Conference on Mechanical Engineering Vol. 19-21,Krabi, Thailand, October 2011.

  9. A. Chattopadhyay, G. Glinka, M. El-Zein, J. Qianand R. Formas, Stress analysis and fatigue of welded structures, Online ISSN1878- 6669.

  10. Hani M. Negm and Karam Y. Maalawi,Structural design optimization of wind turbine towers , Journal of Computers and Structures, Volume 74, pp 649-666, 2000.