A Study on Behavior of Structural Systems for Tall Buildings Subjected To Lateral Loads

DOI : 10.17577/IJERTV3IS070984

Download Full-Text PDF Cite this Publication

Text Only Version

A Study on Behavior of Structural Systems for Tall Buildings Subjected To Lateral Loads

Shruti Badami

PG Student Department of Civil Engineering,

Dr. Ambedkar Institute of Technology Bengaluru, India.

M. R. Suresh

Associate professor Department of Civil Engineering,

Dr. Ambedkar Institute of Technology Bengaluru, India.

Abstract This paper describes an investigation has been carried out to examine the most common structural systems that are used for reinforced concrete tall buildings under the action of gravity and wind loads. These systems include Rigid Frame, Shear Wall/Central Core, Wall- Frame Interaction, and Outrigger. The basic modeling technique and assumptions are made by ETABS Program, in 3-D modeling. Design considerations are made according to Indian Standards. This comparative analysis has been aimed to select the optimal structural system for a certain building height. The structural efficiency is measured by the time period, storey displacement, drift, lateral displacement, base shear values and core moments. The recommendations for each structural are based upon limiting the wind drift of the structure, and increasing the lateral stiffness. The achievement of structural system for tall buildings is not an easy task. Whereas building height increases the importance of lateral loads action rises in an accelerating rate. There are two types of lateral loads, wind and seismic loads. Wind load presents the most critical lateral loading for modern tall buildings, which have lightweight skeletons that cause uncomfortable horizontal movements for occupants. Also, wind is not constant either with height or with time and is not uniform over the sides of a building. So, windy weather creates a variety of problems in tall buildings, causing concern for buildings owner and engineers alike. Where, excessive vibration due to this load is a major obstacle in design and construction of a modern tall building. It should be limited to prevent both structural and non-structural damage.

Keywords Tall buildings; structural systems; core moment; and drift control

  1. INTRODUCTION

    The achievement of structural system for tall buildings is not an easy task. Where, as building height increases the importance of lateral loads action rises in an accelerating rate. There are two types of lateral loads, wind and seismic loads. Wind load presents the most critical lateral loading for modern tall buildings, which have lightweight skeletons that cause uncomfortable horizontal movements for occupants. Also, wind is not constant either with height or with time and is not uniform over the sides of a building. So, windy weather creates a variety of problems in tall buildings, causing concern for buildings owner and engineers alike. Where,

    excessive vibration due to this load is a major obstacle in design and construction of a modern tall building. It should be limited to prevent both structural and nonstructural damage.

    The five major structural systems used for the Tall Buildings are:

    1. Rigid frame system

    2. Rigid frame with shear wall

    3. Shear wall with opening

    4. Outrigger system

    Rigid frame system

    Consist of column and girders joined by moment resistant connections. The lateral stiffness of a rigid-frame bent depends on the bending stiffness of the columns, girders and connections in the plane of the bent

    Shear Wall Structure

    It is a vertical continuous stiffening element, that deform in bending mode.It is Used in reinforced concrete buildings and suited to residential buildings and hotels.

    Wall-Frame Structures

    1. When shear walls are combined with rigid frame the walls, which tend to deflect in a flexural configuration, and the frames, which tend to deflect in shear mode are constrained to adopt a common deflected shape by the horizontal rigidity of the girders and slabs.

    2. Consequences, the walls and frames interact horizontally, especially at the top to produce a stiffer and stronger structure.

    3. The interacting wall-frame combination is appropriate for building in the 40 to 60 stories range, well beyond that of rigid frames or shear walls alone.

    Outrigger-Braced Structures

    Outriggers are connected directly to the core and to exterior columns. Used in reinforced concrete and steel buildings. Outriggers restrain the rotation of the core and convert part of the moment in the core into a vertical couple at the columns (columns restrained outriggers).

  2. MAIN OBJECTIVES

    1. Recommending a structural system for a certain building height, with the intention of limiting the wind drift to acceptable limits without paying a high premium in the quantity of structural material.

    2. Presenting a comparative analysis between the most common structural systems of tall buildings built around the world within the past decades according to structural period and base shear values, drift and displacements.

    3. Conceiving and applying the structural systems to extremely tall buildings is a practical demonstration of the engineer's confidence in the predictive ability of the analysis by commercial software.

  3. METHODOLOGY

    The methodology of this study is on comparison of behavior of structural systems on tall building is having various types of structural systems for various building heights, storey and load intensities. Shear walls and outriggers are also considered in this project and outriggers optimum location such that maximum utilization of this can be achieved is also given due importance.

    This study is intended to be helpful to clear the ambiguity in choosing the required type of system for a building as per the requirements of our building height, its location and its loading intensities.

    1. Model Data

      Structure OMRF

      No of stories G+15, G+30, G+45, G+60

      Story height 3.5 m

      Grade of concrete M50

      Grade of steel Fe415

      Thickness of slab 0.125m

      Beam size 0.45×0.6m Column size (1.8×1.8,1.4×1.4,1.0x1.0,0.8×0.8)

      Seismic zone III

      Soil type II

      Importance factor 1

      Response reduction factor 3

      LL 4 kN/m2

      SDL 2 kN/m2

      TRL 1.5 kN/m2

    2. The model is a regular-shaped symmetrical plan with dimensions 49x49m. In all structural modeling, slab spans are assumed to be 7m, arranged in five bays in each direction, as shown in Fig. 1. The plan has a 7×7 m central core opening. The storey height is assumed to be 3.5 m. The analysis used is a three-dimensional analysis of detailed finite element models. The columns and beams were represented by frame- type element, while shear walls and core components were represented by shell-type element.

    Fig.1 General Layout for all structural model plans

    Method of Analysis Equivalent Static Force Method

    In the present study, the analysis of the structure is made for seismic loads using Equivalent Static Force Method because of symmetry of the structure, both in geometry and in mass.

    Analysis of Structural Systems

    ETABS software is used for the analysis of all structural systems by Equivalent Static Lateral Force Method for Zone

    III. Based on the method of analysis considered, lateral load calculations are made by the software itself and then applied to the structure to analyze. Hence the results are tabulated for the study of behavior of structural systems

    Load Calculations

    All the structural systems are subjected to three types of primry load cases as per the provisions of IS Code of Practice for Structural Safety of Buildings Loading Standard IS 875-1987 (Part I).

    They are:

    1. Dead Load (From IS: 875-1987(Part I))

    2. Live Load (From IS: 875-1987(Part II))

    3. Seismic Load (From IS: 1893-2002(Part I)

    Type of Structure

    Type of structure considered for the analysis is a ORDINARY reinforced concrete moment resisting frame. Hence response reduction factor, R=3.0 from Table 7 of IS 1893(Part I) 2002

    Importance of Structure

    As this structure can be used as general building, its importance of structure is represented by the

    Importance factor, I=1.0 from Table 6 of IS 1893(Part I) 2002.

    Soil Type

    The average response acceleration coefficient (Sa/g) depends on the type of soil where the structure is located and the fundamental natural time period (Ta) of buildings. Hence knowing the soil type becomes important for the calculation of lateral load

    Seismic Zones

    In the present study, the behavior of all the structural systems is studied for all the seismic zones of India as per IS 1893(Part I) 2002. The Zone Factors and Seismic Intensities are as mentioned below as per Table 2 of IS 1893(Part I) 2002

    Method of Analysis

    In the present study, the analysis of the structure is made for lateral loads using Equivalent Static Force Method because of symmetry of the structure, both in geometry and in mass.

    Assumptions

    1. Material: Concrete is assumed to behave linearly elastic. The modulus of elasticity Ec will be taken as 4700'c. Where, the specified compressive strength of concrete 'c is assumed equal to 40 Mpa, as used in practical applications of tall buildings.

    2. Participating components: Only the primary structural components are assumed to participate in the overall behavior. The effects of secondary structural components and nonstructural components are assumed to be negligible; these include staircases, partitions, cladding, and openings.

    3. Floor slabs: are assumed to be rigid in plane, with thickness equal to 30 cm in all models. This assumption causes the vertical elements at any floor level undergo the same components of translational displacement and rotation in the horizontal plane.

    4. Cracking: The effect of cracking in reinforced concrete members due to flexural tensile stresses is represented by reducing moment of inertia,

    5. Constraints: Supporting bases of all structural models are fixed supports.

    6. Loading:

      1. Gravity Loads: Dead load is taken as 2kN/m², the building weight and its content is considered in the dead load and calculated based on material densities by the program. While, live load is taken as 4kN/m² .

      2. Wind loads: will be developed according to Indian standard.

    7. Wind loading: Vb=50

    Terrain category =3 Structure class=B

    Risk co-efficient k1=1 Topography k3=1 Sample Calculations

    Natural Time Period for Rigid System: For 15 storey building

    Ta=0.075 = 0.075(51)0.75= 1.43s

    For 30 storey building Ta= 2.43s For 45 storey building Ta= 3.31s For 60 storey building Ta= 4.11s

    Natural Time Period for Rigid Frame With Shear Wall, Shear Wall With Opening And Outrigger System

    For 15 storey building

    Ta=0.09×51 = 0.075(51)/491/2= 0.65s

    For 30 storey building Ta= 1.333s For 45 storey building Ta= 2.00s For 60 storey building Ta=2.68s

    Storey V/S Drift

    According to Clause 7.11.1 of IS 1893-Part I: 2002 and Clause IS 456:2000, the maximum allowable drift is 0.04h and allowable displacement is 0.04H (H/250) where h is the storey height and H is the total height of the building, for a partial safety factor of 1.0.

    Hence, the allowable displacements of a particular height of the building and maximum allowable storey drifts are given in

    No. OF

    STORIES

    RF

    RF WITH

    SW

    SW

    OUTRIGGER

    15

    0.000966

    0.000174

    0.000192

    30

    0.00199

    0.000598

    0.000796

    0.000498

    45

    0.002436

    0.000853

    0.001285

    0.00069

    60

    0.002709

    0.001229

    0.001994

    0.001007

    Table 1 for a storey height of 30m

    Fig.3 Story V/S Drift for G+15

    Fig.4 Story V/S Drift for G+30

    Fig.5Story V/S Drift for G+45

    Fig.6 Story V/S Drift for G+60

    The above investigation comes to the conclusion that rigidity/stiffness of composite high-rise building is inversely proportional to its height i.e. the lateral stiffness decreases with increase in height of structure. Story drift value for all structural systems are within the limits specified in IS 1893 2002, But my comparative study it can be observed that, story drift is maximum in the case of Rigid frame, and minimum in case of outrigger system, and story drift in case of shear wall systems where there are no beams, drift is more that rigid frames with shear wall system.

    TOP MOMENTS

    Stories

    RF With SW

    Outrigger

    15th

    146986.9

    30th

    496955.8

    438561.1

    45th

    469433

    398915.8

    60th

    549684.2

    464363.9

    Table 2 Top Core Moments for rigid Frame with Shear Wall and Outrigger System

    Fig 7 Top Core Moments for Rigid Frame with Shear Wall and Outrigger System

    BOTTOM

    MOMENTS

    Stories

    RF With SW

    Outrigger

    15th

    154190.1

    30th

    511205.9

    452783

    45th

    475548.4

    405016.9

    60th

    556031.6

    470692.3

    Table 3 Core Moments at Base Level for rigid Frame with Shear Wall and Outrigger System

    Fig 8 Core Moments at Base level For Rigid

    Frame With Shear Wall And Outrigger Systems

    From above graphs we can conclude there is substantial reduction in bending moment in core, when outrigger system is added to the structure. There is substantial reduction in forces in core bending moment in particular when outrigger system is added to the structure

  4. CONCLUSION AND FURTHER SCOPE OF PROJECT

Based On The Limited Study Carried Out, The Following Conclusions Are Made:

  1. Under the effect of wind loads, as the height of the structure increases, the lateral deflection and the overturning moment at the base increase. Tall buildings almost always require additional structural material, in order to limit the lateral deflection and resist the overturning moment, over and above that required for gravity loads only.

  2. The key idea in limiting the wind drift in a tall building is by changing the structural form of the building into something more rigid and stable to confine the deformation and increase stability

  3. The stiffness (rigidity) and stability requirements become more important as the height of the structure increases, and they are often the dominant factors in the design

  4. As the building height increases time period has increased i.e., 45% to 50% increase can be observed from the graphs for every addition of 15 stories.

  5. Maximum base shear at the base of the building increase with the increase i number of stories. Hence it can be conclude that base shear depends mainly on seismic weight of the building.

  6. The reduction in the displacement of rigid frame with shear wall framed structure is 50 % with respect to R.C.C. frame

    Structure, 25% in case of shear walls and 60 % when outrigger is used.5.2 Structural systems conclusions.

    The main conclusions of this comparative study, concerning the efficiency of the presented five structural systems and the ability of each system in limiting the wind drift for a certain building height, can be summarized in the following:

    Rigid frame system

    The relatively high lateral flexibility calls for uneconomically large members.

    It is not possible to accommodate the required depth of beams within the normal ceiling space in tall rigid frame.

    Not stiff as other three systems and considered more ductile and more susceptible to wind failures.

    Rigid frame with shear wall

    The benefits of this system depend on the horizontal interaction, which is governed by the relative stiffness of walls and frames and the height of the structure.

    As the structure height and the stiffness of the frames increase, the interaction between walls and frames increases. The major factor in determining the influence of the frames on the lateral stiffness of this system is the height.

    As the structure height increases, the sharing of walls from the base shear decreases with respect to frames and more interaction induced between both of them.

    Shear wall/central core system

    • More economic than rigid frame.

    • A great increase in flexural stiffness with respect to rigid frame and Outrigger system

    • The most economic system.

    • Creates a wider effective system for reducing the overturning moment in the core structures.

The outrigger structural systems not only proficient in controlling the top displacements but also play substantial role in reducing the inter storey drifts

The beneficial action is a function of two factors:

  1. The stiffness of the outrigger (Varies inversely with the outrigger distance from the base)

  2. Its location in the building.

An effective system in case of finding out at what level the outriggers should be placed in order to have a maximum impact on the wind drift.

Very effective in increasing the structure's flexural stiffness, but it does not increase its resistance to shear, which has to be carried mainly by the core

Suggested Systems for Different Heights

Table 3 demonstrates the recommended structural systems for different heights. This table is organized according to the structural efficiency in limiting the wind drift as well as the cost and stiffness of the structure. These suggestions provide a direction to structural engineers for optimum system selection.

Height

Suggested System

10 stories (35 m)

Rigid Frame , Shear Wall

20 stories (70 m)

Shear Wall, Outrigger

30stories (105 m)

Rigid Frame with Shear Wall,

Outrigger

40stories (140 m)

Rigid Frame with Shear Wall,

Outrigger

50stories (175 m)

Outrigger

60stories (210 m)

Outrigger

Table 3 structural systems for different heights

REFERENCES

  1. Taranath Steel, Concrete, & Composite Design of Tall Buildings. New York: McGraw-Hill.

  2. S. Fawzia and T. Fatima, Deflection Control in composite building by using Belt truss and Outrigger System. Proceedings of the 2010 World Academy of Science, Engineering and Technology conference, pp. 25- 27 August 2010, Singapore

  3. Stafford Smith B, Salim I. (1981). Parameter study of outrigger- braced tall building structures. Journal of the Structural Division.

  4. J. Zils and J. Viis, An Introduction To High Rise building Structure Magazine Nov 2003

  5. Bush T. D., Jones Behavior of RC frame strengthened using structural systems, Journal of Structural Engineering, Vol. 117, No.4, April, 1991

  6. M.D. Kevadkar, P.B. Kodag, Lateral Load Analysis of R.C.C. Building, International Journal of Modern Engineering Research (IJMER) Vol.3, Issue.3, May-June. 2013 pp-1428-1434 ISSN: 2249- 6645.

  7. Alfa Rasikan, M G Rajendran (1992) Introduction to high rise building using shear wall systems, Journal of Structural Engineering, Vol. 117, No.4, April, 1991

  8. P. S. Kumbhare and A. C. Saoji Wind drift design of steel- framed buildings: state of the art."

  9. Abdur Rahman, Saiada Fuadi Fancy and Shamim Ara Bobby Minimum Design Loads for Buildings and Other Structures

  10. Smith, B.S. and Coull, A. (1991) Tall Building Structures: Analysis and Design. John Wiley and Sons, Inc., New York.

  11. Abalos, I., & Herreros, J. (2003) Tower and Office: From Modernist Theory to Contemporary Practice. Cambridge, MA: MIT Press.

  12. Muto, K. et al. (1973), Earthquake Design of a 20 Story Reinforced Concrete Building, Proceedings of 5thWCEE, June, Vol.2, pp.1960-1969.

  13. Niwa, N. et al. (1995), Passive Seismic Response Controlled High-rise Building with High Damping Device, Earthquake Engineering and Structural Dynamics, Vol.24, pp.655-671.

  14. Ali, M.M., & Armstrong, P.J. (Eds). (1995). Architecture of Tall Buildings. Council on Tall Buildings and Urban Habitat Monograph. New York: McGraw-Hill.

  15. Fazlur Khan . (1969). Recent structural systems in steel for high- rise buildings. In Proceedings of the British Constructional Steelwork Association Conference on Steel in Architecture. London: British Constructional Steelwork Association