- Open Access
- Total Downloads : 454
- Authors : G. Praveen Kumar, S. Palanivelraja
- Paper ID : IJERTV3IS061738
- Volume & Issue : Volume 03, Issue 06 (June 2014)
- Published (First Online): 01-07-2014
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Spatial Pollution Rose Dispersion Pattern ( SPR ) of SO2 in the Vicinity of Thermal Power Station At Ennore – Manali Area
1G. Praveen Kumar 2 Dr. S. Palanivelraja
1Research scholar, 2Professor
Department of Civil Engineering, Department of Civil Engineering Annamalai University Chidambaram Annamalai University Chidambaram TamilNadu,India. TamilNadu,India.
Abstract-The purpose of the present study was to describe the pattern of Spatial Pollution dispersion pattern in the neighbourhood of Thermal Power Stations at Ennore Manali area, near North of Chennai. Ennore-Manali area houses two Thermal Power Stations namely Ennore Thermal Power stations and North Chennai Thermal Power stations. Ennore Thermal power stations is designed to produce electricity at 450 MW capacity ( 2 x 60 MW ; 3 X 110 MW ) using coal as the fuel. North Chennai Thermal power stations is designed to produce electricity at 630 MW capacity ( 3 x 210 MW ) using coal as the fuel. The emission from all the stacks is considered in the Gaussian diffusion equation, for predicting ground level downwind concentrations. The meteorological data gathered for a period of one month is chosen for predictions. This work involves computations and draw the spatial pollution rose pattern of short-term averages of SO2 Concentrations in the neighbourhood of Ennore Manali area. The SO2 isopleths indicated for assessing the most adverse meteorological situations would throw further light on future expansion prospects of Industrial projects at Ennore- Manali area.
Keywords: Sulphur Dioxide, Spatial Pollution Rose dispersion pattern
-
INTRODUCTION
Industrial air basin, in the contemporary India, experiences a profound change in the nature and extent of air pollution. Factors such as industrial expansion, accelerated consumption of products, fuels and energy, the introduction of new chemical and petrochemical processing industries, the vastly increased use of automobiles and the growth of urbanization, have all greatly increased the varieties and volumes of pollutants thereby presenting new threats to human health, animal health, plant life, property value and the Environment. This is the very reason why this study has been chosen to protect the health and welfare of the public, from the harmful effects of air pollutants.
North Chennai industrial area, has registered a successful and planned expansion of industries during the past five decades. However, a sporadic development of residential colonies has also sprung up in the area. As a result, the magnitude and severity of air pollution problems have attracted the attention of the public. There is a necessity, therefore, to adopt a systematic procedure for controlling quantum of pollutants emitted from each industry located in the area, in order to maintain the ambient air quality in North Chennai area, and in the neighborhoods of the industries at North Chennai area within safe limits. The first step to be initiated, in this relevance, is to conduct another Ambient Air Quality Data in the North Chennai area with the purpose of assessing the presently prevailing air quality. Such an attempt would be helpful to gather data on aspects such as (i) the various industrial sources which emit air pollutants into the atmosphere, (ii) the quantity and nature of emissions discharged by each industry, (iii) the wind turbulence condition that prevails in the area, and (iv) the ambient air concentrations of various pollutants occurring at breathing level in the area.
-
MODELLING OF AIR POLLUTANT
DISPERSION
The Atmospheric dispersion models are simulated mathematically. The physical mechanism and chemistry that are governing the transport, dispersion and transformation of pollutants in the atmosphere are taken into account in the simulation. They are the indispensable tools for prediction of air quality in the ever expanding industrial environments. Several models are available for predicting air quality due to emissions from multiple point sources. When applied for a specific industrial situation and prevailing ambient environmental conditions, performance evaluation of these models is much essential to assess their compatibility and accuracy. The reliability of the model also must be assessed by applying historical meteorology, varying quantities of emissions and measured air quality of the specific industrial
environment, with respect to the prevailing wind turbulence and stability conditions of the atmosphere.
In so far as a particular pollutant is concerned, the relationship between the rate of emission of the pollutant discharged through the exit-point of the chimney (stack) and the resulting concentration of the pollutant in atmospheric air at breathing level is to be evolved. Any Air Quality Survey would offer the necessary data for evolving the relationship between the emission rate and the resulting ambient air concentration of a specific pollutant at any receptor point. This relationship would necessarily take into account the following factors, namely, (i) wind speed and wind direction prevailing in the area, and other meteorological parameters which are relevant to the measurement of the atmospheric turbulence and the atmospheric mixing conditions that are prevailing (ii) the height of the exit-point through which an industrial chimney discharges its emissions, and (iii) the velocity with which the emissions are discharged into the atmosphere through the chimney. (iv) the temperature differential between the hot gases at the time of mixing with the ambient air etc. This attempt, to correlate the pertinent parameters in a cause effect relationship, for describing the physical mechanism of dilution of pollutants in atmospheric air, is often referred to as Modeling of Air Pollutant Dispersion.
Air pollution control field-operations, as practiced in advanced and industrialized countries, would consist of two steps, namely, Surveillance and Enforcement. The mission of Air Quality Management as a whole is to implement plans that have been adopted to achieve accepted levels of air quality, through the essential steps of Surveillance and Enforcement.
-
NEED FOR THE STUDY
The performance evaluation of USEPA ISCST3 model is found satisfactory as reported by Ganapathy Subramanian. L.R.,( 2006) at Manali region in Chennai. However, this study has considered the emission only from one power plant at Manali – Ennore area. Therefore, detailed study is needed for assessing the comprehensive status of the prevailing air pollution scenario in the entire North Chennai Air Basin, so that the comparatively larger emissions of North Chennai Thermal Power Stations could be included in the assessment.
-
OBJECTIVES OF THE STUDY
The objective of the study is to draw Spatial Pollution Rose dispersion pattern of SO2 in the neighbourhood of Thermal Power Plants at Ennore and North Chennai, to describe the air quality in North Chennai Air Basin.
-
MATERIALS AND METHOD
The ISC Short-Term Model Algorithms
The ISCST3 model is a steady-state Gaussian plume model, which can be used to assess pollutant concentrations from a wide variety of sources associated with an industrial source complex. The following options have been selected for regulatory applications: set the regulatory default option; i.e., use the keyword DFAULT, which automatically selects stack tip downwash, final plume rise, buoyancy induced dispersion (BID), the vertical potential temperature gradient, a treatment for the calms, the appropriate wind profile exponents, the appropriate value fo pollutant half-life, and a revised building wake effects algorithm; set the rural option (use the keyword RURAL) or urban option (use the keyword URBAN); and set the concentration option.ISCST3 uses Briggs (1969, 1971, 1975) plume rise equations for final rise. The Rural dispersion coefficients from Turner (1970) are used, with no adjustments for surface roughness or averaging time. The Buoyancy induced dispersion (Pasquill, 1976) is included. There are six stability classes used. The Mixing height is accounted for multiple reflections until the vertical plume standard deviation equals
1.6 times the mixing height and the uniform vertical mixing is assumed beyond that point. The Perfect reflection is assumed at the ground.
The Gaussian Equation
The ISC short-term model for stacks uses the steady- state Gaussian plume equation for a continuous elevated source. For each source and each hour, the origin of the source's coordinate system is placed at the ground surface at the base of the stack. The x-axis is positive in the downwind direction, the y-axis is crosswind (normal) to the x-axis and the z-axis extends vertically. The fixed receptor locations are converted to each source's coordinate system for each hourly calculation of concentrations. The hourly concentrations calculated for each source at each receptor are summed up to obtain the total concentrations produced at each receptor point by the combined source emissions. For a steady-state Gaussian plume, the hourly concentration at downwind distance x (meters) and crosswind distance y (meters) is given below.
Where
Q = pollutant emission rate (mass per unit time),
K = a scaling coefficient to convert calculated concentrations to desired units (default value of 1 x 106 for Q in g/s and concentration in µg/m3),
V = vertical term,
D = decay term, y, z = standard deviation of lateral and vertical concentration distribution (m), Us
= mean wind speed (m/s) at release height
Equation (1) includes a Vertical Term (V), a Decay Term (D), and dispersion parameters (y and z).
-
DESCRIPTION OF STUDY AREA
The study region, North Chennai air basin is an industrial belt covering an area of about 10 x10 km2 with a flat terrain located close to Chennai metropolis, India. It houses a major refinery, petrochemical, fertilizer and chemical industries apart from Ennore Thermal Power Station (ETPS) and North Chennai Thermal Power Station (NCTPS) whose stack emissions contribute significantly to air pollution of SO2.
Figure-1: Description of Study Area.
-
APPLICATION OF ISCST3 MODEL AT NORTH
CHENNAI AIR BASIN
The data requirements for evaluation analysis consist of three important parts: the emission inventory, the meteorological data and the air quality monitoring data.
Emission Inventory
The emission source information that needs to be the input to the model is restricted to the physical stack dimensions (height, location, internal diameter), as well as the velocity and temperature of the released gas, and the hourly SO2 emission rates. NCTPS and ETPS that are responsible for SO2 generation in the area are considered. Table 1 show the stack co-ordinates, stack height, stack diameter at exit point, emission rate of SO2, exit stack gas velocity and exit gas temperature. A typical SO2 emission file for NCTPS stacks has been developed for a period of 28 days.
Table-1. Emission Inventory
Stack Name
Stack Coordinates
Stack Heigt (m)
Stack Inner Dia
meter (m)
Emission rate of SO2 g/sec
Lat
Long
NCTPS
13°1
80°19
Unit 1
5.03
.727
275
4.35
9.126
(boiler)
6N
E
Unit 2 (boiler
13°1
5.07
7N
80°19
.714 E
275
4.35
5.211
Unit 3 (boiler)
13°1
5.13
1N
80°19
.737 E
275
4.35
6.966
ETPS
Stack 1
13°1
2.08
2N
80°18
.708 E
80
4.61
21.924
ETPS
Stack 2
13°1
2.10
2N
80°18
.661 E
80
4.61
10.746
ETPS
Stack 3
13°1
2.10
4N
80°18
.641 E
80
4.61
21.78
Meteorological Data
The model requires the site specific meteorological information as input data .It is restricted to the Julian day of the year, the average wind flow vector, wind speed, height of the mixing layer, ambient air temperature, and the Pasquill stability category. The meteorological file for ISCST3 Model has been prepared for 28-days from the meteorological monitoring conducted during a period of 28 days in the North Chennai Air Basin from 1/2/2011 to 28/2/2011. The meteorological monitoring consists of hourly wind speed, wind directions, dry and wet bulb temperatures and cloud cover. The most predominant wind direction during the period was the wind blowing from North. Therefore, this study has chosen the sampling stations, which are all located on the downwind directions. The typical meteorological file developed for the 28 days is considered in this study.
Table – 2: A typical met file format is shown below
Y M D H
WD
UBAR
AMT EM
S T B
MIX( R)
11020101
295.72
2.3000
306.1
1
0.0
11020102
275.89
2.2800
305.8
1
0.0
11020103
282.57
2.3600
305.1
1
0.0
11020104
280.92
2.3300
304.7
1
0.0
11020105
286.56
2.3500
304.4
1
0.0
11020106
290.14
2.3800
304.3
1
0.0
11020107
281.19
2.3800
304.2
1
0.0
11020108
288.59
2.4300
304.5
1
0.0
11020109
275.81
2.6200
306.4
2
400.0
11020070
240.57
2.7500
308.7
2
500.0
11020071
166.92
2.9100
310.1
2
600.0
11020072
152.59
2.9100
310.9
2
700.0
11020073
164.09
2.9100
307.2
2
900.0
11020074
147.06
2.8900
307.3 2
1200.0
11020075
146.00
2.9600
307.3
2
1500.0
11020076
147.44
2.8700
307.1
2
2000.0
11020077
128.56
2.8000
310.7
1
1800.0
11020078
075.78
2.7200
309.9
1
1600.0
11020079
107.16
2.6600
308.7
1
0700.0
11020120
106.66
2.6600
308.4
1
900.0
11020121
073.41
2.6100
308.2
1
600.0
11020122
071.07
2.5900
308.1
1
1400.0
11020123
130.16
2.5900
308.1
1
0.0
11020124
261.43
2.3700
307.4
1
0.0
11020201
281.79
2.2800
306.3
1
0.0
11020202
275.50
2.2700
305.9
1
0.0
11020203
278.83
2.2700
305.7
1
0.0
11020204
283.23
2.3000
305.0
1
0.0
11020205
281.16
2.2900
304.6
1
400.0
11020206
278.16
2.2800
304.4
1
500.0
11020207
286.13
2.3300
304.3
1
600.0
11020208
281.35
2.3400
304.5
1
700.0
11020209
284.23
2.4500
306.0
2
900.0
Air Quality Data
The ISCST3 also requires input information on measured SO2 air quality data measured at North Chennai Air Basin during the same period. Such information is needed to test the performance of the ISCST3 model. This study has chosen the Ambient Air Quality data from the short-term air quality survey conducted at seven AAQ monitoring stations such as Kattupalli, Athipattu, Minjur, Perungavoor, Manali, Ennore and Kathivakkam in North Chennai Air Basin. An average time of 24-Hours was employed for the measurement of SO2. All the stacks and air quality stations coordinates (X,
Y) were determined by assuming that the X axis is positive to
the east of the user-specified origin and the Y axis is positive to the north.
-
RESULTS AND DISCUSSION Meteorologicalformonitoring has been conducted
during a period of 28 days from 1/2/2011 to 28/2/2011.The
wind rose diagrams have been prepared. SO2 emission rate has also been worked out and typical values are used in the ISCST3 model. The ground level concentrations (GLC) at the receptor points has been obtained by running the ISCST-3 model, Isopleth plot has been marked on a 25km x 25km grid.
In this study, the computed results have been compared with the observed 24-hour averages. During the period of study, the most predominant wind direction has been from North ( N ). Hence, this study has chosen seven air quality-monitoring stations such as Kattupalli, Athipattu, Minjur, Perungavoor, Manali, Ennore and Kathivakkam. The ISCST3 model has been used for predicting the concentration of the pollutant SO2 at the seven sampling stations. These simulations are carried out for 1 set of 24- hourly meteorological data, which include various combinations of stability and wind speed, which may be possible during the whole day.In this Study, the model performance was evaluated by comparing the monthly predicted concentrations of SO2 obtainedin the model with the measured- concentrations, in the cases of the 3- Continuous Ambient Air Quality Monitoring Stations.
Linear (Series
)
10
15
Series
20
S
O
2
30
25
O
B S E R V E
D
y = 0.811x
R² = 0.865
35
Figure-2 shows scatterplots for the measured SO2 concentrations and the predicted SO2 concentrations in the downwind receptor locations in the ISCST3
0
0
50
PREDICTED SO2
5
model, applicable to North Chennai Air Basin.
Figure-2. Correlation between predicted and measured concentration of SO2
The results of the statistical analysis of this Study reveals that the value of coefficient of correlation r2 =0.865 and index agreement d=0.77, which implies that the model performed well.
Figure 3:3D Surface View of Spatial Pollution Rose Pattern of SO2 for the month of February 2011
Figure 4:3D Wire Frame View of Spatial Pollution Rose Pattern of SO2 for the month of February 2011
Figure 5:2D View of Spatial Pollution Rose (SPR) Pattern of SO2 for the Month of February
CONCLUSIONS
In order to study the prevailing metereological potential at Ennore-Manali, a short-term micro meterological monitoring was gathered from 01-02-2011 to 28-02-2011. The concentrations of pollutant namely SO2, for the months of February, 2011 were plotted using ISCST3 model. From the model prediction it was found that the concentrations of criteria pollutants were below the permissible limits prescribed by Central Pollution Control Board (CPCB). The results were shown that the 8 hour SO concentration well below the Ambient Air Quality Standards. ISCST3 Modeling has been used to simulate the spatial Pollution Rose pattern of SO2 in North Chennai Air Basin Considering the emissions from North Chennai Thermal Power station (NCTPS) and Ennore Thermal Power Station (ETPS).
REFERENCE
-
Aggarwal A.L, Sivacoumar R., Goyal SK 1997 : Air Quality Prediction : influence of model parameters and sensitivity analysis, India Journal of Environmental Protection, 17(9), 650-655.
-
Al.Sudairawi.M., Mackay.K.P1986 : Evaluating the performance of ISC-ST model, Environmental Software 3(4), 180-185.
-
Bowers, J.F, et al 1981, An evaluation study for the ISC dispersion model / EPA – 450 / 4-81-002, RTP, NC.
-
Briggs, G.A (1973), Diffusion estimation for small emissions, ATDL contribution 79, Air Resources, Atmospheric Turbulent and Diffusion Laboratory, Oak Ridge, TN, United States.
-
Briggs, G.A., 1971: Some recent analyses of plume rise observations. pp 1029-1032 in Proceedings of the Second International Clean Air Congress. , Academic Press, New York.
-
Carpenter, S.B. et. al., (1971), Principal Plume Dispersion Model for TVA Power Plants, J. Air Polln. Control Assn., 21, pp. 491- 495.
-
Chockalingam, M.P., (1988): Environmental Impact Assessment in respect to air quality in the neighborhood of second Thermal Power Station at Neyveli, a Technical report furnished to the Neyveli Lignite Corporation, Neyevli
-
Chockalingam, M.P., A Report on the Ambient Air Quality Prevailing in the Neighbouhhod of the Tuticorin Power Station. Also Air Quality Study for a 630 MW Coal-fired Thermal Power Plant in North Madras (1986) : Technical Reports submitted to the Department of Environment and Forests, Government of India, New Delhi, for obtaining Environmental Clearance for the proposal of the TamilNadu (State) Electricity Board, Madras (TamilNadu, India).
-
GanapathySubramanian,L.R., et.al. (2006): Modeling of SO2 emission from point sources in Manali region of Madras, India, International Journal of Applied Sciences, ANSINET publishing, Vol. 6 (15), pp 3035-3043.
-
Goyal P, Sidhartha et al 2002, Effects of winds on SO and SPM concentrations in Delhi, Atmospheric Env., 36(17), 2925-2930.
-
Hanna, S.R. et. al (1982), Handbook on Atmospheric Diffusion, Published by Technical Information Centre, U.S. Department of Energy.
-
Indian Standards Institution, (1978), Guidelines for Micrometeorological Techniques in Air Pollution Studies (IS : 8829 1978).
-
Padmanabhamurty, B (1988), Manual for Environmental Impact Assessment Due to Thermal Power Plants on Ambient Air Quality, under a Project funded by the Department of Environment, Forests and Wild Life, Government of India, New Delhi.
-
Palanivelraja. S., et al, 2001 : Computer aided assessment of worst meteorological situation, Proc. of National Seminar on Environmental Management and Pollution abatement, Annamalai Nagar, T.N. India.
-
Palanivelraja. S. et al (2009), Spatial Pollution Rose (SPR) pattern of SO2 in the vicinity of Thermal Power Station at Neyveli, Journal of IPHE, India, vol. 2009-10, No.3.
-
Pasquill, F., 1976: Atmospheric Dispersion Parameters in Gaussian Plume Modeling, Part II, Possible Requirements for change in the Turner Workbook values, EPA-600/4-76-030b, US Environmental Protection Agency,Research Triangle Park, NC.
-
Schulman, L.L., et al., 1985: Evaluation of the proposed down wash modifications to the Industrial source complex model, Environmental Research and Technology, Inc., P-B 810-012, Boston, MA.
-
Subbiah.V. et al (2010), Modeling of Air Pollution Impact in the neighbourhood of a Combined Cycle Gas Turbine (CCGT) Thermal Power Plant, Hindustan Journal, vol.3, February 2010 PP 87-94.