Studies on Waste Water Characteristics of Dairy Effluent and Evaluation of Kinetic Parameters
S. Sharada 1, M. Kalyan Kumar 2
1, 2. Assistant Professor, Department of Chemical Engineering,
JNTUACE, Anantapur ( A.P)
Abstract: – Dairy effluent is easily amenable to biodegradation. However if the dairy effluents are discharged without treatment, the foul smell will be generated and spoils environment. So it is very much essential to properly treat the dairy effluent. The solid wastes from the effluent coming out from the dairy plant can be used as fertilizer and treated liquid water.i,e. clear water is used for irrigation purpose. The kinetic coefficient for the activated sludge process for dairy effluents has been calculated. These kinetic parameters are very essential for the design of effluent treatment plant. We have to reduce capacities of the existing plants and encourage small scale units in the rural areas for uniform development in the small scale industries will meet total requirements which shall go as long way resolving solution problems of developing countries including India in a big way. In the present study the effluent characteristics have been studied for a period of two months. The inlet BOD varied from 520 to 580 mg/l. the inlet pH varied from 4.9 to 5.3. The inlet TSS varied from 750 to 930 mg/l. the kinetic parameters like Y, Kd have been evaluated. The hydraulic retention time from the design calculations is 15hours. Whereas the actual HRT is 16hrs.The effluent treatment has a very good potential for biogas generation.
Keywords: Activated Sludge Process, Biodegradation, BOD, Hydraulic retention time.
-
INTRODUCTION:
Milk is one of the most important stuffs and is must in quality as it reaches consumer. Primary milk was stored in dehydrated state by drying. But the study of causes for deterioration was paved way method, called pasteurization. The study revealed that chemical internally by enzymes and externally due to micro-organisms are responsible for milk spoilage and deterioration [1]
It is common practice to collect milk of several milking in a bulk tank before transportation of the milk to the dairy.. To prevent microbial growth in the farm bulk tank, milk has to be cooled during storage. Hygienic milk production can be done by healthy animals, good feed and asceptic operations which were explained in Milk processing and quality management edited by A.Y.Tamime., 2009 Blackwell publishing Ltd, ISBN: 978- 1- 405- 14530-5 [2].
To know the quality of milk, different brands of milk was taken and analyzed. Their physical, chemical and microbial quality was analysed by M.Asaduzzaman.,et al [3].
Foster et al reported that the principal involved in
increases in milk by which there is a raise in osmotic pressure and binding water [4]. Radeva et al reported that the rancidness in the condensed milk was caused by lipase when the viscosity of the milk is low [5].
-
ANALYTICAL PROCEDURE:
The samples had collected were analyzed for conductivity, color, BOD, turbidity, COD and TDS present in the permeate sample at the analytical division. The conductivity of permeate and concentrate samples are analyzed by using digital conductivity meter, pH of the feed sample was analyzed by pH meter. Buffer tablets with pH 4.0, 7.0 & 9.2 were taken as reagents.
First rinse the electrode with distilled water and dry them using a soft tissue paper. Standardize using buffer solution. Remove the buffer, rinse and blot dry. The difference should be within 0.1 units. Check the pH of the effluent.
-
Oxygen demand analysis:
-
Biological oxygen demand analysis
-
Chemical oxygen demand analysis
Chemical oxygen demand (COD): the organic matter gets oxidized completely by K2Cr2O7, in the presence of H2SO4 to produce CO2 and H2O. The excess K2Cr2O7, remaining after the reaction is titrated with the Fe ( NH4) 2 ( SO4)2.
The dichromate consumed gives the O2 required for the oxidation of the organic matter.10 ml glass vials with lids ensuring no leakage and Electric sand bath
-
-
Experimental Procedure
The glass vials are thoroughly cleaned using distilled water. A pinch of mercuric sulphate is taken into the glass vial.3ml of potassium dicloromate is accurately measured and added into the vial.2ml of a mixture of sulfuric acid and silver sulphate is added very slowly into the vial after which the sample is added into the vial. if it is permeate then 1ml of the sample is taken and incase of concentrated samples, 0.5ml of the sample with 0.5ml of distilled water is taken. The lid is tightly closed and shaken vigorously. Mix well if the colour turns green, either take fresh sample or add more dichloromate and acid. The vial is now placed on the sand bath and heated. The temperature of the sand bath is adjusted to around 105oC. After two hours the vial is collected. it is diluted to about three times and titrated
against an excess of K Cr O with 0.1N Fe( NH ) (SO )
preservation of milk product depends on the concentration
2 2 7
4 2 4 2
using ferrous ion indicator. A sharp color change from blue green to wine red indicates the end or completion of titration. The same procedure is repeated for the blank using distilled water. The COD is calculated from the following equation.
COD(mg/l) = ( a-b)N * 8000/ Vol.Sample (ml) Where a= Vol.(ml) of Fe( NH4)2 ( SO4)2 for blank
b = Vol.(ml) of Fe( NH4)2 ( SO4)2
N = the normality of Fe( NH4)2 ( SO4)2
The test is mainly bioassay procedure involving measurement of O2 consumed by bacteria while stabilizing organic matter under condition. Hence, it is necessary to provide standard condition of nutrient supply, pH, absence of microbial growth inhibiting substances and temperature. The strong wastes are diluted to ensure that the demand does not increase the available oxygen. A mixed group of organism should be present in the sample or the sample has to be seeded artificially. The temperature is controlled at 20oC and the test is conducted generally for 5days as 70 to 80% of the waste is oxidized during this period.BOD bottles of 300ml capacity and Incubator controlled at 20oC.
-
Preparation of dilution water:
The required volume of distilled water is prepared in a container by bubbling compressed air for 1-2 days to attain DO saturation. The temperature is maintained at 20oC. 1ml each of phosphate buffer magnesium sulphate calcium chloride and ferric chloride id added to the solution for each liter of dilution water and the solution is mixed well. In the case of the waste, which are not expected to have, sufficient bacterial population is added with a seed to the distillation water. Generally, 2ml of settled sewage is considered sufficient for 100ml of dilution water.
-
Dilution of Sample:
The sample is neutralized to pH around 7.0 .if it is highly alkaline or acidic. The sample should be free residual chlorine and if any is present it should be removed by using Na2SO3 solution as follows. 50ml of the sample is taken and acidified with addition of 10ml acetic acid. About 1g KI is now added and the mixture is titrated against Na2SO3 ( 0.025N ) using starch indicator. The volume of Na2SO3 required per ml of the sample is calculated and accordingly added to the sample. In case of samples having high dissolved oxygen content due to reasons like algae growth, the DO content is reduced by aerating and agitating the sample. Several dilutions of the prepared sample are made so as to obtain about 50% depletion of DO in diluton water but not less than 2mg with the residual oxygen after 5days of incubation not being less than 1mg/l. the second dilution water is siphoned out into a measuring cylinder or volumetric flask. The required quantity is carefully added to the mixed sample, to dilute it to the desired volume siphoning dilution water and mix well. In general, 5% to 25% dilution is suggested for treated effluent.
The diluted sample prepared is siphoned into four labeled BOD bottles and one bottle is kept for the determination of initial DO. The other three bottles are incubated at 20oC for three days. A blank is prepared in duplicate by siphoning
plain dilution water to measure the O2 consumption in dilution water. The bottle is fixed for immediate DO determination and blank by adding 2ml MnSO4 followed by 2ml of NaOH + KI + NaN3 mixture as described in the estimation of DO. Determine the DO sample in the initial and final day ( 5th Day).
BOD mg/l = ( Do D1) ( Co C1 ) mg * Decimal fraction of sample used.
Let Do = DO in the sample bottle on 0th day D1 = DO in the sample bottle on 5th day
Co = DO in the blank bottle on 5th day C1= DO in the blank bottle on 5th day
Co C1 = DO depletion in the dilution water alone Do D1 = DO depletion due to microbes.
Do C1 = DO depletion in sample dilution water
-
SOLID CONTENT ANALYSIS:
Total solids are considered to be sum of dissolved and suspended solid in the effluent. The dissolved solids usually consist of inorganic salts, small amount of organic matter and dissolved gases. The suspended solids contain much of the organic matter and any increase thereof tends to increase the degree of pollution of the effluent. TDS analysis was done by TDS meter.
Filter the required amount of effluent through a pre weighed filter paper (W1 g). Dry the paper and at 103 to 105oC and cool it in a desiccators before weighing ( W2 g) Total suspended solids ( mg/l) = ( W2-W1) * 1000 * 1000/ ml of sample (1)
A. Determination Of Kinetic Parameters
The kinetic parameters are very essential for the design of effluent treatment plant. The normal range of yield coefficient for activated sludge plant process is around 0.4 to 0.8 where as the present studies the Y is 0.5. It lies in the standard literature value. The Kd for activated sludge process is around 0.025 to 0.075d-1 the present value is
0.05 which lies in the normal range of desired parameters this clearly indicates that this process is amenable to activated sludge process.
-
RESULTS AND DISCUSSION
The existing plant in Anantapur is having capacity to handle 25,000lit/day. The milk received from nearby villages and excess buffer fat is taken out and cream, ghee is prepared. The kinetic coefficient for the activated sludge process for dairy effluent has been calculated. The normal range of yield coefficient for activated sludge plant process is around 0.4 to 0.8 where as the present studies Y is 0.5. . The Kd for activated sludge process is around 0.025 to 0.075d-1 the present value is 0.05 which lies in the normal range of desired parameters which clearly shows that the process is amenable to activated sludge process. The settled solids for the secondary settling tank are recycling to maintain MLSS 3500 mg/l. the BOD removal efficiency is 97.5% and overall plant efficiency is 93%. The reactor volume of the aeration tank is 38m3 when design from the kinetic parameters evaluated by considering actual plant waste water. This will be about 2m3 less than the actual aeration tank of the actual effluent treatment plant of the
Anantapur dairy plant. This will reduce the hydraulic retention time by 1hr. the treated effluent from the plant can be discharged. Where the discharge standard is 35mg/l. the actual plant waste characteristic is given in table 1. Which are meeting the sewage brine discharge standards but the plant will be run on typical activated sludge process as per our design. The BOD removal efficiency as per the design is above 95%.
The experimental data collected from the literature shown in the table.1.is considered for simple aeration tank with recycle.
The samples are collected for every three days to analyze characteristics of the effluent that are shown in table 2. The variation in inlet and outlet waste characteristics is shown in fig-3 and fig-4.
By using the standard data, the yield coefficient ( Y) and decay coefficient ( Kd ) are calculated by the equations below
1/c = -Y * ( rSU / X ) -Kd ( 2)
1/c = Y * ( So S )/ X – Kd (3)
S.No
S0 mg/l
BOD5
S mg/l
BOD5
= c
days
X mg
TSS/l
1
300
7
3.2
128
2
300
13
2.0
125
3
300
18
1.6
133
4
300
30
1.1
129
5
300
41
1.1
121
Table1. Experimental data for determination of kinetic coefficients.
S.No
Time in
days
pH
TSS
Inlet
BOD
Inlet
COD
Inlet
1
1
5.13
890
540
550
2
4
4.89
920
560
590
3
7
4.9
780
580
630
4
10
5.3
760
560
650
5
13
5.15
850
540
520
6
16
5.1
900
540
520
7
19
4.8
910
560
550
8
22
4.7
890
580
580
9
25
5.2
790
580
650
10
28
4.99
810
580
680
11
31
5.1
820
520
550
12
34
4.79
800
540
570
13
37
4.98
890
540
650
14
40
4.9
790
540
560
Table-2. Inlet waste characteristics
S.No
Time in days
pH
TSS
Outle t
BOD
Outlet
COD
Outlet
1
1
6.96
750
320
350
2
4
6.89
780
300
340
3
7
6.9
600
300
410
4
10
8.1
650
290
440
5
13
7.5
700
280
380
6
16
7.2
720
300
420
7
19
6.9
690
300
400
8
22
6.9
700
290
380
9
25
7.21
720
300
360
10
28
7.01
730
350
420
11
31
6.9
740
300
390
12
34
7.1
720
300
420
13
37
6.8
740
290
380
14
40
6.9
650
300
330
Table-3 The outlet characteristics
S.No
1/c d-1
( So- S) / X, d-1
1
0.313
0.715
2
0.500
1.156
3
0.625
1.325
4
0.909
1.901
5
0.909
1.946
Table-4 calculated values obtained from equation 1 and 2
Fig-1. Inlet, Outlet, pH vs Time
Fig-2. Inlet, Outlet, TSS vs Time
Fig-3.Inlet, Outlet, BOD vs Time
Fig-4.Inlet, outlet, COD vs Time
Fig-5 Determination of coefficients
-
CONCLUSION
-
The effluent character has been studied as a period of two months. The inlet BOD varied from 520mg/l to 580mg/l. the inlet pH varied from 4.9 to 5.3. The inlet TSS varied from 750 to 930 mg/L. The kinetic parameters obtained in table-4 and the values of Y is 0.5 and Kd is 0.05 from the fig-5.. The hydraulic retention time from the design calculation is 15hrs where as the actual HRT is 16 hrs.
REFERENCES
[1]. Farral, A.W. Engineering for Diary and Food Products, John Wiley and Sons Inc., new York (1963). [2].Milk processing and quality management edited by A.Y.Tamime., 2009 Blackwell publishing Ltd, ISBN: 978-1- 405- 14530-5. [3]. M. Asaduzzaman,a M.Y. Miah,b A.K.M.A. Mannan,c M. E. Haque,dA. Ara,b M.M.H. Khan,b M. Dawlatanae and M. Rahime., A Study on the Quality of Sweetened Condensed Milk Available in the Local Market of Bangladesh., Bangladesh J. Sci. Ind. Res. 42(2), 147- 156, 2007.