An Experimental Study on Compressive Strength, Void Ratio and Infiltration Rate of Pervious Concrete

DOI : 10.17577/IJERTV4IS040140

Download Full-Text PDF Cite this Publication

Text Only Version

An Experimental Study on Compressive Strength, Void Ratio and Infiltration Rate of Pervious Concrete

Gaurav Uttam Shinde Student of Final M.E. (C.M.), Dept. of Civil Engineering

Government College of Engineering, Karad, India

Dr. S. S. Valunjkar

Professor and HOD, Dept. of Civil Engineering

Government College of Engineering, Karad, India

Abstract Due to enormous improvement in construction industry and infrastructure, maximum metro cities in India are getting covered with impermeable concrete pavements. Concreting tends to environmental problems such as fall of recharge of rainwater into the ground hence continuous reduction in water table which leads to water crisis during summer. Installing Pervious Concrete pavement instead of impervious concrete for low traffic volume, we can solve the reduction of water table issue. Pervious Concrete is a low impact, environmentally friendly and sustainable paving option. Pervious Concrete is an unusual type of concrete made by the mixture of water, cement and open graded coarse aggregate. Typically it has very little to no fine aggregates content and has just enough cementations paste to coat the aggregate particle while maintaining the interconnectivity of the voids. Pervious concrete is also known as porous concrete, permeable concrete, no-fines concrete, gap graded concrete, enhanced porosity concrete. In the pervious concrete the void content is in the range of 15 to 22% compared to 3 to 5 % in conventional impervious concrete pavements.

This paper represents the experimental methodology and experimental results related to compressive strength, void content and infiltration rate. Testing various mix designs of Pervious Concrete, results were determined and analyzed. Cube size of 150mm x 150mm x 150mm is prepared to investigate compressive strength, void ratio and infiltration rate. Different concrete mix proportion such as 1:5, 1:6, 1:1:5 and 1:4:5with different size of gravels such as 9mm to 12mm should be used to check these properties of pervious concrete.

Keywords Pervious concrete pavement, compressive strength, voids ratio, infiltration rate

  1. INTRODUCTION

    Increasing in infrastructure development and resulting increase in urban storm water over the past few decades have led to increase in pollution and runoff problems. As more available land area in the major cities gets paved over, a maximum quantity of rainfall ends up falling on impermeable surfaces such as parking area, driveways, sidewalks, and highways rather than to pass into the ground. This leads to environmental issues such as erosion, decrease in ground water table, pollution of rivers, lakes, and coastal waters as rainwater flowing across pavement surfaces picks up everything from oil and grease spills and chemical fertilizers.

    One of the simple solution to avoiding these problems is to install the Pervious Concrete pavement which allows water to percolate through its pores reducing surface runoff and offering durability; unlike Conventional Concrete or asphalt pavement

    1. What is Pervious Concrete?

      Pervious Concrete is an unusual type of concrete made by the mixture of water, cement and open graded coarse aggregate, which permits rain and storm water runoff to percolate through it. It acts as a filter to trap and remove pollutants from storm water run-off. This allows the suns heat to evaporate volatile materials leaving the remaining solids to be disintegrate by microbial action.

      It is usually a mixture of 9mm to 13mm average diameter aggregate, cement, small quantity of fly ash or blast furnace slag, admixtures and water. Pervious Concrete contains voids and these voids are held together by cement paste, after the installation. A typical Pervious Concrete pavement has a 15-22% void content and allows 0.1 to 0.3 cubic meter of water per minute to pass through each square meter.

      Controlled quantity of water and cementitious materials are used to produce a paste that creates a thick coating around aggregate particles without washing off during placing, mixing and adequate compacting. Using just enough paste to coat the particles gives rise to a system of interconnected voids which further allows seepage of water through interstices. Hence it is used as a very high permeability structural concrete that drains. Pervious Concrete is also light in weight, with density between 1600 to 1900 kg/m3, because of high void content.

    2. Pervious Concrete Pavements: The Environmentally Friendly Choice

    Paved surfaces are so common in urban areas today that we do not realize the impact they have on water quality and the health of the environment. The problems include erosion, decrease in water table and pollution of rivers, lakes, and sea waters as rainwater across pavement surfaces gets mixed up with everything from oil and grease spills and artificial fertilizers.

    One of the solution to avoid these problems is to percolate natural water into the soil which can be done by Pervious Concrete. Rather than building pavements with Conventional Concrete or asphalt, Pervious Concrete – a material that offers the essential durability while retaining rain water runoff and replenishing local watershed systems should be considered.

    Mix design

    Cement

    /aggregate ratio

    Water cement

    ratio

    Remark

    M1

    1:5

    0.32

    M2

    1:6

    0.38

    M3

    1:1:5

    0.32

    1. Retarder=0.15% of cement wt.

    2. Super plasticizer= 2.5% of cement wt.

    3. Machine Mixing, Compaction by tamping rod and Vibrations

    1. Retarder=0.15% of cement wt.

    2. Super plasticizer= 0.5% of cement wt.

    3. Machine Mixing, Compaction by tamping rod and Vibrations

    1. Sand Content (1:1:5)= 6.29kg

    2. Retarder=0.10% of cement wt.

    3. Superplasticizer= 1.5% of cement wt

    4. Machine Mixing, Compaction by tamping rod and Vibrations

  2. EXPERIMENTAL WORK

    Pervious Concrete is a mixture of Cement, Coarse Aggregate / Gravel and Water. No Fine Aggregates are used for making pervious concrete. Sometimes retarders and admixtures are used to achieve adequate strength and durability of pervious concrete. In this paper, Pervious Concrete has been casted with different concrete mix proportion such as 1:5, 1:6 with 9 mm to 12 mm gravel size with OPC 53 Grade Cement.

    1. Experimental Material and Equipment Specifications

      • Cement : 53 Grade ACC cement

      • Aggregate: Aggregate size between 9mm-12mm ( passing through 12 mm sieve and retained on 10mm sieve)

      • Sand: Clean and natural

      • Water : Clean and potable water

      • Super plasticizer : Sunanda Polytancrete NTG

      • Retarder: Sugar

      • Mould : cubical mould of size 15cm x 15cm x 15cm

      • Concrete Mixer Type: Pan mixer

      • Steel tamping rod: 16mm diameter 0.6m long along with bullet ends

      • Proctor hammer: 5.1 cm diameter, height of dropping- 450 mm

      • Curing : using jute bags

        Mix design

        Cement

        /aggregate ratio

        Water

        cement ratio

        Remark

        M1

        1:5

        0.32

        1.Hand Mixing, Compaction by

        taming rod , No Vibrations

        M2

        1:6

        0.38

        1.Hand Mixing, Compaction by

        tamping rod , No Vibrations

        M3

        1:1:5

        0.32

        1. Hand Mixing, Compaction by tamping rod , No Vibrations

        2. Aggregate size between 10mm to 12mm

      • Compressive strength testing machine

    2. Trial mix

      In this chapter different mix designs and various test performed on Pervious Concrete are presented. Further effects of admixtures and retarders as well as different curing methods are presented.

      Trial No. 1

      Table 1 Trial No.1 Mix Design

      Note: weight of cement is 6.29 kg, number of cube are 3 and sugar is used as a retarder.

      Trial No.2

      Table 2 Trial No.2 Mix Design

      Note: Weight of cement is 4.49 kg, number of cube are 2

      Trial No.3

      Table 3 Trial No.3 Mix Design

      Mix design

      Cement

      /aggregate ratio

      Water cement

      ratio

      Remark

      M1

      1:5

      0.32

      1.Hand Mixing, Compaction by tamping

      rod and Proctor hammer No Vibrations

      Note: Weight of cement is 4.49kg, number of cube is 1.

      Trial No.4

      Mix design

      Cement/Aggregate ratio

      Water cement

      ratio

      Remark

      M1

      1:4:5

      0.34

      1.Hand Mixing, Compaction by tamping

      rod and Proctor hammer No Vibrations

      Table 4 Trial No.4 Mix Design

      Note: Weight of cement is 4.49kg, number of cube is 1.

    3. Test Performed

      1) Compressive Strength Test

      1. To make sure that Pervious Concrete cube is watertight; it is further wrapped up with tape covering all its vertical faces and bottom face.

      2. Cube covered on its five faces and open at top face is placed on a flat horizontal surface and water is poured from the top.

      3. To make sure that covering polythene does not expand due to lateral pressure of water it is pressed by hands while water is being poured. Water is poured till all the voids are filled and water surface matches with the top

        face of Pervious Concrete.

      4. Once pouring of water is stopped and all voids are filled, Pervious Concrete is turned upside down and all the water is allowed to drain out of Pervious Concrete cube and collected into a container.

      5. Volume of water collected in container is measured and it is equal to the volume of voids in cube, using it and volume of Pervious Concrete cube, void ratio is found out.

      6. Void ratio = volume of voids/volume of cube x 100.

      3) 3 Infiltration Rate

      The infiltration Rate of Pervious Concrete is measured on 6th day and 27th day after casting of Pervious Concrete in following steps:

      The most common of all test on hardened concrete is a 1. Pervious Concrete cube is placed in a polythene bag such that

      compressive strength test, because it is an easy test to

      perform, and also because many of the desirable characteristic of concrete are qualitatively related to its

      top circumference of cube and that of polythene bag coincide; polythene bag is selected such that its length is more than three times that of Pervious Concrete cube.

      strength but mainly because of the intrinsic importance of 2. After placing cube in a polythene bag such that its

      compressive strength of concrete in structural design. The strength test results may be affected by variation in type of test specimen; specimen size; type of mould; curing; preparation of the end surfaces; rigidity of testing machine and rate of application of test.

      In the compression test, the cube, while still wet, is placed with cast faces in contact with platens of the testing machine,

      i.e. the position of cube when tested is at right angles to that as-cast. The load on cube should be applied at a constant rate

      circumference and that of bag coincide it is wrapped up in the bag covering all its vertical faces with the help of tape and leaving top face open outside, bottom face open inside the bag and care is also taken to make sure that covering around cube is watertight. Remaining length of the polythene bag which is not wrapped around Pervious Concrete cube is kept free to contain water which would be poured in from top face and percolate through Pervious Concrete cube and fall into free part of bag through bottom face.

      of stress equal to 0.2 to 0.4MPa/sec. Compressive strength is 3. Measured volume of water (approx. 6-8 liters.) is poured in

      also known as crushing strength.

      In case of Pervious Concrete, cubes are kept for curing under

      from top face into the polythene bag through Pervious

      Concrete cube.

      wet jute bags or immersed in water till for 28 days. 4. After pouring is completed polythene bag with Pervious

      Compressive strength test is carried out at the age of 7th day, 14th day and 28th day. The compressive strength test is carried out under compressive testing machine

      The failure pattern of cube is observed and results of

      Concrete cube inside it is turned upside down and all the water inside it is allowed to percolate through Pervious Concrete cube and time is measured required for draining out all the water.

      compressive strength of Pervious Concrete cube are 5. With the help of measured volume of water, time required for

      presented in chapter below. Specimen stored in water shall be tested immediately on removal from water and while they are still in wet condition.

      2) 2 Void Ratio

      The void ratio of Pervious Concrete is measured on 6th

      draining out all the water and cross sectional area of cube Infiltration rate of Pervious Concrete is found out.

      1. Infiltration rate = Measured volume of water (in L)/ C/S area of cube (in m2)/ time

        Required for draining out entire vol. of water (in min.)

        day and 27th day after casting of Pervious Concrete in following steps:

        1. Pervious Concrete cube is wrapped up with polythene covering all its vertical faces and bottom face and leaving only the top face open.

    4. EXPERIMENTAL RESULT

      Trial No.1

      Mix Design

      Compressive Strength (Mpa)

      Void ratio (%)

      Infiltration rate (l/min/m2)

      7th day

      14th

      day

      28th day

      M1

      5.23

      6.65

      6.87

      5.7

      259

      M2

      6.18

      6.64

      7.89

      5.9

      285

      M3

      8.88

      15.6

      19.46

      6.2

      300

      Table 5 Trial No.1 Mix Design Results

      Trial No.2

      Mix Design

      Compressive Strength (Mpa)

      Void ratio

      (%)

      Infiltration rate

      (l/min/m2)

      7th day

      14th day

      28th day

      M1

      5.55

      6.23

      7.43

      19.97

      1512

      M2

      7.46

      7.58

      7.84

      20.47

      1864

      M3

      9.33

      11.26

      14.10

      14.67

      1239

      Table 6 Trial No.2 Mix Design Results

      Trial No.3

      Mix Design

      Compressive Strength (Mpa)

      Void ratio

      (%)

      Infiltration rate

      (l/min/m2)

      7th day

      14th

      day

      28th day

      M1

      13.42

      13.8

      14.11

      14.47

      939

      Table 7 Trial No.3 Mix Design Results

      Trial No.4

  3. CONCLUSION

An experimental study evaluating strength and permeability characteristics of a pervious concrete mix design is presented. The experimental work included compressive strength tests, void ratio and infiltration rate test on clean specimens. The experiments were performed on specimens of size 150mm x150mm x150 mm cube.

    • For a particular mix examined, compressive strength ranges between 4MPa and 19MPa with an average of about 12MPa.

    • Similarly void ratio ranges between 6% to 20% with an average of about 14%

    • Infiltration rate ranges between 300 l/min/m2 and 1900 l/min/m2 with an average of about 1200 l/min/m2.

    • Overall it is observed that when void ratio increases, infiltration rate also increases and compressive strength decreases and vice versa.

    • Strength of Pervious concrete is less than that of conventional concrete of nearly same mix design but pervious concrete has very high degree of permeability as compared to conventional concretes which is nearly zero.

Table 8 Trial No.4 Mix Design Results

Mix Design

Compressive Strength (Mpa)

Void ratio

(%)

Infiltration rate

(l/min/m2)

7th day

14th day

28th day

M1

11.65

13.42

13.64

17.86

1312

REFERENCES

  1. Darshan S. Shah, Prof. J.R.Pitroda, Pervious Concrete: New Era for Rural Road Pavement, International Journal of Engineering Trends and Technology (IJETT) ISSN No. 2231-5381, Volume: 4, Issue: 8, August 2013, Page: 3496 3500

  2. Darshan S. Shah, Prof. J.R.Pitroda, Assessment for use of Gravel in Pervious Concrete, International Journal of Engineering Trends and Technology (IJETT) ISSN No. 2231-5381, Volume: 4, Issue: 10, Octomber 2013, Page: 4306 – 4310

  3. Khalfan, M. M. A., (2002) Sustainable Development & Sustainable Construction, Southborough University http://www.c- sand.org.uk/Documents/WP2001-02 Sustain Lit Rev.pdf Accessed: 25th June 2008

  4. Sneha Sanjay Ganpule, S. V. Pataskar (2011),Use of Porous Concrete as a Green Construction Material for Pavement International Journal of Earth Sciences and Engineering, ISSN 0974-5904, Volume 04, No 06 SPL, October 2011, pp. 764-767

  5. Milani S. Sumanasooriya a, Narayanan Neithalath b,.Cement & Concrete Composites. a Department of Civil and Environmental Engineering, Clarkson University, Potsdam, NY 13699, United States : s.n., Available online 17 June 2011.

  6. Yang, J., and Jiang, G. (2003), Experimental Study on Properties of Pervious Concrete Pavement Materials. Cement and Concrete Research, V. 33, p. 381-386