Torsional Effect on Multi-Storeyerd Buildings with Water Tanks Due to the Seismic Forces by using Sap 2000 Software

DOI : 10.17577/IJERTV3IS120631

Download Full-Text PDF Cite this Publication

Text Only Version

Torsional Effect on Multi-Storeyerd Buildings with Water Tanks Due to the Seismic Forces by using Sap 2000 Software

Archana Kotte Dr. G. Sudarsana Rao

Student At JNTUA College of Engineering, Professor & Rector of JNTUA Civil Engineering Department Civil Engineering Department

Ananthap,uramu JNTU College of Engineering

Andhra Pradesh Ananthapuramu,

IND. IA

Andhra Pradesh INDIA.

Abstract Many multi-storeyed buildings tend to have irregular features in configuration, which are not suitable for the buildings to resist the forces generated during an earth quake. The presence of heavy roof top masses like water tanks, air handling units, swimming pools etc., increases the seismic forces in the members of a building .The present study compares the forces in the columns of a few building models which have the water tanks supported on columns considerably above the roof level.

Elevated tanks are important structures in storing vital products, such as petroleum products for cities and industrial facilities, as well as water storage. These structures have various types and are constructed in a way that a greater portion of their weight is concentrated at an elevation much about the base. Damage to these structures during strong ground motions may lead to fire or other hazardous events. The liquid mass of the tank will modelled as lumped mass known as sloshing mass, or impulsive mass. The corresponding stiffness constants associated with the lumped mass will be determined depending upon the properties of the tank wall and liquid mass. Tank responses including base shear, overturning moment, tank displacement, and sloshing displacement will also be calculated.

Two models for the same building will be developed by changing the position of the tank one placed eccentrically and another placed by splitting equally and located symmetrically. The forces in the columns will be obtained for both the cases.

Index Terms normal building, building with empty weight, building with full water weight

INTRODUCTION:

Elevated tanks are important structures in storing vital products, such as petroleum products for cities and industrial facilities, as well as water storage. These structures have various types and are constructed in a way that a greater portion of their weight is concentrated at an elevation much about the base. Damage to these structures during strong ground motions may lead to fire or other hazardous events. In the research , a reinforced concrete elevated tank, with 900 cubic meters capacity, exposed to

three pairs of earth quake records was analyzed in time history using mechanical and finite element modeling techniques. The liquid mass of the tank was modeled as lumped mass known as sloshing mass, or impulsive mass. The corresponding stiffness constants associated with the lumped mass were determined depending upon the properties of the tank wall and liquid mass. Tank responses including base shear, overturning moment, tank displacement, and sloshing displacement were also calculated. Obtaining results revealed that the system responses are highly influenced by the structural parameters and the earthquake characteristics such as frequency content

SAP 2000 represents the most sophisticated and user- friendly release of the SAP series of computer programs. When initially released in 1996, SAP2000 was the first version of SAP to be completely integrated within Microsoft Windows. It features a powerful graphical user interface that is unmatched in terms of ease- of-use and productivity. Creation and modification of the model, execution of the analysis, and checking and optimization of the design, and production of the output are all accomplished using this single interface. A single structural model can be used for a wide variety of different types of analysis and design

RESEARCH SIGNIFICANCE:

Proper configuration and design of the structural members are essential for the safety of a building against seismic forces. Though the placement of heavy water tanks above the roof level is a functional requirement and may not be critical for a building in terms of resisting gravity loads, it increases vulnerability of some columns in the building for seismic forces, especially if they were not adequately designed for seismic forces.

The results from the present study quantify the vulnerability in terms of the torsion in the multi-storeyed building. The study helps in creating awareness in the design of such buildings located in earthquake prone areas. Such type of investigation is

necessary where the water distribution to the individual apartments /offices in a multi-storied building is based on gravity flow from the roof tanks

Design of building with gravity loads:

Two ten storied building was considered. In that building one which is having 5 panels in x direction and 5 panels in y direction which are of 5m length. In this here it has fixed moments at the bottom floor that is ground floor. In that building two which is having 6 panels in X direction and 4 panels in Y direction which are of 5m length.

Second building was taken into consideration for middle placing of the water tank for getting the accurate results. Then the earthquake loads and gravity loads are applied for empty tanks. Then gravity loads and earthquake loads are applied for the full water tank.

Dimensions:

Building no 1:

Model 1A:

plan elevation

Model 1B:

These are the dimensions of the building which is having 5 bays in x direction and 5 bays in y direction which are of length 5m in both x and y direction.

Model 1C:

No of stories

10

Story height

350mm

Characteristic strength of

Concrete

M30

Characteristic strength of steel

Fe 415

Beams in X direction

300×400 mm

Beams in Y direction

300×300 mm

External columns

600x 600 mm

Internal columns up to 4th floor

900x 900 mm

Internal columns above 4th floor

550x 550 mm

Dead load

1.5KN/ sq.m

Live load on slab

1 KN/sq.m

Live load on remaining floors

3 KN/sq.m

plan elevation

Model 1A: Normal building with 5 x 5 bays and each bay length is 5m

Model 1B: Building with water tank dimensions 5m x 5m x 3.5m at the eccentric position

Model 1C: Building with tank dimensions 10m x 10m x 3.5m at the eccentric position

Model 1D: Building with tank 10m x 10m x 3.5m at the eccentric position close to the centre of building

plan elevation

Model 1D:

change in weight will be same but the change in torsion is more. This means by changing the position of the tank we can get the change in percentage of torsion

Here we can observe that the torsion is more in the tank placed near to the central position then the tank placed at the eccentric position.

Building no 2:

We constructed another building with

plan elevation

By using SAP2000 we constructed these symmetrical building with 5×5 bays with 5 m length each and we checked the stability of the structure by designing. We calculated the area of steel (AST) of the building for the economical calculations we got. For each model we calculate he AST of beams and columns of models separately and we will add those both and this is the model 1A are shown and all the models are done like that only

Ast of beams as 2.654 m2 Ast of columns as 11.58 m2

Total ast of building is 14.234 m2 Calculation of Torsion:

Building

Weight (KN)

%change in weight

Torsion (KN-m)

%change in torsion

Model 1A

100921

———

3860

———-

Model1B

101174

0.25%

4277

9.75%

Model 1C

102090

1.15%

4330

10.8%

Model 1D

102090

1.15%

4518

14.5%

Here we have the bar graph between the % change in weight and % change in torsion shows us the clear variation between them

20

15

10

5

weight

Torsion

0

Model Model Model Model

1A 1B 1C 1D

Here we have come to know from the above table that for model 1C and model 1D %

horizontal 6 and vertical 4bays and with length and breadth area of 6m X 4m and we designed it by using sap2000 because the central position of the building can be fixed at the central if the building has non symmetrical bays. The data of the building is

Dimensions :

No of stories

10

Height of the storey

350 mm

Beam dimension

600 x 400 mm2

Dimension of column 1

700 x 700 mm2

Dimension of column 2

600 x 600 mm2

Dead load

1 KN/m2

Live load on terrace

1 KN/m2

Live load on remaining floors

2.5 KN/m2

Characteristic strength of

concrete

M30

Characteristic strength of steel

Fe 415

Model 2A: normal building with 6 x 4 bays and each bay length is 5m

Model 2B: Building with water tank dimensions 10m x 10m x 5m at the eccentric position

Model 2C: building with water tank dimensions 10m x 10m x 5m at the centre of building

These are the figures which can be shown the different models which are stated above

By using SAP2000 we constructed these symmetrical building with 6 x 4 bays with 5m length each and we checked the stability of the structure by designing.

We calculated the torsion of a building by placing water tanks at different positions on the roof of a building and we compared with the torsion in normal building without any tank.

Model 2A:

Calculation of Area of Steel and Concrete:

Build ing

Weig ht (KN)

%change in weight

Area of steel AST(

m2)

%

chang e in AST

Area of concre te ASC

%

cha nge in AS

C

Mode l 2A

1087

75

———

2.82

——–

875.7

97

—–

—–

Mode

1267

16.5%

3.487

23.65

1085.

24.0

l 2B

29

%

945

5%

Mode

1271

16.8%

3.490

23.75

1145.

30.8

l 2C

54

%

465

%

Model 2B:

plan elevation

By using this tabular form we will a draw a graph which gives a clear comparison between different models and their values. And that bar graph is shown below

35

30

25

20

15

10

5

0

weight

AST ASC

Model 2A Model 2B Model 2C

Calculation of Torsion:

Model 2C:

plan elevation

Building

Weight (KN)

%

change in weight

Torsion (KN-m)

% change in torsion

Model

2A

108775

———

1115

———–

Model 2B

126729

16.5%

1180

5.83%

Model 2C

127154

16.8%

1256

12.64%

By using this tabular form we will a draw a graph which gives a clear comparison between different models and their values. And that bar graph is shown below

plan elevation

20

15

10

5

Weight

Torsion

0

Model 2A Model 2B Model 2C

Here whether the percentage change in weight in buildings is same but due to the position of the water tank the %change in torsion is different.

Design of building with gravity loads and earthquake loads (IS1893-2002):

Earthquake can cause damage not only on account of the shaking which results from them but also due to other chain effects like landslides, floods, fires and disruption to communication. It is, therefore, important to take necessary precautions in the sitting, planning and design of structures so that they are safe against such secondary effects also.

Here we consider the zone III for medium soils we have done

Assumptions:

Calculation of Area of steel:

Buildin g

Weigh t

(KN)

%change in weight

Area of steel AST(m2

)

% change in AST

Model

2A

108775

———–

—-

2.92

————

—-

Model

2B

126729

16.5%

3.96

35.16%

Model

2C

127154

16.8%

4.10

40.41%

By using this tabular form we will

The following assumptions shall be made in the earthquake resistant design of structures:

  1. Earthquake causes impulsive ground motions, which are complex and irregular in character, changing in amplitude and period each lasting for a small duration. Therefore, resonance of the type as visualized under the type as visualized under steady- state sinusoidal excitations, which will not occur as they would need time to build up such amplitudes.

  2. Earthquake is not likely to occur simultaneously with maximum flood or wind or maximum sea waves.

  3. The value of elastic modulus of materials, wherever required, may be taken as for static analysis unless a more definite value is available for use in such condition

    a draw a graph which gives a clear comparison between

    different models and their values. And that bar graph is shown below

    20

    15

    10

    5

    Weight

    Torsion

    0

    Model 2A Model 2B Model 2C

    In the limit state design of reinforced and pre stressed concrete structures, the following load combinations shall be accounted for:

    1) 1.5 (DL + IL)

    2) 1.2 (DL + IL+ EL)

    3) 1.2 ( DL + IL EL)

    4) 1.5 (DL EL)

    5) 1.5 (DL + EL)

    6) 0.9 DL + 1.5EL

    7) 0.9 DL 1.5EL

    Building

    Weight (KN)

    % change in weight

    Torsion

    %

    change in torsion

    Model 2A

    108775

    —————

    4950

    ———–

    Model 2B

    126729

    16.5%

    5376

    8.64%

    Model 2C

    127154

    16.8%

    5575

    12.62%

    Calculation of Torsion:

    The bar graph is drawn showing

    Model Designing:

    We constructed model 2

    the variation in the % change of weight and the % change of torsion from table 6

    building with horizontal 6 and vertical 4bays and with

    No. of stories

    10

    Height of the storey

    350mm

    Beam dimensions

    600 mm x 400 mm

    Dimensions of column 1

    700 mm x 700 mm

    Dimensions of column 2

    600 mm x 600 mm

    Dead load

    1 KN/m2

    Live load

    2.5 KN/m2

    Characteristic strength of

    concrete

    M30

    Characteristic strength of steel

    Fe 415

    length and breadth area of 5m X 5m and we designed in such a way that we applied all the load combinations and the earth quake forces according to IS 1893: 2002 specifications by using sap2000. The data of the building is

    20

    15

    10

    5

    Weight

    Torsion

    0

    Model 2A Model 2B Model 2C

    Building with gravity loads, earthquake loads (IS 1893-2002) and hydrodynamic loads (IITK-GSDMA GUIDELINES):

    Water consumption rate( per capita demand in litres per day per head)with which people should be survived

    Quantity = per demand x population

    It is very difficult to estimate the quantity of water demand by the public, since there are many variable factors affecting the water consumption. The various types of water demands, which a city may have, may be broken into following class

    S.NO

    TYPES OF CONSUMPTION

    NORMAL RANGE

    (lit/capita/day)

    AVERAGE

    %

    1.

    Domestic

    Consumption

    65-300

    160

    35

    2.

    Industrial and

    commercial demand

    45-450

    135

    30

    3.

    Public Including

    fire Demand uses

    20-90

    45

    10

    4.

    Losses and Waste

    45-150

    62

    25

    Load combinations:

    The load combinations according to IS 1893:2002 is taken for seismic forces and these are the combinations when hydro dynamic load is present in the tank (or) when the tank is empty.

    100% + 30% rule implies following eight load combination

    Weight Calculations:

    Component

    Calculations

    Weight (kN)

    Roof slab

    (5×5)x0.25x25x4

    625

    Wall

    2x(5+0.6)x0.25x25x2.4

    168

    Floor slab

    (5×5)x0.25x25x4

    625

    Floor beam

    2x(5+0.6)x0.25x(0.4-0.25)x25

    10.5

    Columns

    (0.6×0.6)x5.4x4x25

    194.4

    water

    (10×10)x2x9.81

    1962

    Elevation of tank

    1. ( ELX + 0.3ELY)

    2. ( ELX + 0.3ELY);

    3. (0.3ELX + ELY);

    4. (0.3ELX + ELY)

    5. ( ELX 0.3ELY)

    6. (ELX 0.3 ELY)

    7. ( 0.3ELX ELY)

after that we will find out Spring Mass Model for Seismic Analysis for the water tank by using IITK-GSDMA guidelines which are specified for the water tank designs.

Preliminary Data:

Component

Size (mm)

Roof slab

250

Wall

250

Floor slab

250

Floor beams

600 x 400

columns

600 x 600

Slab of the tank above the columns

According to IITK-GSDMA guidelines we will find out lateral stiffness of staging, time period, design horizontal seismic coefficient, base shear, base moment, hydro dynamic pressures, pressure due to wall inertia, pressure due to vertical excitation, sloshing wave height and the remaining which we need for us.

Calculation of Area of Steel:

Building

Weight (KN)

%change in weight

Area of steel AST(m2)

%

change in AST

Model 2A

108775

————–

2.92

———–

Model 2B

136293

25.29%

4.48

53.42%

Model 2C

137485

26.39%

4.53

58.13%

By using this tabular form we will a draw a graph which gives a clear comparison between different models and their values. And that bar graph is shown below

80

60

40

20

0

weight

AST

MODEL 2A MODEL 2B MODEL 2C

Calculation of Torsion:

Buildin g

Weight (KN)

% change in weight

Torsion (KN-m)

% change in torsion

Model 2A

108775

———–

4950

————

Model 2B

136293

25.29%

5896

19.1%

Model 2C

137485

26.39%

6018

22.6%

The given graph represents the above table which compares between weight and torsion. By using this tabular form we will a draw a graph which gives a clear comparison between different models and their values. And that bar graph is shown below

BUILDING WITH WATER TANK DIVIDED INTO TWO TANKS OF EQUAL SIZE

No. of stories

10

Height of the storey

350 mm

Beam dimensions

600 mm x 400 mm

Column 1

700 mm x 700 mm

Column 2

600 mm x 600 mm

Dead load

1 KN/m2

Live load on Terrace

1 KN/m2

Live load on remaining floors

2.5 KN/m2

Characteristics strength of

concrete

M30

Characteristic strength of steel

Fe 415

Here we have taken a 6 bays in x direction and 4 bays in y direction and we place the water tank of size 10 m x 10 m x 3.5 m is divided into two tanks of 5 m x 5 m x 3.5 m size and we placed them near to centre on the roof of building

Model 2D: The building with 6 bays of length 5m in x direction and 4 bays of length 5m in y direction and the tank is divided into two and distributed on the roof

Calculation of torsion:

building

weight

% change in weight

Torsion

% change in torsion

Model 2B

136293

————–

5896

————-

Model 2C

137485

0.87%

6018

2.07%

Model 2D

139025

2.00%

3585.3

-39.19%

Dimensions:

As we know that as the weight increases on

the roof of the building torsion increases from previous chapters but here we are doing how the torsion will vary when the heavy tank is divided in to the tanks of small volume and

thats why we divided here the 10 m x 10 m x 3.5 m tank into two tanks of volume 5 m x 5 m x 3.5m

Here below the table represents the dimensions of the building which we are taking. Here we consider model 2C which is having centrally constructed over head tank and the thing which is having more torsion when compared to other buildings.

In the tanks are divided the torsion value is decreased very much compared to total mass of the tank present at one place. This represents the uniform distribution of the mass on the roof of the slab

Above is the graph which represents the comparison between weight and the torsion for the 3 models

40

20

0

-20

model 2b model 2c model 2d

weight

torsion

-40

-60

The seismic forces on the ground floor will be more when compared to the top floors because the columns will affect more than the beams in each floor.

When we the tank is divided symmetrically on either side from the centre of the building the load will be distributed uniformly to the whole building then the affect of seismic forces on the columns will become less.

CONCLUSIONS:

  1. From the design we conclude that the columns below the water tank are more affected especially from ground level to top floors.

  2. Change in the weight of a building not only gives the change in torsion but also position of the extra mass also shows change in torsion

  3. Change in torsion is more when we place the extra mass at the centre then at the eccentric position

  4. When we keep extra mass at the centre then the central frame of the whole building will not show any torsional values that means the torsion at the central frame is zero

  5. Torsion is more in YZ direction then in XZ direction of building.

  6. When the tank is splitted equally into on either side of the building as shown in fig the torsion is decreased very much compared to the eccentric and central position of the building

  7. In the presence of a heavy roof top water tank, the columns in the ground storey supporting the water tank experience the maximum increase of seismic forces. The situation can be critical for the columns in an open ground storey, when walls are absent for facilitation of parking or other usage.

  8. The sloshing effect of water was found to be small for the size of the tank relative to the building. Hence, it can be neglected in the analysis for the member forces in a building

  9. The elevation of heavy roof-top water tanks is significant with respect to the concentration of internal forces in the supporting columns. Hence, the elevation should be accounted for in the analysis of a building for seismic forces

  10. The seismic forces in the columns increase when the tank is eccentrically located or centrally located in the plan of building. The forces are reduced when the tank is split equally and positioned symmetrically in plan

REFERENCES:

  1. IITK-GSDMA guidelines for seismic design of liquid storage tanks (2007), Indian Institute of technology Kanpur and Gujarat state Disaster Management Authority.

  2. IS 1893, Indian Standard criteria for Earthquake Resistant Design of structures, Part 1 (2002): General provisions and buildings, part 2 (Draft):

    Liquid Retaining Tanks, Bureau of Indian standards, New Delhi.

  3. IS 13920: 1993, Ductile detailing of Reinforced concrete Structures Subjected to seismic forces , Bureau of Indian standards New Delhi.

  4. Manual on Water Supply Treatment (1999), Central public health and environmental engineering Organisation, Government of India

  5. Housner, G.W. (1963), The Dynamic behaviour of Water tanks , Bulletin of the seismological society of America vol.53, No.2,pp.381-387

  6. Jojy, 1, (2011), Effect of Heavy Roof- Top water tanks on the seismic Forces in a typical multi storied Building, B. Tech, Project report submitted to Indian Institute of Technology Madras.

Leave a Reply