- Open Access
- Total Downloads : 757
- Authors : Cornelius Joseph, Kolawole Rasheed Onifade, John Sylvester Lebnebiso, Adejoh Adu Zakariah
- Paper ID : IJERTV4IS061043
- Volume & Issue : Volume 04, Issue 06 (June 2015)
- Published (First Online): 20-07-2015
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Development of a Computer Software for Design of Packed Absorption Column
1Cornelius Joseph , 1John Sylvester Lebnebiso
1Department of Chemical Engineering, School of Engineering and Engineering Technology,
Modibbo Adama University of Technology,
P.M.B 2076, Yola, Adamawa State, Nigeria.
2 Kolawole Rasheed Onifade Professor
2Department of Chemical Engineering, School of Engineering and Engineering Technology,
Federal University of Technology, Minna, Niger State, Nigeria.
3Adejoh Adu Zakariah
3Department of Chemical Engineering, Faculty of Engineering, University of Abuja, Abuja, Nigeria
.
Abstract – A Computer Aided-Design (CAD) module was developed for the design of packed gas absorption column. The program was tested using a problem statement by supplying specifications such as operating conditions (pressure, temperature), physical properties (density, viscosity, surface tension), the solute to be absorbed, the solvent selected, gas and solvent mole fractions, percentage flooding velocity, pressure drop, gas flow rate ,packing type and size. The design parameters calculated agreed with those obtained from manual solution, with a correlation coefficient of 1.000. The specifications above were varied to obtain the design outputs within the shortest possible time. For example, operating pressure of 760 mmHg, operating temperature of 300C, gas flow rate of 0.126kg/s, flooding velocity of 50%, pressure drop of 21 mm H2O/m of packing, and 0.025m raschig ring ceramic packing gave the following design parameters: cross-sectional area of 0.6209431 m2, column diameter of 0.8891045 m, packing height of 2.743771 m, surface area of 22.35612 m2, tower height of 7.558167 m, and volume of packing of 1.703726 m3
Key Words: Packed column, gas absorption, design, software, CAD.
1.0 INTRODUCTION
A gas absorption column is a vertical cylinder in which liquid and gas are contacted. The packed columns are commonly used and the feed to the columns can be binary or multicomponent. The columns are characteristically operated with counter-flow of the gas and liquid. Countercurrent designs provide the highest theoretical removal efficiency because gas with the lowest solute concentration contacts liquid with the lowest solute concentration. This serves to maximize the average driving force for absorption throughout the column (Mclnnes et al., 1990). Moreover, countercurrent designs usually require lower liquid to gas ratios than co-current and are more suitable when the solute loading is higher (Jose L. Bravo, personal communication June 8, 1992).
Gas absorbers are used extensively in industry for separation and purification of gas streams, as product recovery devices, and as pollution control devices. Gas
absorbers are most widely used to remove water soluble inorganic contaminants from gas streams (Mclnnes et al., 1990).
Absorption is a process where one or more soluble components of a gas mixture are dissolved in a liquid (i.e. a solvent). The absorption process can be categorized as physical or chemical. Physical absorption occurs when the absorbed compound dissolves in the solvent; chemical absorption occurs when the absorbed compound and the solvent react. Liquids commonly used as solvents include water, mineral oils, nonvolatile hydrocarbon oils and aqueous solutions (http://www.pdnengineers.com Retrieved February, 2011).
The following factors are usually considered for optimum design an absorption column:
-
The best solvent for the operation
-
The column diameter to handle the gas flow and liquid flow up to flooding point.
-
The height of the column and its internal members e.g the height and type of packing.
-
Selection of the type and size of packing.
-
The optimum operating conditions (temperature and pressure).
-
The mechanical accessories of the column, e.g packing support, liquid distributor and re-distributor.
Economic design specifications include:
-
The gas flow rate.
-
The gas composition at least with respect to the component to be absorbed.
-
Operating pressure, temperature and allowable pressure drop.
-
The minimum degree of recovery of one or more solutes.
-
The solvent to be used and the type and size of packing.
A comprehensive review of gas absorption and packed column design can be found in many units operations books (Richardson and Coulson, 2004 and 2009; Brunazzi et al., 2002; Perry and Green, 1997; Mclnnes et al., 1990;
Ayoade, 1994; McCabe, Smit and Harriott, 1993; Coker, 1991; Treybal, 1981 and http://www.pdnengineers.com
Retrieved February, 2011).
Computer Aided Design (CAD) is a utility that exploits the capabilities provided by computers for speedy processing of design procedures. It enables the engineers to solve large and complex design problems much more faster and accurately than hitherto. The evolution, types structure, components and advantages of CAD are well detailed (Onifade, 2000 and Oguntoyinbo, 1993).
This work makes use of a CAD module, a high level language program of the procedure required for the design of packed absorption column. Thus it is an assembly of a set of mathematical equations and the techniques for solving them. The main program draws relevant information/data from a database of phase equilibria; and physical, chemical and thermodynamic properties.
The aim of this work is to develop a computer software for design of packed gas absorption column using a Computer Aided-Design module and to investigate the effects of the operating variables on the design parameters.
-
METHODOLOGY
-
Development of program (software)
The design procedure implemented in the CAD module is based on the following assumptions:
-
The gas is assumed to comprise a two-component gas mixture (solute/air), where the solute consists of a single compound present in dilute quantities.
-
The gas is assumed to behave as an ideal gas and the solvent is assumed to behave as an ideal solution.
-
Heat effects associated with absorption are considered to be minimal for the solute concentrations encountered.
-
Chemical reaction does not occur.
-
The system is assumed to be isothermal.
-
The equilibrium curve is assumed to be linear since the process fluids are dilute.
(e) The molar flow rate of the solute-free gas is assumed to be constant throughout the column.
The flowchart for implementing the CAD module for absorption column design is shown in Figure 1.
The program was developed using Visual Basic language because of its user- friendliness, easier comprehension, and faster application development.
Start
Input design problem specifications: solute, gas, solvent operating T & P, etc
Calculate the physical properties , , etc.
Obtain the equilibrium curve equation from the equilibrium data
Calculate the number of overall gas transfer units, NOG
Select the packing type, material and size
Calculate column cross-sectional area, diameter and ratio of packing size to
Is the ratio > 8?
yes
No
Calculate overall height of transfer unit, HOG (Using Ondas method) packing height, column height and surface area
Output the design parameters
Stop
Figure 1: Flowchart for implementing CAD module for absorption column design
The Visual Basic 6.0 program Icon was double clicked to open ew forms. Text boxes and combo boxes were laid out on the screens for imputing and selecting the design specifications and were labelled appropriately. Command buttons were also placed on the forms for giving appropriate commands for obtaining equilibrium curve equation, calculating the pertinent design parameters of the packed absorption column, generating report, up-dating record, adding record to data base and for exiting the
application and were labelled appropriately. All the equations, data and correlations for obtaining equilibrium curve equation and the design parameters of the packed column were then coded in the code window. The codes for generating report, updating record, adding record to data base and for exiting the application were also coded in the code window. A typical graphical user interface (GUI) and an output screen are shown below.
Figure 2: Graphical User Interface for Obtaining Equilibrium Curve Equation.
Figure 3: A Typical Output Screen
-
-
The Test Problem
The CAD module was tested using the following problem. A gas mixture containing 6% SO2 and 94% dry air is to be scrubbed with fresh water in a tower packed with 0.025m ceramic raschig rings to remove the SO2 so that the exit will contain no more than 0.1 mole percent SO2, that is, recovery of about 98.333%. The tower must treat 0.126kg/s of gas and is to be designed using 50% of flooding velocity. The water flow is to be twice the minimum required to achieve this separation in a tower operating at 300C and 760mmHg or 1 atm. Determine the tower diameter, cross-sectional area, packing height, volume of packing, column height and surface area.
-
Program run
The following important set of screens were used.
-
Design specification screens
These series of screens are used for inputting the following information:
-
Solute gas
-
Solvent
-
Pressure drop (mmH2O/m of packing)
-
Percentage of flooding rate (50-75%)
-
Gas flow rate (0.126-0.504 Kg/s)
-
Operating temperature ( 00C-300C)
-
Mole fraction of the solute in the gas entering the column
-
Mole fraction of the solute in the gas exiting the column
-
Mole fraction of the solute in the liquid entering the column
-
Adjustment factor
At this point the module displays the operating line equation
-
-
A screen comes up for inputting the packing type, packing material and size. The module calculates the pertinent design parameters (diameter, cross- sectional area, packing height, surface area, and height) of the absorption column.
-
After a series of screens which include one for generating the result, updating record and adding record to data base, the final output screen is displayed. A typical output screen is shown in figure 3.
-
RESULTS AND DISCUSSION
-
CAD Module Output.
The results of the manual calculations and those from CAD module are shown in Table 2 while the operating variables for obtaining the design parameters are shown in Table 1. Tables 3-7 summarise the various outputs obtained from the program using different specifications.
Table 1: Operating variables for obtaining the design parameters.
Operating Variable
Value
Temperature (0C)
30
Pressure Drop (mm H2O /m of Packing)
21
Flooding Velocity (%)
0.5
Gas Flow Rate (Kg/s)
0.126
Packing Type and Size(m)
Rachig Ring Ceramic (0.025)
Table 2: Results from manual calculations and CAD program for the problem statements.
Design parameters
Manual calculations
CAD output
Cross sectional area (m2)
0.621
0.621
column diameter (m)
0.89
0.889
Packing height (m)
2.73
2.74
Surface area (m2)
22.3
22.36
Volume of packing (m3)
1.7
1.7
Tower height ( m)
7.54
7.56
Correlation coefficient
1
1
Table 3: Output from the program using operating pressure of 760 mmHg, gas flow rate of 0.126kg/s, flooding velocity of 50%, pressure drop of 21 mm H2O/m of Packing, 0.025m raschig ring ceramic packing with varying operating temperature.
operating variable
varied
Design Parameters
Temp (0C)
Cross-sectional Area (
m2)
Column Diameter
(m)
Packing Height
(m)
Surface Area
(m2)
Volume of Packing
(m3)
Tower Height
(m)
0
0.4251626
0.7357062
6.009029
28.52712
2.554814
11.97306
7
0.4590614
0.7644733
4.777753
25.60711
2.193282
10.27862
10
0.4887733
0.7888249
4.305094
24.87447
2.104215
9.641733
15
0.5102593
0.8059765
3.841116
23.83638
1.959965
9.009659
20
0.5523989
0.838597
3.430869
23.41844
1.895208
8.468586
30
0.6209431
0.8891045
2.743771
22.35612
1.703726
7.558167
Table 7: Output from the program using operating pressure of 760 mmHg, operating temperature of 300C, gas flow rate of 0.126kg/s, flooding velocity of 50%, pressure drop of 21 mm H2O/m of Packing, with varying packing type and size.
Operating variable varied
Design Parameters
Packing Type
Packing
Size (m)
Cross-sectional
Area ( m2)
Column
Diameter (m)
Packing
Height (m)
Surface Area
(m2)
Volume of
Packing (m3)
Tower Height
(m)
Rachig Ring Ceramic
0.013
1.241886
1.257384
2.450342
32.20492
3.043046
7.52301
0.025
0.6209431
0.8891045
2.743771
22.35612
1.703726
7.558167
0.038
0.4771479
0.7793875
3.59763
22.11629
1.716601
8.641657
Intallox saddle Plastic
0.016
0.4847827
0.7855982
2.68203
19.15181
1.300202
7.366153
0.025
0.3533431
0.6706952
3.549105
18.54067
1.254051
8.462855
0.038
0.3089896
0.6271895
4.585599
20.06725
1.416902
9.869572
Intallox Saddle Ceramic
0.013
0.6962162
0.9414537
2.709471
23.76575
1.886378
7.563542
0.025
0.4693888
0.7730246
2.786514
19.15414
1.307959
7.499605
0.038
0.3533431
0.6706952
3.833309
19.37914
1.354473
8.860742
Table 4: Output from the program using operating pressure of 760 mmHg, gas flow rate of 0.126kg/s, flooding velocity of 50%, operating temperature of 300C, 0.025m raschig ring ceramic packing with varying pressure drop.
operating variable varied
Design Parameters
Pressure Drop (mm H2O/m of Packing)
Cross-sectional
Area (m2)
Column
Diameter (m)
Packing
Height (m)
Surface Area
(m2)
Volume of
Packing (m3)
Tower Height
(m)
4
0.8781461
1.057329
2.577494
26.66218
2.263416
7.496967
8
0.7271741
0.9621574
2.665361
24.19683
1.938181
7.522906
21
0.6209431
0.8891045
2.743771
22.35612
1.703726
7.558167
42
0.5420035
0.8306689
2.815053
20.91543
1.525769
7.598356
83
0.5141897
0.8090746
2.843654
20.39005
1.462178
7.616372
125
0.4809804
0.7825113
2.880718
19.74892
1.385569
7.641166
Table 5: Output from the program using operating pressure of 760 mmHg, gas flow rate of 0.126kg/s, pressure drop of 21 mm H2O/m of Packing, operating temperature of 300C, 0.025m raschig ring ceramic packing with varying flooding velocity.
operating variable varied
Design Parameters
Flooding velocity (%)
Cross-sectional Area (
m2)
Column Diameter
(m)
Packing Height
(m)
Surface Area
(m2)
Volume of Packing
(m3)
Tower Height
(m)
0.5
0.6209431
0.8891045
2.743771
22.35612
1.703726
7.558167
0.6
0.5174525
0.8116376
3.007907
21.051
1.556449
7.84894
0.65
0.4776486
0.7797962
3.148938
20.59033
1.504086
8.013906
0.7
0.4435308
0.7514305
3.297352
20.2301
1.462477
8.192751
Table 6: Output from the program using operating pressure of 760 mmHg, operating temperature of 300C, flooding velocity of 50%, pressure drop of 21 mm H2O/m of Packing, 0.025m raschig ring ceramic packing with varying gas flow rate.
operating variable
varied
Design Parameters
Gas Flow Rate (Kg/s)
Cross-sectional Area (m2)
Column Diameter (m)
Packing Height (m)
Surface Area (m2)
Volume of Packing (m3)
Tower Height (m)
0.126
0.6209431
0.8891045
2.743771
22.35612
1.703726
7.558167
0.252
1.241886
1.257384
2.743771
33.82787
3.407451
7.933811
0.378
1.862829
1.539974
2.743771
43.50887
5.111176
8.222054
0.504
2.483772
1.778209
2.743771
52.26292
6.814903
8.465053
-
Discussion
Table 2 shows that the correlation coefficient between the results obtained from manual calculations and the CAD program is 1.000. This implies that that there is perfect agreement between the two results, which confirms that the programming of the tables, charts, graphs and correlations using appropriate numerical methods and software are accurate. Thus the tedious calculations, iterations, reading of graphs and tables are now eliminated so that quicker and more accurate results can be obtained (Peters and Timmerhaus, 1991).
Table 3 shows the effect of operating temperature on the design parameters. Comparison of the values show that increase in the operating temperature increase the column diameter and cross-sectional area while tower height, height of packing, volume of packing, and surface area decrease . This could be due to the effect of temperature on the physical properties of the solute gas and solvent such as solubility of the solute gas in the solvent, diffusivity of the solute in both phases, density, viscosity and surface tension. For instance, the higher the gas temperature, the lower the absorption rate and vice-versa (http://www.pdnengineers.com Retrieved February, 2011). This leads to higher solvent requirement. Column diameter and cross-sectional area are directly proportional to solvent flow rate. Excessively high gas temperature can also lead to significant solvent loss through evaporation (S Raymond Woll, personal communication June 25, 1992). The density of the solvent (water) is inversely proportional to temperature and the height of transfer unit is directly proportional to liquid density (Onifade, 2000). That is, increase in temperature decreases the height of transfer unit
and consequently decreases the tower height, height of packing, volume of packing, and surface area.
Table 4 shows the effect of packing type and size on the design parameters. The size of packing used influences the height and diameter of the column, and the pressure drop. Increase in packing size decreases the column diameter and increase tower height. This expected because as the packing size increases, the gas flow rate per unit area decreases. The column diameter is proportional to gas flow rate. Generally, as the packing size is increased, the pressure drop per unit height of packing is reduced and the mass transfer efficiency is reduced. Reduced mass transfer efficiency results in a taller column being needed (Coulson and Richardson, 2004). Normally, in a column in which the packing is randomly arranged, the packing size should not exceed one-eight of the column diameter (Treybal, 1981). This is because the packing density, that is, the number of packing pieces per unit volume, is ordinarily less in the immediate vicinity of the tower walls, and this leads to a tendency of the liquid to segregate toward the walls and the gas to flow in the centre of the tower (Treybal, 1981).This leads to poor liquid distribution and hence reduced mass transfer efficiency. Above this size, this tendency is much more pronounced, that is, liquid distribution and hence the mass transfer efficiency, decreases rapidly. It is recommended that, if possible, the ratio dp/Dc equals 1:15 (Treybal, 1981). Metal packing materials cannot be used for this system because it involves highly corrosive solute (SO2) (Coker, 1991).
Table 5 shows that increase in pressure drop increased the tower height and height of packing and decrease volume of packing, surface area, column diameter and cross-sectional
area. This is attributed to the effect of the properties of the packing materials, such as surface area and free volume in the column. A high pressure drop results in high fan power to drive the gas through the packed column, and consequently high costs. Normally, the column will be designed to operate at the highest economical pressure drop, to ensure good liquid and gas distribution (Coulson and Richardson, 2004). Recommended design values for absorbers and strippers is 15-50 mmH2O/m packing (Coulson and Richardson, 2004). This is because it is advantageous to have a reasonable hold-up in the column as this promotes interphase contact (Coulson and Richardson, 2009).
Table 6 shows the effects of percentage flooding velocity on the design parameters. Increase in percentage flooding velocity decreases the column diameter, cross-sectional area, volume of packing, and surface area while tower height and height of packing increase. The results obtained agreed with the theory that higher flooding velocity leads to more efficient separation (Treybal, 1981), interpreted in terms of size of the column.
Table 7 shows that when the gas flow rate is increased, the packing height does not change. This is due to the fact that the height of gas transfer unit, HG, does not vary with gas
REFERENCES
-
Air-Pollution Control: Packed Columns http://www.pdnengineers.com (Retrieved February, 2011)
-
Brunazzi E. et al., (2002), An Economical Criterion for Packed Absorption Column Design. Chem. Biochem. Eng. Q. 15 (4) 199206.
-
Coker, A. K., (1991) Understanding the Basics of Packed Column Design, Chemical Engineering Progress. 93 – 99.
-
Coulson, J. M and Richardson, J. F., (2004), Chemical Engineering Design,
-
Chemical Engineering, (Third Edition) Butterworth- Heinemann Company,
-
Coulson, J. M. and Richardson, J. F., (2009) Particle Technology and Separation Processes Chemical Engineering (Fifth Edition)Butterworth-Heinemann Company, Woburn, MA, Vol. 2, 212-231.
-
Letter from S. Raymond Woll of Air Products, Inc., to William M. Vatavuk, U.S Environmental Protection Agency, June 25, 1992.
flow rate (except at very low gas flow rate, where HG approaches zero as the gas rate approaches zero). The cross sectional area of the packed column, column diameter, surface area of the packed column and column (tower) height increase as the gas rate increased. This is expected because the cross sectional area of the packed column and column diameter are proportional to gas flow rate (Treybal, 1981). The surface area of the packed column, and column (tower) height, were similarly affected.
4.0 CONCLUSION
A CAD module was developed for implementing the design of a packed absorption column. The program was tested with a design problem by supplying specifications such as operating conditions (pressure, temperature), physical properties (density, viscosity, surface tension), the solute to be absorbed, the solvent selected, gas and solvent mole fractions, percentage flooding velocity, pressure drop, gas flow rate ,packing type and size and the results of the manual calculations and CAD program agree reasonably well with a correlation coefficient of 1.000, which is a very good validation of the module. The designer can vary the above specifications to obtain the best design output within the shortest possible time.
-
McCabe, W. L., Smith, J. C and Harriott, P, (1993). Unit Operations of Chemical
-
Engineering, 5th Edition, McGraw-Hill Book Company, New York, 686-721.
-
Mclnnes, R., Jameson, and Austin, D., (1990), Scrubbing Toxic Inorganics Chemical Engineering, 116-121.
-
Oguntoyinbo, S., (1993), Computer Aided Design and Its Application, NITEL R and D Journal. 1(2), 41-42.
-
Onifade, K. R., (2000), Computer Aided Design for Multi-
Component Distillation
[14] Column. A.U.J. T. 4(1), 26-38.-
Perry, R. H., and Chilton, C. H., (1997), Chemical Engineers Handbook, 7th Edition, McGraw-Hill Book Company, New York.
-
Peters, M. S., and Timmerhaus, K. D., (1991), Plant Design and Economics for Chemical Engineers, Fourth Edition, McGraw-Hill Book Company, New York, 625-939.
-
Treybal, R. E., (1981) Mass Transfer Operations, Third Edition McGraw-Hill Book Company, New York, 275-289.