Performance Evaluation of UFAPB Reactor for Treatment of Domestic Sewage

DOI : 10.17577/IJERTV4IS100212

Download Full-Text PDF Cite this Publication

Text Only Version

Performance Evaluation of UFAPB Reactor for Treatment of Domestic Sewage

T. Shubaashini

Assisstant Professor, Department of Civil Engineering,

KPR Institute of Engineering and Technology , Coimbatore 07

  1. RajKumar

    Assisstant Professor, Department of Civil Engineering, PSG College of Technology, Coimbatore-04

    Abstract: The study was related to the possibility of using UFAPB reactor applied to the treatment of domestic sewage. The effect of Hydraulic Retention Time (HRT) ranging from 12 to 90 hrs and different Organic Loading Rate (OLR) on the performance of the reactor were made. The reactor had an internal diameter of 120mm & height of 600mm resulting in total volume of 6.780 litres & bed volume of 5.99 litres. Gas collecting tank was separately designed with 250mm height & 80mm diameter. The packing media used in the study were coarse aggregate passing through 12.5mm and retaining on 10 mm sieve. Domestic sewage generated from PSG IMS Coimbatore, Tamil Nadu was used as the substrate. The inoculum was prepared using horse dung. To begin with, the reactor was seeded with the inoculums a mixture of horse dung slurry at 24 hrs HRT & left for different HRT. The experiments were performed at HRT of 12, 16, 24, 36, 48, 54,

    62, 70, 84 & 90 hrs based on empty reactor volume & the performance of the reactor was evaluated based on the removal of organic matter. The COD & BOD removal efficiency for domestic sewage were in the range of 96.6% to 77.33% & 94.32% to 71.01% respectively. The pH was maintained in the range of 7 to 8.5. The total, volatile, dissolved, suspended & fixed solids removal efficiency were 83.40%, 97.70%, 88.51%, 93.49% & 90.28% respectively, and methane gas emission was also achieved.

    1. INTRODUCTION

      The term wastewater is commonly used to describe liquid wastes that are collected and transported to a treatment facility through a system of sewers. Wastewater is generally divided into two broad classifications: domestic wastewater and industrial wastewater. Domestic wastewater comes from communities of homes, businesses, and institutions.

      Domestic wastewater is 99.9% water and only 0.1% solids. Most modern wastewater treatment facilities are designed to treat domestic wastewater. Industrial wastewaters that contain high strength waste, toxic waste or acid/caustic waste may have to be pretreated to make them safe to discharge to the collection system. If not, the processes at the wastewater treatment plant receiving the waste could be disrupted. Storm wastewater should be collected and treated (when necessary) separately from domestic and industrial wastewater.

        1. Domestic waste water

          Domestic sewage carries used water from houses

          and apartments; it is also called sanitary sewage. Many of our daily chores such as bathing, doing laundry, flushing toilets, preparing meals, washing dishes and other activities generate wastewater.

        2. Background of Anaerobic Treatment System

          With the growing population and increasing levels of urbanization and industrialization, the water is becoming a scarce resource and also getting polluted at a very rapid rate. To overcome these, the wastewaters shall be treated properly and maximum reuse/recycling shall be practiced.

          These wastewaters can be either treated with aerobic process or anaerobic systems. In the past, aerobic treatment system was favoured as it was considered to be reliable, stable and efficient. However, aerobic treatment systems require large amounts of power for aeration and mixing, whereas power requirement for anaerobic process is relatively low.

          Anaerobic digestion is a complex, natural, multistage process. It is an engineered methanogenic process in which decomposition of organic matter under oxygen-free conditions and involves a mixed consortium of different species of anaerobic microorganisms that transform organic matter into biogas. The process is also called biomethanation.

          With respect to sustainability and cost effectiveness, anaerobic treatment has a much better score than many alternatives. Particularly, the energy conservation aspect, i.e, avoiding the loss of energy for destruction of organic matter, while energy is reclaimed from the organic waste constituents in the form of biogas, was an important driving force in the development of such systems. At present, other advantages such as the extremely low production of excess sludge and the system compactness are important selection criteria.

    2. OBJECTIVES OF THE STUDY

          1. Pilot scale study of Upflow Anaerobic Packed Bed reactor (UFAPBR) on treating domestic sewage by using various control factors.

          2. To study the performance evaluation of the UFAPBR for large scale applications.

          3. To feed the reactor with various loading rates & to determine the efficiency of the reactor & methane gas emission.

          4. To determine the stability of the process at short & high HRTs and to examine its treatment efficiencies.

    3. MATERIALS & METHODS

        1. Experimental set up of UFAPBR

          Laboratory scale continuous Upflow Anaerobic Packed Bed reactor made of PVC pipe was used in the present study. The reactor had an internal diameter of 120mm and height of 600mm resulting in total volume of

          6.78 liter and bed volume of 5.99 liter. The top of the reactor is tightly closed to maintain the stringent anaerobic condition. A gas head space of 100mm was provided on the top of the reactor.

        2. Components of UFAPB Reactor

          1. Feed tank

          2. Feed distribution system

          3. Packing media

          4. Gas collector

          5. Sampling ports

        3. Feed inlet and outlet arrangements

          The reactor was fed with substrate from the feed tank to the inlet pipe provided at the bottom of the reactor. The diameter of the feed inlet pipe is 6mm provided upside down. The effluent pipe of diameter 5mm is provided along the side of the UFAPBR reactor about 10mm from the top of the reactor. Constant flow rate in the range of 4 ml/min to12 ml/min were maintained with two adjustable stop rings.

        4. Sampling ports

          Five sampling ports were installed in the UFAPB reactor for the purpose of

          1. Feed distribution

          2. Effluent collection

          3. Gas collection

            Three sampling ports were installed along the length of the UAPBR at 15 cm intervals, starting from a height of 10 cm above the reactor bottom. The sampling ports of 6mm internal diameter were made of brass nipples was used. The sampling ports were sealed into the wall of the reactor with rubber cork to give tightness. In UFAPBR reactor out of three sampling ports one was below the packing media, one was at packing media and the other above the media fill. This was required to ascertain the role of packing material on reactor performance.

        5. Support material

          The purpose of packing medium is to retain solids inside the reactor, either by the bio-film formed on the surface of the packing medium or by the retention of solids in the interstices of the medium or below it.

          The packing media used in the study were aggregate media of round shape which can retain more biomass on surfaces rather than plain surfaces. The packing media have been designed to occupy from the total depth of the UFAPB reactor to approximately 80% of the height of the reactor.

        6. Substrate

          Domestic sewage generated from PSG Institute Of Medcal Science Coimbatore, Tamil Nadu was used as the substrate.

        7. Seeding

          Effective microorganisms were used as seed and the reactor was seeded anaerobically with horse dung.

        8. Biogas outlet

      The biogas outlet was provided at the top of the reactor. A gas headspace of 15 cm was maintained. Biogas produced from the reactor will be collected in a gas collection unit.

    4. RESULTS AND DISCUSSION

    1. COD removal efficiency

      Normally the COD of domestic sewage ranges between 200 to 700 mg/lt. The COD value is getting decreased for all the HRTS and those values are compared. The comparison chart shows that the COD removal efficiency is more at maximum HRTs and minimum removal efficiency for lower HRTs. Maximum COD removal efficiency of 96.6% was achieved for HRT of 84 hrs. The removal efficiency for 12 HRT is about 77.33 % due to the loss of biomass during wash out had reduced the COD removal efficiency which is tabulated (Table1).

    2. BOD removal efficiency

      Normally the BOD value of domestic sewage ranges between 100 to 400 mg/lt. The maximum BOD removal efficiency of 91.6 % was achieved at 36HRT which is tabulated (Table 2).

    3. pH

      The pH is a very important variable in the UFAPB reactor process. When the pH in the reactor is too low (<6), the consumption of fatty acids gets strongly inhibited. If the pH is too high (>8.5), the bacteria are limited in their growth by the low concentrations of unionized fatty acids. The pH determines the growth of both methanogens and acidogens. So, the pH of the influent in the inlet was maintained between 7 and 8. The comparison is made between various HRTs pH value. The graph shows only the variation in the pH value among various HRTs. Like other parameters, the pH is not reduced which is tabulated (Table 3 & 4).

    4. Total Solids

Total solids is a measure of all the suspended, volatile, fixed, and dissolved solids in a sample of waste water. In this study the total solids level was obtained within the limit which is tabulated (Table 5).

Table 1: COD removal efficiency for various HRTs.

HRT(h

rs)

Influent (mg/lt)

Effluent (mg/lt)

Removal efficiency

12

3005

681

77.33

16

3005

579

80.73

24

3005

464

84.56

36

3005

397

86.79

48

3005

355

88.19

54

3005

288

90.41

62

3005

243

91.91

70

3005

198

93.41

84

3005

102

96.6

90

3005

299

90.05

Table 2: BOD removal efficiency for various HRTs.

HRT(h

rs)

Influent

(mg/lt)

Effluent

(mg/lt)

Removal

efficiency

12

1725

500

71.01

16

1725

366

78.78

24

1725

299

82.67

36

1725

267

84.52

48

1725

232

86.55

54

1725

189

89.04

62

1725

137

92.06

70

1725

109

93.68

84

1725

98

94.32

90

1725

156

90.96

Table 3: pH for short HRTs

Days

12 hrs

16 hrs

24 hrs

36 hrs

48 hrs

1

8.48

8.43

8.41

8.30

8.30

3

8.47

8.40

8.40

8.29

8.27

5

8.43

8.37

8.38

8.26

8.24

7

8.38

8.34

8.32

8.24

8.22

9

8.33

8.31

8.30

8.21

8.20

11

8.29

8.29

8.27

8.18

8.18

13

8.28

8.25

8.25

8.15

8.15

15

8.22

8.30

8.30

8.12

8.07

17

8.32

8.15

8.22

8.09

8.02

19

8.19

8.11

8.17

8.07

7.99

21

8.10

8.07

8.06

7.95

7.93

23

8.01

7.93

7.90

8.08

8.10

Table 4: pH for high HRTs

Days

54

hrs

62

hrs

70

hrs

84

hrs

90

hrs

1

8.20

8.20

8.19

8.00

8.60

3

8.19

8.17

8.11

7.94

8.58

5

8.15

8.13

8.07

7.88

8.41

7

8.10

8.11

8.03

7.76

8.38

9

8.08

8.06

8.00

7.60

8.25

11

8.05

8.01

7.95

7.51

8.12

13

8.01

7.84

7.87

7.44

8.10

15

7.99

7.66

7.77

7.38

7.96

17

7.93

8.00

7.60

7.22

7.85

19

8.11

7.52

8.10

7.16

7.57

21

7.77

7.31

7.44

7.11

7.34

23

7.69

7.11

7.23

7.02

7.12

Table 5: TS, DS, SS, VS & FS values for various HRTs

FS

(mg/ lt)

HRT

(hrs)

Influe nt (mg/lt

)

TS

(mg/ lt)

DS

(mg/ lt)

SS

(mg/ lt)

VS

(mg/ lt)

12

2995

989

696

294

207

496

16

2995

933

656

288

198

483

24

2995

861

599

279

179

468

36

2995

778

557

267

147

444

48

2995

699

511

258

118

406

54

2995

655

478

241

103

397

62

2995

536

425

222

89

375

70

2995

512

388

210

77

333

84

2995

497

344

195

69

291

90

2995

555

378

223

90

334

CONCLUSIONS

The result obtained from the present laboratory study reveals that the application of UFAPB reactor of can successfully treat domestic wastewater at mesophilic temperature. From the performance evaluation of UFAPB reactor the following conclusions were drawn:

  1. A start-up period of 45 days was required to achieve the steady-state phase with an HRT of 84hrs. The results shows that by increasing the HRTs, the treatment of domestic effluent was more effective with gradual increased in COD, BOD & total solids removal efficiency.

  2. At 84 hr HRT, the COD, BOD removal efficiency of

    96.6 % and 94.32 %, was obtained respectively. At 84 hr HRT, the TS, SS, DS, FS &VS removal efficiency of 76.03%, 91.63%, 82.73%, 86.30% & 95.59% was obtained respectively.

  3. Since there is a decrease in removal efficiency after 84hrs i.e. 90hrs, it may be conclude that maximum HRT(84 hrs) is the optimum for the bioreactor .

  4. It is evident that the UFAPB reactor can be effectively used for the treatment of domestic wastewater & production of methane gas in developing countries like India, since the system can be designed with relatively high HRT.

SCOPE OF THE PROJECT

  1. The study can be performed on the Biogas production for varied HRT and Biogas

    composition.

  2. Microbial population can be identified in the reactor using Scanning Electron Microscope (SEM).

  3. Kinetic constants studies can be performed using mathematic modelling.

  4. Two stage anaerobic treatment of domestic wastewater using Hybrid Up flow Anaerobic Filter can be studied using other different packing media.

  5. Varying the material, size, shape and surface area of the packing media the study can be performed.

  6. Anaerobic process could also be followed by aerobic processes for effluent polishing to utilize the benefits of both processes.

ACKNOWLEDGEMENT

The authors wish to thank Dr. R. Rudramoorthy, the Principal, Dr.

G. Sankarasubramanian, the Head of the Department of Civil Engineering, PSG College of Technology for providing the necessary facilities and guidance to complete the work successfully.

REFERENCES

  1. Demirel, B. et al, Anaerobic Treatment of Dairy Wastewaters: A review, Process Biochemistry Elsevier, 40 : 25832595, (2005).

  2. Najafpour, G.D. et al, Biological Treatment of DairyWastewater in an Upflow Anaerobic Sludge-Fixed FilmBioreactor, American-Eurasian Journal of. Agri & Env. Sci.,4 (2): 251-257, (2008).

  3. Omil F., et al, Anaerobic Filter Reactor Performance for the Treatment of Complex Dairy Wastewater at Industrial Scale, Water Research, 37: 4099-4108, (2003).

  4. Treatment of domestic wastewater in an upflow anaerobic packed bed reactor -Er. Kiran D. Bhuyar

  5. High strength sewage treatment in a UASB reactor and an integrated UASB-digester system -Nidal Mahmoud, Dept of Env. & water Studies, Birzeit University

  6. American Public Health Association (APHA), American Water Works Association (AWWA), and Water Pollution Control Federation(WPCF). (1992). Standard methods for examination of water andwastewater, 16th Ed., Washington, D.C.