Time of the Day based Demand Side Management for Cost Optimization

DOI : 10.17577/IJERTV4IS120133

Download Full-Text PDF Cite this Publication

Text Only Version

Time of the Day based Demand Side Management for Cost Optimization

Ajan. A

Asst. Professor

Electrical and Electronics Department College of Engineering Kidangoor Kottayam, India

A. Maintaining the Integrity of the Specifications

The template is used to format your paper and style the text. All margins, column widths, line spaces, and text fonts are prescribed; please do not alter them. You may note peculiarities. For example, the head margin in this template measures proportionately more than is customary. This measurement and others are deliberate, using specifications that anticipate your paper as one part of the entire proceedings, and not as an independent document. Please do not revise any of the current designations.

III. PREPARE YOUR PAPER BEFORE STYLING Before you begin to format your paper, first write and save

the content as a separate text file. Keep your text and graphic files separate until after the text has been formatted and styled. Do not use hard tabs, and limit use of hard returns to only one return at the end of a paragraph. Do not add any kind of pagination anywhere in the paper. Do not number text heads- the template will do that for you.

Finally, complete content and organizational editing before formatting. Please take note of the following items when proofreading spelling and grammar:

A. Abbreviations and Acronyms

Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.

B. Units

Use either SI (MKS) or CGS as primary units. (SI units are encouraged.) English units may be used as secondary units (in parentheses). An exception would

Abstract The need for electrical energy is peaking. As the resources are limited the effective utilization of the energy is essential. Demand side management plays a vital role in this context. It is the modification of energy demand by the consumer either by financial incentives or by education. Many of the countries successfully tried time of the day pricing method for implementing demand side management. This paper mainly focusing on the development of an algorithm which will help to optimize the cost where the time of the day based demand side managemt is used.

KeywordsOptimization; Demand Side Management; Time of the Day Tariff;

Jibin Joseph

Asst. Professor

Electrical and Electronics Department College of Engineering Kidangoor Kottayam, India

  1. LOAD DETAILS OF A TYPICAL 3 BHK FLAT For the analysis, the load details of a typical 3 BHK flat is

    considered and the cost of energy over one month period is calculated.

    Time slots

    Components

    Units

    Consumed

    12AM-1AM

    3 AC

    3.5

    1AM-2AM

    3 AC

    3.5

    2AM-3AM

    3 AC

    3.5

    3AM-4AM

    3 AC

    3.5

    4AM-5AM

    3 AC

    3.5

    5AM-6AM

    2 AC, 2Tubes, Heater, 1Fan

    3.66

    6AM-7AM

    2Fan, Induction cooker, 1Tube, 1Mixer,

    Microwave, Water Pump, Heater,

    6.696

    7AM-8AM

    TV, 2 Heaters, Iron box

    4.15

    8AM-9AM

    Fridge

    0.5

    9AM-10AM

    Fridge

    0.5

    10AM-11AM

    Fridge

    0.5

    11AM-12PM

    Washing machine, Vacuum cleaner, Induction

    cooker, Mixer, 1Fan

    4.53

    12PM-1PM

    1Fan, TV,

    0.73

    1PM-2PM

    1Fan, TV

    0.73

    2PM-3PM

    1AC

    1.5

    3PM-4PM

    1AC

    1.5

    4PM-5PM

    Dishwasher, Water pump,

    2.746

    5PM-6PM

    TV, Music system, Computer, 2 Fans,

    2.11

    6PM-7PM

    6Tubes,2 CFL, TV, Computer, Music system,

    Mixer, Grinder

    3.599

    7PM-8PM

    6Tubes, 2CFL, Induction cooker, TV,

    Computer, 2Fans

    3.434

    8PM-9PM

    4Tubes, 2CFL, 1Fan, TV

    0.974

    9PM-10PM

    Dishwasher, 2CFL,2 Tubes, Computer, TV

    4.464

    10PM-11PM

    Table lamp, Computer, 2AC, 1Fan

    2.92

    11PM-12PM

    3 AC,

    3.5

    Total units consumed in one month

    1987.29

    Total cost in one month

    11282 Rs

    TABLE I. LOAD DETAILS AND COST CALCULATION

    1. INTRODUCTION

The traditional model of our power system is unidirectional. The advancement in the communication and control systems enables us to control the loads with greater degree of flexibility. The demand for electricity is increasing day by day. Even if we forget the constraints in the generation the next important thing is the grid capacity. In near future the grids might soon face their maximum limit. No solutions for this condition until and unless we further enhance the capacity of the grid. But in another way we can delay it by using intelligent demand side management techniques [1]. Demand Side Management is the process of intentionally modifying the demand from the user side by providing financial incentives or education [2]. Previously it was utility driven, it might become partially a customer driven in the near future.

There are different types of DSM techniques being used. One is Direct Load Control (DLC). It is the method in which loads are directly shed by the utility, based on an agreement with the user [3]. Another method is known as smart pricing where the user is voluntarily manage his load in order to reduce their consumption during peak times [4]. In this regard various types of pricing are available such as Critical peak pricing (CPP), Time Of the Day pricing (TOD), Real Time Pricing( RTP) etc. In the Time of the Day pricing method the consumers have to pay more for energy during peak hours and comparatively less in off peak hours. Considerable amount of savings can be made in such a system if the loads are shifted in a specific manner. This paper mainly focusing on developing an algorighm which will felicitate the shifting of loads with minimum level of inconvenience and there by optimizing the cost. The whole paper will be divided in to three parts. II section will be containing the load details and load curves of a typical 3 BHK flat. The III section the development of the algorithm is discussed and the last section will be containing the conclusions and the future scopes of this study.

Table II shows the rate schedule used for the energy cost calculation.

TABLE II. RATE SCHEDULE

Fixed charges

per month

For the 1st KW

Rs 25/-per KW

For te additional KW

Rs 35/-per KW

Energy charges per month

0-30 Units

250 ps/unit

31-100 Units

370 ps/unit

101-200Units

485 ps/unit

Above 200 units

585 ps/unit

C. Equations

The equations are an exception to the prescribed specifications of this template. You will need to determine whether or not your equation should be typed using either the Times New Roman or the Symbol font (please no other font). To create multileveled equations, it may be necessary to treat the equation as a graphic and insert it into the text after your paper is styled.

Fig. 1 shows the daily load curve of the flat.

Load in Watts

Time

Fig. 1. Load curve of a 3 BHK flat

For the developemnt of the algorithm few assumptions are taken. The over all time frame will be either lies in peak period or off peak period.And the energy prices in the peak time is assumed to be 3 times that during the off peak time. Fig. 2 shows the cost curve based on the TOD pricing.

Cost in Rs

Time

Fig. 2. Cost curve based on the TOD tariff

III .ALGORITHM

From the load curves and cost curves it is obvious that during peak hours the customer have to pay more money rather than during the off peak hours. A few constraints have to be keep in mind before the scheduling of the loads. The scheduling should results minimum possible inconvenience to the customer. And if two possible time slots are found feasible importance should be given to the first time slot.

Fig. 3 shows the time during which energy cost will be more where the load scheduling algorithm can be used.

Fig. 3. Figure showing the time slots in which the loads have to be

rescheduled

For the scheduling of the loads the following steps are used

Step 1. Figure out the shiftable loads (non critical loads)

Step 2.Specify the earlier start time and late start time of the equipments

Step 3: Check whether the loads can be shifted

Step 4: Shift the loads if possible and calculate the savings Keep in mind all loads are not readily shiftable. Consider

the case of a lighting load and a geyser. Comparing with a geyser lighting load is not readily shift able. During off peak period the water can be heated. But the lighting loads have to be kept on as long as there is lack of light experienced. The earlier start time and the late start time specify the time span in which the load can be re-distributed. To find out the rescheduling of the load is possible or not the following steps can be adopted.

Step 1: Calculate the energy cost per hour based on flat rate tariff and TOD tariff

Step 2: Compare both, if TOD tariff is higher than that of flat rate tariff consider the earlier start time and late start time of the equipment

Step 3: Calculate the time slot for rescheduling using the following equation

Scheduled time=( LST- EST)- ( Peak price period)

where LST is late Start Time and EST is Earlier Start Time.

Fig. 4. Flow Chart for the given algorithm

IV .CONCLUSION

A novel method for the time of the day based demand side management is developed. By considering the smaller time spans and by prioritizing the loads a more convenient load scheduling can be achieved.

REFERENCES

  1. Palensky, P.; Dietrich, D., "Demand Side Management: Demand Response, Intelligent Energy Systems, and Smart Loads," in Industrial Informatics, IEEE Transactions on , vol.7, no.3, pp.381-388, Aug. 2011

  2. G. M. Masters, Renewable and Efficient Electric Power Systems, NJ:Wiley,2004.

  3. N. Ruiz, I. Cobelo, and J. Oyarzabal, A direct load control model for virtual power plant management, IEEE Trans. Power Syst., vol. 24, no. 2, pp. 959966, May 2009

  4. K. Herter, Residential implementation of critical-peak pricing of electricity,Energy Policy, vol. 35, pp. 21212130, Apr. 2007.