Experimental Study on Behavior of Fiber Reinforced Concrete using Polyester and Glass Fibers

DOI : 10.17577/IJERTV5IS110306

Download Full-Text PDF Cite this Publication

Text Only Version

Experimental Study on Behavior of Fiber Reinforced Concrete using Polyester and Glass Fibers

Prof. S.Anandaraj1,, Prof.K.Letcham2,

1,2 Assistant Professor, Department of Civil Engineering,

KPR Institute of Engineering and Technology, Coimbatore, Tamilnadu, India.

Dr. Jessy Rooby4

4Professor,

Dr. P.Vincent@Venkatesan3

3 Senior Professor, Department of Civil Engineering,

Mepco Schlenk Engineering College, Sivakasi, Tamilnadu, India.

Department of Civil Engineering, Hindustan University,

Chennai, PIN 603 103, Tamilnadu, India

Abstract – Normally Concrete is firm in compression but anemic in tension and shear. To eliminate those problems the introduction of fibers was brought in as an alternative and also to improve the ductile property of concrete. The purpose of this study is to find the behavior of concrete reinforced with hybrid macro fibers. By adding macro fibers in the concrete, cracks during plastic and hardening stage are reduced. By adding the macro fibers, tensile strength and small amount of compressive strength are increased. In this study, four batches of concrete were cast. Basic one is controlled concrete (without fibers) and the remaining three with different volume fractions of 0.5%, 1%, and 1.5% .The above volume fractions are further divided in to combination of two different fibers of polyester and Glass of combination 25:75, 50:50, 75:25 respectively for polyester and Glass fibers. Concrete specimens (cubes, cylinders and prisms) were cast, cured and tested. The various parameters such as compression, Split tensile and flexural strength are determined. From the above results it is concluded that the optimum combination of volume fraction is 25:75 of polyester and glass fiber respectively.

Key Words: Microfiber reinforced concrete, polyester fiber, glass fiber, flexural strength, compressive strength, split tensile strength.

  1. INTRODUCTION

    Concrete based materials have been implemented in structural members since prehistoric times. Day by day the importance of concrete has developed and the limitations of concrete have been slowly but surely eliminated which increases the life of concrete allowing a higher achievement. However, concrete is firm in compression but anemic in tension. To overcome this failing in concrete, steel reinforcement is utilized to carry the tensile forces and prevent any cracking the concrete so that it remnant largely in compression under load. [1]

    Glass Fibre reinforced concrete (GFRC) is defined as concrete made with cement containing Fine and coarse aggregate and discrete fiber. The initiation of Glass fibers

    was an alternative to developing concrete in view of improving its tensile and flexural strengths. GFRC is being increasingly used to improve tensile strength, energy absorbing capacity and better fatigue strength. Generally, for structural applications, Glass fibers plays an major role supplementary to reinforcing bars. Glass fibers can arrest cracking and improve tensile strength as a result of fatigue, impact, and shrinkage, or thermal stresses. With the advancement of synthetic fiber, macro-fibers (fibers diameter is larger than 0.1mm is defined as macro- fiber [5]) have been used generally in civil engineering. Due to some limitations of steel fiber, macro synthetic fiber could be a better solution for augment performance, such as- ease light weight concrete structure, high corrosion resistance; better enduring (post-cracking) flexural strength, smaller crack width and improved performance in impact, abrasion along with more of a leveled surface than classic steel fiber reinforced concrete [1]. Synthetic macro fibers are a new type reinforcement material in reinforced concrete.

    In this study, mechanical behavior of concrete reinforced with three different percentages with different combinations of polyester and glass, where plain concrete as a control specimen was investigated. In this investigation, several laboratory works were performed for instance, casting and testing of cubes for compression and tension, Beams for shear and prisms for the determination of stress-strain relationships and finally making comparison and discussion on the test results[1]

  2. FIBERS USED IN THIS PROJECT:

    • Polyester fibers

    • Glass fibers.

    1. Glass Fibers:

      In the form first used, glass fibers were found to be alkali reactive and products in which they were used deteriorated rapidly. Alkali-resistant glass containing 16%

      zirconia was successfully formulated in the 1960's and by 1971 was in commercial production in the UK. Other sources of alkali-resistant glass were developed during the 1970's and 1980's in other parts of the world, with higher zirconia contents. Alkali-resistant glass fiber is used in the manufacture of glass-reinforced cement (GRC) products, which have a wide range of applications. Glass fiber is available in continuous or chopped lengths. Fiber lengths of up to 35 mm are used in spray applications and 25-mm lengths are used in premix applications[2].

      Glass fiber has high tensile strength (2 4 GPa) and elastic modulus (70 80 GPa) but has brittle stress-strain characteristics (2,5 4,8% elongation at break) and low creep at room temperature. Claims have been made that up to 5% glass fiber by volume has been used successfully in sand-cement mortar without balling[2].

      Fig 1. Glass fibers

      Glass-fiber products exposed to outdoor environment have shown a loss of strength and ductility. The reasons for this are not clear and it is speculated that alkali attack or fiber embrittlement are possible causes. Because of the lack of data on long-term durability, GRC has been confined to non-structural uses where it has wide applications. It is suitable for use in direct spray techniques and premix processes and has been used as a replacement for asbestos fiber in flat sheet, pipes and a variety of precast products. GRC products are used extensively in agriculture; for architectural cladding and components; and for small containers.

    2. Advantages of Glass Fibers:

      • Post cracking behavior.

      • It increases tensile strength and small amount of compressive strength.

      • It arrests the micro and macro cracks.

    3. Polyester Fibers:

      Polyester fibers are available in monofilament form and belong to the thermoplastic polyester group. They are temperature sensitive and above normal service temperatures their Properties may be altered. Polyester fibers are somewhat hydrophobic. Polyester fibers have been used at low contents (0,1% by volume) to control plastic-shrinkage cracking in concrete.

      Fig 2. Polyester fibers

      There are some important properties of polyester fibers are,

      • The equivalent diameter of polyester fiber is 20m

      • The relative density is 1.34 to 1.39

      • The tensile strength of polyester fibers is 230 to 1100 Mpa

      • The elastic modulus of polyester fibers is 17Gpa

      • The ultimate elongation of polyester fibers is 12 to 150%

      • The ignition temperature of polyester fibers is 600°C

      • The Melt, oxidation or decomposition of polyester fibers is 260°C

    4. Advantages Of Polyester Fibers:

      • Reduces crack during plastic and hardening stage.

      • Reduces water seepages and protects steel in concrete from corroding and walls from dampening.

      • Rebound loss reduced by 50-70%.

      • Time taken for plastering is reduced and work is completed aster.

      • Increases abrasion resistance by over 40% thereby increasing life of concrete surface.

      • Impact strength is increased by 20 to 40%.

      • Reduces the crack width since it act as a bridge.

    5. Applications Of Polyester Fibers:

    • RCC&PCC like lintel, beam, column, flooring and all plastering.

    • Foundation, tanks, manhole cover and tiles.

    • Plastering.

    • Roads and pavements.

    • Hollow blocks and precast.

  3. OBJECTIVES OF THIS WORK:

    • To study the behaviour of concrete by adding 2 different fibres of polyester and Glass of 0.5%, 1.0% & 1.5% with each combination of 25:75, 50:50, 75:75 respectively for polyester and Glass fibres.

    • To determine the behavior such as compressive strength, split tensile strength, flexural strength.

    • To determine the optimum combination of fibers with above %.

    • From the optimum combination, Beams are to be cast with 0.5%, 1% and 1.5% of fibers and to determine the flexural strength.

  4. MIX DESIGN:

S.No

% of fiber added

7days strength (N/mm2)

28days strength (N/mm2)

1

CC

16.85

27.25

2

0.5%

16.52

27.84

3

1.0%

17.03

29.52

4

1.5%

18.14

31.97

S.No

% of fiber added

7days strength (N/mm2)

28days strength (N/mm2)

1

CC

16.85

27.25

2

0.5%

16.52

27.84

3

1.0%

17.03

29.52

4

1.5%

18.14

31.97

Concrete mix has been design based on Indian standard Recommended Guidelines IS: 10262-1982.The proportions and quantities of various materials for the concrete mix have been tabulated below.

35

30

25

20

15

10

35

30

25

20

15

10

Table 1: Proportion of mix design for M25 concrete

Table.3 Compressive Strength Test Results (50% – 50%)

Cement

Fine Aggregate

Coarse Aggregate

Water

By Ratio

1

1.21

2.87

0.45

By weight

425kg/m³

512Kg/m³

1218Kg/m³

191.61Litre

IV. EXPERIMENTAL WORKS:

  1. Compressive Strength Test

    The strength of concrete is controlled by the proportioning of cement, coarse and fine aggregates, Water, and various admixtures. The ratio of the water to cement is the chief factor for determining concrete strength as shown. The lower the water-cement ratio, the higher is the Compressive strength. A certain minimum amount of water is necessary for the proper chemical action in the hardening of concrete; extra water increases the workability (how easily the concrete will flow) but reduces strength. A measure of the workability is obtained by a slump test. Actual strength of concrete in place in the structure is also greatly affected by quality control procedures for placement and inspection. The strength of concrete is denoted in the United States by f' c which is the compressive strength of test cylinder 6 in. in diameter by 12 in. high measured on the 28th day after they are made.

    Table.2 Compressive Strength Test Results (25% – 75%)

    S.No

    % of fiber added

    7days strength (N/mm2)

    28days strength (N/mm2)

    1

    CC

    16.85

    27.25

    2

    0.5%

    17.02

    28.68

    3

    1.0%

    17.98

    31.84

    4

    1.5%

    19.33

    33.16

    5

    0

    5

    0

    Cc

    0.50%

    1.00%

    1.50%

    Cc

    0.50%

    1.00%

    1.50%

    % of polyester & glass fibers

    % of polyester & glass fibers

    Fig 4Variation of compressive strength at various ages Table.4 Compressive Strength Test Results (75% – 25%)

    Fig 4Variation of compressive strength at various ages Table.4 Compressive Strength Test Results (75% – 25%)

    compressive strength in Mpa

    compressive strength in Mpa

    Fig 4 Variation of compressive strength at various ages Table.4 Compressive Strength Test Results

    S.No

    % of fiber added

    7days strength (N/mm2)

    28days strength (N/mm2)

    1

    CC

    16.85

    27.25

    2

    0.5%

    16.92

    27.76

    3

    1.0%

    17.24

    28.91

    4

    1.5%

    17.98

    31.53

    S.No

    % of fiber added

    7days strength (N/mm2)

    28days strength (N/mm2)

    1

    CC

    16.85

    27.25

    2

    0.5%

    16.92

    27.76

    3

    1.0%

    17.24

    28.91

    4

    1.5%

    17.98

    31.53

    (75% – 25%)

    35

    com pressive strength in M pa

    com pressive strength in M pa

    30

    25

    20

    15

    10

    5

    0

    Cc 0.50% 1.00% 1.50%

    % of polyester & glass fibers

    7 days

    28 days

    7 days

    28 days

    7 days

    35

    30

    25

    20

    15

    35

    30

    25

    20

    15

    compressive strength in Mpa

    compressive strength in Mpa

    28 days

    10

    5

    0

    7 Days

    28 days

    10

    5

    0

    7 Days

    28 days

    Conventional 0.50%

    1.00%

    1.50%

    Conventional 0.50%

    1.00%

    1.50%

    % of polyester & glass fibers

    % of polyester & glass fibers

    Fig 3 Variation of compressive strength at various ages

    Fig 4 Variation of compressive strength at various ages

  2. Split Tensile Strength Test

    The split tensile strength of concrete cylinder was determined based on IS: 5816-1999. The load shall be applied nominal rate with in the range 1.2 N/(mm2/min) to

    2.4 N/(mm2/min).

    Table.5. Split tensile strength test results (25% 75%)

    S.No

    % of fiber added

    28days strength (N/mm2)

    1

    CC

    2.16

    2

    0.5%

    2.31

    3

    1.0%

    3.12

    4

    1.5%

    3.77

    4

    sp lit ten s i le s tr en g th in M p a

    sp lit ten s i le s tr en g th in M p a

    3.5

    3

    2.5

    2

    1.5

    1

    0.5

    0

    Cc 0.50% 1.00% 1.50%

    % of polyester & glass fibers

    28 days

  3. Flexural Strength Test

This test method is used to determine the modulus of rupture of specimens prepared and cured. The strength determined will vary where there are differences in specimen size, preparation, moisture condition, or curing. This test method covers determination of the flexural strength of concrete specimens by the use of a simple beam with center-point loading. It is not an alternative to Test Method. The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values

Fig .6 Variation of Split tensile strength at 28days

S.No

% of fiber added

28days strength (N/mm2)

1

CC

2.16

2

0.5%

1.84

3

1.0%

2.68

4

1.5%

3.43

S.No

% of fiber added

28days strength (N/mm2)

1

CC

2.16

2

0.5%

1.84

3

1.0%

2.68

4

1.5%

3.43

Table.6. Split tensile strength test results (50% – 50%)

stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

S.No

% of fiber added

28days strength (N/mm2)

1

CC

4.95

2

0.5%

5.93

3

1.0%

6.78

4

1.5%

7.04

S.No

% of fiber added

28days strength (N/mm2)

1

CC

4.95

2

0.5%

5.93

3

1.0%

6.78

4

1.5%

7.04

Table.8. Flexural strength test results (25% 75%)

4

split tensile strength in Mpa

split tensile strength in Mpa

3.5

3

2.5

2

1.5

1

0.5

0

Cc 0.50% 1.00% 1.50%

% of polyester & glass fibers

8

F l e x u r a l s t r e n g t h i n M p a

F l e x u r a l s t r e n g t h i n M p a

7

6

28 days

5

4

3

2

1

28 days

Fig .7 Variation of Split tensile strength at 28days

Table.7. Split tensile strength test results (75% – 25%)

0

Cc 0.50% 1.00% 1.50%

% of polyester & glass fibers

Fig 9 Variation of Flexural strength at 28days

S.No

% of fiber added

28days strength (N/mm2)

1

CC

2.16

2

0.5%

1.94

3

1.0%

2.38

4

1.5%

3.05

S.No

% of fiber added

28days strength (N/mm2)

1

CC

2.16

2

0.5%

1.94

3

1.0%

2.38

4

1.5%

3.05

Table.9. Flexural strength test results (50% – 50%)

3.5

3

2.5

2

1.5

S.No

% of fiber added

28days strength (N/mm2)

1

CC

4.95

2

0.5%

5.69

3

1.0%

6.32

4

1.5%

6.65

3.5

3

2.5

2

1.5

S.No

% of fiber added

28days strength (N/mm2)

1

CC

4.95

2

0.5%

5.69

3

1.0%

6.32

4

1.5%

6.65

% of polyester & glass fibers

Cc

0.50%

1.00%

1.50%

% of polyester & glass fibers

Cc

0.50%

1.00%

1.50%

% of polyester & glass fibers

% of polyester & glass fibers

28 days

28 days

1

0.5

0

1

0.5

0

Cc

Cc

0.50%

0.50%

1.00%

1.00%

1.50%

1.50%

7

6

5

4

3

7

6

5

4

3

28 days

28 days

2

1

0

2

1

0

split tensile strength in Mpa

split tensile strength in Mpa

Flexural strength in Mpa

Flexural strength in Mpa

Fig .7 Variation of Split tensile strength at 28days

Fig 10 Variation of Flexural strength at 28days

Table.10. Flexural strength test results (75% – 25%)

S.No

% of fiber added

28days strength (N/mm2)

1

CC

4.95

2

0.5%

5.23

3

1.0%

5.98

4

1.5%

6.14

7

6

5

4

3

28 days

7

6

5

4

3

28 days

Cc

0.50%

1.00%

1.50%

Cc

0.50%

1.00%

1.50%

% of polyester & glass fibers

% of polyester & glass fibers

2

1

0

2

1

0

Flexural strength in Mpa

Flexural strength in Mpa

Fig 11 Variation of Flexural strength at 28days

CONCLUSION:

  1. For 0.5% of fibers:

    • 25:75 of polyester and glass fibers the compressive strength is increased 5.2% compared to control mix, the split tensile strength is increased 6.9% compared to control mix, the flexural strength is increased by 19.79% compared to control mix

    • 75:25 of polyester and glass fibers the compressive strength is increased 2 % compared to control mix, the split tensile strength is decreased by 10% compared to control mix, the flexural strength is increased by 6% compared to control mix

    • 50:50 of polyester and glass fibers the compressive strength is increased 2% compared to control mix, the split tensile strength is increased 15.2 % compared to control mix, the flexural strength is increased by 16.16% compared to control mix.

  2. For 1% of fibers :

    • 25:75 of polyester and glass fibers the compressive strength is increased -14% compared to control mix, the split tensile strength is increased44.4% compared to control mix, the flexural strength is increased by 36.9% compared to control mix

    • 75:25 of polyester and glass fibers the compressive strength is increased 6 % compared to control mix, the split tensile strength is increased10.2 % compared to control mix, the flexural strength is increased by 20.8% compared to control mix

    • 50:50 of polyester and glass fibers the compressive strength is increased 7 % compared to control mix, the split tensile strength is increased 24% compared to control mix, the flexural strength is increased by 28.2% compared to control mix

  3. For 1.5% of fibers:

    • 25:75 of polyester and glass fibers the compressive strength is increased 22 % compared to control mix, the split tensile strength is increased 74.5% compared

      to control mix, the flexural strength is increased by 42.2% compared to control mix

    • 75:25 of polyester and glass fibers the compressive strength is increased 14.6% compared to control mix, the split tensile strength is increased 41.2% compared to control mix, the flexural strength is increased by 24.04% compared to control mix

    • 50:50 of polyester and glass fibers the compressive strength is increased 14 % compared to control mix, the split tensile strength is increased 58% compared to control mix, the flexural strength is increased by % compared to control mix

  4. From the above results it is concluded that the optimum combination of volume fraction is 25:75 of polyester and glass fiber respectively. In all the mixes 25:75 combinations of polyester and glass fibres show optimum strength than other combinations.

REFERRENCES:

  1. M.J.Hasan, M.Afroz and H.M.I. Mahmud. An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete International Journal of Civil & Environmental Engineering IJCEE-IJENS Vol: 11 No: 03

  2. Chintan Khatri, Jenish M Mistry, Anuj K Chandiwala. An Experimental study on Rice Husk Ash and Glass Fiber Reinforced Concrete International Journal of Advance Engineering and Research Development. Volume 2,Issue 12,December-2015

  3. Clarke, J., Peaston, C. and Swannell, N. (2007). Guidance on the use of Macro-synthetic-fiber reinforced Concrete. The Concrete Society, Technical Report No. 65, 1-2.

  4. Kosmatka, S., Kerkhoff, B. and Panarese, W. (2002). Design and Control of Concrete Mixtures. 14th Edition, Portland cement Association, Fibers (ch. 7), 121-126.

  5. Majdzadeh, F., Soleimani, M. and Banthia, N. (2006). Shear Strength of Reinforced Concrete Beams with a Fiber Concrete Matrix. Canadian Journal of Civil Engineering, 33(6), 726-734.

  6. CECS 38 (China Civil Engineering Institute Code) (2004). Technical specification for fiber reinforced concrete structures. China Planning Press.

  7. British Standards Institution. (2009). Testing hardened concrete, Part 3: Compressive strength of test specimens.

    BSI, London, BS EN 12390-3, 5-9

  8. British Standards Institution. (2009). Testing hardened concrete, Part 6: Tensile splitting strength of test specimens.

    BSI, London, BS EN 12390-3, 7-9

  9. JSCE-SF6. (1990). Method of test for shear strength of Steel Fiber Reinforced Concrete (SFRC). Japan Society of Civil Engineers, SF6, 67-69.

  10. Recommendations for design of beam-column-joints in monolithic reinforced concrete structures, American Concrete Institute, ACI 352R-02, ACIASCE, Committee 352, Detroit, 2002.

  11. Leon, R.T., Shear Strength and Hysteretic Behavior of Beam-Column Joints, ACI Structural Journal, V.87, No.1,

    Jan-Feb, 1990, pp. 3-11

  12. Park, R., and Paulay, T., Reinforced Concrete Structures,

    John Wiley and Sons, 1975

  13. Paulay, T. And Priestley, M.J.N., Seismic Design of Reinforced Concrete and Masonry Buildings, John Wiley and Sons, 1992,

  14. Ramamurtham.S – Design of reinforced concrete structures

  15. Ashok k. Jain – Reinforced concrete limit state deign – IS 456: 2000- Plain and Reinforced Concrete Code of Practice

Leave a Reply