Experimental Investigations to Augment The Heat Transfer Rate In a Double Pipe Heat Exchanger Using Tube Inserts

DOI : 10.17577/IJERTV6IS120105

Download Full-Text PDF Cite this Publication

Text Only Version

Experimental Investigations to Augment The Heat Transfer Rate In a Double Pipe Heat Exchanger Using Tube Inserts

P. Keshav

Jawaharlal Nehru Technological University, Hyderabad, India.

Abstract Heat transfer augmentation or enhancement refers to the process of increasing the heat transfer co-efficient which leads to the improvement in the performance of the system. Heat transfer enhancement is very important in many engineering applications to increase the performance of heat exchangers. Heat transfer enhancement techniques are broadly classified into two types. They are: Active Techniques and Passive Techniques. The active techniques require external power like surface vibrations, electrical fields etc. The passive techniques are those which do not require any external power like different types of inserts which are used to disturb the flow thereby creating turbulence for the enhancement of heat transfer. Previously most of the researchers had conducted experiments for the enhancement of heat transfer using different inserts.

Keywords Enhancement, heat transfer, counter flow heat exchanger, CFD Analysis, passive technique, Inserts

  1. INTRODUCTION

    Heat exchanger is a piece of equipment built for efficient heat transfer from one medium to another. They facilitate the exchange of heat between two fluids that are at different temperatures while keeping them from mixing each other. Different applications of heat exchanger are condensers, evaporators, boilers conditionation and refrigeration etc. Heat exchanger is used in automobile radiators and coolers. Heat exchangers are also abundant in chemical and process industries. Heat exchangers are popular used in industrial and engineering applications. The design procedure of heat exchangers is quite complicated, as it needs exact analysis of heat transfer rate, efficiency and pressure drop apart from issues such as long term performance and the economic aspect of the equipment. By incorporating different techniques we conclude that heat transfer coefficient increases with the cost of pressure drop. In recent years, the high cost of energy and material has resulted in an increased effort aimed at producing more efficient heat exchange equipment. Furthermore, sometimes there is a need for miniaturization of a heat exchanger in specific applications, such as space application, through an augmentation of heat transfer. For example, a heat exchanger for an ocean thermal energy conversion(OTEC) plant requires a heat transfer surface area of the order of 10000 m2/MW. Therefore an increase in the efficiency of the heat exchanger through an augmentation technique may result in a considerable saving in the material cost. Furthermore as heat exchanger becomes older, the resistance to heat transfer

    increases owing to scaling or fouling. These problems are more common for heat exchangers used in marine applications and in chemical industries. In some specific applications, such as heat exchangers dealing with fluids of low thermal conductivity (gases and oils) and desalination plants, there is a need to increase the heat transfer rate. The heat transfer rate can be improved by introducing a disturbance in the fluid flow thereby breaking the viscous and thermal boundary layer. However, in the process pumping power may increase significantly and ultimately the pumping cost becomes high. Therefore, to achieve a desired heat transfer rate in an existing heat exchanger at an economic pumping power, several techniques have been proposed in recent years.

  2. HEAT EXCHANGER MATERIAL:

    The exchanger material used in this experiment is MILD STEEL. Mild steel is a very popular metal and one of the cheapest types of steel available. Its found in almost every metal product. This type of steel contains less than 2 percent carbon, which makes it magnetize well. Since its relatively inexpensive, mild steel is useful for most projects requiring huge amounts of steel.

    Because it is a soft material, mild steel is easy to weld, whereas high-carbon steels, such as stainless steel, require the use of specialized welding techniques. Also, electricity can flow through mild steel easily without impacting its structural integrity. Mild steel is a variant of hard steels, which makes it much less brittle and enhances its flexibility.

    Inserts are also made up of Aluminum, the properties of aluminium include: low density and therefore low weight, high strength, superior malleability, easy machining, an excellent corrosion resistor and good thermal and electrical conductor, having 59% the conductivity of copper, both thermal and electrical, while 30% of coppers density, also a non-toxic compound. Aluminium is also very easy to recycle.

  3. EXPERIMENTAL PROCEDURE:

    1. Switch on the geyser and allow the hot fluid (water) to flow in the inner tube.

    2. Open the valve so that cold fluid (water) to flow through the annulus and run the exchanger as a counter flow unit.

    3. See that the pipes run full of water.

    4. Record the inlet and exit temperatures of hot and cold fluid after steady state is attained.

    5. The experiment is done for plain tube with cold fluid (water) mass flow rate constant at full valve opening and hot

      fluid (water) mass flow rate is varied at three valve openings (90, 60 and 30 degrees of the valve openings) respectively.

    6. Repeat the same process for inserts namely trapezoidal strip, wedge shaped strip and cylindrical strip inserts.

    1. Nomenclature

      (J / kg K)

      (W / m K)

      )

    2. Experimental Specifications

      DOUBLE PIPE HEAT EXCHANGER:

      1. INNER DIAMETER OF INNER PIPE = 28.64 mm

      2. OUTER DIAMETER OF INNER PIPE = 42.66 mm

      3. INNER DIAMETER OF OUTER PIPE = 74.74 mm

      4. LENGTH OF HEAT EXCHANGER = 2080 mm

      TRAPEZOIDAL STRIP INSERT:

      1. LENGTH OF THE INSERT = 2100 mm

      2. NO. OF TRAPEZOIDAL STRIPS = 30 mm

      3. HEIGHT OF THE TRAPEZOIDAL STRIP = 25 mm

      4. THICKNESS OF THE STRIP = 12 mm

      5. DIAMETER OF THE CORE ROD = 6 mm

      6. LARGER LENGTH OF THE STRIP = 40 mm

      7. SMALLER LENGTH OF THE STRIP = 20 mm

      8. PITCH DISTANCE BETWEEN THE STRIPS = 70 mm

        (kg / m.s) ( / s )

        ( / s )

        WEDGE SHAPED INSERT:

        1. LENGTH OF THE INSERT=2100 mm

        2. LARGER HEIGHT OF WEDGE STRIP=9 mm

        3. SMALLER HEIGHT OF WEDGE STRIP=4 mm

        4. LARGER LENGTH OF WEDGE STRIP=30 mm

        5. SMALLER LENGTH OF WEDGE STRIP=20 mm

        6. NO. OF WEDGE STRIPS=29

        7. PITCH DISTANCE BETWEEN THE STRIPS=70

          As Surface area of the heat exchanger Density of mercury column

          mm

        8. RECTANGULAR ROD OF 6*6 mm DIMENSIONS IS TAKEN.

        9. THICKNESS OF THE STRIP=6 mm

        10. CHAMFER EDGE INCLINATION=1350

          CYLINDRICAL STRIP INSERT:

          1. LENGTH OF THE INSERT=2100 mm

          2. NO. OF PROFILES=51

          3. PITCH DISTANCE BETWEEN THE PROFILES=40 mm

          4. DIAMETER OF THE CYINDRICAL PROFILE=6 mm

          5. HEIGHT OF THE CYLINDRICAL PROFILE=9 mm

          6. RECTANGULAR ROD OF 6*6 mm DIMENSIONS IS TAKEN.

          7. THICKNESS OF THE PROFILE=6 mm

    3. Equations

      1. APPROACH 1:EXPERIMENTAL CALCULATIONS

        As=

      2. APPROACH 2:THEORITICAL CALCULATIONS:

        0.4 For heating of fluids

        0.3 For cooling of fluids

      3. Pressure drop calculations:

        g

      4. Graphs:

    Overall heat transfer coefficient (Experimental and Theoretical) (w/m2k ) vs Mass flow rate of hot water (kg/sec)

    for plain tube

    Overall heat transfer coefficient (w/m2k) vs Mass flow rate of hot water (kg/sec) for plain tube and inserts

    encouragement in my effort to reach my target with in time schedule. I extend my sincere gratitude and thanks to my guide Dr. S.NAGA SARADA, Professor in Mechanical Engineering Department, JNTUH Hyderabad for having confidence in me and providing the support that enabled me to do this project successfully. I would like to thank Dr. J. SURESH KUMAR, Professor and Head of Mechanical Engineering Department, JNTUH Hyderabad for his encouragement and support in completing this work. I sincerely convey thanks to the Principal, JNTUH CEH for providing the financial support to carry out this investigation under TEQIP-II funds successfully. I express everlasting gratitude to my parents and professors of JNTUH CEH for the knowledge they have imparted to me, and lab technicians, friends who guided me in the completion of the project.

    Pressure drop (Pa) vs Mass flow rate of hot water (kg/sec) for plain tube and inserts

  4. CONCLUSIONS

    THREE INSERTS NAMELY TRAPEZOIDAL STRIP, WEDGE SHAPED STRIP, CYLINDRICAL STRIP ARE USED FOR EXPERIMENTAL INVESTIGATIONS TO AUGMENT THE HEAT TRANSFER RATE.

    The following conclusions are drawn from the experimentation:

    Insert-1: Trapezoidal strip insert:-

    A maximum heat transfer enhancement of 388% is obtained compared to plain tube. The increase in pressure drop is 950% as compared to plain tube.

    Insert-2: Wedge shaped insert:-

    A maximum heat transfer enhancement of 392% is obtained as compared to plain tube. The increase in pressure drop is 293% as compared to plain tube.

    Insert-3: Cylindrical strip insert:-

    A maximum heat transfer enhancement of 316% is obtained as compared to plain tube. The increase in pressure drop is 88.7% as compared to plain tube.

    Among all the inserts heat transfer enhancement is highest for wedge shaped insert followed by trapezoidal strip insert but the pressure drop is also maximum for both the inserts. In this context, cylindrical strip insert is recommended as an optimum insert since for the increase in heat transfer rate corresponding increase in pressure drop is minimum.

  5. FUTURE SCOPE

    The same procedure is done by rotating the inserts with a motor and operational rotating speed of the motor depends upon the weight of the insert.

    The inserts can be wounded by wire coils and both these methods could be investigated to create more turbulence so that heat transfer enhancement can be further improved.

  6. ACKNOWLEDGMENT

    The satisfaction of any achievement or accomplishment for completion of major tasks of career will remain incomplete without proper mention of the people who made it possible, whose constant help, guidance and

  7. REFERENCES

  1. Naphon P., Heat transfer and pressure drop in the horizontal double pipes with and without twisted tape insert, International communications in Heat and Mass Transfer, Vol. 33, 2006, pp. 166-175.

  2. A.V.Gawandare, Heat transfer enhancement with different square jagged twisted tapes Int. Journal of Engineering Research and Applications ISSN : 2248-9622, Vol. 4, Issue 3( Version 1), March 2014, pp.619-624.

  3. V. Kongkait paiboon , Heat transfer and turbulent flow friction in a tube fitted with perforated conical rings, International Communications in Heat and Mass Transfer, Vol. 37, 2010,pp. 560-567.

  4. K.V. Sharma, L. Syam Sundar, P.K. Sarma, Estimation of heat transfer coefficient and friction factor in the transition flow with low volume concentration of Al2O3 nanofluid flowing in a circular tube and with twisted tape insert. International communications in Heat and Mass Transfer, Vol. 36, 2009, pp. 503-507.

  5. S. Naga Sarada, A. V. Sita Rama Raju, K. Kalyani Radha, and L. Shyam Sunder, Enhancement of heat transfer using varying width twisted tape inserts, International Journal of Engineering, Science and Technology, vol. 2,2010,pp.107-118.

  6. Smith. Eiamsa-ard, K. Wongcharee, P. Eiamsa-ard, and C. Thianpong, Heat transfer enhancement in a tube using delta-winglet twisted tape inserts, Applied Thermal Engineering, vol. 30, March. 2010, pp. 310 318.

  7. Ramakant Shrivastava,Ravi Kumar,Akhilesh Gupta, Sachida Nand Lal, Heat transfer augmentation by inserts during condensation of refrigerant R-22 inside a horizontal tube, International Refrigeration & Air Conditioning Conference at Purdue, 2006, pp. 1-7

  8. S.N. Sapali, Pradeep A. Patil, Heat transfer during condensation of HFC-134a and R-404A inside of a horizontal smooth and micro-fin tube. International communications in Heat and Mass Transfer, Vol. 34, 2010, pp. 1133-1141.

  9. Veeresh Fuskele, Dr. R.M. Sarviya,Experimenal investigations of heat transfer enhancement in double pipe heat exchanger using twisted dense wire mesh insert. Int. Journal of Advanced Engineering Research and studies, E- ISSN :2249-8974, Vol. 1,2012, pp.05-09.

  10. Promvonge P. and Eiamsa-ard S., Heat transfer behaviors in a tube with combined conical-ring and twisted-tape insert. International Communications in Heat and Mass Transfer, Vol. 34, 2007, pp. 849-859.

  11. J.Kalil Basha, M.Raja, L.Narasimman, kumaravel , Heat transfer enhancement on double pipe heat exchanger by wire coiled and pin wire coiled turbulator inserts. Int. Journal of Research in Aeronautical and Mechanical Engineering ISSN : 2321-3051, Vol. 3, Issue 6, June 2015, Pgs:1-11.

  12. Dr. A.G. Matani , Swapnil A. Dahake , Experimental study of heat transfer enhancement in a pipe using twisted tapes and wire coils. Int. Journal of Application or Innovation in Engineering and Management ISSN : 2319-4847, Vol. 2, Issue 3, March 2013.

  13. Salman S D, Kadhum A A H , Takriff M S , Mohamad A B , CFD analysis of heat transfer and friction factor characteristics in a circular tube fitted with quadrant- cut twisted tape inserts,Mathematical Problems in Engineering; 2013:pp. 108.