Study on Dynamic Properties of RC Buildings with Brick and AAC Walls

DOI : 10.17577/IJERTV6IS060247

Download Full-Text PDF Cite this Publication

Text Only Version

Study on Dynamic Properties of RC Buildings with Brick and AAC Walls

Feba Ray Jacob1

1 PG scholar, Sree Buddha College of Engineering , Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam

Technological University,

Ayathil, Elavumthitta P.O, Pathanamthitta-689625

Linda Ann Mathew2

2Assistant Professor Sree Buddha College of Engineering, Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam Technological University,

Ayathil, Elavumthitta P.O, Pathanamthitta-689625

Abstract: Buildings with masonry infill wall are the most common type of structures used for multi-storey constructions in the developing countries. Masonry Brick infill walls have been used in Reinforced concrete Frame structures as interior and exterior partition walls. Infill walls now a day are considered to be non-load bearing member. Reinforced concrete framed buildings with infills are usually analysed as bare frame, without considering the strength and stiffness contributions of the infills. Nowadays, infills are provided as walls and strut. Here it was provided as a diagonal strut. The width of strut is calculated by equivalent diagonal strut method. For this purpose response spectrum method is taken into consideration and results are obtained in ETABS. The study includes the modelling of building having plan area 25m×15m,the heights are varied from G+3, G+8, G+12 storey and the infill used are Autoclave Aerated Concrete(AAC) and brick . Zone V was considered for this analysis. This paper deals with the comparison of brick infill and AAC infill in low rise, medum rise and high rise buildings and concluded that AAC was good in high rise building and brick was good in low rise and medium rise buildings.

Keywords: Infills, AAC, E-tabs, Diagonal strut

  1. INTRODUCTION

    An earthquake (also known as a quake, tremor or temblor) is the perceptible shaking of the surface of the earth, resulting from the sudden release of energy in the earths crust that creates seismic waves. Earthquakes can be violent enough to toss people around and destroy whole cities. The seismicity or seismic activity of an area refers to the frequency, type and size of earthquakes experienced over a period of time.

    In multi-storey buildings, the RC frame structures are constructed initially due to ease of construction and rapid work in progress. The masonry infilled RC frame buildings are commonly constructed for commercial, residential and industrial buildings in seismic regions. Infilled frames are composite structures formed by the combination of moment resisting plane frame and infill wall. The infills are mostly used as interior partition walls and external walls which are protecting from outside environment to the building according to the requirements. The failure or collapse of buildings during earthquake is due to geological effects, poor form, inadequate design and detailing and poor quality of construction. The infill increases strength and stiffness to the structure. While during analysis, not

    considered the effect of infill due to lack of knowledge between infill and frame. Proper consideration of stiffening effect of infill on the frame is often important as it can considerably alter the behaviour of building in elastic range. Infill reduces the lateral deflection of the building, displacement, bending moments in frame and increasing axial forces in columns this leads to decreasing of probability of collapse.

    The study includes the modelling of building having plan area 25m×15m, the heights are varied from G+3, G+8, G+12 storey and the infill used are AAC and BRICK .The analysis was done by Response Spectrum. Comparison of infill walls in low rise, medium rise and high rise buildings were done on the rest of the chapters.

  2. OBJECTIVES

    1. To determine the effect of brick infill on low rise, medium rise and high rise buildings.

    2. To find the effect of Autoclaved Aerated Concrete (AAC) on low rise, medium rise and high rise buildings.

    3. To compare the base shear and storey drift of varying building height obtained from the dynamic analysis and to obtain better infill.

  3. MODELLING OF BUILDING

    Here the study was carried on G+3, G+8 and G+12with brick and AAC infills on a plan area of 25m×15m.Each storey of 3m height with RC framed structure. Six models including G+3, G+8 and G+12 building were created. Properties are different for different models.

      1. Building Plan And Dimension Details

        The details of frame are obtained from literature review. Material properties include modulus of elasticity, poissons ratio, weight density, thermal coefficient, damping ratio and shear modulus.

        Figure 1 :plan view 25m×15m

        Plan Area

        Structure

        Member Properties

        Size B × D (mm)

        25m x15m

        G+3

        Beams parallel to X axis

        Y axis Columns Slab

        300 × 450

        300 × 300

        450 × 450

        Thickness=125mm

        G+8

        Beams parallel to X axis

        Y axis Columns Slab

        300 × 450

        300 × 300

        650 × 650

        Thickness=125mm

        G+12

        Beams parallel to X axis

        Y axis Columns Slab

        300 × 450

        300 × 300

        750 × 750

        Thickness=125mm

        Table 1:Dimension of the building

        Figure 3.Three dimensional view of G+12 Building with infill(brick and AAC)

        Figure 2.Three dimensional view of G+3 Building with infill(brick and AAC)

        Figure 3.Three dimensional view of G+8 Building with infill(brick and AAC)

      2. Load Formulation

        Present study were considered for Response Spectrum Analysis. Present study were considered for Response Spectrum Analysis. Dead Loads (IS- 875 PART 1) and Live Loads (IS 875 PART 2). In addition to the above mentioned loads, dynamic loads in form of Response Spectrum method were also be assigned.

        • Dead load

          Dead load intensity = 1.5 kN/m2

        • Live Load

    Live Load Intensity specified (Public building) = 4kN/m2 Live Load at roof level =1.5 kN/m2

    3.3.Calculation of Width of Diagonal Strut

    Figure 4.Showing calculation of diagonal strut

    According to Paulay and Priestley,strut width= 0.25d

    3.4 Analysis

    The RC structues with infills were analyzed by Response Spectrum Analysis. The analysis were compared to study the behaviour of the structures. It is a linear dynamic statistical analysis method to indicate the likely maximum seismic response of an elastic structure. A response spectrum is simply a plot of the peak or steady-state

    response (displacement, velocity or acceleration) of a series of oscillators of varying natural frequency that are forced into motion by the same base vibration or shock.

    Figure 5. Response Spectrum Curve

  4. COMPARISON OF RESULTS

    The analysis result obtained were compared to study the seimic performance of RC frame structure with various infills.

    4.1. Base shear and storey drift

    The results obtained from ETABS software is tabulated below. Zone V is considered for the analysis.The base shears of the building were acquired from seismic analysis using the Response Spectrum Analysis corresponding to 5% critical damping considering soil condition medium. Table 5.2 to 5.4 shows the values of storey shear and storey drift for G+3,G+8 and G+12 buildings respectively. The base shear and storey drift at each storey level forboth infills in X and Y directions presented in charts by response spectrum analysis below.

    (a) Base shear

    Base Shear (kN)

    Graphical representation of base shear values are shown in Fig: 5.1 and Fig: 5.2.The result indicate that, the value of storey shear decreases from bottom to top story for all soreys. RC framed structures with brick infills shows better performance than building with AAC infill walls in both X and Y direction in low rise (G+3) and medium rise buildings(G+8).In high rise buildings, AAC was better.

    6000

    5000

    4000

    3000

    2000

    1000

    0

    AAC

    BRICK

    G+3

    G+8

    Storey Height

    G+12

    Figure 6.Graph showing Base shear in X direction

    5000

    4000

    3000

    2000

    AAC

    BRICK

    G+3

    StoreGy+H8eight

    G+12

    1000

    0

    Base shear (kN)

    Figure 7 .Graph showing Base shear in X direction.

    1. Storey Drift

      Storey Drift

      Graphical representation of storey drift values are shown in Fig: 5.3 and Fig: 5.4.The result indicate that, the value of storey drift is maximum at intermediate storey for low rise, medium rise and high rise buildings. RC framed structures with brick infills shows better performance than building with AAC infill walls in both X and Y direction in low rise (G+3) and medium rise buildings(G+8).In high rise buildings, AAC was better.

      0.0006

      0.0004

      0.0002

      AAC

      BRICK

      0

      G+3 G+8 G+12

      Storey Height

      Storey Drift

      Figure 8 .Graph showing Base shear in X direction

      0.0008

      0.0006

      0.0004

      0.0002

      0

      AAC

      BRICK

      G+3 G+8 G+12

      Storey Height

      Figure 9.Graph showing storey Drift in Y direction

  5. CONCLUSION

    In this study Response Spectrum Analysis was done. To analyse the performance of RC framed structure with better infill.

      • The value of storey shear decreases from bottom to top story for all soreys.

      • The value of storey drift is maximum at intermediate storey for low rise,medium rise and high rise buildings.

      • The storey drift and base shear were compared to study the dynamic performance of buildings with brick and AAC infills.

      • The various conclusions obtained from this study are:

        o From maximum storey drift and base shear view,

        • RC framed structures with brick infills shows better performance than building with AAC infills in X and Y direction in low rise(G+3) and medium rise buildings (G+8).

        • RC framed structures with AAC infills shows better performance than building with brick infills in X and Y direction in high rise buildings (G+12).

        • In G+3 building, RC framed structures with brick infills shows better dynamic behaviour based on base shear (percentage reduction of 17.17% in X direction and 13.99% in Y direction compared to AAC infill walls) and storey drift (percentage reduction of 28.92% in X direction and 31.10% in Y direction compared to AAC infill walls)

        • In medium rise buildings , RC framed structures with brick infills shows better dynamic behaviour based on base shear (percentage reduction of 12.5% in X direction and 14.65% in Y direction compared to AAC infill walls) and storey drift (percentage reduction of 16.56% in X direction and 23.8% in Y direction compared to AAC infill walls)

        • In high rise building (G+12), RC framed structures with AAC infills shows better dynamic behaviour based on base shear (percentage reduction of 9.45% in X direction and 21.79% in Y direction compared to brick infill walls) and storey drift (percentage reduction of 31.64% in X direction and 17.8% in Y direction compared to brick infill walls).

      • Hence we conclude that brick was good for low rise and medium rise building and AAC shows better performance in high rise buildings.

  6. FUTURE SCOPE

Further study can be carried out in irregular buildings with various infill walls.

REFERENCES

  1. B. Bhageri, E.S Firoozabad and M. Yahyaei, Comparative study of static and dynamic analysis of multi storey irregular building, World Academy of Science Engineering and Technology, Vol. 6,

    March 2012, pp. 1847-1851

  2. Etabs tutorial

  3. IS 1893, Indian Standard criteria for Earthquake Resistant Design of structures Part 1: General Provisions and Buildings, Fifth Revision, Bureau of Indian Standards (BIS), New Delhi, 2002.

  4. IS 875, Indian Standard Code of Practice for Design Loads (Other Than Earthquakes) For Building and Structures Part 1: Dead Loads Unit Weights of Building materials and stored materials, Second Revision, Bureau of Indian Standards (BIS), New Delhi, 1987.

  5. IS 875, Indian Standard Code of Practice for Design Loads (Other Than Earthquakes) For Building and Structures Part 2: Imposed Loads, Second Revision, Bureau of Indian Standards (BIS), New Delhi, 1987 .

  6. J Zhou ,G. B Bu and K.N Li Calculation Methods for Inter- Storey Drifts of Building Structures, World Conference on Earthquake Engineering, vol. 1, february 2010 , pp. 835-843.

  7. Kiran Tidke1, Sneha Jangave, International Journal of Innovative Research in Science, Engineering and Technology (An ISO 3297: 2007 Certified Organization) Vol. 5, Issue 7, July 2016

  8. Mohd Zain Kangda, Manohar D. Mehare and Vipul R. Meshram, Study of base shear and storey drift by dynamic analysis, International Journal of Engineering and Innovative Technology,

    Vol. 4, February 2015, pp. 92-101

  9. S.K. Jain, and R. Navin, Seismic over strength in reinforced concrete frames, Journal of Structural Engineering, vol.121, March 1995, pp. 580-585.

  10. S.P. Bhattacharya, and S.K Chakraborty, Estimation of storey shear of a building with mass and stiffness variation due to seismic excitation, International Journal of Civil and Structural Engineering, vol. 1, April 2010 , pp. 635-643.

  11. S.S Patil, S.A Ghadge , C. G Konapur and C .A Ghadge, Seismic Analysis of High-Rise Building by Response Spectrum Method, International Journal of Computational Engineering Research, Vol. 3, March 2013, pp. 272-275

Leave a Reply