Experimental Investigation on Characteristic Strength of Recycled Aggregate Concrete with Admixtures

DOI : 10.17577/IJERTCONV5IS13059

Download Full-Text PDF Cite this Publication

Text Only Version

Experimental Investigation on Characteristic Strength of Recycled Aggregate Concrete with Admixtures

S. Niranjani1, S. Rajagopalan2, S. Rajalakshmi3,

M. Rathnavathi4 Mr. S .Manimaran5 1,2,3,4Student, Department of Civil Engineering,

TRP Engineering College, Trichy, Tamilnadu, India. Assistant professor, Department of Civil Engineering, TRP Engineering College, Trichy, Tamilnadu, India.

Abstract:- The usage of natural aggregate is getting more and more intense with the advanced development in infrastructure area. In order to reduce the usage of natural aggregate, recycled aggregate can be used as replacement materials. Three series of mixes with 25%, 50% and 75% replacement of natural aggregate(NA) with recycled aggregate(RA) were prepared to study the strength and durability characteristic of concrete. In each series fly ash(FA) were replaced with 10% by the weight of cement and silica fume(SF) were replaced with 7.5% by weight of cement and glass fiber with 0.3% is added to the concrete by weight of fine aggregate. The effect of above said replacements on various properties of concrete such as compressive strength, tensile strength, flexural strength test were investigated. These results were compared to the same properties of a control concrete mixture and an acceptable percentage of replacements of NA were obtained. Test results show that concrete containing optimal amount of recycled aggregate and mineral admixture resulted in a good structural concrete in strength and durability aspects.

Keywords: Recycled aggregate, Fly ash, Silica fume, Glass fiber

  1. INTRODUCTION

      1. RECYCLING OF CONSTRUCTION AND DEMOLITION WASTE

        Environment preservation and reduction in the rate of rapidly diminishing natural resources are the key requirement for sustainable development. Many steps have been taken to conserve the natural resources. The large amount of depletion of natural aggregate (NA) and the increased amounts of wastes from construction and demolition going to landfill sites are causing serious problems to handling and safe disposal without causing significant damage to the environment.Therefore efforts are made for conversion of C&DW and industrial wastes into utilizable raw materials for beneficial uses. This phenomenon is discussed by using the principle of 3R i.e. Reduce, Reuse and Recycle.

        It is estimated that the global production of concrete is at an annual rate of 1 m3 per capita. As per the research by Fredonia group, World construction aggregates demand is forecast to 28 billion metric tonnes by the year 2013. India is also one among the top ten users of construction materials.

        Over 1 billion tonnes of C&DW is generated every year worldwide. From environmental point of view, for production of natural aggregates of 1 ton, emissions of 0.0046 million ton of carbon exist where as for 1ton recycled aggregate (RA) produced only 0.0024 million ton carbon is produced. Considering the global consumption of

        10 – 12 billion tons/year of aggregate for concrete production (Tsung et al. 2006), the carbon footprint can be determined for the NA as well as for the RA.

      2. RECYCLING OF INDUSTRIAL WASTES

        Industrial wastes like fly ash (FA) and silica fume (SF) are also available in abundant quantity and create lot of disposal problem. Formation of land-fills in thermal industries is an inevitable problem. To solve the above issues, these waste materials can be used as partial replacer to cement in construction industry. However, the use of FA and SF in construction is nothing new and has a long history of use in concrete. The reduction of Ordinary Portland cement production will reduce carbon dioxide (CO2) emissions, reduce energy consumption and reduce the rate of global warming. Utilization of FA and SF usually provides cost savings as well as improved concrete properties.

  2. REVIEW OF LITERATURE

    The RCA has 3-10% lower density and 3-5 times higher water absorption than the corresponding NA because of the adhered cement paste in the RCA. They also suggested giving prior importance to the density and water absorption; avoid large variations in properties of hardened concrete as well as in achieving fresh concrete of adequate workability, stability and cohesiveness [Limbachiya et al. 2004]. The use of upto 30% RA to replace NA will not have significant adverse effects on RAC cube strength. For higher RA contents, minor alterations to the mix proportions may be needed to ensure that equivalent performance to NAC is achieved.[Dhir et al. 1998]. The addition of steel and polypropylene fibers provide better performance for the concrete. The addition of fly ash in the concrete mixture may adjust the workability and strength losses caused by fibres. [Topcu and Canbaz, 2007]. The investigations carried out in China on performance of RAC on mechanical, durability and structural characteristics for

    the past 15 years (19962011). They concluded that microstructure of RAC is much more complex than that of conventional concrete and mechanical property and durability gets affected when percentage of RA increases [Xiao et al. 2012].An experimental study on the effect of fly ash and silica fume on the properties of concrete subjected to acidic attack and sulphate attack.Changes in physical and chemical properties in the mortars with different replacements by fly ash and silica fume when immersed in 2% H2SO4, 10% Na2SO4 and 10% MgSO4 solutions for 3 years were investigated [Kazuyuki Torii and MitsunoriKawamura ,1994]. They tried with two series of concrete mixtures. Series one consists of replacement of NA with 0, 20, 50 and 100% of RA and cement with 0, 25 and 35% of FA for constant water-cement ratio of 0.55. In series two, water-binder ratio was modified to 0.42 for concrete prepared with FA. They used Class F fly ash to mitigate the lower quality of RA. Specimens were subjected to different tests like compressive strength, drying shrinkage, creep, chloride penetration, carbonation depth and capillary water absorption. They concluded that though the addition of RA reduces strength and affects durability properties, addition of 25 to 35% of fly ash minimizes the drawbacks induced by RA. They encouraged the use of RA in concrete with considerable percentage of FA [Kou and Poon, 2012].

  3. OBJECTIVES

        • To reduce the impact of waste materials on environment

        • To study the behavior of recycled aggregate concrete with flyash, silica fume and glass fiber as a replacement to cement and fine aggregate

        • To find out the % use of RCA feasible for construction

        • To investigate the strength and durability of hardened concrete

        • To reduce cracks and shrinkages in concrete

        • To find out the ways of cost saving

  4. MATERIALS AND ITS PROPERTIES

      1. CEMENT

        The cement used in the present research work was Ordinary Portland Cement with 43 grade. The specific gravity of cement was found out by density bottle method and its value is 3.15, which confirms the permissible value as per IS: 8112.

        S.no.

        Parameter

        Test results

        1.

        Normal Consistency

        28%

        2.

        Fineness of cement

        (%)

        6

        3.

        Specific Gravity

        3.15

        4.

        Initial setting time

        70 min

        Final setting time

        300 min

        Table 1: Properties of cement

      2. FLY ASH

        Fly ash is a by product obtained during the process of combustion of pulverized coal in electric power generating plant. Low calcium fly ash equivalent to ASTM Class F fly ash which was collected from the thermal power plant.The physical and chemical composition of fly ash are shown in table 4.1.2 and 4.2.

        Properties of Fly ash

        Results

        Fineness modulus ash (passing through 75)

        7.5

        Specific surface

        (cm2/g)

        3950

        Specific gravity (g/cc)

        2.4

        Table 2: Physical properties of fly ash

        Description

        NA (%)

        RA (%)

        FA (%)

        Ceme

        nt (%)

        Silica

        fume (%)

        SiO2

        58.54

        56.89

        56.6

        24.5

        92.1

        Al2O3

        17.81

        10.57

        33.71

        7

        0.5

        CaO

        6.17

        19.93

        1.07

        63

        0.5

        Fe2O3

        6.07

        3.85

        3.97

        0.55

        1.4

        Na2O

        4.2

        1.92

        0.16

        0.4

        0.3

        MgO

        2.91

        0.6

        0.42

        0.2

        0.3

        Table 3: Chemical composition of concrete materials

      3. SILICA FUME

        The primary chemical and physical composition of silica fume are shown in table 4.1.2 and 4.3.

        Property

        Result

        Particle size

        0.5 m – 1m

        Pack density

        0.76 gm/cc

        Moisture content

        0.058%

        Specific gravity

        2.6

        Table 4: Physical Properties of Silica fume

      4. GLASS FIBRE

        E-Glass fibres was used and the properties of glass fibres is shown in Table 4.4

        Diameter m

        Specific gravity

        Failure strain

        %

        Elasticity (GPa)

        Tensile strength

        (GPa)

        12

        2.6

        3.0

        80

        2.5

        Table 5: Properties of glass fiber

      5. NATURAL AGGREGATE (NA)

        Crushed granite natural aggregate of size 20 mm (max) which was proven to produce excellent natural aggregate concrete and their particle size distribution satisfying the requirements of IS 2386 1997 was used in

        Recycled aggregate (25,50,75%)

        the present research work. The physical, mechanical properties and the chemical composition of coarse aggregate are given in Table 4.1.2 and Table 4.5Physical and Mechanical properties of Coarse Aggregates

        S.no

        Description

        Coarse aggregate

        Natural aggregate

        Recycled aggregate

        Permissible range as

        per IS2386 (1997)

        1

        Specific

        gravity

        2.7

        2.6

        2.5 to 3

        2

        Fineness modulus

        7.24

        6.99

        6.00 to 8.00

        3

        Water

        absorption(%)

        0.6

        2

        0.1 to 2

        4

        Crushing value

        (%)

        17.77

        33.54

        45

        5

        Impact value

        (%)

        12.88

        18.5

        45

        6

        Abrasion value

        (%)

        17

        14

        30

        7

        Density(g/cc)

        2.60

        2.56

        Table 6: Physical and Mechanical properties of Coarse Aggregates

      6. RECYCLED AGGREGATE (RA)

    Recycled aggregates were obtained from the demolished building. The physical and mechanical properties of recycled aggregates are shown in table 4.5

    Fig 1: Natural Aggregates Fig 2: Recycled Aggregates

  5. METHEDOLOGY

    Selection of materials

    Admixed concrete

    Silica fume (7.5%)

    Strength and durability characteristics (Compressive, split tensile, flexural, water absorption, sulfhateattack)

    Optimum mix selection

    Fly ash (10%) Glass fibre (0.3%)

    Comparison and result

    4.7 FINE AGGREGATE

    River sand which passes through 4.75mm sieve and retained on 150 µm sieve, which satisfies IS 383 -1970 was used as the fine aggregate. The specific gravity and water absorption of fine aggregate was 2.65 and 0.44%.

    4.8. WATER

    The water used for casting and curing concrete test specimens was free of acids, organic matter, suspended solids and impurities which when present can adversely affect the strength of concrete.

    4.8. SUPERPLASTICIZER

    To enhance the workability and strength of concrete chemical admixture known as Sulphonated Naphthalene Formaldehyde based polymer was used.

    Inferences

  6. EXPERIMENTAL DETAILS

      1. MIX PROPORTION

        A mix M25 grade was designed as per IS 10262:2009 and the same was used to prepare the test samples. The design mix proportion is shown in Table 6.1

        Table 7 Different type of mix

        Types

        Constituent materials and

        percentage replacement

        R-0

        Conventional concrete

        R-25

        Concrete containing 25% of RA, 10% of FA, 7.5% of SF, 0.3% of

        GF

        R-50

        Concrete containing 50% of RA, 10% of FA, 7.5% of SF, 0.3% of

        GF

        R-75

        Concrete containing 75% of RA,

        10% of FA, 7.5% of SF, 0.3% of GF

        ( RA- Recycled aggregate, FA- Fly ash, SF- Silica fume, GF- Glass fiber)

      2. COMPRESSIVE STRENGTH TEST

    The steel mould of size 150x150x150 mm is well tightened and oiled thoroughly. The fresh mixed concrete is placed and well compacted through mechanical vibrators and after 24 hours they were allowed for curing in a period of 3, 7, 28 days and they were tested. After the curing period the specimen is taken out from the curing tank and wipes it clean. The dimensions of the specimens and the weight of the specimens were noted down with accuracy. Then the specimen is placed between the loading the surface of the CTM and the load is applied till the specimen fails. The ultimate load at the time of failure is noted down. The test procedures were adopted as per ASTM standards. The load was applied at the rate of 140 kg/cm2/min till the cube breaks.The compressive strength of the specimen was calculated by using the formula

    fc = P/A (N/mm2)

    ratio of 0.45 was casted. The cubes, cylinders and beams were tested for compressive strength, split tensile strength and flexural strength. These tests were carried out at the age of 7 days, 14 days, 28 days and 56 days.

    7.1 COMPRESSIVE TEST

    The compressive strength of RAC is slightly higher than the conventional concrete made from similar mix proportions.But the extent of reduction in strength depends on the source of recycled aggregate, degree of replacement, water cement ratio as well. As per test reslts the strength of recycled aggregate cube is more than target strength, so RCA can be used for construction purpose.

    Where,

    P = Load at which the specimen fails in Newton (N)

    A = Area over which the load is applied in mm2 fc = Compressive Stress in N/mm2

    6.2. SPLIT TENSILE STRENGTH

    Split tensile strength of concrete is usually found by testing concrete cylinder of size 100mm × 200mm. The specimens were tested for its strength as per IS: 516-1959 using a calibrated compression testing machine of 2000KN capacity.The tensile strength of the specimen was calculated by using the formula

    ft =2P/dl (N/mm2)

    Where,

    P = Maximum load in N applied to the specimen d = Measured length in cm of the specimen

    l = Measured diameter in cm of the specimen ft = Tensile strength N/mm2

    6.4 FLEXURAL STRENGTH

    The normal tensile stress in concrete, when cracking occurs in a flexure test is known as modulus of ruptures, i.e. flexural strength. The standard test specimen is a beam of size 500mm × 500 mm × 100mm size. The specimen should be should be cast and cured in the same manner as for casting of cubes. The specimens should be immediately tested on removal from the water. The flexural strength can be finding out by calibrated flexural machine. The flexural strength can be find out by central loading as well as the load is applied through two similar rollers mounted at the third point of the supporting span. The flexural strength can be found out by formula as follows

    Fcr= (PL)/bd2

    Fig 3: Compressive strength test

    Mix design

    Compressive strength (N/mm2)

    7 days

    14 days

    28 days

    R-0

    22.32

    25.36

    30.96

    R-25

    26.67

    29.33

    33.33

    R-50

    25.33

    24.89

    24.44

    R-75

    24.10

    21.78

    20.89

    7 days

    14 days

    28 days

    Compressive Strength,

    N/mm2

    Table 9: Compressive strength test

    Compressive strenth Vs % of RA replacement

    40

    30

    20

    10

    0

    R-25 R-50

    R-75

    % of RA replacement

    Fig 4: Compressive strength for different types of mix

      1. SPLIT TENSILE STRENGTH

        The split tensile strength of RAC is slightly lower than the conventional concrete made from similar mix proportions.

        Where,

        P = Fracture load for beam L = Span

        b = Width of the beam d = Depth of the beam

  7. RESULT AND DISCUSSIONS

The mix proportion for M25 is 1: 1.18: 2.86 and W/C

Fig 5: Split tensile strength test

Mix design

Split tensile strength (N/mm2)

7 days

14 days

28 days

R-0

2.68

3.5

3.75

R-25

1.76

2.97

4.24

R-50

1.84

3.11

4.38

R-75

1.79

2.82

4.10

Split tensile strenth, N/mm2

Table 10: Split tensile strength test

Split tensile strenth Vs % of RA replacement

5

4

3

2

1

0

7 days

14 days

28 days

R-25 R-50 R-75

% of RA replacement

Fig 6: Split tensile strength for different types of mix

    1. FLEXURAL STRENGTH

      The flexural strength of RAC is higher than the conventional concrete and the strength gets decreasing when replacement of RA increases.

      Mix design Compressive strength (N/mm2)

      7 days 14 days 28 days

      R-0 2.84 3.34 3.92

      R-25 3.61 3.79 4.04

      R-50 3.52 3.49 3.46

      R-75 3.44 3.27 3.19

      Flecural strenth , N/mm2

      Table 11: Flexural strength test

      Flexural strenth Vs % 0f RA replacement

      5

      4

      3

      2

      1

      0

      7 days

      14 days

      28 days

      R-25 R-50 R-75

      % of RA replacement

      Fig 7: Flexural strength for different types of mix

      CONCLUSION

      Based on experimental investigation concerning the compressive, split tensile, flexural strength of concrete, the following conclusions are drawn

      • RA content increases compressive strength decreases, but combined effect of admixture and glass fiber gives better performance.

      • The optimum value of compressive strength can be achieved in 25% replacement of RA.

      • The split tensile strength of RAC has been found to be lesser than NAC at all ages of concrete and for all percentage of NA replacements.

      • Use of recycled aggregate up to 25% does not affect the compressive strength and flexural strength as per the findings of the test results.

      • The addition of glass fiber of 0.3% increases the split tensile strength and flexural strength.

      • From this it is concluded that replacement of 25% of RA is suitable for structural construction.

REFERENCES

  1. ACI 214R-02.Evaluation of Strength Test Results of Concrete Reported by ACI Committee 214.

  2. Amnon K. Properties of concrete made with recycled aggregate from partially hydrated old concrete. Cement and Concrete Research 2003: 33(5): 703-711.

  3. ASTM C496/496-M-11.Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens.

  4. Ajdukiewicz A. and Kliszczewicz A. Influence of recycled aggregates on mechanical properties of HS/HPC. Cement Concrete Composites 2002: 24(2): 269-279.

  5. IS 8112:1989. 43 Grade Ordinary Portland Cement Specification

  6. IS 2386:1997. Indian Standard Methods of Test for Aggregates for Concrete

  7. I. B. Muhit (2013), Dosage Limit Determination of Superplasticizing Admixture and Effect Evaluation onProperties of Concrete, International Journal of Scientific& Engineering Research, Volume 4, Issue 3, March-2013

  8. Kou, SC, Poon CS, and Chan D. Influence of fly ash as cement addition on the hardened properties of recycled aggregate. Materials and Structures 2008: 41: 11911201.

  9. Limbachiya MC, Koulouris A, Roberts JJ, and Fried AN. Performance of Recycled Aggregate Concrete. RILEM International Symposium on Environment-Conscious Materials and Systems for Sustainable Development 2004: RILEM Publications SARL:127-136

  10. Corinaldesi V. and Moriconi G. Influence of mineral additions on the performance of 100% recycled aggregate concrete. Construction and Building Materials 2009; 23: 28692876.

Leave a Reply