Groundwater Quality Analysis

DOI : 10.17577/IJERTCONV4IS13016

Download Full-Text PDF Cite this Publication

Text Only Version

Groundwater Quality Analysis

Aswini P. V, Chinnu Mary ,Anusmitha A, Anjana Mohanan,

UG Students, Department of civil Engineering,

Christ Knowledge City, Muvattupuzha, Kerala.

Er. Lakshmipriya A. R

Asst. Professor, Department of Civil Engineering,

Christ Knowledge City, Muvattupuzha, Kerala.

Abstract: Availability of clean drinking water is of utmost importance. Owing to the shortage of clean drinking water in recent years, identifying areas of deteriorating groundwater quality is of great importance. This realization has been the reason for the study of groundwater quality near the industrial estate of Aroor Gram Panchayat in Alappuzha district of Kerala.

The chosen area shows a decline in groundwater quality over the past few decades. Discharge of industrial effluents, unhygienic sewerage with improper methods of toilet waste disposal has contributed to a raising alarm on the quality of groundwater.

Keywords Groundwater quality; aroor gram panchayat; water quality parameters

  1. INTRODUCTION

    The recent boom in the population has increased the stress on water demand. When the surface water is not an available option, an alternative would be ground water. Neglecting the need to conserve our sources can lead to a drastic situation that can render us with not a drop of clean water for drinking. Thus the need arises for evaluating the present quality of groundwater to create awareness about the situation and to take necessary measures for the same. The aim of this study is to evaluate the water quality level by collecting samples from selected wards in the Aroor Gram Pancahayat, near the industrial area. The water quality for drinking purposes shall be determined by assessing some of the important quality parameters, making it possible to identify problems which may need immediate intervention.

  2. LOCATION OF STUDY

    Aroor is a census town in Alappuzha district and it is a suburb of Kochi in the state of Kerala, India. It is a seafood related industrial area at the south of Kochi and the industril hub of Alappuzha district.

    Aroor is the northern most edge of Alappuzha district and lies on the National Highway 47 (India) next to Chandiroor.

  3. SAMPLING AND TESTING

    15 samples have been collected from bore wells in the selected locations around the area during the month of January 2016. The samples have been collected in 2 litres of polyethylene cans and for the bacteriological tests the

    sample was collected in pre-sterilized glass bottles. The samples were tested for the chemical parameters pH, turbidity, hardness, chloride, alkalinity, acidity, dissolved oxygen, iron and biological parameter E.coli.

  4. GROUND WATER QUALITY PARAMETERS

    The following Groundwater quality parameters were tested for the samples collected from the site selected.

    A. pH

    pH is the degree of how acidic/basic water is. The range goes from 0 – 14, with 7 being neutral. pH of less than 7 denote acidity, whereas a pH of greater than 7 denotes a base. pH is really a measure of the relative amount of free hydrogen and hydroxyl ions in the water. As pH can be affected by chemicals in the water, pH is an important indicator of water that is changing chemically.

    B . Hardness

    Hardness is induced by compounds of calcium and magnesium, and by a variety of other metals. Hard water is formed when water oozes through deposits of limestone and chalk which are largely made up of calcium and magnesium carbonates.

    General instruction for categorizing water are: 0 to 60 mg/L (milligrams per liter) as calcium carbonate is classified as soft; 61 to 120 mg/L as reasonably hard; 121 to 180 mg/L as hard; and more than 180 mg/L as very hard.

    1. Turbidity

      Turbidity is the measure of relative transparency of a liquid. It is an optical characteristic of water and is an expression of the amount of light that is diffused by material in the water when a light is shined through the water sample. The higher the magnitude of scattered light, the higher the turbidity. Material that causes water to be turbid includes clay, silt, lightly divided inorganic and organic matter, algae, soluble colored organic compounds, and plankton and other atomic organisms.

      Excessive turbidity, or cloudiness, in drinking water is aesthetically unappealing, and may also represent a health concern. Therefore it is essential to determine the turbidity of water.

    2. Acidity

      Acidity of water is its quantitative capacity to neutralize a strong base to a designated pH.

      Acidity contributes corrosiveness to water and influences certain chemical and biological processes. Acidity due to carbon dioxide is practically important in the field of public water supplies. It can be measured by titrating the sample with standard solution of alkaline reagents. Results are reported in terms of phenolphthalein acidity or total acidity expressed as CaCO3.

    3. Alkalinity

      It is a measure of capacity to neutralize acids. It is primarily due to the salts of weak acids although weak or strong bases may also contribute. Alkalinity is an important parameter involved in corrosion control and in determining the soda ash requirements in softening water by precipitation method. Alkalinity is measured volumetrically by titration with 0.02N H2SO4 or HCl. It is expressed in terms of total alkalinity as CaCO3.

    4. Chloride

    In potable water the salty taste is produced by chlorides. High chloride content is harmful to metallic pipes and agriculture crops. It is an important consideration in selection of supplies for human use, where brackish water must be used for domestic purpose for determining the type of desalting apparatus to be used. Chloride is measured volumetrically by titration with silver nitrate solution. It is expressed in mg/L.

    G . Iron

    Iron is one of the most important parameter of groundwater quality. Excessive concentration of iron in water leads to bitter and astringent taste of water. Also causes scaling of boliers and bacterial promotion in service mains.

    According to Bureau of Indian standards the desirable limit of iron in drinking water is 0.3mg/litre.

    H . Total coliform

    Coliforms are harmful bacteria whose presence in water can lead to serious health issues. It should not be present in water used for consumption purposes.

  5. RESULTS AND DISCUSSIONS

    The test results for the analysed samples are shown in table II. On comparing the obtained results with the IS 10500-2012, it was seen that iron, turbidity and hardness values of most of the samples are greater than its desirable limits. Many of the samples also shows the presence of coliforms in the bacteriological examination thus making it unfit for drinking.

    TABLE I. DESIRABLE LIMITS AS PER IS 10500:2012

    CHARACTERISTICS

    UNIT

    DESIRABLE LIMITS

    pH

    6.5-8.5

    Total Hardness as CaCO3

    mg/l

    200

    Turbidity

    NTU

    1

    Alkalinity

    mg/l

    200

    Acidity

    mg/l

    Chloride

    mg/l

    250

    Iron

    mg/l

    0.3

    1. CONCLUSIONS

From the 15 samples collected and tested it was found that most of the test parameters were beyond thepermissible limit and were not fit for drinking purposes. The source of contamination may be septic tanks too close to the well and the continuous disposal of industrial effluents. Ground water quality surrounding the industrial areas has deteriorated, and the application of polluted groundwater for portability has resulted in increased salt content of soils. However, if the pollution continues unabated it could cause serious problems in the future. Therefore, this study can offer the requisite information for the authority to pursue the sustainable approaches on groundwater management and contamination prevention.

The results obtained helps in making the public, local administrator and the government to be aware of the dilemma of poor groundwater quality prevailing in these areas. Since, in the future the groundwater will have the major share of water supply schemes, plans for the protection of groundwater quality is needed. Hence, our research plays an experimental work on ground water quality assessment in the nearby industrial area of Aroor in Alappuzha district of Kerala.

TABLE II. TEST RESULTS FOR SAMPLES ANALYSED

SAMPLE NO

WARD NAME

pH

HARDNESS

(mg/l)

TURBIDIT Y

ALKALINI

TY (mg/l)

ACIDITY

(mg/l)

CHLORIDE

(mg/l)

IRON (mg/l)

TOTAL COLIFOR M IN 100

ml SAMPLE

1

Puthanaghadi

7.26

598

16

138

274

734

0.10

NIL

2

Puthanaghadi

7.04

224

7.40

92

30

93.97

0.70

1600

3

Gov. Fisheries school

6.70

122

20.10

40

24

22

0.36

NIL

4

Gov. Fisheries school

7.50

594

12.80

212

692

267

0.28

NIL

5

Kottapuram

7.16

380

14.40

174

632

49

0.34

NIL

6

Ammaneyam

7.05

496

11.50

224

78

214

0.25

70

7

Ammaneyam

6.98

304

10.60

160

51

56

1.1

NIL

8

Gov. Hospital

7.18

536

26.60

354

376

189

1.1

14

9

Gov. Hospital

7.45

468

24.20

162

134

162

0.60

NIL

10

HSS

7.63

550

6.70

56

592

42

0.20

23

11

HSS

7.02

248

21.80

82

624

46

1.0

NIL

12

Convent

7.60

672

12.50

120

128

41

0.80

1600

13

Convent

6.76

580

7.70

244

80

158

0.6

23

14

Project Colony

6.96

240

16.6

252

358

33

0.80

140

15

Project Colony

7.23

534

23

246

228

142

0.20

14

ACKNOWLEDGMENT

We convey our sincere thanks to Er. Shwetha Saju, Er. Lakshmipriya A R, Er. Reshma Theresa (HOD of Civil Department) and our parents and friends for their sincere support and constant guidance. Last but not the least, I thank the almighty for his constant blessings showered on me.

REFERENCES

  1. B.Mahalingam, Ramu ,Magdum Deepali Bhauso, P.Jayashree Assessment of Groundwater Quality Using GIS Techniques: A Case Study of Mysore City,International Journal of Engineering and Innovative Technology (IJEIT)2014,Volume 3, Issue 8.

  2. J.Dharmaraja, S. Vadivel, E. Ganeshkarthick Physico- Chemical Analysis of Ground Water Samples of Selected Districts of Tamilnadu And Kerala ,International Journal of Scientific & Technology Research 2012 ,Volume 1, Issue 5.

  3. M.Govindarajan, T.Senthilnatha Ground water quality and its health impact analysis in an industrial area, International Journal of Current Microbiology and Applied Sciences, 2014 Volume 3 , pp. 1028-1034

  4. P. Balakrishnan , Abdul Saleem and N. D. Mallikarjun

    ,Groundwater quality mapping using geographic information system (GIS): A case study of Gulbarga City, Karnataka, India, African Journal of Environmental Science and Technology, 2011, Volume 5, pp. 1069-1084.

  5. Saif UllahKhan, Azmatullah Noor and IzharulHaqFarooqi, GIS Application for Groundwater Management and Quality Mapping in Rural Areas of District Agra, India International Journal of Water Resources & Arid Environments,2015, volume 4, pp 89-96.

  6. T. Subramani, S. Krishnan, P. K. Kumaresan Study of Groundwater Quality with GIS Application for Coonoor Taluk in Nilgiri District ,International Journal of Modern Engineering Research (IJMER)2012, Volume.2, Issue.3.

  7. Sunitha.V ,Muralidhara Reddy.B ,Jagadish Kumar.M , Ramakrishna Reddy.M, GIS based groundwater quality mapping in southeastern part of Anantapur District, Andhra Pradesh, India International Journal Of Geomatics & Geosciences,2012 Volume 2, No 3

  8. Madhu Rani Sinha ,AvnishaDev ,Amita Prasad ,MausumiGhosh

    ,RN Tagore , Physicochemical examination and quality assessment of groundwater (Hand-Pump) around Patna main town, Bihar state, India ,Journal of Chemical and Pharmaceutical Research, 2011,volume 3,pp:701-705

  9. BIS, Indian standards specifications for drinking water. IS: 10500, Bureau of Indian Standards, New Delhi, 2003

Leave a Reply