- Open Access
- Total Downloads : 14
- Authors : Aleesha Alexander, Nimesh Mohan M
- Paper ID : IJERTCONV3IS29053
- Volume & Issue : NCRACE – 2015 (Volume 3 – Issue 29)
- Published (First Online): 30-07-2018
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Retrofitting of Reinforced Concrete Beam with Glass Fiber Reinforced Polymer Strips and Sheet
Aleesha Alexander
PG Student
Dept. Of Civil Engineering
Younus College of Engineering and Technology Kollam, Kerala
Nimesh Mohan M
Assistant Professor Dept. Of Civil Engineering
Younus college of Engineering and Technology Kollam, Kerala
-
INTRODUCTION
Today, Glass Fibre Reinforced Polymer (GFRP) materials are being used worldwide for the retrofitting and repair of deficient and old infrastructures such as bridges and buildings. Over the years these structures have suffered severe strength and stiffness due to aggressive environmental conditions such as humidity, saltwater and alkali solutions. Advanced fibrous composite materials such as GFRP can eliminate the problem of corrosion and substantially increase the strength and stiffness of the internally reinforced with GFRP bars. In the case of Reinforced Concrete (RC) beams, externally strengthened with GFRP plates and fabrics and exposed to aggressive environmental conditions, however the bond between the GFRP plate and surface of the RC beam significantly affects the strength of externally reinforced RC beams. Thus it is essential to investigate the overall response of the RC beams externally strengthened with GFRP plates and fabrics and exposed to different environmental conditions.
The technology industries have increased enormously in the last few decades and looks set for significant further expansion. This has been largely because of the high specific stiffness and strength of these materials. However, other properties such as fatigue resistance, property tailoring and manufacturing flexibility are also of significance in certain applications. GFRP structures in aerospace and other structural applications are generally subjected to some form of cycling loading, i.e. fatigue. In the laboratory, fatigue is generally approximated as a sinusoidally varying load or stress, characterised by the load ratio, frequency and maximum force. This type of loading can be termed standard fatigue (SF). However, real-life loading histories often involve vibrating loads that can propagate in structural elements as cyclic impacts. This phenomenon is known as impact fatigue (IF). IF is of major importance to the structural integrity of components and structures due to its detrimental effect on performance, which can occur after a relatively small number of low amplitude cycles. The external bonding of high-strength Fibre
Reinforced Plastics (FRP) to structural concrete members has widely gained popularity in recent years, particularly in
rehabilitation works and newly builds structure. Comprehensive experimental investigations conducted in the past have shown that this strengthening method has several advantages over the traditional ones, especially due to its corrosion resistance, high stiffness-to-weight ratio, improved durability and flexibility in its use over steel plates. The use of Fibre Reinforced Polymer (FRP) materials in civil infrastructure for the repair and strengthening of reinforced concrete structures and also for new construction has become common practice. The most efficient technique for improving the flexural strength of deteriorated RC members is to externally bond Fibre- Reinforced Polymer (FRP) plates or sheets. FRP composite materials have experienced a continuous increase of use in structural strengthening and repair applications around the world in the last decade.
GFRP can be produced with higher strength and higher modulus of elasticity than steel, hence improving the flexural, shear strength, and deflection of structural member. Furthermore, the corrosion resistance characteristic gives more advantage on using FRP in reinforced concrete where it can be used for structures exposed to corrosive condition. The usage of FRP as reinforcement is very new and restricted to rehabilitation work on buildings. The main reason is because the lack of experience in handling this material and cost of using it.
Fibre Reinforced Polymer (FRP) composites are widely used for strengthening concrete structures because they have many advantages over conventional strengthening methods. Much research has been carried out over the past decade into the performance of concrete beams strengthened in shear with externally bonded FRP composites. Previous experimental studies have shown FRP composites are effective in increasing the shear capacity of Reinforced Concrete (RC) beams. Despite numerous interesting studies, the shear behaviour of RC beams strengthened with FRP is not well understood. The majority of tests have been carried out on simply supported beams without steel stirrups strengthened with complete side wrap, U-wrap or full wrapping of the section with Glass Fibre Reinforced polymer (GFRP) sheet.
-
MATERIALS
-
Cement: Ordinary Portland cement of 53 grade conforming to IS 12269:1987 was used for the study.
-
Fine aggregate: M-sand with 4.75 mm maximum size was used as fine aggregate.
-
Water: Potable water is generally considered as being acceptable.
-
GFRP Sheet: Glass Fibre Reinforced Polymer sheet were used for retrofitting the beam.
-
Epoxy Resin: To bind the GFRP sheet with RC beam.
The aim of preliminary investigation studies was to obtain the mix proportion for concrete. Then the properties of constituent materials were determined.
-
-
MIX DESIGN
Concrete mix of M25 grade was used for all beams and it was designed as per IS 10262:2009 and the mix proportion was obtained as 1(cement):1.946(sand):3.085(gravel) by weight. The water/cement ratio was 0.52.
-
Specimen details
The test program consisted of twenty six R.C.C. beams categorized into thirteen groups. The beam has a cross section of (150 ×100) mm with an overall length of 1200mm.
Fig.1. Cage of Beam
-
Reinforcement details
All beams were reinforced with two numbers of 10 mm diameter steel bars in tension side (bottom) and two numbers of 8 mm diameter steel bars in compression side (top). All beams were provided with 10 numbers of 6 mm diameter steel stirrups. Beams were tested simply supported and were subjected to two point loads symmetrically placed at equal distance from the center line of the beam.
Fig.2. Reinforcement details (flexural)
-
-
APPLICATION PROCEDURE OF GFRP
WRAPPING
-
Preparation of specimen surface
As per recommendations of retrofitting work to get strengthening of structural elements, Surface preparation is an important task in our experimental work. This task was done with the help of Emery cloth stone for smooth surface and brush for cleaning the dust.
-
Preparation of retrofit test specimens
The CFRP sheets were bonded to the tension face of the specimens after 28 days of casting. Before applying the epoxy, the concrete surface was smoothened and cleaned to insure a good bond between the epoxy glue and the concrete surface. The epoxy was hand-mixed and hand- applied at an approximate thickness of about 1 mm. The bond thickness was not specifically controlled, but the excess epoxy was squeezed out along the edges of the sheet, assuming complete epoxy coverage.
-
Wrapped specimen details
The experimental program consists of strengthening using glass fiber reinforced polymer. The beans of the first group CB were tested with no strengthening or repair considered as control specimens. The beams of the second and third group were strengthened with U shaped GFRP strips of 50mm width spaced at 50mm with single and double layer respectively. Fourth and fifth group of beams were strengthened with 45o angle strips of 50mm width in single and double layer. 600 angle strips were used in sixth and seventh group in single and double layer. Side sheet, full sheet and U sheet wrappings single and double layers were correspondingly used in the eighth, ninth, tenth eleventh, twelfth and thirteenth groups.
TABLE 1 SPECIMEN LABELING
Beam Designation
Experimental Variables
Wrapping style
No. of Layers of FRP
Angle of FRP Wrapping
CB
Control Beam
–
–
US
U wrapping
Single
–
UD
U wrapping
Double
45O AS
Angle wrapping
Single
45O
45O AD
Angle wrapping
Double
45O
60O AS
Angle wrapping
Single
60O
60O AD
Angle wrapping
Double
60O
SSS
Side Sheet wrapping
Single
–
SSD
Side Sheet wrapping
Double
–
FSS
Full Sheet wrapping
Single
–
FSD
Full Sheet wrapping
Double
–
USS
U Sheet wrapping
Single
–
USD
U Sheet wrapping
Double
-
-
RESULTS AND DISCUSSION
-
Properties of fresh concrete
Studies conducted on fresh concrete. Then slump and compacting factor of fresh concrete is given in table 2.
TABLE 2 PROPERTIES OF FRESH CONCRETE
Properties
Value
Slump (mm)
25
Compacting factor
0.8
-
Properties of hardened concrete
-
Cube compressive strength
From the cube compressive strength study under water curing reveals that the age of curing increases the cube compressive strength. Then the compressive strength of concrete mix were determined at 7 and 28 days of curing is
28.89 N/mm2 and 33 N/mm2 respectively.
-
Splitting tensile strength
Splitting tensile strength of cylinder is determined at 28 days of curing is 3.04 N/mm2.
-
Flexural strength of beams
Flexural strength was determined at 28 days of curing is 3 N/mm2.
-
-
Behaviour of flexural beams
All beams were tested under two point loading condition in the loading frame of 200 tonne capacity. Load was applied by oil jack, then these beams were loaded up to the first flexural cracking and it was observed at an average load of 5kN. Only control beams were loaded up to the ultimate load. Twenty four out of twenty six beams wrapped with GFRP strips and sheets for retrofitting and improving the ultimate load when compared with that of control beam. The improvement in ultimate load was more for double layer than that of single layer. The load deflection behaviour of the specimens were studied. The energy absorption capacity which is the area under the load deflection curve and the ductility factor which is the ratio of the deflection at the ultimate load to the deflection at the yield load,were studied. Comparison of results were made between the FRP wrapped strip and sheets specimens and the control beam. The FRP wrapped specimens showed improvement in the properties compared to control beam.
All the beams wrapped with FRP showed improvement in properties when compared to the control beam. There was improvement in the ultimate load of wrapped specimens when compared with that of control beam. The improvement ultimate load was more for double layer than that of single layer. Sixty degree FRP angle strips wrapped beams showed higher improvement in properties when compared to the control beam and the other different types of strip wrapping. Full sheet wrapped beams also shows higher improvement in properties when compared to the control beam and the other different type of sheet and strip wrappings bur it is not economical.
TABLE 3 DETAILS OF BEAM TESTED
Specimen
Ultimate load (kN)
First crack load (kN)
Deflection corresponding to ultimate load
CB
44
12
3.8
US
50
15
4.9
UD
51
17
4.9
45O AS
53
17
4.8
45O AD
54
19
4.7
60O AS
55
20
4.6
60O AD
56
21
4.5
SSS
62
20
5.0
SSD
64
21
5.3
FSS
68
23
4.6
FSD
70
24
4.8
USS
65
22
4.9
USD
67
23
5.2
The results showed that the flexural capacity of the wrapped specimen increases as the area of the wrapping increases. Also, as the number of layers of FRP increased the flexural capacity. The sheet wrapped beams showed better improvement in flexural capacity compared to that of the strip wrapped specimens. Because FRP wrapped area is more in sheet wrapping than that of strip wrapping. The sixty degree angle strip wrapping showed better improvement in flexural capacity compared to other type of strip wrapping. The full sheet wrapping also showed better improvement in flexural capacity compared to other type of sheet wrapping.
Beam Designation
No. of layers of FRP
Percentage increase in flexural capacity compared to control beam
CB
–
–
US
Single
13%
UD
Double
16%
45O AS
Single
20%
45O AD
Double
22%
60O AS
Single
25%
60O AD
Double
27%
Beam Designation
No. of layers of FRP
Percentage increase in flexural capacity compared to control beam
CB
–
–
US
Single
13%
UD
Double
16%
45O AS
Single
20%
45O AD
Double
22%
60O AS
Single
25%
60O AD
Double
27%
TABLE 4 PERCENTAGE INCREASE IN FLEXURAL CAPACITY OF STRIP WRAPPED SPECIMENS COMPARED TO CONTROL BEAM
face associated with spalling of concrete cover (C), a slight drop in the load following the ultimate load (C), and disintegration of the compression zone concrete as a consequence of buckling of the longitudinal steel in the compression zone (D). These are typical flexure behaviour of reinforced concrete beams. All beams behaved in a similar manner, although the distinct events shown in Fig. 3 were not clearly identified in all the cases.
Fig. 3 Idealized load-deflection curve at mid-span
TABLE 5 PERCENTAGE INCREASE IN FLEXURAL CAPACITY OF SHEET WRAPPED SPECIMENS COMPARED TO CONTROL BEAM
45
40
35
LOAD in kN
LOAD in kN
30
25
20
15
10
5
0
0 1 2 3 4
DEFLECTION in mm
Beam Designation
No. of layers of FRP
Percentage increase in flexural capacity compared to control beam
CB
–
–
SSS
Single
40%
SSD
Double
45%
USS
Single
47%
USD
Double
52%
FSS
Single
54%
FSD
Double
59%
Beam Designation
No. of layers of FRP
Percentage increase in flexural capacity compared to control beam
CB
–
–
SSS
Single
40%
SSD
Double
45%
USS
Single
47%
USD
Double
52%
FSS
Single
54%
FSD
Double
59%
Fig.4. Load-deflection curve for control beam 60
50
-
Load deflection behaviour of beams
The specimens were tested under monotonically increasing load until failure. As the load increased, beam started to deflect and flexural cracks developed along the span of the beams. Eventually, all beams failed in a typical flexure mode. Fig. 4.6 shows an idealized load-deflection curve at mid-span of beams. The progressive increase of deflection at mid-span is shown as a function of increasing load. The load-deflection curves indicate distinct events that were taking place during the test. These events are identified as first cracking (A), yield of the tensile reinforcement (B), crushing of concrete at the compression
40
LOAD in kN
LOAD in kN
30
20
10
0
0 2 4 6
DEFLECTION in mm
Fig.5. Load deflection curve for u strip wrap specimen – single layer
60
50
LOAD in kN
LOAD in kN
40
30
20
10
0
0 2 4 6
DEFLECTION in mm
60
50
LOAD in kN
LOAD in kN
40
30
20
10
0
0 2 4 6
DEFLECTION in mm
Fig.6. Load deflection curve for u strip wrap specimen – double layer
60
50
LOAD in kN
LOAD in kN
40
30
20
10
0
0 2 4 6
DEFELCTION in mm
Fig.7. Load deflection curve for 450 angle strip wrap specimen – single layer
60
50
LOAD in kN
LOAD in kN
40
30
20
10
0
0 1 2 3 4 5
DEFLECTION in mm
Fig.8. Load deflection curve for 450 angle strip wrap specimen – double layer
Fig.9. Load deflection curve for 600 angle strip wrap specimen – single layer
-
-
CONCLUSIONS AND SCOPE OF FURTHER
WORK
-
Conclusions
An experimental investigation was carried out to study the effect of glass fiber reinforced polymer strips and sheets to retrofitting the flexural beams. Six different wrapping styles were adopted. In these number of layers of FRP were kept as variables. A total of 26 beams were cast and were tested under monotonic loading. Based on experimental results following conditions are arrived at.
-
Flexural load carrying capacity of retrofitted beam increases with FRP wrap than control beams.
-
The FRP wrapped specimens showed improvement in the ultimate load. As the number of layers of FRP was increased the ultimate load carried by the specimens also increased. In the case strip wrapped specimens 60 degree angle double wrap is better and also in the case of sheet wrapped specimen full sheet wrapped specimen is better.
-
Ultimate and first crack load of 60 degree angle double wrapped specimen is more compared to the other strip wraps and double layer full sheet wrap specimen shows improvement in the first crack and ultimate load compared to other sheet wrap.
-
Wrapping of beams with FRP was found to be an effective method for repair and retrofitting of beams.
-
Flexural retrofitting also increases the shear strength of concrete.
-
-
Scope of further work
-
Attempts can be made to study the shear behaviour of FRP wrapped beams.
-
The work can be extended by using FRP reinforcement bars.
-
Attempts can be made to study the FRP wrapped specimen with more number of layers.
-
Study can be extended by using aramid
REFERENCES
-
Ahmed S. Debaiky, Mark F. Green and Brian B. Hope (2007), Modelling of Corroded FRP Wrapped Reinforced Concrete columns in axial compression.
-
Anders Carolin, Björn Täljsten and Arvid Hejll (2005), Concrete Beams Exposed to Live Load during Carbon Fibre Reinforced Polymer Strengthening.
-
M. Faizan Tahir (2013), Effect of Carbon Fibre Reinforced Polymer Confinement on the Fire Damaged and Un-heated Reinforced Square Columns.
-
Fatih Alemdar ,Regan Gangel, Adolfo Matamoros, Ph.D., A.M.ASCE, Caroline Bennett, Ph.D., A.M.ASCE, Ron Barrett- Gonzalez, Ph.D. ,Stan Rolfe, Ph.D., P.E., Hon.M.ASCE and Hao Liu (2014), Use of CFRP Overlay to Repair Fatigue Damage in Steel Plates under Tension Loading.
-
C.Higgins, G.T.Williams, M.M. Mitchell, M.R. Dawson and D.Howell (2012), Shear Strength of Reinforced Concrete Girders with Carbon Fibre Reinforced Polymer: Experimental Results, ACI Title no.109-S70.
-
Hiran D. Yapa and Janet M. Lees (2014) Rectangular Reinforced Concrete Beams Strengthened with CFRP Straps.
-
Ida Bagus Rai Widiarsa and Muhammad N.S. Hadi (2013), Performance of CFRP Wrapped Square Reinforced Concrete Columns Subjected to Eccentric Loading.
-
Kam Yoke M.Loo,Stephen J.Foster, and Scott T. Smith (2012), Fatigue behaviour of Carbon Fibre Reinforced Polymer Repaired Concrete Beams, ACI Title no.109-S69.
-
Kumar K. Ghosh and Shamim A. Sheikh (2007), Seismic Upgrade With Carbon Fibre Reinforced Polymer of Columns containing Lap Spliced Reinforcing Bars.
-
Muhammad N. S. Hadi, M.ASCE and Ida Bagus Rai Widiarsa (2013), Axial and Flexural Performance of Square RC Columns Wrapped with CFRP under Eccentric Loading.