An Approach Of Flow Measurement In Solar Water Heater Using Turbine Flow Meter

DOI : 10.17577/IJERTV2IS1083

Download Full-Text PDF Cite this Publication

Text Only Version

An Approach Of Flow Measurement In Solar Water Heater Using Turbine Flow Meter

N. R. Kolhare P. R. Thorat

Assistant Professor GEC Aurangabad Assistant Professor SPWEC

Abstract

The cost effectiveness in solar system is very essential to boost its use in domestic applications. A Techno- economical system is designed using microcontroller based turbine flow meter to measure flow of water in solar water heater. There is no need of bulky remote electronics system. Here a turbine is inserted in the pipeline which rotates around its axis the speed of this rotation is directly proportional to the rate of flown.

To measure the flow electronically through non-contact method one arm of the turbine can be made of a magnet and a Hall Effect device attached on the outer side of the pipe. The Hall Effect switch would pick up the passage of the magnetic arm and generates a pulse. By counting the number of pulses per second or minute depending on the speed of the turbine and the desired resolution (i.e. multiplication factor) the flow can be calculated.

  1. Introduction

    Energy is the lifeblood of our society. Solar can be effectively utilized in two ways-either by converting it into heat (Solar thermal) or electricity (Solar photovoltaic cell). With great concerns being voice about the decreasing fossil fuel reserves and increasing environmental pollution resulting from the burning of large quantities of fossil fuel, the use of renewable sources of energy that are never ending and relatively cleaner has gained a lot of importance. Since the eighties a lot of thought has gone into how we can extend the life of our fossil fuel reserves and as a consequence cut down on pollution. A lot of work has been done on using renewable sources of energy like solar, wind, tidal etc.

    Basic Solar Water Heating System

    A Solar water system consists of following major components:

    • Solar Collector(s)

    • Insulated Hot water Tank with Sacrificial Anode

    • Indicating and Control Instruments

      Figure1: Basic Solar Water Heating System

      Controlled Solar Water Heating System

      Figure2: Controlled Solar Water Heating System

      In controlled solar water heater system with the help of feedback from flow meter helps to control mixture temperature in main tank. Hence role of flow meter is most important in such systems. Here cost aspect is most important to make system low cost, as only flow meter is very costly compare to sensor and motor part.

  2. Selection of Flow Meter

    With most liquid flow measurements instrument, the flow rate is determined inferentially by measuring the liquids, velocity or the change in kinetic energy. Velocity depends on the pressure differential that is forcing the liquid through price or conduit. Because the pipe's cross-sectional area is known and remains constant, the average velocity is an indication of the flow rate. The basis relationship for determining the liquid's flow rate in such cases is:

    Q = V x A

    Where, Q = Liquid flow through the pipe V = Average velocity of the flow

    A = Cross-sectional area of the pipe

    Other factors that affect liquid flow rate include the liquid's viscosity and density, and the friction of the liquid in contact with the pipe.

    Direct measurements of liquid flows can be made with positive- displacement flow meters. These units divide the liquid into specific increments and move it on. The total flow is an accumulation of the measured increments, which can be counted by mechanical or electronic techniques

    Principle

    Types

    Differential Pressure

    Orifice Plate, Venturi Tube, Flow Tube, Flow Nozzle, Pitot Tube, Elbow Tap, Variable- Area (Rota Meter)

    Positive Displacement

    Reciprocating Piston, Oval Gear, Nutating Disc, Rotary Vane

    Velocity

    Turbine, Vortex Shedding, Electromagnetic, Ultrasonic Doppler, Ultrasonic Transit Time

    Mass

    Coriolis , Thermal

    Open-Channel

    Weir, Flume

    Table1: Flow Meter Types Turbine Flow Meter

    The turbine flow meter translates the mechanical action of the turbine rotating in the liquid flow around an axis into a user-readable rate of flow (gpm, lpm, etc.).The turbine wheel is set in the path of a fluid stream. The flowing fluid impinges on the turbine blades, imparting a force to the blade surface and setting the rotor in motion. When a steady rotation speed has been reached, the speed is proportional to fluid velocity.There is much different manufacturing design of turbine flow meters, but in general they are all based

    on the same simple principle: If a fluid moves through a pipe and acts on the vanes of a turbine, the turbine will start to spin and rotate. The rate of spin is measured to calculate the flow.

    The turndown ratios may be more than 100:1 if the turbine meter is calibrated for a single fluid and used at constant conditions. Accuracy may be better than +/- 0.1%

    Figure3: Industrial Flow Meter Usage

  3. System Development

    Figure 4: System Block Diagram

    For measuring flow rate of liquid standard sensors can be used which are in flow rate measuring field but cost of these sensors is very high so it is desired to use sensors which are having low cost, in the developed system use the sensors which gives the standard value. For measuring flow rate A1201 or A1202 sensor is used.

    Fluid entering the meter passes through the inlet flow straightened which reduces its turbulent flow pattern and improves the fluids velocity profile. Fluid then passes through the turbine blades causing it to rotate at a speed proportional to the fluid velocity. As each blade passes through the magnetic field, created at the base of the pickoff transducer, AC voltage (pulse) is generated in the pick-up coil (see Figure). These impulses produce an output frequency proportional to the volumetric flow through the meter. The output frequency is used to represent flow rate and/or tantalization of fluid passing through the turbine flow meter.

    Figure 5: Schematic Illustration of Electric Signal Generated by Rotor Movement

    The Turbine Flow Meter is designed to withstand the rigorous demands of the most remote flow measurement applications. Flow Meter maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in oil field water flood project pipelines, in-situ mining operations, offshore facilities and plant locations. Simple to install and service, it can operate in any orientation (horizontal to vertical) as long as the flow direction arrow is aligned in the same direction as the actual line flow. For optimum performance, the flow meter should be installed with a minimum of 10 diameters upstream pipe length and 5 diameters downstream pipe length [19].

  4. Performance Analysis

    Calibration and its Observation

    5

    Sr.

    No.

    Multiplication Factor

    Observed Reading (LPM)

    Actual Reading (LPM)

    1

    1.5

    22

    25

    2

    1.6

    23.5

    25

    3

    1.7

    24

    25

    4

    1.8

    25

    25

    1.9

    26.3

    25

    6

    2.0

    28

    25

    7

    2.1

    29.5

    25

    Table 2: Calibration and its Observation

    35

    30

    25

    20

    15

    10

    5

    0

    Observed reading (LPM)

    Multiplication factor

    35

    30

    25

    20

    15

    10

    5

    0

    Observed reading (LPM)

    Multiplication factor

    1 2 3 4 5 6 7

    1 2 3 4 5 6 7

    Graph 1: Calibration Process

    Comparison between Standard and Experimental Analysis

    Sr.

    Std.

    Std.

    Std.

    System

    Error

    No.

    Volume

    Time

    Flow

    Flow

    (LPM)

    Liter

    Sec.

    Rate

    rate

    LPM

    (LPM)

    1.

    0.00

    60

    0.00

    0.00

    0.00

    2.

    5.52

    60

    5.52

    5.40

    0.12

    3.

    10.18

    60

    10.18

    10.00

    0.18

    4.

    15.28

    60

    15.28

    15.00

    0.28

    5.

    31.32

    60

    31.32

    31.00

    0.32

    6.

    41.40

    60

    41.40

    41.00

    0.40

    Table 3: Comparison between Standard and Experimental Analysis

    100

    80

    60

    40

    20

    0

    1 2 3 4 5 6

    System Flow rate (LPM)

    Std. Flow Rate LPM

    1. P. D. Olivier, and D. Ruffner, Improved turbine meter accuracy by utilization of dimensionless data, Proc. 1992 Nat. Conf. Standards Labs. (NCSL) Workshop and Symp. 595-607, 1992.

    2. ISA-RP 31.1, Specification, installation and calibration of turbine flow meters, Research Triangle Park, NC: ISA, 1977.

    [6] ANSI/ASME MFC-4M-1986 (R1990),

    Measurement of gas flow by turbine meters, NY, NY:ASME.

    [7] API MPM, Ch. 5.3, Measurement of liquid hydrocarbons by turbine meters, 3rd Ed.,

    Graph 2: Comparison Standard and Experimental

    Analysis

  5. Conclusion

    Development of Solar Water Heater Flow measurement using micro controller based Turbine Flow Meter will replace the other conventional system used in Solar Water Heater flow measurement This system eliminates the manual mistakes in flow rate measurements. It increases the accuracy in flow rate measurement.

    This system is more attractive, as it provides automatic operation; hands free, long-range identification supports, as well as cover monitoring applications. Also can be used for different viscosity liquids only by changing multiplication factor Sensors designed in the developed system are very cost effective and accurate.

  6. Author name(s) and affiliation(s)

    1. Prof. N. R. Kolhare is working as a assistant professor in government engineering college Aurangabad.

    2. Prof. P. R. Thorat is a research scholar and working as a assistant professor at Savitribai Phule Womens Engineering College Aurangabad.

  7. References

  1. W. F. Z. Lee, and H. J. Evans, and Reynolds number Density effect on gas turbine flow meters, Trans. ASME, J. Basic Eng., 87 (4): 1043-1057, 1965.

  2. R. E. Thompson, and J. Grey, Turbine flow meter performance model, Trans. ASME, J. Basic Eng., 92 (4): 712-723, 1970.

  3. M. B. Pate, A. Myklebust, and J. H. Cole, A computer simulation of the turbine flow meter rotor as a drag body, Proc. Int. Compute. In Eng. Conf. and Exhibit 1984, Las Vegas: 184-191, NY, NY: ASME, 1984.

Washington, DC: API (Amer. Petroleum Inst.), 1995.

  1. AGA Transmission Meas. Committee Rep. No. 7, Measurement of fuel gas by turbine meters, Arlington, VA: AGA (Amer. Gas Assoc.), 1981.

  2. Int. Recommendation R32, Rotary piston gas meters and turbine gas meters, Paris, Fr.: OIML (Int. Organization of Legal Metrology), 1989.

  3. ISO 9951:1993, Measurement of gas flow in closed conduits – turbine meters, Geneva, Switz.: Int. Organization for Standardization, (also available ANSI), 1993.

  4. T. H. J. J. Van Der Hagen, Proof of principle of a nuclear turbine flow meter, Nucl. Technol., 102 (2): 167-176, 1993.

  5. K. Termaat, W. J. Oosterkamp, and W. Nissen, Nuclear turbine coolant flow meter, U.S. Patent 5,425,064, 1995.

  6. AWWA C704-92, Propeller-type meters for waterworks applications, Denver, CO: Amer. Water Works Assoc., 1992.

  7. ANSI/AWWA C701-88, Cold water meters – turbine type, for customer service, Denver, CO: Amer. Water Works Assoc., 1988.

  8. B. M. Wright, and C. B. McCarron, Maximum forced expiratory flow rate as a measure of ventilatory capacity, Brit. Med. J.: 1041-1047, 1959.

  9. Hemi Sagi & William G. Roberts- Inline flow meters calibration advance methods & solutions. (

    NCSL) 1997 www.atcinc.net

  10. Li-gang, Li-qiao-Zen, Zang hai-Peng- Study of the application of the turbine flow meters. (IEEE) V3 – 445-447.

  11. M. Vishwanathan Microprocessor based flow rate & flow volume indicator common for any flow sensor which gives pulse output 1998 (IEEE) 1083- 1087

  12. Gang-Li Qiao-Zhen Feng Dong- Study on wide range turbine flowmeter-2006 (IEEE) 775-778.

  13. Solar Energy (Principal of Thermal Collection and Storage), by S. P. Sukhatme, J.K.Nayak. , 36- 39.

  14. Solar Energy Utilization, by G. D. Rai., 312-319.