Design and Analysis of A Multifunctional Building
Manju R
Assistant Professor, Department of Civil Engineering
Musaliar College of Engineering and Technology, Pathanamthitta, Kerala, India
Libinmon John Aprem
B. Tech IVth year, Department of Civil Engineering
Musaliar College of Engineering and Technology, Pathanamthitta, Kerala, India
Rahul Krishna
B.Tech th year, Department of Civil Engineering
Musaliar College of Engineering and Technology, Pathanamthitta, Kerala, India
Sreevignesh V R
B.Tech th year, Department of Civil Engineering
Musaliar College of Engineering and Technology, Pathanamthitta, Kerala, India
Noble Sam Louis
B.Tech th year Department of Civil Engineering
Musaliar College of Engineering and Technology, Pathanamthitta, Kerala, India
Abstract- The paper presents a new design of multifunctional building. We propose this building at Jagathy, Trivandrum. The manual designing of building includes the design of pile foundation, design of column, beam, slab, using a set of procedures and building codes such as IS 456. The design of multi-storey building 3B+G+6 by using the softwares AutoCAD 2019, STAAD PRO, SketchUp is carried out.
Keywords: Deflection; Bending moment; Shear force; Multifunctional building.
-
INTRODUCTION
Multifunctional building is a structure that contains at least two different destination spaces. Development of modern urban structures follows the tendencies of efficient space management which manifests itself in the form of a multifunctional building. Multifunctional buildings are absorbing an increasing number of people through an ever- expanding service sector. Present day urban regions are characterized by using very intensive use of area. Nowadays, buildings are being constructed larger and contain greater diverse functions to fulfill the desires of a huge quantity of customers in a single capability. A multi-storey is a building that has multiple floors above the ground. In this project the analysis and design of multi-storey building 3B+G+6 by using the softwares AutoCAD 2019, STAAD PRO, SketchUp and manual designing. We propose this building at Jagathy, Trivandrum. Because waste from industries and community areas is disposed in this site.
-
OBJECTIVES
-
Carry out a complete analysis and design of the structural elements of a multi storey building including foundation, beam, column, slab.
-
Creating plan drawings using AutoCAD.
-
Creating 3D model using SketchUP.
-
Analysis of frame by STAAD PRO
-
-
METHODOLOGY
Jagathy is a place within the city of Thiruvananthapuram in the state of Kerala, is selected for the study and proposed a multifunctional building. Now its a waste dumping area, after the coming of this building the face of the area will change. Soil study and investigation must be done in order to know the strength of the soil and for proper design of the building. The optimum moisture content was obtained as 34%, Liquid limit 3.2%, Specific Gravity 2.7. Loose very fine sand was found upto more than 3m depth.
3 Basement + Ground Floor + 6 Floors are planned and design the structure can be done with the help of AutoCAD and SketchUp software. Multi storied building is to be designed using design codes and analysis with use of STAAD PRO software. The cost estimation of building is done with the help of data obtained.
-
BUILDING INFORMATIONS
In this project the building is the combination of public and private sectors. This building consists of 6 stories. Ground floor is for public space and they are car showroom and restaurant, from 1st floor to 6th floor is for private spaces like IT companies.
Fig. 1. Site plan of proposed site
Fig. 2. 3rd Basement plan
Fig. 3. 2nd Basement plan
Fig. 4. 1st Basement plan
Fig. 5. Ground Floor plan
Fig. 6. 1st Floor plan
Fig. 7. 2nd Floor plan
Fig. 8. 3rd Floor plan
Fig. 9. 4th Floor plan
Fig. 10. 5th Floor plan
Fig. 11. 6th Floor plan
-
3D MODELLING IN SKETCHUP
The proposed building structure was modelled using SketchUP software. The model is prepared as the plan and other details.
Fig. 12. 3D Modelling by SketchUP
-
MODELLING IN STAAD PRO
The proposed building structure was modelled using STAAD. Pro. The geometric properties of various members such as slab, beams, columns etc and material properties were defined and assigned.
Fig. 13. Structural analysis diagram
Fig. 14. 3D view of structure
-
LOAD ACTING
-
Dead Load
Dead loads consist of the permanent construction material loads compressing the roof, floor, wall, and foundation systems, including claddings, finishes and fixed equipment. Dead load is the total load of all of the components of the building that generally do not change over time, such as the steel columns, concrete floors, bricks, roofing material etc. In Staad pro assignment of dead load is automatically done by giving the property of the member. Dead load is calculated as per IS 875 part 1.
Fig. 15. Structure Under Dead Load
-
Live Load
The live load considered in each floor was 3KN/ m2 and for the terrace level it was considered to be 1.5 KN/sq m. The live loads were generated in a similar manner as done in the earlier case for dead load in each floor. This may be done from the member load button from the load case column. Live loads are calculated as per IS 875 part 2.
Fig. 16. Structure Under Live Load
-
Wind Load
The wind load values were generated by the software itself in accordance with IS 875. Under the define load command section, in the wind load category, the definition of wind load was supplied. The wind intensities at various heights were calculated manually and fed to the
software. Based on those values it generates the wind load at different floors. The calculation of wind load is as per IS 875 part 3.
Fig. 17. Wind Load Effect Along X Direction
Fig. 18. Wind Load Effect Along Z Direction
-
-
MANUAL DESIGN AND STAAD ANALYSIS
-
Design of Pile Foundation
Fig. 19. Pile cap arrangement
Service Load = 300 KN Ultimate Load = 300 × 1.5
= 450 KN
Depth of foundation = 6 m
Fck = 40 N/mm2
Fy = 500 N/mm2
Length of pile above ground level is 0.6 m Total length of pile = 6 + 0.6 = 6.6 m Assume a pile of diameter 0.45 m
Pu = 0.4 Fck Ag + ( 0.67 Fy – 0.4 Fck ) Asc
450×103 = 0.4×40×0.45²× + (0.67×500 0.4 ×40) A
Provide 8mm Ø ties at 75mm c/c.
4 SC
ASC = 1410. 39 mm2
For piles of length, L = 30 D = 30×450 = 13500 mm Reinforement is 1.25% of cross section
ASC =
1.25×
100
×0.45² 4
= 1987.03 mm²
Hence provide 10 bars of 16mm Ø with a
clear cover of 50 mm Ties
Lateral reinforcement in the central portion of the pile = 0.2% of gross volume.
Using 8mm dia ties
Volume of one tie = 50 [4 (450 100)] = 70000mm3 If P = Pitch of ties
Volume of piles per pitch = ( × 0 .45² × P) = 158962.5 P
4
Fig. 20. Pile cap detailing
-
Design of circular column
70000 = 0 .2 ×158962.5 P
100
P = 220.17 mm
Maximum permissible pitch = = 450 = 225 mm
2 2
Provide 8mm ties at 200mm c/c
Fig. 21. Column no. 563 in the structure
Lateral Reinforcement near pile ends
Volume of ties = 0.6 % of gross volume of concrete for a length of 3D = 3×45 = 1350mm.
Using 8mm Ø ties AS = 50.24 mm² Volume of ties = 70000 mm3
70000 = 0.006 × ×450² ×P
4
Column no. 563 Span = 3m Diameter D = 1.2m Fck = 40 N/mm2
Fy = 500 N/mm2
P = 73.39
Service Load = Self weight × No. of floors
= 20.3472 KN
Factored Load = 1.5 × 20.3472
= 30.5208 KN
Slenderness Ratio = = 3000 = 2.5
Provide 8 mm diameter helical spirals at a pitch of 30 mm. The STAAD diagrams are following,
1200
Hence column is designed as short column.
Minimum eccentricity,
e
min = [
+
[] = 3000
1200
+ ] = 10mm < 20mm
500 30
500 30
Also 0.05 D = 0.05 × 1200 = 60 mm
Main Reinforcement
According to clause 39.4 of IS 456- 2000
Pu = 1.05[0.4 Fck Ag + ( 0.67 Fy 0.4 Fck ) Asc]
= 30.52×10³ = [0.4×40××1200²] +[ ( 0.67× 500) (0.4× 40)
Fig. 22. Dimensional details of Member 563 in the structure
Asc]
1.05 4
Asc = 5660 mm2
Asc min = 0.8 % of cross section
= ( 0.008××1200² ) = 9043.2 mm²
4
Provide 45 bars of 16 mm diameter
Adopting clear cover 50 mm over spirals
Core diameter = [ 1200 ( 2×50 )] = 1100 mm
Fig. 23. Reinforcement details of Member 563 in the structure
Area of core , Ac = [ ( 3.14 ×
1100²
4
) 9043.2 ]
= 940806.8 mm²
Volume of core, Vc = 940806.8×103 mm2
1200²
Gross area of section , Ag = (3.14×
4
) = 1130400 mm²
Use 8 mm diameter helical spirals at a pitch pmm Vus = ( 1200-100-8) 50× 1000/p)
= 30144000/p mm³/m
According to clause 39.4.1 of IS 456 Vus / Vc < 0.36[(Ag / Ac ) 1] ( Fck / Fy )
P < 75 mm core dia / 6 = 1100 = 183.33 mm
6
Fig. 24. Shear bending diagram of Member 563 in the structure
Fig. 25. Deflection diagram of Member 563 in the structure
P < 3×8 =24 mm
-
Design of beam
Mu = ( 0.87 Fy Ast d ) [1-
Ast Fy]
Fck
= 0.87×500 Ast ×500 [ 1- Ast = 1205.76 mm²
500Ast ]
500×500×40
Provide 6 bars of 16 mm diameter
Check for shear
Fig. 26. Beam no. 621 in the structure
v =
Vu =
86.7×10³
500×500
= 0.3468 N/mm²
Beam no. 621
Pt =
100Ast =
100 ×1205.76
500×500
= 0.482
Span = 12 m Service load = 3 KN Fck = M40
Refer table 19 of IS 456 2000
c = 0.63 > v
Provide nominal shear reinforcements using 8 mm diameter stirrups.
Fy = 500 N/mm2
Load Factor = 1.5
Sv =
Ast 0.87 Fy
0.46
= 2×50.24×0.87×500
0.4×500
= 218.544 mm
Effective span = = 12000 = 600 mm
20 20
Adopt , d = 500 mm
b = 500 mm
0.75d = 0.75×500 = 375 mm
Sv < 0.75d
Adopt spacing of stirrups 210 mm c/c
Effective span = clear span + effective depth
= 12 + 0.5 = 12.5 m
Loads
Self weight = 0.5 × 0.5 × 25 = 6.25 KN/m Live load = 3 KN/m
Total load = 9.25 KN/m = 9.25 ×1.5 = 13.875 KN/m Mu = 0.125 Wu L2
= 0.125×13.875×12.5 ² = 270.99 KNm Vu = 0.5 Wu L
= 0.5×13.875×12.5 = 86.71 KN
Mu limit = 0.138 Fck bd2
= ( 0.138×40×500×500² ) 10-6 = 690 KNm
Mu < Mu limit , section is under reinforced
Fig. 27. Dimensional details of Member 621 in the structure
Fig. 28. Reinforcement details of Member 621 in the structure
Fig. 29. Shear bending diagram of Member 621 in the structure
Fig. 30. Deflection diagram of Member 621 in the structure
D Design of Slab
Clear span = 12 m
Width of support = 500 mm Floor finish = 1 KN/m²
Fck = 40 N/mm² Fy = 500 N/mm²
Depth of slab, d = = 12000 = 480 mm
25 25
Assuming a clear cover of 20 mm and using 8 mm dia bars
d = 480 mm
Effective span = clear span + effective depth
= 12 + 0.48 = 12.48 m
L = 12.48 m
Loads
Self weight = 12 KN/m Floor finish = 1
Total service load = 13 KN/m Ultimate load = 19.5 KN/m
Ultimate moment and Shear force Mu = 0.125 Wu L2
= 379.64 KN/m Vu = 0.5 Wu L
= 121.68 KN
Mu limit = 0.138 Fck bd2
= 1271.808 KNm
Mu < Mu limit, section is under reinforced
Use 10 mm dia bars adopt a spacing of 160 mm & alternate bar are bent up at support.
Distribution bars
Ast = 0.12% of gross cross sectional area
= 576 mm2
Provide 8 mm dia bars @ 250 mm c/c.
-
-
CONCLUSION
-
All the drafting was done using AutoCAD
-
The analysis and design of the entire structure has been completed using STAAD.Pro.
-
The structural components of the building are safe in shear and flexure.
REFERENCES
[1]. Mahesh Ram Patel; R.C. Singh;Analysis of a tall structure using staad pro providing different wind intensities as per 875 part-iii, IJERST , International Journal of Engineering Sciences & Research Technology, May 2017. [2]. Nalwadgi, M., Aman., Vishhal, T., Gajendra. (2016). Analysis and design of multistorey building using STAAD.Pro. International Research Journal of Engineering and Technology. Vol 3, Issue 6, pp. 887-891. [3]. Vikas, M., Lamba, A. (2020). Design and Analysis of Multi Story (G+4) Parking using Staad-pro Software. International Research Journal of Engineering and Technology. Vol 7, Issue 8, pp. 1762- 1766. [4]. Subramani,T.,Sathiyaraj, R., Ravikumar, K., Manivannan, M., Gopalsamy, R. (2019). Planning , Analyzing and Designing of Shopping Complex By Using STAAD Pro. International Journal of Application or Innovation in Engineering & Management. Vol 8, Issue 3, pp. 151-161. [5]. Prabin, K., R. Sanjaynath.. (2018).A Study On Design Of Multi Storey Residential Building -A Review. International Journal of Pure and Applied Mathematics Vol 119, Issue 17, pp. 1314-3395. [6]. Deevi Krishna, C., Santhosh, K. (2017).Analysis And Design Of A (G+ 6) Multi Storey Residential Building Using STAAD Pro.,Anveshanas International Journal Of Research In Engineering And Applied Sciences , Vol 2, Issue 1, pp. 700-704. [7] IS: 875 (Part 1) 1987( Dead Load ). [8]. IS: 875 (Part 2) 1987( Live Load ). [9]. Design Aids For Reinforced Concrete to IS: 456-1978 [10]. IS. 456: 2000