Abstract This paper presents a comprehensive analysis of a medium height reinforced concrete (RC) building, focusing on the influence of sloping ground on its structural behavior. The study involves seismic analysis of a symmetrical RC building with a G+8 configuration, utilizing the response spectrum method. The building is located in seismic zone III, and the analysis is performed using STAAD-PRO V8i software. The primary objective is to investigate the changes in the building's structural response by considering different positions of shear walls on the same slope of the ground. The angle of the sloping ground is fixed at 170 degrees for all models. Three shear wall positions, namely SW-1, SW-2, and SW-3, are analyzed, with SW-2 exhibiting superior performance compared to the other positions. Furthermore, inclined shear wall 2, which is set back from the front of the building, demonstrates the best results. The design specifications conform to IS 1893 (Part 1):200 for medium soil conditions.
Keywords linear static analysis, RC building, sloping ground, shear walls, seismic analysis, response spectrum method, STAAD- PRO V8i, seismic zone III.
-
INTRODUCTION
Seismic behavior of asymmetric building structures has garnered significant attention in global research efforts. Extensive studies have been undertaken to examine the elastic and inelastic seismic response of asymmetric structures, aiming to identify the factors contributing to their vulnerability to seismic events. In this regard, seismic analysis is performed in accordance with the guidelines outlined in IS 1893:2002. The obtained results are then compared with those obtained from another building frame, enabling a comprehensive assessment of the structural performance and seismic vulnerability of asymmetric structures.
-
OBJECTIVE OF THE STUDY
During the analysis of the building, the following aspects were carefully considered to ensure the originality and integrity of the research paper:
-
Structural Resilience: The primary objective was to design a structure capable of withstanding moderate earthquakes anticipated during its service life while maintaining acceptable levels of damage. These earthquakes were defined as Design Basis Earthquakes (DBEs).
-
Building Frame Configurations: The effectiveness of different building frame configurations, including step back and step back & set back frames, was thoroughly investigated. The aim was to evaluate their impact on the overall structural performance.
-
Response Spectrum Analysis: A building with eight stories (G+8) was subjected to analysis using the Response Spectrum method. The analysis specifically focused on sloping ground conditions.
-
Utilization of Standard Response Spectrum: The Response Spectrum defined in IS 1893(PART-1):2002 for medium soil was employed as a reference in the analysis. This ensured conformity to established guidelines and industry standards.
-
Software Utilization: The STAAD-PRO software was employed to perform comprehensive analyses of all building models. This software facilitated accurate and efficient structural evaluations.
-
Base Shear Variation: The variation of base shear in response to changes in the direction of the slope was meticulously examined. This analysis provided insights into the structural behavior under different slope conditions.
-
Time Period Variation: The study also investigated the variation of time period concerning alterations in the direction of the slope. This analysis offered valuable information regarding the dynamic response characteristics of the building.
-
Axial Force Variation: Randomly selected columns, along with their associated moments, were considered to assess the variation of axial forces. This examination contributed to understanding the structural behavior and load distribution within the building.
-
Comparative Analysis: Results obtained from all building models were comprehensively compared. This comparison specifically focused on buildings with the same slope but different directions, as well as identical soil conditions. It enabled an evaluation of the impact of directional changes on the structural response.
-
Load Cases and Combinations: To ensure a thorough assessment, the analysis encompassed various load cases and combinations. This allowed for a comprehensive understanding of the building's performance under different loading scenarios.
Unit weights of Concrete
25 KN/Cum
Unit weights of brick work
19 KN/Cum
Grade of concrete
M30
Grade of steel
Fe 415
-
-
MODELLING
In this research paper, the focus is on a building configuration that consists of eight stories (G+8), with dimensions of 48 m x 32 m. The spacing between columns along the width of the building is 4 m, while along the length, it is 6 m. Each story has a height of 3 m. The primary aim of this study is to analyze the structural behavior of the building by exploring various combinations of shear walls.
The investigation revolves around assessing the impact of different arrangements of shear walls on the overall structural response of the building. By studying these variations, valuable insights can be gained regarding the effectiveness of different shear wall configurations in enhancing the structural integrity and performance of the building.
The analysis will involve a comprehensive examination of the behavior of the building under different loading conditions, such as static loads, dynamic loads, and lateral forces. The performance of the building will be evaluated based on critical factors like lateral stiffness, strength, and stability.
To conduct the analysis, advanced structural analysis software will be employed. The software will enable accurate modeling and simulation of the building's behavior, taking into account the material properties, structural elements, and boundary conditions. The analysis will adhere to established industry standards and regulations to ensure the reliability and credibility of the findings.
The results of this research will provide valuable insights into the optimal configuration of shear walls for buildings with similar dimensions and structural characteristics. The findings will contribute to the advancement of structural engineering practices, offering guidance to architects and engineers in designing buildings that exhibit superior performance and resilience against various load scenarios.
Total height of building
27 m
Height of each storey
3 m
Size of Column
0.85 m X 0.75 m
(at bottom of building)
0.65m X 0.35m
(at center of building)
0.55 m X 0.35 m
(at top of building)
Size of Beam
0.55 m X 0.25 m
Grade of concrete
M-40
Frame type
OMRF/p>
Soil type
Medium soil
Live load
3 KN/m2
Dead load of slab
3.75 KN/m
External wall load
14.25 KN/m
Internal wall load
8.6 KN/m
Inner wall
150 mm
Outer wall
250 mm
Slab thickness
150mm
General specification of the building discusses below
Table 1 : Modelling
The seismic behavior of asymmetric building structures has become a prominent subject of investigation in global research endeavors. Extensive studies have been conducted to explore the elastic and inelastic seismic behavior of these structures, aiming to uncover the underlying causes of their vulnerability to seismic forces. The analysis performed in this research paper aligns with the guidelines outlined in IS 1893:2002, which provides comprehensive guidelines for seismic analysis.
By adhering to these guidelines, the seismic analysis conducted in this study aims to uncover valuable insights into the behavior of asymmetric structures under seismic loads. The analysis considers various parameters, including lateral stiffness, strength, and displacement, to assess the structural response and seismic vulnerability of these buildings.
To facilitate a comprehensive evaluation, the results obtained from the seismic analysis of the asymmetric building structures are compared with those obtained from another building frame. This comparative analysis provides a holistic understanding of the structural response and seismic performance of asymmetric structures in comparison to alternative building configurations.
-
LITERATURE REVIEW
In a study conducted by Chen and Constantinou (1998), a practical system that introduces intentional flexibility to the sloping ground storeys of structures was investigated. The system utilizes Teflon sliders to support a portion of the superstructure, while energy dissipation is achieved through the ground storey ductile column and the Teflon sliders. The seismic response characteristics of a multistory frame were analyzed and discussed using this concept. The results demonstrated that it is feasible to ensure the safety of the superstructures while maintaining the stability of the ground storey.
Chandrasekaran and Rao (2002) focused on the analysis and design of multi-storey reinforced concrete (RC) buildings in seismic regions. Modeling RC multi-storey buildings as structural systems for analysis can be complex. The authors examined two-dimensional and three-dimensional frame systems considering different angles of in-plane and slope, such as 50°, 100°, and 150°. The seismic forces acting on the multistory buildings were analyzed, and various parameters including axial force, shear force, moment, nodal displacement, beam stress, and support reactions were compared with the provisions of the current version of IS:1893-2002 and the previous version IS:1893-1894.
Birajdar B.G. (2004) presented the results of seismic analysis performed on 24 RC buildings with three different configurations: step back building, step back setback building, and setback building. A 3-D analysis considering tensional
effects was conducted using the response spectrum method. The dynamic response properties, such as the fundamental time period, top storey displacement, and base shear in columns, were studied to evaluate the suitability of building configurations on sloping ground. The findings indicated that step back setback buildings are more suitable for sloping ground conditions.
Kadid A. and Boumarkik A. (2005) conducted an experimental pushover analysis to investigate the performance of framed buildings under future expected earthquakes. The study considered three different framed buildings with 5, 8, and 12 stories, respectively, on sloping ground. The analysis compared various parameters, including axial force, bending moment, nodal displacement, and base shear, to evaluate the behavior of the buildings. The results demonstrated that properly designed frames can exhibit satisfactory performance according to seismic codes. The authors concluded that pushover analysis is a relatively simple approach to explore both linear and nonlinear behavior of buildings.
-
MODELS
In this research paper, various models with different combinations of shear walls are considered for analysis. The main models without shear walls and the different combinations are Shown in Following Figures:
Figure 1 : Plan of Building
Figure 2 : 3D View of Position of Column
Figure 3 : Model of Flat Building
Figure 4 : Setback Model
Figure 5: Inclined from Front Model
Figure 6 : Setback Model
-
RESULT AND GRAPH
Through the analysis of the aforementioned models, several parameters have been compared, namely base shear, base moment, absolute displacement, axial force, and bending moment. The results of these parameters are presented in graphical form for easy interpretation and comparison.
-
Base Shear:
The graph illustrates the comparison of base shear along both the x and z directions for all models with different combinations of shear walls. The calculated base shear values are found to be the same along both the x and z directions.
Please note that the specific values and trends of the base shear comparison would be displayed in the graph, allowing for a detailed assessment of the structural behavior and response of the different models.
Base Shear of Main model
Base Shear (KN)
14000
12000
10000
8000
6000
Base moment (KN-M)
300000
250000
200000
150000
100000
50000
0
Maximum base moment along Z
Model
Main model SW 1
SW 2
SW 3
4000
2000
0
14000
Base shear of all model along X & Z
Graph 3 : Maximum Base moment of all models with shear
wall along Z
C. Axial Force of Column
following graphs shows axial force of all main models without any combination of shear wall. In this graph, 20 columns are selected randomly throughout the building to analyze the axial force in column. Axial forces are in Newton.
Axial force of main model Flat
Base shear (KN)
12000
10000
8000
6000
4000
2000
0
Main model Shear wall 1 Shear wall 2 Shear wall 3
6000000
Axial force (N)
5000000
4000000
3000000
2000000
1000000
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
No. of Columns
Inclined
from front Setback
Inclined from side
Setback
one side Setback Two side Setback
Graph 1 : Shows base shear comparison of all models with Main Models without Shear Wall:
5200000
Following graph shows the comparison of the base moment along
5000000
x and along z of main models with shear-wall combination.
4800000
4600000
4400000
-
Base Moment
Graph 4 : Axial force of all main models
Maximum axial force
Base moment (KN-M)
400000
Maximum base moment along X
Axial force (N)
4200000
Flat InclinedSetbackInclinedSetback One Setback Two Setback
Main model SW 1
SW 2
SW 3
300000
200000
Main model
SW 1
from
front
from
side
Model
side
side
100000
0
SW 2
Graph 5 : This graph shows the maximum axial force
comparison with respect to each type of building frame with a combination of all shear walls at different positions.
Model
Graph 2 : Maximum Base moment of all models with shear wall along X
D. Bending Moment of Column (My).
Following graph shows bending moment in randomly selected 20 columns throughout the building along y and along -z direction.
3000
Bending moment (KN-M)
2500
2000
1500
1000
500
0
BM of main model along Y Flat
Inclined from front
Setback
Inclined from side
Setback
one side Setback
Moreover, shear wall 1 shows the minimum axial forces in the columns of the building compared to the other shear wall configurations. This suggests that shear wall 1 effectively resists vertical forces and minimizes the axial forces experienced by the columns.
In terms of bending moment along the y and z directions in the columns, shear wall 2 demonstrates the minimum values compared to the other shear wall configurations. This indicates that shear wall 2 effectively mitigates bending moments, thereby
1 2 3 4 5 6 7 8 9 1011121314151617181920
No. of Columns
Two side
improving the structural performance.
Graph 6 : Bending moment of main models along Y
Overall, the building combination with shear wall 2 consistently exhibits the most favorable results across multiple parameters when compared to other combinations. Additionally, the inclined from front – setback building frame demonstrates superior
Bending moment (KN-M)
3000
2500
2000
1500
1000
500
0
Maximum bending moment along Y
Main model SW 1
SW 2
SW 3
performance compared to other building configurations, as evidenced by the minimum results obtained.
VIII. REFERENCES
The research paper draws upon various authoritative sources and references to support the analysis and findings. These
Flat Inclined Setback Inclined Setback One
Setback Two
Setback
references provide valuable insights and knowledge in the field of
from
front
from
side
Model
side
side
earthquake-resistant design and structural behavior. The following sources have been cited:
Graph 7 : Maximum Bending moment of all models with shear wall along Y
Maximum bending moment along Z
[1] Murthy C.V.R. – "Learning Earthquake Design" (NICEE) [2] Agrawal, Shrikhande Manish – "Earthquake Resistant Design of Structures" (textbook) [3] IS 456:2000 – "Plain and Reinforced Concrete – Code of Practice"Bending moment (KN-M)
2500
2000
1500
1000
500
0
Model
Main model SW 1
SW 2
SW 3
[4] IS 1893 (PART 1):2002 – "Criteria for Earthquake Resistant Design of Structures" [5] Agrawal, P., and Shrikhande M. – "Earthquake Resistant Design of Structures" (Prentice Hall of India Private Limited, New Delhi, India) [6] Applied Technology Council (1996) – "Seismic Evaluation and Retrofit of Concrete Buildings" (ATC-40, Vol 1) [7] Ashraf Habibullah, Stephen Pyle – "Practical Three Dimensional Non- Linear Static Pushover Analysis" (Structure Magazine, Winter 1998) [8] Manoj S. Medhekar and Sudhir K. Jain – "Seismic Behavior, Design and Detailing of RC Shear Walls, Part II: Design and Detailing" (The Indian Concrete Journal, September 1993) [9] B.G. Birajdar, S.S. Nalawade – "Seismic Analysis of Buildings RestingGraph 8 : Maximum Bending moment of all models with
shear wall along Z
-
-
CONCLUSIONS
Among the different combinations of shear walls, it is observed that shear wall 2 exhibits the minimum base shear compared to the other combinations. This indicates that incorporating shear walls has a significant impact on resisting lateral displacement in the building, surpassing the performance of the main models. Proper placement of shear walls proves to be effective in mitigating horizontal forces.
Furthermore, the base moments along the x and z directions are found to be lower in the combination with shear wall 2 compared to the other combinations. This signifies that shear wall 2 contributes to reducing the base moments, indicating enhanced structural stability.
The combination with shear wall 2 also exhibits the minimum absolute displacement in the building, further reinforcing its effectiveness in reducing structural deformations during seismic events.
on Sloping Ground" (13th World Conference on Earthquake Engineering, Vancouver, B.C., Canada, August 1-6, 2004, Paper No. 1472)
[10] IS 456:2000, IS 1893:2002.