Behaviour of Normal, Medium and High Strength Fibrous RC Slab Under Flexure

DOI : 10.17577/IJERTV2IS120190

Download Full-Text PDF Cite this Publication

Text Only Version

Behaviour of Normal, Medium and High Strength Fibrous RC Slab Under Flexure

Behaviour of Normal, Medium and High Strength Fibrous RC Slab Under Flexur

Manjunath Shevatkar*, B.K.Kolhapure**

*Student, Department of Civil Engineering (M.Tech Structures), P.D.A. College of Engineering,

Gulbarga, Karnataka State, India

**Associate Professor, Department of Civil Engineering, P.D.A. College of Engineering,

Gulbarga, Karnataka State, India

An experimental investigation on the behavior of concrete slabs reinforced with conventional steel bars and steel fibers and subjected to flexural loading is presented. An experimental program consisting of tests on steel fiber reinforced concrete (SFRC) slabs with conventional reinforcement and reinforced concrete (RC) slabs was conducted under flexural loading. SFRC slabs include two types of slabs containing steel fibers in two different volume fractions i.e. 1% and 1.5%. The size of slab was fixed. The dimensions of the slabs were (900 x

450 x 50mm and 900 x 450 x 75mm). Tests on conventionally reinforced concrete slabs showed enhanced properties compared to that of RC slabs. The ultimate loads obtained in the experimental investigation were also compared with the theoretical loads for all types of slabs specimens, containing steel fibers in different proportions, have been conducted to establish loaddeflection curves. The various parameters, such as, first crack load, ultimate load and with and without steel fibers have been carried out and comparison was made on significant stages of loading.

Keywords; SFRC Slab, RC Slab, Steel fibers, Flexural loading.

  1. Concrete is the most widely used structural material around the world, because of its higher compressive strength, low cost and can be easily manufactured with the locally available materials [1]. But concrete lacks tensile strength, ductility, fatigue, and resistance to cracking and crack propagation. Direct and flexural tensile strength can be imparted to concrete by embedding the steel rods [2]. A challenge for engineers was created to develop a new construction material since the resulting matrix lacks in ductility and resistance to cracking. As the consequences of research, the use of fibers along with ingredients of concrete was investigated to produce a composite material called Fiber Concrete [3].

    Steel Fiber reinforced concrete is defined as a composite material made with Portland cement, aggregate and addition of discrete discontinuous fibers. Now why should we add such fibers to concrete? Plain unreinforced concrete is a brittle material with a

    low tensile strength and low strain capacity [4]. The role of randomly distributed discontinuous fibers to bridge across cracks that develop, to provide some post cracking ductility [5]. If the fibers are sufficiently strong, sufficiently bounded to material and permit the fiber reinforce concrete to carry significant stress over relatively large strain capacity in the post cracking stage [6]. There are of course other ways of increasing the strength of concrete. The real contribution of fibers to increase the toughness of the concrete under any type of loading.

    Fiber is a small piece of reinforcing material possessing certain characteristic properties. They can be circular or flat. The fiber is often described by a convenient parameter called aspect ratio. The aspect ratio of the fiber is the ratio of its length to its diameter. Typical aspect ratio ranges from 30 to 150. The transformation from a brittle to a ductile type of material would increase substantially the energy absorption characteristics of the fiber composite and its ability to withstand repeatedly applied shock or impact loading.

    Depending on the use for which the fiber reinforced concrete is intended, different types of fibers are used. They are made out of Glass, Carbon, Wood, Akwara, Coir, Polypropylene, Polyethylene, Synthetic, Galvanized Iron, Steel, Organic and Inorganic Fibers etc.

  2. A comparative study has been undertaken to investigate into the flexural behavior of normal, medium and high strength with M20, M40, M60 grade of concrete using fiber at 0%, 1% and 1.5% by volume of concrete. The size of slab is kept constant (450 x 900mm). Two types of slabs were casted with varying thickness i.e. 50mm and 75mm. 18 slabs were casted and tested under 4 point bending (1/3rd two point loading). The main variables are the grade of concrete M20, M40, M60, the thickness of the slab of 50mm and 75mm, the variation of steel fibers at 0%, 1% and 1.5% and also variation of main reinforcement of 1.56% and 1.04%.

  3. To study the Behavior of Normal, Medium and High Strength Fibrous RC Slab Under Flexure.

    1. Materials & Mix proportions

      Ordinary Portland cement of 53 grade satisfying the requirements of IS 8112-1989, from single batch has been used in the present investigation. The coarse fraction consisted of equal fractions of crushed stones of maximum size of 20mm. Fine aggregate used was natural sand with grading conforming to Zone II. High range water-reducing admixture (HRWA) of type Conplast SP-430 is used in the present investigation to enhance workability. Steel fibers of round crimped type with diameter 0.55mm and length 30mm (aspect ratio =

      54) has been used in the present investigation.

      Mix proportions

      M20, M40 and M60 grade concrete with water to cementitious ratio of 0.55, 0.35 and 0.30 in order to achieve workability High range water-reducing admixture (HRWA) of type Conplast SP-430 has been used in the present investigation. The dosage of superplasticizer used for M40 – 1.25% and M60 – 2.5% by weight of cementitious materials for Non fibrous and fibrous concrete respectively and mix proportions for different grades are given in table 1,2 and 3

      Table 1 Mix proportion of M20 grade concrete

      Ingredients

      Proportion

      Water (kg/m3 of concrete)

      186

      Cement (kg/m3 of concrete)

      338.18

      Fine Aggregate (kg/m3 of concrete)

      624.44

      Coarse Aggregate (kg/m3 of concrete)

      1191.20

      Mix Proportion

      W : CM : Fine Agg : Coarse Agg

      0.55:1.0:1.846:3.522

      Table 2 Mix proportion of M40 grade concrete

      Ingredients

      Proportion

      Water (kg/m3 of concrete)

      186

      Cement (kg/m3 of concrete)

      541.42

      Fine Aggregate (kg/m3 of concrete)

      565.66

      Coarse Aggregate (kg/m3 of concrete)

      1078.57

      Mix Proportion

      W : CM : Fine Agg : Coarse Agg : Superplasticer

      0.35:1.0.1.04:2.029:

      1.25%

      Table 3 Mix proportion of M60 grade concrete

      Ingredients

      Proportion

      Water (kg/m3 of concrete)

      150

      Cement (kg/m3 of concrete)

      536

      Fine Aggregate (kg/m3 of concrete)

      581.63

      Coarse Aggregate (kg/m3 of concrete)

      1150

      Mix Proportion

      W : CM : Fine Agg : Coarse Agg : W/b : Superplasticer

      0.30:1.0.1.09:2.15:1.

      p>6:2.5%

    2. Test procedure and test results

  1. Compressive strength

    Cube specimens of size 150mm×150mm×150mm were used for determining compressive strength. 28days compressive test results are given in table 4, where each value represents the average of three specimens

    Table 4 Compressive strength results

    Type of concrete M20

    Compressive strength in N/mm2

    28 days

    Cvc(nf)

    36.62

    Sfrc 1%

    45.48

    Sfrc 1.5%

    52.31

    Type of concrete M40

    Compressive strength in N/mm2

    28 days

    Cvc(nf)

    48.47

    Sfrc 1%

    49.41

    Sfrc 1.5%

    52.75

    Type of concrete M60

    Compressive strength in N/mm2

    28 days

    Cvc(nf)

    71.44

    Sfrc 1%

    72.41

    Sfrc 1.5%

    74.45

  2. Testing of slabs

    Fig. 1: Test Setup for slab

    A typical loading frame as shown in figure-1. The load was applied by a 500KN hydraulic jack through steel section and steel plates acting as two point load.

    The deflection of the slabs were measured using dial gauge before application of the load the initial readings were recorded then the load was gradually applied with constant increment of 2kn and corresponding deflection was recorded for every increment of load and slabs surface was checked for any visible cracks the load at which first crack development is observed and it is noted and corresponding deflection also noted then with

    further increment of the load the occurrence of different cracks and the corresponding load were noted the load was increased till the slabs fail completely and that load is noted as ultimate load and with corresponding deflection

    The test results of the slabs are given in table-5. reinforcement provided as Ast1=1.56% with 4-8mm @ 150mm and 7-6mm@150mm and Ast2=1.02%with 4- 8mm @ 150mm and 7 -6mm@150mm both side

    Table 5: Test results of slabs

    SLAB

    Width b (mm)

    Depth d (mm)

    Lengt h in (mm)

    First crack load Pcr (KN)

    Ultimat e load Pu (KN)

    S1 M20 NF

    450

    50

    900

    14

    22

    S3 M201%F

    450

    50

    900

    20

    32

    S5 M201.5%F

    450

    50

    900

    20

    32

    S2 M20NF

    450

    75

    900

    24

    36

    S4 M201%F

    450

    75

    900

    22

    36

    S6 M20 1.5%F

    450

    75

    900

    26

    40

    S7 M40NF

    450

    50

    900

    12

    28

    S9 M401%F

    450

    50

    900

    16

    32

    S11 M401.5%F

    450

    50

    900

    16

    34

    S8 M40NF

    450

    75

    900

    16

    36

    S10 M401%F

    450

    75

    900

    16

    36

    S12 M401.5%F

    450

    75

    900

    18

    40

    S13 M60NF

    450

    50

    900

    20

    50

    S15 M601%F

    450

    50

    900

    28

    54

    S17 M601.5%F

    450

    50

    900

    32

    58

    S14 M60NF

    450

    75

    900

    36

    64

    S16 M601%F

    450

    75

    900

    36

    66

    S18 M601.5%F

    450

    75

    900

    44

    70

    *S-Slab type

    *F-Fiber

    *NF- Non-fiber

    Discussion on failure pattern of slabs

    Crack pattern of slab M20 50mm thickness without fiber

    Crack pattern of slab M20 75mm thickness without fiber

    Crack pattern of slab M20 50mm thickness 1% fiber

    Crack pattern of slab M20 75mm thickness 1% fiber

    Crack pattern of slab M20 50mm thickness 1.5% fiber

    Crack pattern of slab M20 75mm thickness 1.5% fiber

    Crack pattern of slab M40 50mm thickness without fiber

    Crack pattern of slab M40 75mm thickness without fiber

    Crack pattern of slab M40 50mm thickness 1% fiber

    Crack pattern of slab M40 75mm thickness 1% fiber

    Crack pattern of slab M40 50mm thickness 1.5% fiber

    Crack pattern of slab M40 75mm thickness 1.5% fiber

    Crack pattern of slab M60 50mm thickness without fiber

    Crack pattern of slab M60 75mm thickness without fiber

    Crack pattern of slab M60 50mm thickness 1% fiber

    Crack pattern of slab M60 75mm thickness 1% fiber

    Crack pattern of slab M60 50mm thickness 1.5% fiber

    Crack pattern of slab M60 75mm thickness 1.5% fiber

    • It is observed that as the percentage of fibers increases from 0%, 1% and 1.5% more number of cracks were observed and the failure linear for 0% or are parallel to supports and a for 0% the number of diagonal cracks develops.

    • It is also observed that the failure of slabs with 0% fibers completely crushed were as addition of fibers failure was rather ductile.

    • Same observations are found as in M20 grade concrete but the cracks were bit wider for M40 grade concrete

    • For M60 grade concrete similar observations were found as for M40 grade concrete as its is observed as the strength of the concrete increases from M20, M40 to M60 the cracks were are the straight at higher strength may be because of increase in brittleness of concrete as the thickness of the slabs increases the load carrying capacity increases but at 75mm thickness the failure was with the less no of cracks.

    • 5. Result and Comparison

Comparison between the slabs of M20, M40 and M60 grade

50mm thickness non fiber

Comparison between the slabs of M20, M40 and M60 grade 50mm thickness 1% fiber

Comparison between the slabs of M20, M40 and M60 grade 50mm thickness 1.5% fiber

Comparison between the slabs of M20, M40 and M60 grade 75mm thickness non fiber

Comparison between the slabs of M20, M40 and M60 grade 75mm thickness 1% fiber

Comparison between the slabs of M20, M40 and M60 grade 50mm thickness 1.5% fiber

Comparison between the slabs of M20, M40 and M60 grade 75mm thickness 1.5% fiber

Following conclusion can be drawn:

  1. Result of control specimen

    1. The percentage increase compression strength for M20 concrete with 1% and 1.5% were found to be 18.84%, and 23.25% respectively.

    2. The percentage increase compression strength for M40concrete with 1% and 1.5% were found to be 18.48%, and 19.49% respectively.

    3. The percentage increase compression strength for M60 concrete with 1% and 1.5% were found to be 17.18%, and 18.01% respectively. It is observed that with addition of fibers the strength of concrete improves upto 1 and 1.5%.

  2. Load v/s deflection behavior observed to be linear upto 10% of ultimate load and non-linearity started till the failure of the slabs.

  3. It is observed that as the thickness of the slab increases the load carrying capacity increases and corresponding deflection and crack width and number of cracks also increases. It is also observed that increase in percentage of steel fibers increases the load carrying capacity of the slab.

  4. It is observed that as the thickness of the slab increases the load carrying capacity increases and corresponding deflection and crack width and

    number of cracks also increases. It is also observed that increase in percentage of steel fibers increases the load carrying capacity of the slab at 75mm thickness the cracks were developed were less than for 50mm thickness of slab.

  5. It is observed that as the grade of concrete increases from M20, M40 and M60 there is a increase in the load carrying capacity and deflection of the slabs. It is also observed that at higher strength M60 grade of concrete there is a large increase in load carrying capacity with deflection and crack width compare to M20 and M40 grade of concrete of slabs.

1] J.A.Barros and J.A.Figueiras Experimental Behavior of Fiber Concrete Slabs on Soil 1 Dep. of Civil Eng., School of Eng., Univ. of Minho, Azurém, 4800 Guimarães, Portugal2 Dep. of Civil Eng., Faculty of Eng., Univ. of Porto, Rua dos Bragas, 4099 Porto, Portugal.

2] S. Deepa Shri1 R. Thenmozhi2 An Experimental Investigation on the Flexural Behavior of SCC Ferro Cement Slabs Incorporating Fibers International Journal of Engineering Science and Technology (IJEST)

3] P Sravana,P Srinivasa Rao,T Seshadri Sekhar Flexural Behaviour of Glass Fibre Reinforced Self Compacting Concrete Slabs 35th conference on our world in concrete and structures: 25 – 27 August 2010, Singapore Article Online Id: 100035051.

4] H Sudarsana Rao* J.N.T.A. University, Anantapur,

India Performance of Steel reinforced Sifcon Two

Wayslabs in Flexure 35th Conference on OUR WORLD IN CONCRETE and STRUCTURES: 25 –

27 August 2010, Singapore, Article Online Id: 100035053.

5] Kamal N.M, Universiti Tenaga Nasional, Malaysia Performance of Precast Ferro Cement Panel for Composite Masonry Slab System

6] M. Anitha P.G. Student, Department of Civil Engineering Government College of Technology Experimental Validation of a Theoretical Model Foflexural Capacity of Hybrid Ferrocement Slab European Journal of Scientific Research ISSN 1450-216X Vol.73 No.4 (2012), pp. 512-526© Euro

Journals Publishing, Inc. 2012 http://www.europeanjournalofscientificresearch.co

Leave a Reply