Water Quality Analysis of Various Surface Water (Rivers, Streams and Jhors) in Angul -Talcher Industrial Area of Odisha

DOI : 10.17577/IJERTV2IS120777

Download Full-Text PDF Cite this Publication

Text Only Version

Water Quality Analysis of Various Surface Water (Rivers, Streams and Jhors) in Angul -Talcher Industrial Area of Odisha

S. K. Biswal

Professor, Department of Chemistry IGIT, Sarang

R. K. Send2*

Department of Chemistry IGIT, Sarang

Abstract

River Brahmani is one of the significant sources of water supply for domestic, agricultural and industrial usage in the state of Odisha which flows through the industrial area of Angul Talcher. This industrial township is reputed due to its vast coal mines, three Thermal power plants (two are owned by NTPC and one owned by NALCO) one aluminum smelter plant (of NALCO) and many Ferro alloys industries. This town lies between latitudes 20o 37 N to 21o 10N and longitudes 84o 53E to 85o 28 (fig.1) and situated at an average height of 139 meters above mean sea level. Two major small rivers like Tikira and Nandira confluence with the river Brahmani in the study area.

About sixty water samples were collected during pre monsoon and post monsoon period for the year 2012 .The physico- chemical parameters such as pH, Electrical conductivity, Total Dissolved Solids Alkalinity, Hardness, Fluorides, Chlorides, Sulfates, Nitrate N, Ammoniacal -N, Phosphates, DO, BOD, COD and some heavy metals concentration like Pb, Cd, Hg , Total Cr, As etc were analyzed. The analytical results were compared with the Indian standard (BIS) and international standard (WHO) to assess the suitability of water for drinking and extent of deterioration for other usage.

Key words: surface water pollution; physico-chemical parameter; seasonal variation; Brahamani River.

  1. Introduction

    The quality of water is of main concern for mankind since it is directly related to human welfare for healthy living. Surface water is mainly used for

    domestic need, industries and agriculture purposes in most parts of the world as it is a replenishable resource. Due to unprecedented rapid population growth, urbanization and industrialization, water pollution problem have become increasingly evident and have led to serious ecological and environmental problems. In most cities urban and industrial wastes are generally disposed of without adequate treatment and management.

    The scope of present study is limited to water quality of Angul-Talcher industrial area which is a highly polluted and sensitive zone in the state of Odisha. This township is located between latitudes 20o 37 N to 21o 10 N and longitudes 84o 53 E to 85o 28 E and at an elevation of about 139 meters above mean sea level (MSL).This industrial belt is flanked with a lot of villages surroundings and within the periphery of the industries like Thermal power plant, Aluminum smelter plants, Ferro alloy industries and vast coal mines. Two major small rivers like Tikira and Nandira which carry the urban and industrial wastes, confluence with river Brahmani in the study region.

  2. Methods and Procedures of Investigation The samples were collected from six different locations of the flowing surface water i.e. Tikira (up- stream and down-stream) Nandira (up-stream and down-stream) and river Brahmani (up-stream and down-stream). The present study was carried out for the year 2012, corresponding to pre-monsoon and post-monsoon seasons at a regular interval of 10 samples in a month for each sampling station. Accordingly from six sampling stations, a total of 60 samples were collected in a month. (Location map

figure-1)

Water samples were collected in air tight polypropylene sampling bottles having double stopper facility to its full capacity without entrapping air bubbles inside. The bottles were sterilized before the collection of samples. The temperatures of different water samples were determined at the site by sensitive Red mercury thermometer. The pH was measured by digital pH meter, sodium and potassium by flame photometer (Systronic digital). Total dissolved solid (TDS) was estimated by taking dried weight of the sample in platinum dishes and conductivity was measured by conductivity meter (Elico Make) 4. Analysis of calcium, magnesium and total hardness were done by EDTA method. Sulphate was determined by gravimetric method. Chloride by Mohrs method. Fluoride concentration was measured using Orion ion analyzer EA-940 with chloride ion selective electrode. Dissolve oxygen (DO), COD and BOD were estimated by standard procedure methodology of American Public Health Association (APHA, 1998)1. Heavy metals like Pb, Zn, Cr, Cd, As, Hg, concentration were determined by AAS (Model Perkin Elmer -303) after HClO4, HNO3 and HCl digestion. Standard procedure was adopted using desiccators to find the faecal coli form and total coli form3. The average value of the analysis result for different physico- chemical parameters have been tabulated in table- 1 and table -2 for pre-monsoon and post monsoon seasons respectively.

Table -1 water quality Analysis of various surface water of the study area in pre- monsoon season (Feb-May-2012)

Parameter

Sample Location with Code

S1

S2

S3

S4

S5

S6

pH

6.44

7.75

6.24

7.80

8.12

8.24

Elect. Conduct.

µmhos /cm

224

545

107

608

411

610

TDS (mg/l)

116

262

52

314

184

360

Fluoride (mg/l)

0.40

2.24

0.60

1.62

1.84

2.24

Chloride (mg/l)

10

28

06

37.5

10

28.6

Sulphate (mg/l)

24.22

146.6

10.24

160.

6

124

186

Nitrate N (mg/l)

1.24

0.001

0.02

0.01

011

0.32

Phosphate as PO4 (mg/l)

1.14

0.08

0.94

1.24

0.60

0.64

Na(mg/l)

4.5

6.8

2.8

4.6

12.6

13.20

K (mg/l)

0.9

1.4

0.8

1.24

2.46

2.89

Ca Hardness (mg/l)

85

110

54

120

124

136

Mg Hardness (mg/l)

64

84

32

86

98

90

Total Hardness (mg/l)

250

314

146

218

224

256

DO (mg/l)

8

7.2

6.8

4.8

3.7

4.3

BOD (mg/l)

1.4

0.8

1.24

<1

1.6

<1

COD( mg/l)

22.6

28.64

6.26

9.32

36.2

45.5

Pb (mg/l)

<0.01

<0.04

<0.01

<0.8

<0.0

6

1.24

Cd (mg/l)

<0.004

<0.00

4

<0.00

4

<0.0

04

<0.0

04

<0.00

4

Hg( mg/l)

<0.000

6

<0.00

06

<0.00

06

<0.0

006

<0.0

006

<0.00

06

Cr-Total

0.04

0.8

0.002

0.07

0.63

0.34

Ammoniacal- N as NH3

0.08

1.4

0.85

1.06

2.1

2.24

Faecal coli form as MPN

/ 100ml

22

64

46

88

280

1640

Total coli form as MPN

/100ml

48

96

74

126

420

1880

Table -2 water quality Analysis of various surface water of the study area in post- monsoon season (Oct–Dec2012)

Parameter

Sample Location with Code

S1

S2

S3

S4

S5

S6

pH

6.7

7.5

6.32

8.54

7.74

8.26

Elect. Conduct.

µmhos /cm

202

414

198

556

364

448

TDS (mg/l)

88

224

48

296

158

326

Fluoride (mg/l)

0.6

2.16

0.8

1.54

1.66

1.94

Chloride (mg/l)

16

38

14

34.8

18

26.2

Sulphate (mg/l)

18.8

128.2

8.4

144.

6

122.

7

166.8

Nitrate N (mg/l)

1.2

0.001

0.001

0.02

0.14

0.28

Phosphate as PO4 (mg/l)

1.10

0.06

0.76

1.16

0.8

1.18

Na(mg/l)

3.8

5.42

2.24

3.84

12.2

4

16.46

K (mg/l)

0.6

1.62

0.8

1.36

2.24

2.66

Ca Hardness (mg/l)

76.0

98

58

118

138

168

Mg Hardness (mg/l)

62.0

80.4

44.6

78

104

116

Total Hardness (mg/l)

210.0

278.0

142.0

224

246.

6

262.6

DO (mg/l)

6.4

6.28

6.2

4.22

3.24

3.96

BOD (mg/l)

1.12

0.68

1.16

0.42

1.18

0.48

COD( mg/l)

18.4

26.62

5.84

16.4

34.1

6

42.46

Pb (mg/l)

<0.01

<0.02

<0.01

1.22

<0.0

8

1.28

Cd (mg/l)

<0.00

4

<0.00

4

<0.00

4

<0.0

08

<0.0

04

<0.00

6

Hg( mg/l)

<0.00

06

<0.00

06

<0.00

06

<0.0

006

<0.0

006

<0.00

06

Cr-Total

0.06

1.28

0.06

0.12

0.54

1.22

Ammoniacal- N as NH3

0.04

0.98

0.08

1.78

1.78

2.14

Faecal coli form as MPN

/ 100ml

18

56

42

82

244

1264

Total coli form as MPN

/100ml

38

104

66

124

414

1684

S1Up-stream of river Tikira S2 Down-stream of river Tikira

(Near the confluence point of river Brahmani)

S3- Up-stream of river Nandira (Jhor)

S4-Down-stream of river Nandira (Jhor) (Near the confluence point of river Brahmani)

S5Up-stream of river Brahmani near Samal Barrage S6- Down-stream of river Brahmani (Near Kamalanga)

4. Graphs

8.5

8.0

pH

pH

7.5

7.0

pH-Pre Monsoon pH-Post Monsoon

pH-Pre Monsoon pH-Post Monsoon

6.5

Fig: Sketch of study area

  1. Results and Discussions

    Water samples at six monitoring stations signify a clear picture of physico-chemical characteristics of surface water. The overall concentration of all the parameters given in table -1 and table-2 shows that except some parameters like Electrical conductivity, TDS, Fluoride, Total Hardness and COD at some monitoring station (i.e. down-stream of Brahmani near Kamalanga) remains below the permissible standard.

    6.0

    700

    Electrical Conductivity (µmhos /cm)

    Electrical Conductivity (µmhos /cm)

    600

    500

    400

    300

    200

    1 2 3 4 5 6

    Sampling Station (S) Graph-1

    Electrical Conductivity-Pre Monsoon

    The variation of pH at different monitoring station at downstream of Kamalanga and Brahmani may be due to mixing of industrial effluent from Thermal power plant. A little higher value of Electrical conductivity, TDS, Fluoride, BOD and COD, above permissible limit may be account for the mixing of industrial effluent. But low value of BOD may be due to presence of pathogenic bacteria due to mixing of domestic wastes and waste water runoff directly from Headquarter medical Hospital, Talcher, situated close to river Brahmani. Moreover the faecal coli form and total coli form level were found to higher than the

    permissions able limit5. Within the analysis of some heavy metals like Pb, total Cr, the concentration remains higher than the permissible limit at down- stream of the river gives clear sign of effluent water from coal mines drainage and Thermal power plant mixing at different confluence of river Brahmani from

    100 Electrical Conductivity-Post Monsoon

    1 2 3 4 5 6

    Sampling Station (S) Graph-2

    1.4

    1.2

    1.0

    Cr-Total (mg/l)

    Cr-Total (mg/l)

    0.8

    0.6

    0.4

    0.2

    Cr-Total-Pre Monsoon

    small rivers like, Tikira, Nandira. Moreover the study of seasonal variatins of pre-monsoon and post- monsoon shows that the higher value of different parameters in pre-monsoon periods and lesser value in post-monsoon may be due to dilution factor in rainy season.

    0.0

    Cr-Total-Post Monsoon

    1 2 3 4 5 6

    Sampling Station (S) Graph-3

    DO- Pre Monsoon DO- Post Monsoon

    DO- Pre Monsoon DO- Post Monsoon

    has already been under taken for a more clear picture of surface water quality and ground water quality (near

    8 the ash pond of different Thermal power plants, coal mining drainage and smelter plant) of the most

    7 sensitive industrial zone of the country.

    DO (mg/l)

    DO (mg/l)

    6

    6. References

    5

    4

    3

    1.6

    1.4

    BOD (mg/l)

    BOD (mg/l)

    1.2

    1.0

    0.8

    0.6

    0.4

    1 2 3 4 5 6

    Sampling Station (S) Graph-4

    BOD-Pre Monsoon

    BOD-Post Monsoon

    BOD-Pre Monsoon

    BOD-Post Monsoon

    1 2 3 4 5 6

    Sampling Station (S) Graph-5

    1. APHA (1998), Metal in LS Clesceri, AE Green berg and AD, Easton, Standard method for extraction of water and waste water, American Public Health Association Washington DC.

    2. Muduli, S.D.; et al. (2006) Physico chemical characteristic assessment of Brahmani River Odisha. Poll Res. 25 (4) 763-766.

    3. Panda, R.B.; et al. (2009). Water quality of the Brahmani River an analytical student upstream, mid stream and downstream at effluent discharge point of Talcher industrial complex, Odisha. Jr. of industrial Pollution Control 125 (1) 37 42.

    4. Reza, R., Singh G. (2010) Impact of industrial development on surface water resources in Angul region of Odisha, Int. Jr of Env. Science 1 (4) 514-522.

    5. WHO (1984), Guidelines for water quality (vol.1) Recommendations of World Health Organization, Geneva.

COD-Pre Monsoon COD-Post Monsoon

COD-Pre Monsoon COD-Post Monsoon

50

40

COD (mg/l)

COD (mg/l)

30

20

10

0

1 2 3 4 5 6

Sampling Station (S) Graph-6

5. Conclusion

Out of all these different physico-chemical parameters analyzed, some parameters like BOD, COD, faecal coli form, and some heavy metals like Pb and total Cr beyond permissible limit shows that the river water is deteriorated at the downstream after mixing of effluent of Talcher industrial complex. A detailed studies of all these parameter in every month and seasonal variation

Leave a Reply