An Experimental Investigation Of Effect Of Electrolyte Solution On Material Removal Rate In ECDM

DOI : 10.17577/IJERTV2IS1113

Download Full-Text PDF Cite this Publication

Text Only Version

An Experimental Investigation Of Effect Of Electrolyte Solution On Material Removal Rate In ECDM

1Dept. of mechanical Engg RIT, Sakhrale 415414, M.S.India

2Associate Prof. Dept. of Mechanical Engg RIT, Sakhrale 415414, M.S.India

3 Associate Prof. Dept. of Mechanical Engg, PVPIT, Budhgaon 416304,M.S.India

ABSTRACT

Electrochemical Discharge Machining (ECDM) has been demonstrated to be an alternative spark-based micromachining method for fabricating micro-holes and micro-channels in non-conductive brittle materials. In this paper attempts experiments on ECDM have been carried out according to designed experimental plan based on standard orthogonal array (L9) to identify the effect of electrolyte solution on material removal rate. In controlling the machining performance, such as material removal rate the signal-to-noise (S/N) ratio is performed to find the relative contributions of the main machining parameters, such as applied voltage, electrolyte concentration and inter-electrode gap. The non-conducting and highly brittle Soda lime Glass is used as a work-piece material and aqueous KOH and NaCl is used as electrolyte solution.

  1. INTRODUCTION

    Electrochemical discharge machining (ECDM) is a hybrid non-conventional manufacturing process which combines the features of electrochemical machining (ECM) and electro discharge machining (EDM). It can be successfully used for machining electrically non-conductive advanced engineering materials such as glass and ceramics has shown the possibility of drilling micro- holes by smaller electrodes efficiently and economically. It has been found that the advanced materials

    are difficult to machine by the conventional machining processes. It is no longer possible to produce parts with better surface finish, close tolerances and complex shapes in advanced materials by conventional machining methods. So far, it is still necessary to provide more study for machining of non-conductive brittle materials since they have become key materials in the MEMS field. For example, the glass or quartz is usually bonded with the semi-conductive material due to their transparency, chemical-resistant properties and so on. Likewise, the engineering ceramic is also used often in the high-tech apparatus [9].

    The performance of ECDM, in terms of Material removal rate and rate of machining, is affected by many factors. Relationships between these factors and machining performance are highly non- linear and complex in nature Therefore, it is very difficult to develop a relationship between those factors and the machining performance with conventional mathematical modelling. In this study the performance characteristic such as MRR has been studied using KOH and NaOH as an electrolyte solution [2].

  2. PRINCIPLE OF ECDM

    Fig 2.1: Principle of ECDM process

    The electrochemical discharge phenomenon is clearly demonstrated by the following simple experience. Two electrodes are dipped inside an aqueous electrolyte. The cathode is chosen with a much smaller surface than the anode. When the D.C. voltage is applied electrolysis happens and Hydrogen gas bubbles are formed at the tool-electrode (cathode) and oxygen bubbles at the counter electrode (anode). When the voltage is increased, the current density

  3. EXPERIMENTAL SETUP

    increases too and more and more bubbles grow forming a bubble layer around the electrodes. When the voltage is increased above the critical voltage, bubbles coalesce into a gas film around the tool-electrode. Sparking phenomena is observed in the film where electrical discharges happen between the tool-electrode and the surrounding electrolyte. Similar behavior can be obtained by inverting the polarity of the electrodes and by changing the electrolytes. Fig 2.1 explains the ECDM phenomenon [5].

    3.1 Photograph of the experimental set-up.

    A screw gauge micrometer is used as a screw feed mechanism which is employed to dip the tool in the electrolyte with controlled depth. A glass beaker is used as the electrolyte bath. The work-piece is 30mm×

    30mm with 3 mm thickness soda lime glass. Stirrer is used to maintain uniform temperature and circulation of electrolyte solution. Geared D.C. motor used for the rotation of Stirrer. At the cathode, sparking occurs at supply voltage of 40 V and above. Glass samples crack above 70 V supply

    voltage. Hence the working supply voltage range chosen is 40V to 60V. The concentration window was decided upon by performing many experiments to arrive at a permissible concentration range. It was observed that machining does not take place below 10% concentration of KOH. Hence 10% – 30% concentration ranges for KOH electrolyte. Level of electrolyte is maintained at 1 mm above the work piece surface in the ECDM cell. Experiments are conducted with Voltage, Electrolyte

    Concentration and Inter-electrode gap as the control variables. Copper is used for making the cathode of 1mm thick wire and anode of 3mm thick wire. Figure 3.1 shows the photograph of the experimental set-up. The depth of anode inside the electrolyte is also maintained at a fixed position.

    3.1. MACHINING CONDITIONS

    Following machining parameters are selected on the basis of performance characteristics,

    Table 3.1: Machining condition for analysis

    Table 3.3: Composition of Soda lime glass

    Element

    SiO2

    Na2O

    CaO

    Al2O3

    K2O

    SO3

    Wt.%

    74%

    13%

    10.5%

    1.3%

    0.3%

    0.2%

    3.3. Larger is best characteristics

    Data sequence for material removal rate, which is higher-the-better performance characteristics, is pre processed as per equation (3.1).

    = (( )) —— (eq. 3.1)

    Machining condition

    Specification

    Constant parameter

    Tool-electrode material

    Copper

    Auxiliary electrode material

    Copper

    Level of electrolyte

    1mm above the w/p

    Work-piece material

    Soda-lime Glass

    Machining time

    30 min

    Gap between tool- electrode and work-piece

    25 µm

    Variable parameter

    Applied voltage

    40V – 60V

    Inter-electrode gap

    20mm – 40mm

    Electrolyte concentration

    20% – 40%

    Machining condition

    Specification

    Constant parameter

    Tool-electrode material

    Copper

    Auxiliary electrode material

    Copper

    Level of electrolyte

    1mm above the w/p

    Work-piece material

    Soda-lime Glass

    Machining time

    30 min

    Gap between tool- electrode and work-piece

    25 µm

    Variable parameter

    Applied voltage

    40V – 60V

    Inter-electrode gap

    20mm – 40mm

    Electrolyte concentration

    20% – 40%

    3.2. SELECTION OF MACHINING PROCESS PARAMETERS

    Table 3.2 shows machining parameters and selected levels for experimental procedure

    Table 3.2: Process parameter and their levels

    Where, y is value of response variables and n is the number of observations in the experiments. Table shows the experimental results for MRR and the corresponding S/N ratio using eq. (3.1). Since the experimental design is orthogonal, it is possible to sort out the effect of each machining parameter at different levels.

    3.4. Measurement of Machining Performance

    Symbol

    Machining parameter

    Level 1

    Level 2

    Level 3

    A

    Applied voltage (V)

    40

    50

    60

    B

    Electrolyte concentration (%)

    10

    20

    30

    C

    Inter-electrode Gap (mm)

    20

    30

    40

    Symbol

    Machining parameter

    Level 1

    Level 2

    Level 3

    A

    Applied voltage (V)

    40

    50

    60

    B

    Electrolyte concentration (%)

    10

    20

    30

    C

    Inter-electrode Gap (mm)

    20

    30

    40

    Experiments were conducted as per designed experimental plan and the performance or responses were measured for each experimental run. The amount of metal removed (MR) was measured by taking difference in weight of the specimen before machining weight (W1) and after machining weight (W2) The MRR can be evaluated as;

    ( )

    Where, T-Machining time

    W1 -Before machining weight W2 – After machining weight

      1. EXPERIMENTAL PROCEDURE

        The design resulted in total of eighteen experiments, which are performed at 40V- 60V supply voltage, 10%-30% electrolyte concentration and 20mm-40mm inter-

        electrode gap as the values for the control variables. The responses measured are:

        • Material removal rate (MRR) Scheme of the experiments is as shown in Table 3.3

    Table 3.3: Experimental L9 orthogonal Array

    Expt. no

    Applied voltage

    (V)

    Electrolyte Concentration

    (%)

    Inter- electrode Gap (mm)

    For KOH

    For NaCl

    A

    B

    C

    MRR

    (mg/min)

    S/N Ratio

    MRR

    (mg/min)

    S/N Ratio

    1

    40

    10

    20

    0.9400

    -0.53744

    0.9312

    -0.61914

    2

    40

    20

    30

    1.0295

    0.25253

    1.0007

    0.00608

    3

    40

    30

    40

    1.3082

    2.33348

    1.1694

    1.35926

    4

    50

    10

    30

    1.1132

    0.93146

    1.1044

    0.86253

    5

    50

    20

    40

    1.0122

    0.10533

    1.0034

    0.02948

    6

    50

    30

    20

    2.1202

    6.52754

    2.0914

    6.40874

    7

    60

    10

    40

    1.4965

    3.50153

    1.4877

    3.45031

    8

    60

    20

    20

    2.3265

    7.33406

    2.1177

    6.51729

    9

    60

    30

    30

    2.0953

    6.42492

    2.0165

    6.09196

  4. RESULTS AND DISCUSSION

    1. Case I (Electrolyte solution – KOH, Work-piece Soda lime glass)

      Table 4.1: ANOVA for Material Removal Rate (KOH as electrolyte)

      Source

      DF

      Sum of squares

      Mean of squares

      F

      ratio

      P

      value

      Contribution

      Voltage(A)

      2

      39.538

      19.769

      8.96

      0.100

      51.77%

      Electrolyte concentration (B)

      2

      22.425

      11.212

      5.08

      0.164

      29.36%

      Inter-electrode gap (C)

      2

      9.997

      4.998

      2.27

      0.306

      13.08

      Error

      2

      4.412

      2.206

      5.79%

      Total

      8

      76.372

      100%

      S = 1.485 R-Sq = 94.2% R-Sq(adj) = 76.9%

      From the main effect plot refer Figure 4.1 it can be seen that, as the value of voltage increases (from 50 v to 60 v), the material removal rate increases for the KOH electrolyte solution. This is due to at higher voltage stronger spark is generated so melting starts at earlier, Hence, as the voltage increases the material removal rate

      is increases due to increasing spark energy. Secondarily, concentration gives high MRR. This is due to higher ionization and deionization which causes high erosion and thermal discharging. Whereas, this range concentration helps to continue the bubble generation and spark produced during the machining process.

      Graph4.1:Main Effects Plot for SN ratios (KOH)

      Graph4.2:Contribution of process parameters

      The regression analysis for MRR of Electrolyte solution using Minitab 15 software is shown in equation (4.1)

      MRR = – 0.580 + 0.0440 A + 0.0329 B – 0.0262 C ——- (4.1)

      The equation (4.1) shows that voltage is dominant factor affecting MRR.

      Fig (a)

      Fig (b)

      Fig(c)

      Graph 4.3. Effects of process variables on material removal rate (MRR). (a) Effects of Voltage on material removal for different Concentration, Inter-electrode Gap= 30mm. (b) Effects of Concentration on material removal for different inter-electrode gap, Voltage= 50v. (c) Effects of Inter-electrode gap on material removal for different Voltages, Concentration= 20%

      As KOH is strong base the ion mobility of this electrolyte much higher than the other electrolyte solution. Our work- piece is a soda lime glass containing the 74 % Silicate which is higher than the other constituent such as Na2O (13%) and K2O (0.3%) so these three constituent are more chemically reactive with the electrolyte solution Causing the higher material removal rate.

      4.2: Case: II (Electrolyte solution-NaCl, Work-piece Soda lime glass)

      Table 4.2: ANOVA for Material Removal Rate (NaCl as electrolyte)

      Source

      DF

      Sum of squares

      Mean of squares

      F

      ratio

      P

      value

      Contribution

      Voltage (A)

      2

      39.353

      19.677

      11.51

      0080

      55.45%

      Electrolyte concentration (B)

      2

      18.325

      9.162

      5.36

      0.157

      25.82%

      Inter-electrode gap (C)

      2

      9.873

      4.936

      2.89

      0.257

      13.91%

      Error

      2

      3.420

      1.710

      4.82%

      Total

      8

      70.970

      100%

      S =1.308 R-Sq =95.2% R-Sq(adj) = 80.7%

      Fig.4.4 Shows the MRR increases with increasing in voltage and electrolyte concentration also improved MRR is obtained with decreased inter-electrode gap. The increase in machining voltage causes a greater machining current in the electrode gap, thereby causing the enhancement of the MRR.

      Graph 4.4:Main Effects Plot for SN ratios

      Graph 4.5:Contribution of process parameters

      From the table (4.2) and fig. 4.5 as shown above following results are drawn for NaCl, are salt of strong acid and strong base hence slightly reaction takes place with soda lime glass .when NaOH and HCl are mixed together a reverse chemical reaction takes place which result in formation of NaCl and

      water separates out. When NaCl is mixed with water Na+ and Cl- ions are formed.

      The regression analysis for MRR of Electrolyte solution using Minitab 15 software is shown in equation (4.2)

      MRR = – 0.509 + 0.0420 A + 0.0292 B – 0.0247 C —– (4.2)

      The equation (4.2) shows that voltage is dominant factor affecting MRR.

      Fig (a)

      Fig (b)

      Fig(c)

      Graph 4.6: Effects of process variables on material removal rate (MRR). (a) Effects of Voltage on material removal for different Concentration, Inter-electrode Gap= 30mm. (b) Effects of Concentration on material removal for different inter-electrode gap, Voltage= 50v. (c) Effects of Inter- electrode gap on material removal for different Voltages, Concentration= 20%

      Above graph show interrelation of trends like MRR, voltage, concentration, gap. There is an increased trend in MRR observe at a voltage of 60v and concentration 30% while decrease in MRR is observed at an

      inter-electrode gap of 40mm. As compared to KOH material removal rate for NaCl is less.

  5. CONCLUSION

    Present work is performed for material removal in drilled holes by ECDM process. The experiments were performed by using Taguchi method of design of experiments. Analysis was carried out using Minitab15 software. The preliminary experiments were performed on Soda lime glass as work material using KOH, for only one response variables such as MRR. Three process parameters were selected such as applied voltage, Electrolyte concentration, and Inter electrode gap from the Final experiments, it is concluded that:

    • A new test rig is designed developed for ECDM for non conducting ceramic material.

    • Applied voltage is found to be most influential parameter for MRR.

    • Electrolyte concentration is a secondary fact of concern affecting the material removal rate.

    • From the design, development and analysis we conclude that for non conducting ceramic materials in this case soda lime glass KOH is the best electrolyte solution having much better removal rate than the other proposed electrolyte solutions.

  6. REFERENCES

  1. K.L. Bhondwe, Vinod Yadava, G. Kathiresan, Finite element prediction of material removal rate due to electro- chemical spark machining International Journal of Machine Tools & Manufacture, vol.46 (2006), pp 1699 1706.

  2. Jana D. Abou Ziki , Tohid Fatanat Didar

    ,Rolf Wuthrich, Micro-texturing channel surfaces on glass with spark

    assisted chemical engraving International Journal of Machine Tools & Manufacture vol.57 (2012), pp 66

    72.

  3. Chih-Ping Chenga, Kun- LingWub,n, Chao-ChuangMai a, Cheng-KuangYang c, Yu-Shan Hsu c, Biing- HwaYan, Study of gas film quality in electrochemical discharge machining International Journal of Machine Tools & Manufacture,vol.50 (2010), pp 689 697.

  4. V. K. Jain, P. Sreenivasa Rao, S. K. Choudhary, K. P. Rajurkar Experimental Investigations into Traveling Wire Electrochemical Spark Machining (TW-ECSM) of Composites Journal of Engineering for Industry, Vol.113 (1991), pp 75-84.

  5. R. Wuthricha, V. Fasciob, Machining of non-conducting materials using electrochemical discharge phenomenon An overview International Journal of Machine Tools & Manufacture, vol.45 (2005), pp 10951108.

  6. A Kulkarni R. Sharan G.K. Lal, Measurement of Temperature Transients in Electrochemical Discharge Machining Process. Indian Institute of Technology, Kanpur-208016, INDIA.

  7. V.K. Jain, S.K. Choudhury, K.M. Ramesh, On the machining of alumina and glass International Journal of Machine Tools & Manufacture, vol.42 (2002), pp 12691276.

  8. Sanjay K. Chak, P. Venkateswara Rao, Trepanning of Al2O3 by electro- chemical discharge machining (ECDM)process using abrasive electrode with pulsed DC supply International Journal of Machine Tools & Manufacture ,vol.47 (2007), pp 2061 2070.

  9. V.K. Jain, S. Adhikary On the mechanism of material removal in

    electrochemical spark machining of quartz under different polarity conditions journal of materials processing technology vol.200 (2008), pp 460470.

  10. Cheng-Kuang Yang a, Chih-Ping Cheng b, Chao-Chuang Mai b, A. Cheng Wang c, Jung-Chou Hung d, Biing-Hwa Yan a, Effect of surface roughness of tool electrode materials in ECDM performance International Journal of Machine Tools & Manufacture vol.50 (2010), pp 10881096.

  11. R Wuthrich, L A Hof, A Lal, K Fujisaki, H Bleuler, Ph Mandin and G Picard Physical principles and miniaturization of spark assisted chemical engraving (SACE) Journal of micromechanics and micro-engineering vol.15 (2005), pp 268S275.

  12. Cheng-Kuang Yang a, Kun-Ling Wub, Jung-Chou Hung c, Shin-Min Lee d, Jui- Che Lin a, Biing-Hwa Yan a, Enhancement of ECDM efficiency and accuracy by spherical tool electrode International Journal of Machine Tools & Manufacture vol.51 (2011), pp 528 535.

  13. B.R.Sarkar, B. Doloi, B. Bhattacharyya, Parametric analysis on electrochemical discharge machining of silicon nitride ceramics International Journal of advanced manufacturing technology, vol.28 (2006), pp873-881.

  14. B. Doloi, B. Bhattacharyya and S. K. Sorkhel, Electrochemical Discharge Machining of Non-Conducting Ceramics. Defense Science Journal, vol. 49 (August 1999), pp 331-338.

  15. Kulkarni, R. Sharan, G.K. Lal, An experimental study of discharge mechanism in electrochemical discharge machining. International Journal of Machine Tools & Manufacture, vol.42 (2002), pp11211127.

Leave a Reply