Contrast of Seismic Behavior of R.C.C. and Composite Columns in G+15 Storied Buildings with GFRG Infill

DOI : 10.17577/IJERTV6IS060302

Download Full-Text PDF Cite this Publication

Text Only Version

Contrast of Seismic Behavior of R.C.C. and Composite Columns in G+15 Storied Buildings with GFRG Infill

Athira K B

PG scholar, Department of Civil Engineering ,

Sree Buddha College of Engineering, Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam Technological University, Ayathil, Elavumthitta P.O, Pathanamthitta-689625

Abstract – Composite constructions are extremely accepted and widely used. The composite construction is favourable in resisting seismic forces because of reduced the seismic weight as compared to R.C.C building. The Better properties of steel and concrete combines in the composite building. Hence this study has been carried out to compares seismic evaluation of G+15 storey building of R.C.C column and composite column with and without GFRG infill located in seismic zone V. composite column of two types have been chosen fully and partially concrete encased composite column used for analysis. Column element in the structure is only taken as composite remain part will be made of conventional concrete for all structures. The equivalent single strut model is used for modeling of GFRG infill. The seismic behavior of the study frames is evaluated by Response Spectrum analysis by ETABS software.

Key Words: Composite columns, Overturning moment, Roof displacement, Seismic behavior, Storey drift etc.

  1. INTRODUCTION

    Most of the buildings are low rise in India. Due to rapid urbanization population increases, due to limited land in urban areas low rise building needs more spaces for construction so we use high rise building. Composite column constructions can be used for better and economical building for high rise structure. Composite construction of all structural elements takes more difficulty in design so here considered only column as composite element. Conventional concrete construction widely used due to its simple design and longevity. Because of huge dead load RCC structure are uneconomical.

    Glass Fiber Reinforced Gypsum infill (GFRG) panels are used increase the stiffness and strength of composite frame. These panels can also be used as structural member by cavities of panels partially filled or fully filled with reinforced concrete. To provide high rigidity modeling of infill panels by single diagonal strut method. this paper is to study the Seismic Analysis of Steel Concrete Composite System with RCC Structures with GFRG infill.

    Linda Ann Mathew Assistant Professor, Department of Civil Engineering,

    Sree Buddha College of Engineering, Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam Technological University, Ayathil, Elavumthitta P.O, Pathanamthitta-689625

  2. OBJECTIVES

    • To study performance of structure with R.C.C column, composite column with fully and partially concrete encased steel sections.

    • To determine the effective structure by comparing composite building with column fully and partially concrete encased steel sections

    Fig.1 Column fully and partially concrete encased steel sections

  3. GFRG PANEL

    Glass fiber reinforced gypsum, abbreviated as GFRG is the name given to a new building panel product, made of gypsum plaster, reinforced with glass fibers. GFRG is of particular relevance to India, where there is a tremendous need for cost- effective mass-scale affordable housing, and where gypsum is abundantly available as an industrial by-product waste. The product is not only eco-friendly or green, but also resistant to water and fire. GFRG panels are presently manufactured to a thickness of 124 mm, a length of 12m and a height of 3m. Although its main application is in the construction of walls, it can also be used in floor and roof slabs in combination with reinforced concrete.

    Fig.2 GFRG Panel

  4. METHODOLOGY

    Methodology employed is response spectrum method of analysis.

    1. Modelling of Building

      Here the study is carried out for the behaviour of G+15, with R.C.C column and composite column with fully and partially concrete encased steel sections. Floor height provided as 3m. Three models including G+15 with GFRG infill are created. Properties are different for different models. The modeling of buildings was created in ETABS software.

    2. Building Plan and Dimensions

    A building of plan 20m x 20 m(i.e. 400m2) is considered with G+15 storey in zone V. A medium soil stratum is considered at the location.

    Fig.3 plan of building

    Table 1

    Plan dimension

    20 × 20 m

    Height of each floor

    3 m

    Type of structure

    Ordinary Moment Resisting Frame

    Grade of steel

    Fe 415

    Grade of concrete

    M30

    Density of R.C.C

    25kN/m3

    Dimension of R.C.C column

    450 × 550 mm

    Dimension of R.C.C beam

    350 × 450 mm

    Column size for fully concrete encased steel sections

    400 mm × 400 mm, ISHB 300

    Column size for partially concrete encased steel sections

    400 mm × 250 mm, ISHB 400

    Details and dimension of the building models

    Table 2 Properties of GFRG Panel

    Unit weight of GFRG panel

    0.433 kN/m2

    Thermal expansion coefficient

    12 × 10-6mm/mm/

    Modulus of Elasticity

    7500 MPa

    Fig.4 3D view of R.C.C building

    Fig.5 3D view of composite building with fully concrete encased columns

    Fig.6 3D view of composite building with partially concrete encased columns

    MAXIMUM DISPLACEMENT

    40

    39.5

    39

    38.5

    38

    37.5

    37

    36.5

    36

    35.5

    M1 M2 M3

  5. COMPARISON OF RESULTS

    MAXIMUM DISPLACEMENT(mm)

    After analysing the results obtained then it will be compared and find the seismic performance of the building with infill.

    The building models and their abbreviations are given below:

    1. R.C.C M1

    2. Composite Fully Encases Steel Section – M2

    3. Composite Partially Encases Steel Section – M3

      1. Base Shear

    Table 3

    R.C.C

    (M1)

    COMPOSITE FULLY ENCASES STEEL SECTION (M2)

    COMPOSITE PARTIALLY ENCASES STEEL SECTION (M3)

    7389.79

    6638.73

    6261.51

    Maximum Base Shear

    Fig.8 Comparison of Maximum Lateral Displacements.

    For composite fully and partially encases steel section, the base shear is reduced up to 10 % when compared to that of R.C.C.

    1. Storey Drift

      R.C.C

      (M1)

      COMPOSITE FULLY ENCASES STEEL SECTION (M2)

      COMPOSITE PARTIALY ENCASES STEEL SECTION (M3)

      0.001513

      0.00322

      0.00534

      Table 5 Maximum Storey Drift

      BASE SHEAR

      7600

      7400

      7200

      7000

      6800

      6600

      6400

      6200

      6000

      5800

      5600

      M1

      M2

      M3

      BASE SHEAR (kN)

      Fig.7 Comparison of Base Shear

      For R.C.C, the minimum storey drift. And for fully and partially composite encases steel section, is within the limit and lessthan with infill model. Partially encases steel section lateral displacement is increased up to 40% compared with composite fully encases steel section

      STORY DRIFT

      0.006

      0.005

      0.004

      0.003

      0.002

      0.001

      0

      STORY DRIFT (mm)

      1. Displacement

    Table 4

    Maximum Lateral displacements

    R.C.C

    (M1)

    COMPOSITE FULLY ENCASES STEEL SECTION (M2)

    COMPOSITE PARTIALY ENCASES STEEL SECTION (M3)

    36.99

    37.11

    39.59

    M1

    M2

    M3

    For composite fully encases steel section and R.C.C the Lateral displacements is nearly same. partially encases steel section lateral displacement is increased up to 6% compared with composite fully encases steel section.

    Fig.9 Comparison of Maximum Storey Drift

    A. Stiffness

    Table 6 Stiffness

    ACKNOWLEDGEMENT

    R.C.C

    (M1)

    COMPOSITE FULLY ENCASES STEEL SECTION (M2)

    COMPOSITE PARTIALY ENCASES STEEL SECTION (M3)

    16477958

    7026036

    6883996

    I am thankful to my guide, Asst. Professor, Linda Ann Mathew in Civil Engineering Department for her constant encouragement and able guidance. Also I thank my parents, friends etc. for their continuous support in making this work complete.

    REFERENCES

    STIFFNESS

    20000000

    15000000

    10000000

    5000000

    0

    M1

    M2

    M3

    STIFFNESS (N/m)

    Fig.10 Comparison of Stiffness

    From Fig. 10 it is clear that storey stiffness is higher in R.C.C building with infill. The two composite buildings are same stiffness.

  6. CONCLUSIONS

Analytical study has been conducted to understand the behavior of R.C.C and concrete encased columns in a structure. ETABS software is used to carry out the analysis. Comparison of conventional and composite design has done. And the following conclusion has been drawn from it.

  • It is observed that the base shear is about 10% to 15% difference in both composite columns structure when compared to the structure with RC columns. Hence, conventional building can be considered superior than the composite building in terms of base shear.

  • Storey drifts are higher that is 40% in the case of composite building. And drift for all building is within the limits as per IS code.

  • The storey drift is maximum at second floor which may cause more damage to the floors above it, particularly in case of composite structure. But in conventional building, not much drift are observed in between successive floors, which makes it relatively safe.

  • Comparing composite building with column fully and partially concrete encased steel sections, fully concrete encased steel sections column has better performance.

  1. D. R. Panchal, S.C. Patodi, Response of A steel-concrete Composite Building Vis-a-vis An R.C.C. Building under Seismic forces, NBM & CW Journal, August 2010.

  2. D. R. Panchal, P. M. Marathe, Comparative study of R.C.C., Steel and Composite building, Institute Of Technology, Nirma University, Ahmedabad-382481, December, 2011, pp. 08-10.

  3. Shweta A. Wagh, Dr. U. P. Waghe, Comparative Study of

    R.C.C and Steel Concrete Composite Structures, Int. Journal of Engineering Research and Applications, ISSN : 2248-9622,

    Vol. 4, Issue 4( Version 1), April 2014, pp.369-376

  4. Anish N. Shah 1, Dr. P.S. Pajgade, Comparision of R.C.C. And Comosite Multistoried Buildings International Journal of Engineering Research and Applications (IJERA) ISSN: 2248- 9622 Vol. 3, Issue 2, March -April 2013, pp.534-539

  5. Sattainathan. A and Nagarajan. N, Comparitive study on the behavior of R.C.C, Steel & Composite Structures (B+G+20 storeys), International Journal on Applications in Civil and Enviornmental Engineering Volume 1: Issue 3: March 2015, pp 21-26.

  6. Anamika Tedia1 and Dr. Savita Maru, Cost, Analysis and Design of Steel-Concrete Composite Structure Rcc Structure IOSR Journal of Mechanical and Civil Engineering e-ISSN: 2278-1684,p-ISSN: 2320-334X, Volume 11, Issue 1 Ver. II (Jan. 2014), PP 54-59

  7. Wu YF, The effect of longitudinal reinforcement on the cyclic behavior of glass fiber reinforced gypsum wall panels: tests, Elsevier eng struct 2004:26(11) pp: 1633-46.

  8. Wu YF, The structural behavior and design methodology for a new building system consisting of glass fiber reinforced gypsum panels, Elsevier, construction and building materials 2009:23 pp: 2905-13.

  9. Liu K, Wu YF and Jiang XL, Shear strength of concrete filled glass fiber reinforced gypsum wall walls, RILEM, mater struct 2008:41(4) pp: 649-62.

  10. Menon D, Rapid affordable mass housing glass fiber reinforced gypsum (GFRG) panels, IJSER Volume: 5 Issue: 7 2014: ISSN 2229-5518.

  11. Athulya R Prasad and NamithaChandran (2016) Static analysis of GFRG and conventional multistoried building using ETABS, International Journal of Science Technology & Engineering , Volume 2 , Issue 12, 563-566.

Leave a Reply