Design, Fabrication and Testing of Biogas Stove for ‘Areke’ Distillation:The case of Arsi Negele, Ethiopia, Targeting Reduction of Fuel-Wood Dependence

DOI : 10.17577/IJERTV5IS030410

Download Full-Text PDF Cite this Publication

Text Only Version

Design, Fabrication and Testing of Biogas Stove for ‘Areke’ Distillation:The case of Arsi Negele, Ethiopia, Targeting Reduction of Fuel-Wood Dependence

Shewangizaw W. Demissie School of Mechanical Engineering Jimma University

Jimma, Oromia ET, Ethiopia

Venkata A.Ramayya

School of Mechanical Engineering Jimma University

Jimma, Oromia ET, Ethiopia

Derese T. Nega Department of Physics Jimma University

Jimma, Oromia ET, Ethiopia

Abstract In Ethiopia, in addition to the already existing burden on natural resource imposed by the use of traditional biomass for cooking, the processing and production of alcoholic beverages such as local liquor (Areke), local beer (Tela), Korefe, Borde and others place further threat on the forest. Research on potential assessment of biogas to replace the fuel wood consumption has revealed a promising result of biomass dependence reduction. This study showed that if sustainable biogas energy development is implemented, the dependency on fuel wood can be reduced by 27.7% by reducing 32, 763.70 tons of GHGs emission annually in Arsi Negele alone. Therefore, through this study analytically designing the biogas stove for minimum gas consumption and high efficiency, fabrication and experimental testing is done. Additionally the economic projection of biogas utilization in Areke distillation is evaluated and found to be economically feasible with a payback period of a little over three years. The overall efficiency of the stove evaluated through Water Boiling Test (WBT) is found to be 54.8% , 43.6% at higher flame intensity and relatively lower flame intensity respectively. The stove showed a remarkable reduction in time taken for distilling a pot of distill and which is nearly half of the time it took to distill a pot of distilland using wood. The new stove consumes only 0.994 m3 of biogas while the biogas stove tested before which is ordinary biogas stove for general cooking purpose consumes

    1. m3 to distill a pot of distilland. Even though the initial investments are high, with the conducive environment available for biogas production at Arsi Negele, using biogas for Areke distillation without any doubt can be a viable option for eco- friendly and economically feasible production of traditional Areke. Therefore, any concerned government and non- government body should act in promoting either by piloting or partly funding the installation while putting the sense of ownership in the mind of the users.

      Keywords Areke distillation, Biogas stove, eco-friendly, deforestation, overall efficiency

      1. INTRODUCTION

        Widely practiced traditional Areke distillation all over the country in Ethiopia is imposing socio-economic and environmental impact. As a result of these practice, even protected forests are stripped and deforestation is escalating rapidly because Areke production is currently powered by fuel wood from nearby forest. For Ethiopia, given resource potential, biogas is one of the promising clean energy for

        households. The sole technology for biogas production in Ethiopia so far is anaerobic digestion/fermentation that based on animal residue which Ethiopia is endowed with huge potential.

        According to Ethiopias Climate Resilience Green Economy Strategy, replacing open fire stoves with stoves that need only half as much fuel wood or stoves that use other fuels holds an estimated 20% of Ethiopias total potential for emission reduction. On top of greenhouse gas emissions from deforestation it would have an impact by;

        • Increasing rural household income by 10%.

        • Creating many more jobs in making stoves.

        • Reducing severe health risks from smoke inhalation (black carbon)

        • Also decrease hours spent on gathering fuel wood (typically by women, Girls and children, often in risky areas).

        Thus, this work depicts the feasibility of using Areke distilling stove through the use of biogas as a feed stock for reduction of fuel wood dependence of Areke distillation.

      2. DESIGN OF BIOGAS STOVE

        1. Injector

          An injector needs to be carefully designed and positioned in order to control the amount of gas and air used by a burner. The size and shape of the injector orifice control the gas flow rate and hence heat input for a given gas composition and supply pressure [1].

        2. Discharge from an orifice

        In physical terms, an injector uses to convert potential energy from high pressure gas supply in to the kinetic energy of an emerging gas jet. Mathematically, therefore, by conservation of energy and assuming no losses at the nozzle, we have (per unit mass):

        2 j

        2 j

        1 v2 = gh Or V = A 2gh (1)

        Where:

        – Volumetric gas flow rate from the orifice (m3 s-1) Aj – jet area (m2)

        g -acceleration due to gravity

        h -column of gas required to exert gas pressure at the orifice

        Gauge pressure is given as:

        p = hgg (2)

        Where; g = density of biogas (1.15kg/m3) From equation 1 and 2

        lean, with a small excess air, to avoid the danger of the flame becoming rich [3].

        In partially aerated burners, air is mixed with the gas before it is burnt. The amount of primary air added to the gas before the flame, varies depending on the design

        s

        s

        Q = 0.046101Ajp

        Where: Q = gas flow rate (m3 h-1) Aj = area of orifice (mm2)

        p= gas pressure before orifice (10mbar) s = specific gravity of biogas gas (0.94)

        (3)

        of burner, but is usually around 50% of the total air requirement.

        D. Aerated flame

        As gas comes out through injector, primary air is entrained into the stream and is mixed in the mixing tube with the gas

        Relative density (specific gravity) of methane and Carbon

        dioxide (with air density=1 kg/m3) is 0.554 kg/m3 and 1.519 kg/m3 respectively [2]. Volumetric content of biogas is 60% methane and 40% carbon dioxide; based on the volumetric content specific gravity of biogas expressed as:

        s = (0.554 kg/m3 *60%) + (1.519 kg/m3 *40%) = 0.94 kg/m3 In practice, the flow of gas after orifice is less than before

        orifice because of frictional losses and the vena-contract effect. It is usual to represent these two terms as a coefficient of discharge, CD such that:

        before it comes out of the burner port. The unburned gas is heated up in an inner cone and starts burning at the flame front. The cone shape is a result of laminar flow in a cylindrical mixing tube, the mixture at the center of the tube is moving at a higher velocity than that at the outside. The main combustion zone is where the gas burns in the primary air and generates the heat in the flame. The Outer mantle of the flame is where combustion is completed with the aid of the secondary air that is drawn into the flame from the sides.

        The combustion products (carbon dioxide and steam) are at a high temperature, so rise vertically away from the flame,

        s

        s

        Q = 0.046101CDAjp

        (4)

        transferring heat to the air close to the top of the flame. It is this air moving vertically away that draws in the cooler

        CD = coefficient of discharge for the orifice is taken 0.94 from [2]

        C. Biogas combustion

        The combustion of gas involves mixing of air with fuel gas, adding heat in the form of a pilot and burning the resultant air-gas mixture. The chemical reaction of combustion of biogas (containing 60 % methane and 40 % carbon dioxide) and air (oxygen and nitrogen) mixture is shown below:

        0.6CH4 + 0.4CO2 + 1.2O2 + 4.5N2 CO2 + 1.2 H2O + 4.5N2

        + Eergy (5)

        Thus, one volume of biogas requires 5.7 volumes of air or the stoichiometric requirement is1/ (1+5.7) = 0.149, i.e.,

        14.9 % volume of biogas is required in air.

        Characteristics of biogas important from the viewpoint of designing an efficient stove or a lamp are mentioned in table I.

        TABLE I: PROPERTIES OF BIOGAS RELEVANT FOR DESIGNING A STOVE OR A

        secondary air to the base of the flame. The size of the inner cone depends on the primary aeration. A high proportion of primary air makes the flame much smaller and concentrated, giving higher flame temperatures [3].

        1. Air entrainment

          The mechanism of air entrainment has been studied experimentally and theoretically for many years, and is of vital interest to the domestic aerated burner designers because the quantity of primary air taken up has a considerable effect on burner port design requirements, flame stability, shape and temperature, and, ultimately, the design of the combustion chamber itself.

          The gas emerging from the injector enters the end of the mixing tube in a region called the throat. The throat has a much larger diameter than the injector, so the velocity of the gas stream is much reduced.

          The velocity of the gas in the orifice is given by:

          LAMP (SOURCE: D.GUPTA 2009)

          v = Q 3.6×103Aj

          ms1, with Q in m3h-1 and Aj in (mm)2 (6)

          j

          j

          Property

          Value

          Methane and carbon dioxide content

          60 % and 40 %

          Calorific value

          22 MJ/m3

          Specific gravity

          0.940

          Density

          1.2kg/m3

          Flame speed factor

          11.1

          Air requirement for combustion

          5.7 m3/m3

          Combustion speed

          40 cm/sec.

          Inflammability in air

          6-25 %

          Property

          Value

          Methane and carbon dioxide content

          60 % and 40 %

          Calorific value

          22 MJ/m3

          Specific gravity

          0.940

          Density

          1.2kg/m3

          Flame speed factor

          11.1

          Air requirement for combustion

          5.7 m3/m3

          Combustion speed

          40 cm/sec.

          Inflammability in air

          6-25 %

          Velocity reduction in the throat is expressed as:

          j

          j

          t

          t

          v = v Aj

          At

          (7)

          Ignoring the vena contractor effect and friction loss the gas pressure just after the nozzle then becomes:

          P = P vj2 [1 (dj)4] (8)

          t j 2g dt

          Biogas will burn over a narrow range of mixtures from approximately 9% to 17% of biogas in air. If the flame is `too rich', i.e., has too much fuel, then it will burn badly and incompletely, giving carbon monoxide (which is poisonous) and soot (carbon particles). Burners are usually run slightly

          The value of Pj is around atmospheric pressure as the throat is open to the air. This pressure drop is sufficient to draw primary air by the air inlet parts to mix with the gas in the mixing tube [3].

          The primary aeration depends on the entrainment ratio (r) which is determined by the area of the throat and the injector.

          Where: Ap

          (the total burner port area in m2)= np

          dp2 4

          (14)

        2. Throat size

        The flow rate of the mixture in the throat Qm is the sum of flow rate of the gas and the entrained air.

        np – Number of ports

        – Diameter of each port in m

      3. METHODOLOGY AND MATERIALS

        =

        (1 + ) (9)

        1. Analytically determining power required

          Considering the efficiency of the traditional stove which is

          Where r is the entrained air to gas volume ratio, then: =

          The pressure drop due to the flow of the mixture down the mixing tube should be checked, by first calculating the Reynolds number.

          not greater than 10% [4] the power required for the process can be determined using the general equation of efficiency. With a calorific value (CV) of wood at 19.45 MJ/Kg [5] and specific fuel consumption of the process 1.007Kg of wood per Kg of distilland [6]. As the experimental test result on the study

          Re = mdtvt = 4mQm

          (10)

          conducted by Girma Gezahagn in order to distill in average

          mdt

          Where and are the density and viscosity of the mixture specified as follows:

          = 1.15/3 And

          = 1.71 × 105 At a temperature of 30oC

          The pressure drop is given by:

          45.033Kg of distilland it took about 760min or 12.67hours [6].

          To determining the power required could be first calculating the rate at which firewood is being burned as (1.007*45.033)/12.67 =3.58Kg/hr then using the same values of efficiency and calorific value of wood we can come up with the power.

          P = f v 2 lm = f

          16Qm2 l

          (11)

          Efficiency = Power out put

          (15)

          2 m t dt

          Where:

          2 m 2dt5 m

          0.316

          Power input

          Efficiency of traditional stove = Power out put

          (16)

          = , when < 2000 and =

          64

          3

          4

          when > 2000

          (12)

          CV of wood×mass of wood/hr

          Power out put required = 1.547KW

          The pressure drop should be much less than the driving pressure. Most burners are designed to have a throat that gives aeration greater than optimum, with a device for restricting the air flow, so the optimum aeration can be set for a given situation.

          1. Mixing tube

            The mixing tube and diffuser as one unit and obtained by experiment the effect on air entrainment of mixing tube length

            Therefore, Areke distillation process requires or took power of 1.547KW.

            B.Determination of Biogas required

            In determining the biogas flow rate to meet the power input required for the process knowing the power required of the process being 1.547KW, calorific value of biogas 22MJ/m3[7] and setting optimum biogas stove efficiency of 50% can be calculated as follows;

            both downstream and upstream of the throat from practical result the distance from the throat entrance to the injector should be about 2 to 2.5 times the throat diameter, and that

            Efficiency of biogas stove = Power out put

            CV of biogas×Qbiogas

            Qbiogas = 0.504m3/hr

            (17)

            mixing tube length should be about 10 to 12 throat diameters [1]

          2. Burner ports

          The big advantage of a gas burner is that the heat can be directed to where it is needed, by designing the burner properly.

          When a biogas/air mixture has ignited, the flame front produced propagates through the remaining unburnt gases at a

          In other way considering the efficiency of the traditional stove which is not greater than 10% [4] the energy required for the process can be determined using the general equation of efficiency. With a calorific value (CV) of wood at 19.45 MJ/Kg and specific fuel consumption of the process 1.007 Kg of wood per Kg of food cooked [6]. The energy required to cook one kilogram of food will be:

          Efficiency of traditional stove = energy input required / (CV of wood * mass of wood/mass of food)

          rate dependent on the mixture composition, pressure and temperature. The burning velocity is a fundamental property of the mixture and is linked to the overall chemical reaction

          Efficiency of tradi. stove =

          ×

          Energy out put = 1.567

          (18)

          rate in the flame. Burning velocity is defined as the velocity normal to the flame front, relative o the unburnt gas, at which an infinite one dimensional flame propagates through the unburnt gas mixture. Biogas has a stoichiometric flame speed of only 0.25 m/s burning velocity [3]

          The energy required to cook one kilogram of food is found to be 1.567 MJ with this result we can determine the volume of gas required as an input with an optimum biogas stove efficiency of 50% [7] to achieve the energy required for the process with a Wobe number of the biogas to be 22MJ/m3[7]as follows.

          The mixing supply velocity is given by [3]:

          Efficiency of biogas stove = (Energy out put)(kg of distilland)

          (19)

          p

          p

          v = Qm Ap

          0.25ms1 (13)

          (CV of biogas)×Volume of biogas

          Volume of biogas = 0.142 m3kg of food cooked

          From the experimental test result on the study conducted by Girma Gezahagn in order to distill in average 45.033Kg of distilland it took about 760 min or 12.67 hours[6]the amount of distilland distilled per hour will be 45.033/12.67 = 3.554 Kg of distilland / hour. Therefore from this it is simple to calculate the gas required per hour as 0.142 * 3.554 = 0.504 m3/hr.

          1. Hypothesess

            From the results of calculations made above and information gathered from literatures the potential of biogas in reducing firewood dependence of Areke production can be evaluated. Biogas flow rate required for the process of Areke production at 0.504m3/hr and biogas production potential of Areke distillers at 3m3 the amount of time the biogas can serve the Areke production is 3/0.504 =5.95hours. However, the traditional stove burns 5.95 * 3.58 = 21.3Kg of fire wood to perform the same process. Therefore, this 21.3Kg of firewood that could have been burned can be replaced by the biogas and it accounts for 27.7% of the total 76.98Kg/day of firewood consumption.

          2. Analytical Design Calculations of stove parameters

            1. Sizing injector or orifice jet

              The ejector or orifice area was calculated by using (1)

              Throat diameter dt is calculated using Prigs formula including orifice diameter as follows [3]

              t j

              t j

              d = ( r + 1) d = 8.16mm (21)

              s

              However, it is better to use the stoichiometric value of primary

              air of 5.7 directly rather than using r = 2.85 to get better aeration and control using primary air flow adjuster. So, the better diameter of throat will be [3] dt 14.2mm.Then the throat area becomes 158.4mm2 or 1.58*10-4m2 The primary

              air inlet port must have an area similar to that of the throat [3].

              The gas pressure in the throat can be calculated using (8),Pt = 99910Pasical. The value of Pj is 105Pa as the throat is open to the air. This pressure drop is sufficient to draw primary air by the air inlet parts to mix with the gas in the mixing tube [3].

              Calculating the Reynolds number should be used to check the pressure drop due to the flow of biogas and air mixture in the mixing tube using (10,) is Re = 3097.5. Thus, Re < 2000, so the friction loss is calculated using (12,) is f = 0.04236 and pressure drop P could be calculated using (11) is P =

              2.79 Pasical. So that, the pressure drop is much lower than the driving pressure/pressure in the throat.

              iii. Burner port design

              o

              o

              d = Q 0.0361×CD

              × 4 s = 2.16mm (20)

              P

              Biogas has a stoichiometric flame speed of only 0.25 m/s burning velocity [3]. The mixture supply velocity (vp) using

              Where: Q (gas flow rate) = 0.504m3/hr

              The area of orifice jet is determined as:

              (13) is vp = 0.25ms1.

              The total burner port area will be chosen as:

              d2

              6 2

              A > Qm >> 0.0021m2 (22)

              Aj = 4 = 3.7 × 10 m

              p vp

              The velocity of the \s in the orifice jet is:

              A

              A

              j

              j

              v = Qbiogas = 38ms1

              j

              Fulford (1996) and Itodo (2007) in their study used 5mm and 2.5mm diameter holes respectively. However, a problem of flame lift was recorded at a diameter less than 2.5 mm[8]. Using 3 mm port diameter to minimize the problem of flame lift, the total number of required ports will be:

              n =

              n =

              4Ap

              p dp2

              == 308 ports

              Using flame stablization, litraturebsuggested it is possible to reduce this number of burner ports, by up to 1/5, so 62 holes are suficient [3].

              s

              s

              Fig. 1. Graph of: Q = 0.046101CDdj2p

            2. Determining the throat size

              From the composition of biogas, the stoichiometric air requirement is 5.7, then the entrainment ratio (r) is r = 5.72 = 2.85. The flow rate of the biogas and air mixture at

              optimum aeration is given by (9); Qm == 5.25 × 104m3s1.

              Using 62 holes, with 5mm gaps between holes, arranged in a circular pattern, gives a total circumference of 62*(3+5) = 496mm. The hole centers are then placed around a circle of diametre 496mm = D D 157mm.

          3. Fabrication of stove

            The biogas stove for Areke distillation was fabricated based on the values of stove parameters obtained on the analytical design calculation made in earlier sections of this report. The very important parameters that are taken in to consideration during the fabrication process of the stove are listed below.

            1. Injector or orifice diameter

            2. Throat diameter

            3. Mixing tube length

            4. Primary air inlet area

            5. Burning port: number of holes and their diameter

            6. Burner manifold diameter and height

            The parameters listed above are mainly linked to the burner part of the stove. But other more considerations were also taken into consideration during the fabrication of the stove frame. Considerations such as the gap between the burner top and the vessel are made to be adjustable through a mechanism that helps to perform the task. The stove is also equipped with an access to control the primary air which is a sliding type. The figure bellows are detailed fabrication drawing:

            Fig. 2. Stove Frame 3D drawing

          4. Experimental test

            In order to evaluate the performance of the stove and to check whether or not it will serve its desired purpose two types of tests have been conducted which are water heating test to easily or simply calculate how much of the heat of the combustion goes to the water being boiled to evaluate the thermal efficiency of the stove and actual function test (Controlled Cooking Test) means test run while Areke is actually being distilled by using the newly constructed biogas stove.

            Fig. 5. Experimental setup

            1. Water boiling test

              Due to the major limitation of getting enough time and biogas to make the through waterboiling test what has been done in this experiment is bringing a specified mass of water from its initial temperature to its boiling point and check how much gas was consumed. Which means from complete water boiling test performing only the High power phase to easily or simply calculate how much of the heat of the combustion goes to the water being boiled. And from the measurements obtained the simple thermal efficiency of the stove was calculated using the following equation[9].

              Efficiency

              Where:

              overall

              Mw × CPw(Tb Ti) + Mv × Cpv(Tb Ti)

              = Vbg × CVbg

              Fig. 3. Biogas burner 3D drawing

              Fig. 4. The photograph of assembled stove

              Mw mass of water boiled

              Cpw Specific heat capacity of water = 4.2KJ/Kg.0C

              Cpv Specific heat capacity of Stainless steel = 0.5 KJ/Kg.K CVbg Calorific value of fuel (biogas) = 22 MJ/m3

              Vbg Volume of biogas consumed

              Mv Mass of the vessel

              Ti Initial temperature of water

              Tb Boiling temperature of water at Jimma approximated as =

              (100 Altitude) where Jimma altitude is 1700 to 1800m

              300

              above sea level.

              In the complete form of the above equation the mass of steam evaporated and latent heat of the boiling water is not considered due to the abovementioned limitations since the test was made until the water reaches its boiling point.

              With above consideration the performance of the biogas stove was tested under the following conditions:

              1. Efficiency and boiling rate at various operating pressure

              2. Efficiency and boiling rate at various volume of water

              3. Efficiency and boiling rate at various flame intensity and volume of water

              4. Efficiency and boiling rate of the stove with and without lead vessel

            2. Controlled Cooking Test for Areke Distillation

            To conduct this test first I was expected to contact an experienced traditional Areke distiller. But it was not an easy task to find one. Because most of them has stopped Areke distilling but still they are selling Areke by bringing it from Gojam. For these reason I was having hard time of finding someone who is currently distilling Areke. But one lady was willing to do it if I provide the necessary supplies and I complied.

            In the process of controlled cooking test the weight of the pot, the weight of the distilland cooked, the amount of Areke distilled and the time taken to complete has been measured. The operating pressure and the amount of biogas consumed were computed from the design considerations. Three distillations were performed during the experimental test.

          5. Materials

          In this study, even though there were a lot of limitations, several materials have been utilized to make it conclusive as much as possible. To mention the materials used biogas digester from Jimma Degitu Hotel, 21 Kg cylinder gas to replace the biogas digester, the newly constructed biogas stove, pressure gauge, thermometers to read temperatures, stop watch to count time, weighing balance to measure the weight of the distilland, the pot and vessels used in the experiment, the entire setup of traditional Areke distillation and various size stainless steel vessels.

      4. RESULT AND DISCUSSION

        In this section the results obtained from the analytical design and experiment presented and discussed against literatures and

        1. Water Boiling Test

          In this water boiling test experiment, the maximum overall efficiency obtained was 54.8 % at higher fire intensity while 8 litters of water were being boiled and 43.6 % at relatively lower fire intensity while 10 litters of water were being boiled.

          Fig. 6. During water boiling test

          Water boiling rate at different operating pressure with water volume of 2.4 litter and the weight of the vessel 1.5kg was also conducted. The result obtained shows that as the operating pressure drops , the boiling rate were also drops similarly. The result is graphically presented below in Fig. 7,.

          WBT @ different pressure

          100

          Water temp

          Water temp

          80

          60

          40

          20

          0

          0 1 2 3 4 5 6 7 8 9 10111213141516171819

          previous studies. Since the results of the analytical design 9 mbar

          calculations are already provided in the previous section

          Tim8em(mbainr ) 4 mbar

          here only the summery is presented. But the results of the experiment is elaborated in detail in this section and discussed.

          1. Results of analytical design

            The stove is constructed with the fabrication values listed in the table II and tested if it gives the result it is required from it for the specific purpose it is designed for.

            TABLE II: THE RESULTS OF THE ANALYTICAL DESIGN CALCULATION ARE PRESENTED BELOW AS FOLLOWS:

            S.No.

            Parameters

            Results

            Fabrication values

            1.

            Design biogas flow rate

            0.504 m3/hr

            2.

            Design Injector diameter

            2.16 mm

            2.5 mm taken for stove fabrication

            3.

            Throat diameter

            14.67mm

            17 mm

            4.

            MIXING tube length

            22cm

            210 mm

            5.

            Burner port diameter

            3mm

            3 mm

            6.

            Burner manifold diameter

            127.3mm

            130 mm

            7.

            Number of burner ports

            62

            62

            8.

            Primary air inlet area

            191.6mm2

            191.6 mm2

          2. Results of Experimental test

          The experimental tests which are the water boiling and controlled cooking tests conducted as it was stated in the methodology of the study are presented below.

          Fig. 7. Boiling rate at different pressure

          TABLE III: DATA OF WBT AT VARIOUS OPERATING PRESSURE AND SAME VOLUME OF WATER

          Time

          (Min)

          Test one

          Time

          (min)

          Test two

          Time

          (min)

          Test Three

          milibar

          oC

          milibar

          oC

          milibar

          oC

          0

          9

          22

          0

          8

          22

          0

          4

          22.8

          1

          9

          29.1

          1

          8

          28.5

          1

          4

          27

          2

          9

          36.1

          2

          8

          34.7

          2

          4

          32.9

          3

          9

          43.2

          3

          8

          40.9

          3

          4

          35.5

          4

          9

          50.4

          4

          8

          47.4

          4

          4

          42.2

          5

          9

          57.6

          5

          8

          53.8

          5

          4

          46.4

          6

          9

          65

          6

          8

          60.1

          6

          4

          50.1

          7

          9

          72.4

          7

          8

          66.5

          7

          4

          55

          8

          9

          79.7

          8

          8

          72.8

          8

          4

          61.1

          9

          9

          86.5

          9

          8

          79.3

          9

          4

          64.8

          10

          9

          91.9

          10

          8

          85.9

          10

          4

          70.8

          10:30

          9

          94.4

          11

          8

          92.1

          11

          4

          75.2

          11:18

          8

          94.3

          12

          4

          79.4

          13

          4

          84.5

          14

          2

          87.3

          15

          2

          89.6

          16

          2

          91.9

          17

          2

          94.1

          17:10

          2

          94.5

          Efficiency @ constant volume & different pressure

          Table IV above shows the result of the test conducted for vitiation of heating rate for small rise in water volume being boiled at constant operating biogas pressure and the variation of heating rate is found to be small as compared to the heating variation at relatively bigger volume change of water boiled shown in Fig. 10,).

          43.5

          43

          Efficiency (%)

          Efficiency (%)

          42.5

          42

          41.5

          41

          40.5

          40

          39.5

          39

          38.5

          4 6 8 10

          Pressure (mbar)

          100

          Temperature

          Temperature

          80

          60

          40

          20

          0

          Boiling rate @ higher water volume

          0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

          Fig. 8. Efficiency at different pressure

          4 Litter

          Time (min) 6 Litter

          8 Litter

          The evaluation of water heating rate while the vessel is losed and opened also conducted in this experiment and the result obtained indicated that the rate of water heating is extended when the vessel is opened. The fig. 9, below shows the variation of water heating rate with the vessel closed and open.

          Water boiling rate with and without lead

          10 Litter 12 Litters

          Figure 10. Boiling rate at higher water volume variation

          The combined result presented in Fig. 11, shows the difference in the variation of heating rate for both small and larger water volume change.

          100

          Water temperature

          Water temperature

          80

          60

          With lead

          100

          90

          Water Temperature

          Water Temperature

          80

          70

          60

          Boiling rate @ all volume

          40 Without lead

          20

          0

          0 2 4 6 8 10 12 14

          Time (min)

          Fig. 9. Water boiling rate with the vessel closed and open

          50

          40

          30

          20

          10

          0

          0 1 2 3 4 5 6 7 8 9

          Time (min)

          Time

          Volume of Water (Liters)

          1Lit

          1Lit

          2 Lit

          2Lit

          1Lit

          Temperature rise of water (0C)

          0

          23.1

          24

          24.1

          23.4

          0

          1

          32

          33.2

          28

          28

          1

          2

          39.9

          42

          35.7

          34.5

          2

          3

          48

          52

          42

          42

          3

          4

          55.8

          61.9

          52.3

          49.8

          4

          5

          65.4

          70.8

          63.2

          62

          5

          6

          71.5

          79.2

          68

          64.4

          6

          7

          82.9

          89.7

          77.4

          74

          7

          8

          91.6

          94.6

          81.8

          77.7

          8

          8.3

          94.5

          83

          82.5

          8.3

          9

          91.3

          88

          9

          10

          94.5

          92.7

          10

          Time

          Volume of Water (Liters)

          1Lit

          1Lit

          2 Lit

          2Lit

          1Lit

          Temperature rise of water (0C)

          0

          23.1

          24

          24.1

          23.4

          0

          1

          32

          33.2

          28

          28

          1

          2

          39.9

          42

          35.7

          34.5

          2

          3

          48

          52

          42

          42

          3

          4

          55.8

          61.9

          52.3

          49.8

          4

          5

          65.4

          70.8

          63.2

          62

          5

          6

          71.5

          79.2

          68

          64.4

          6

          7

          82.9

          89.7

          77.4

          74

          7

          8

          91.6

          94.6

          81.8

          77.7

          8

          8.3

          94.5

          83

          82.5

          8.3

          9

          91.3

          88

          9

          10

          94.5

          92.7

          10

          TABLE IV: WATER BOILING RATE AT LOWER VOLUMENED

          1Litter 1 1 Litter 2

          2 Litter 1 2 Litter 2

          4 Litter 6 Litter

          8 Litter 10 Litter

          12 Litters

          Fig. 11: Boiling rate @ all volume

          Variation of the stove efficiency at small change in the volume of water boiled at constant pressure recorded shows that for 1 to 2 litter and 2 to 0.4 litter change in water volume the efficiency increases nearly with the same rate. As a result of this, as the volume of water being heated goes higher the rate at which the efficiency increases goes up. To counter check up to what volume of water the efficiency keep on raising the test continuousely.

          Efficiency at small variation of water

          50 volume

          Efficiency (%)

          Efficiency (%)

          40

          30

          20

          10

          0

          1 1.5 2 2.5

          Volume of water boiled (Litters)

          TABLE V: DATA OF WATER BOILING TEST AT HIGHER FIRE INTENSITY

          Fig. 12: Efficiency at small variation of water volume

          But as it is indicated in the two figures Fig. 13, and Fig. 14, below the efficiency kept increasing up to 43.6 % until the volume of water heated reaches 10 litter then it starts slowly declining for the test conducted while the intensity of the flame was low. But for the test conducted at relatively higher flame intensity the efficiency was rising and reaches 54.8 % at 8 litters of water and start declining however the efficiency is still higher at 10 and 12 litter with 53.1 % and 51.7% respectively. Theoretical efficiency is had it been the injector diameter of the stove were 2.16mm and actual efficiency is with injector diameter of 2.5mm. Table V and Fig. 15, shows the variation of the temperature rise of the water at different volume with respect to time.

          Fig. 13: Efficiency @ different volume of water

          Theoretical and actual efficiency of the biogas stove at relatively lower flame intensity.

          Fig. 14: Efficiency @ different volume of water

          The water boiling test conducted at constant pressure with relatively higher flame/fire intensity provides the results in the table below. The diameter of the pot in which the water was boiled is 32 cm and it has a mass of 4.5Kg including the lead.

          Time in

          minuets

          Volume of water boiled in liters

          2

          4

          6

          8

          10

          12

          Temperature of water in 0C

          0

          24.4

          24.2

          24.2

          24

          24.2

          23.9

          5

          75

          51.1

          46.4

          42.4

          38.1

          36.8

          7.5

          94.6

          10

          94.6

          83.6

          70

          62

          54.2

          51.5

          11.5

          94.6

          94.7

          11.5

          15

          94.6

          94.7

          94.8

          81.3

          69.1

          64.5

          14.6

          20

          94.6

          94.7

          94.8

          94.7

          83.2

          73.4

          18.6

          25

          94.6

          94.7

          94.8

          94.7

          94.7

          83.6

          24

          29

          94.6

          94.7

          94.8

          94.7

          94.7

          94.7

          Time in

          minuets

          Volume of water boiled in liters

          2

          4

          6

          8

          10

          12

          Temperature of water in 0C

          0

          24.4

          24.2

          24.2

          24

          24.2

          23.9

          5

          75

          51.1

          46.4

          42.4

          38.1

          36.8

          7.5

          94.6

          10

          94.6

          83.6

          70

          62

          54.2

          51.5

          11.5

          94.6

          94.7

          11.5

          15

          94.6

          94.7

          94.8

          81.3

          69.1

          64.5

          14.6

          20

          94.6

          94.7

          94.8

          94.7

          83.2

          73.4

          18.6

          25

          94.6

          94.7

          94.8

          94.7

          94.7

          83.6

          24

          29

          94.6

          94.7

          94.8

          94.7

          94.7

          94.7

          Fig. 15: Water heating rate at various water volume

        2. Controlled cooking test of Areke distilling

        In this experiment three tests have been conducted. The pot weighs 5.5 Kg and the initial temperature of the distilland was 20.80C. For the first round test initial the pot was put on the stove empty until it warms up then the level to which it heats up was checked by pouring some water in to it. Then the distilland was poured in to the pot and kept open until it boils while it has been steered before the distillation tube is put in place and sealed then left until the distillation is over.

        TABLE VI: EXPERIMENTAL RESULTS OF NEW TEST AND TEST MADE PREVIOUSLY

        Stove

        Type

        Pressure

        (mbar)

        Time

        Vbg (M3)

        Mass of

        distilland (Kg)

        Volume of

        Areke distilled (Litters)

        Existing

        9

        1:42

        2.251

        15

        2

        New

        1:24

        0.8998

        8

        1

        Existing

        8.5

        1:42

        1.972

        14

        2

        New

        1:40

        1.041

        11

        1

        Existing

        8

        1:56

        2.042

        15

        2

        New

        1:52

        1.1513

        11

        1

        The combined result presented in Fig. 11, shows the difference in the variation of heating rate for both small and larger water volume change. The volume of gas consumes to distill one litter of Areke from the previous study using existing biogas stove without skirt was 1.044 m3 while the new stove took only 0.998 m3. During the test more than one litter Areke could have been distilled if the day for the distilland to be distilled did not extended by two days which affects the alcoholic yield of the distilland said the lady from her experience. The lady added with kind of set up two litters of Areke could have been distilled.

        Distillation time and fuel consumption comparission

        2.50

        1.50

        1.00

        0.50

        0.00

        1

        2

        3

        old time

        1.70

        1.70

        1.93

        old fuel

        2.251

        1.972

        2.042

        new time

        1.40

        1.67

        1.87

        new fuel

        0.8998

        1.041

        1.041

        1.50

        1.00

        0.50

        0.00

        1

        2

        3

        old time

        1.70

        1.70

        1.93

        old fuel

        2.251

        1.972

        2.042

        new time

        1.40

        1.67

        1.87

        new fuel

        0.8998

        1.041

        1.041

        2.00

        Fig. 16: Distillation time and fuel consumption comparison

        1. Performance Evaluation

          EFFICIENCY

          EFFICIENCY

          The experimental test result of the newly designed and fabricated biogas stove showed a remarkable performance as compare to the performances of stoves tested in studies conducted previously. Even though these stoves were not made for the same purpose as the new stove developed through this study they were compare under related test conditions. The result obtained on the testes made on the previous studies showed that the stove which have the best performance was the one with smaller burner port diameter and more number of burner ports [10] and the result obtained in this study also conform the result of the previous study.

          TABLE VII: SIZE AND NUMBER OF BURNER HOLES OF DIFFERENT TYPES OF BIOGAS STOVES

          S.N

          o.

          Stove Type

          Number of holes

          Hole Size (mm)

          Inner

          Mid

          outer

          1

          Double burner (ISI) marked

          MINI

          model

          23

          6

          6

          4.00

          2

          Single burner (ISI) marked

          MINI

          model

          23

          6

          6

          4.25

          3

          Double burner LILYFLY model (ISI) marked

          30

          15

          15

          2.05

          4

          Single burner MINI model (KVIC) marked

          20

          NA

          10

          6.05

          5

          Double burner LILYFLY model (KVIC) marked

          1

          NA

          8

          6.00

          6

          Existing biogas stove being used

          NA

          NA

          20

          4.50

          7

          New Areke Distilling biogas stove

          50

          NA

          12

          3.00

          Additionally in previous study in comparing five different model biogas stoves the time taken by all the stoves to boil one litter of water rests between 9 and 11 minute for both optimum and perfectly controlled air burning conditions

          [10] while the newly designed and constructed stove in this study took only 7.5 minute to boil two litters of water.

        2. GHG Emission Reduction

        Mitigation of environmental air pollution that can be reports through this study are minimizing the release of CO and CO2 from fire wood burning which are the main GHGs and also avoiding the release of CH4 which is 25 times more pollutant than CO2 [15]. Because the cow dung which is being dumped at the backyard of traditional Areke distillers which in turn acts as a land fill and have the potential of emitting CH4.

        EFFICIENCY

        BIOGAS STOVE MODELS

        For wood combustion the CO2 emission factor reported in previous studies suggested between 1560 1620 g/kg (gram of CO2 per kilo of wood combusted) and others such as CO, CH4 and NOx are in the range 19-136 g/Kg, 6-10 g/Kg and 0.05-0.2 g/Kg respectively [12].

        EFFICIEN

        70

        60

        50

        40

        30

        20

        10

        0

        CY

        4

        NE BI ST

        COMP

        STO

        9.44

        PLESE OGAS OVW

        ARISION VES UNDE

        50.18

        DB- MINI- SHAKTI KVIC

        AMONG D R OPTIM

        51.74

        SB- MINI- SHAKTI KVIC

        IFFERENT UM BURNI

        54.8

        NEW BIOGAS STOVE

        M

        NG

        5

        MI R

        ODE

        6.56

        SB- NI- I UPAK

        L B

        SI

        IO

        5

        MI R

        GAS

        8.74

        DB- NI- I UPAK

        SI

        64.03

        DB- LILYFLY ISI RUPAK

        4

        9.44

        5

        0.18

        5

        1.74

        54.8

        5

        6.56

        5

        8.74

        64.03

        EFFICIEN

        70

        60

        50

        40

        30

        20

        10

        0

        CY

        4

        NE BI ST

        COMP

        STO

        9.44

        PLESE OGAS OVW

        ARISION VES UNDE

        50.18

        DB- MINI- SHAKTI KVIC

        AMONG D R OPTIM

        51.74

        SB- MINI- SHAKTI KVIC

        IFFERENT UM BURNI

        54.8

        NEW BIOGAS STOVE

        M

        NG

        5

        MI R

        ODE

        6.56

        SB- NI- I UPAK

        L B

        SI

        IO

        5

        MI R

        GAS

        8.74

        DB- NI- I UPAK

        SI

        64.03

        DB- LILYFLY ISI RUPAK

        4

        9.44

        5

        0.18

        5

        1.74

        54.8

        5

        6.56

        5

        8.74

        64.03

        In calculating the amount of fire wood consumed and GHGs emitted studies previously conducted indcated that in

        Fig. 17: Overall efficiency under optimum burning condition

        EFFICIENCY COMPARISION AMONG DIFFERENT MODEL BIOGAS STOVES UNDER PERFECTLY CONTROLLED CONDITION

        60

        50

        50

        41.93 43.6 43.75

        53.17

        average 76.98 kg of wood is combusted per production day at Arsi Negelle where they work 5 days per week. There are about 3500 households on the business [11]. From this the considering the worst case scenario of the Areke distillers perform their tasks throughout the year without failure the annual fire wood consumption will be: Wannum = 76.98 × 5 ×

        52 × 3500 = 70,051,800 kg/annum, The amount of CO

        EFFICIENCY

        EFFICIENCY

        40 32.26 34.15

        30

        20

        10

        0

        39.3

        released from Areke distillation process at Arsi Negelle only will be CO2emission = 111,832,362kg/annum, The amount of CO released from Areke distillation process at Arsi Negelle only will be COemission = 5,429,014.5kg/annum, The amount of CH4 released from Areke distillation process at Arsi Negelle is CH4emission = 560,414.4kg/annum, The amount

        NEPLESE SB-MINI- DB-MINI- DB-MINI- BIOGAS SHAKTI ISI SHAKTI STOVW KVIC RUPAK KVIC

        NEW BIOGAS STOVE

        SB-MINI- ISI RUPAK

        DB- LILYFLY ISI RUPAK

        of NOX released from Areke distillation process at Arsi Negelle

        only will be CO2emission = 8,756.475kg/annum and the total

        EFFICIENCY 32.26 34.15 39.3 41.93 43.6 43.75 53.17

        BIOGAS STOVE MODELS

        GHGs emitted for the three pollutants is:

        GHG = CO2emission + COemission + CH4emission + NOemission

        Fig. 18: Overall efficiency under perfectly controlled condition

        GHG

        emission

        = 118,280.547.37kg/annum

        With the current Areke distillers wood consumption pattern the amount of GHGs emitted to the environment per annum is 118,280.55tones.With the existing status of the Areke distillers having five (5) cattle in average per household it is possible to replace 27.7 % of the wood by biogas which in turn the GHG. Which will be 32,763,711.621 Kg of GHGs is mitigated at Arsi Negelle.

        E. Economics Analysis

        In considering the economic benefit and feasibility of utilizing biogas stove for traditional Areke distillation the initial investments required and savings an incomes gained due to utilization of biogas for the process has to compared. In simple economics term the payback period and the Net Present Value (NPV) has to be computed and must give a positive value with in the life of the biogas stove and digester. NPV is useful because it makes to convert future savings cash flows back to time zero and it can be calculated the following equation.

        TABLE IX: EXPENSES AND SAVINGS IN UTILIZING BIOGAS FOR TRADITIONAL AREKE DISTILLATION

        S.No

        Activities

        Type of Expense of saving

        Expense

        Savings

        1.

        Digester

        Initial

        17,000 ETB

        2.

        Stove

        Initial

        3, 000 ETB

        3.

        Cow dung cleaning

        operation

        2, 400 ETB

        4.

        Fire wood purchase

        operation

        22, 176.39 ETB

        5.

        Digester care taker

        operation

        9, 125 ETB

        6.

        Water for and cleaning

        mixing

        operation

        7, 300 ETB

        Total expenses and investments

        savings

        excluding

        initial

        16,425 ETB

        24, 576.39 ETB

        Net saving from using biogas per annum is

        8, 151.39 ETB

        With the above considerations the NPV and payback period of biogas utilization was computed in the table below and the result is found to be positive NPV and with a payback period of a little over three years and less than four years which makes it economically feasible.

        (1+)

        (1+)

        = × 1

        (23)

        TABLE VIII: PRESENT VALUES AND CUMULATIVE CASH FLOW

        Where: NPV is Net Present Value, SA is Annual saving, n is number of years and r is discount rate

        Before going into calculating the NPV it required to determine the initial investments needed for utilization of biogas for traditional Areke distillation process such as construction of biogas digester and installation of the system for biogas stove should be determined. Then the savings that will be made and additional incomes that are related with utilization of biogas should be evaluated.

        Considering the cost to build 10 m3 biogas digester is 17, 000 ETB and the cost of newly designed biogas stove to be a total of 3000 ETB, the initial expense will be 20, 000 ETB.

        Coming to the savings made by using 10m3 biogas digester, the expenses for 27.7 % of the fire wood and the expenses for cleaning the cow dung was considered and also the additional income from selling the digester byproduct as a fertilizer can also be considered.

        Saving of wood expenses with the current price of 4 ETB/Kg [14] and a replacement potential of 27.7% will be: 76.98 * 0.277*5*52*4 = 22176.39 ETB.

        Saving of cow dung cleaning cost: 50*4*12 = 2400 ETB.

        Payment for the person taking care of the digester: 25*365 = 9125 ETB

        Running cost such as expenses for 100 litters of water is used and it costs 10 birr the expense per annum will be 20birr/day *365 days/year = 7300 ETB/Annum but if the household is having a water line the expense will be 100 liters/day * 365 days/year = 36, 500 Liters which is 36.5 m3 , the expense for water with a rate of 5 birr per m3 is 36.5*5

        =182.5 ETB.

        Yea r(n)

        Initial and replacement (ETB)

        Saving (SA)

        Multiplying Factor

        PV (ETB)

        Cumulative cash flow

        (ETB)

        0

        -20000

        1

        -20000

        -20000

        1

        8151.39

        0.87

        7088.17

        -12911.83

        2

        8151.39

        0.76

        6163.62

        -6748.21

        3

        8151.39

        0.66

        5359.67

        -1388.54

        4

        8151.39

        0.57

        4660.58

        3272.04

        5

        8151.39

        0.50

        4052.68

        7324.72

        6

        8151.39

        0.43

        3524.07

        10848.79

        7

        8151.39

        0.38

        3064.41

        13913.20

        8

        8151.39

        0.33

        2664.70

        16577.91

        9

        8151.39

        0.28

        2317.13

        18895.04

        10

        3000

        5151.39

        0.25

        1273.34

        20168.39

        11

        8151.39

        0.21

        1752.09

        21920.47

        12

        8151.39

        0.19

        1523.55

        23444.03

        8151.39

        0.16

        1324.83

        24768.85

        14

        8151.39

        0.14

        1152.03

        25920.88

        15

        8151.39

        0.12

        1001.76

        26922.64

        16

        8151.39

        0.11

        871.10

        27793.74

        17

        8152.39

        0.09

        757.57

        28551.30

        18

        8153.39

        0.08

        658.84

        29210.14

        19

        8154.39

        0.07

        572.97

        29783.11

        20

        8155.39

        0.06

        498.30

        30281.41

        The NPV and payback period of biogas utilization was computed in Table VIII above considering a discount rate

        1. of 15% and annual saving of 8, 151.39 ETB using (23) . The result is found to be positive NPV and with a payback period of a little over three years which makes it economically feasible. Fig. 19, shows as the NPV is positive and Fig. 20, which the cumulative cash flow diagrams shows that the compound payback period is a little over four years.

          Fig. 19: Cash flow chart for Present values of the savings

          Cummulative cash flow

          Cummulative cash flow

          Cummulative cash flow

          40000

          30000

          20000

          10000

          0

          This study also showed a GHG emission reduction potential of up to 32,763.7 tones and attractive economic feasibility with positive NPV and payback period of less than four years. Even though the initial investments are high, with the conducive environment available for biogas production at Arsi Negelle using biogas for Areke distillation without any doubt can be a viable option for eco-friendly and economically feasible production of traditional Areke distillation.

          ACKNOWLEDGMENTS

          This work was supported by the Jimma University Institute of Technology. The support of Arsi Negele Administrators and Jimma Degitu Hotel for Biogas Testing is gratefully acknowledged.

          REFFERENCES

          1. H. R. N. JONES, Domestic Gas Burner Design, 2005, p. 208.

          2. H. R. N. JONES, The Application of Combustion Principles to Domestic Gas Burner Design, 2005, p. 42.

          3. Biogas Stove Design, no. August, 1996.

          4. H. Lindfors, Household Biogas Digester In Rural Energy Production Case comparison in Cambodia ,

            -10000

            -20000

            -30000

            0 1 2 3 4 5 6 7 8 9 101112131415161718192021

            Years

            Fig. 20: Cumulative cash flow chart

      5. CONCLUSIONS

Ethiopia and Lao People s Democratic Republic, no. March, 2010.

    1. A. A. Studies and A. T. Pems, Data Import Sheet — CCT Aprovecho Advanced Studies in Appropriate Technology.

    2. G. G. WOLDESELASSIE and THESIS, Woldeselassie and Thesis, Evaluating the Efficiency of Improved Local Liquor (Areke) Distilling Stove By Measuring the Indoor Air Emission.

      The primary concern of this study was designing, manufacturing and evaluating the performance of a biogas stove specifically for traditional Areke distillation purpose targeting the assessment of the potential in reduction of fire wood dependence and GHG emission and also the cost benefit analysis of the biogas utilization was carried out.

      The heat distribution potential of the burner can be maximized by improving the manifold diameter, number of flame port and flame port diameter. Therefore, as per the analytical design the new stove has burner port diameter of 3 mm and 62 holes while the manifold diameter is 130 mm. The frame of the stove is made from angle iron, flat iron and square pipe and it have a mechanism to help adjust the gap between the pot and burner for better control of the process temperature.

      From the water boiling test conducted up to 54.8 % overall efficiency at higher flame intensity was obtained and at a relatively lower flame intensity the overall efficiency obtained was 43.6 %. During the controlled cooking test the lady witnessed that with the time it took to distill two round of pot using biogas stove only one pot could have been distilled with fire wood. In addition to the time reduction the biogas stove did not need continuous tending of fire which makes it by far better than using fire wood. However it is advisable to use the biogas in an evenly spreading utilization schedule in the 24 hours period for better performance operation at constant pressure since the gas generation is spread in 24 hours.

    3. Popular Summary of the Test Reports on Biogas Stoves and Lamps prepared by testing institutes in China, India and the Netherlands.

    4. O. D. Olubiyi, Design_ Construction and Performance Evaluation of a Biogas Burner, 2012.

    5. C. for E. Studies, Efficiency Measurement of Biogas, Kerosene and LPG Stoves, 2001.

    6. A. F. Report, Efficiency Measurement of Biogas Stoves Submitted to Biogas Support Partnership Nepal, no. July, pp. 127, 2004.

    7. A. ABEBAW, The Potential of Biogas Energy in Replacing the Cottage Industry Energy needs for Areke Production; the Case of Arsi Negele District, Oromia Regional State., 2010.

    8. M. Brander, Greenhouse Gases, CO2, CO2 e, and Carbon: What Do All These Terms Mean? 2012.

    9. S. C. Bhattacharya, D. O. Albina, and P. A. Salam, Emission factors of wood and charcoal-ÿred cookstoves, vol. 23, pp. 453469, 2002.

    10. Q. Newsletter, Message from the Executive Director, vol. 2, no. 2, pp. 124, 2014.

    11. M. Brander, Greenhouse Gases , CO2 , CO2e , and Carbon: What Do All These Terms Mean?, 2012

Shewangizaw Werkagegnehu Demssie; MSc in Sustainable Energy Engineering and BSc in Mechanical Engineering; Director, University Industry Linkage & Technology Transfer; Lecturer, School of Mechanical Engineering; Jimma Institute of Technology (JiT); Jimma University, Jimma, Oromia ET, Ethiopia.

Prof. Dr. A. Venkata Ramayya; Sustainable Energy Engineering Chair; Professor, School of Mechanical Engineering; Jimma Institute of Technology (JiT); Jimma University, Jimma, Oromia ET, Ethiopia.

Derese Tekestebrihan Nega;

MSc in Sustainable Energy Engineering and BSc in Physics; Chair Person, Ethiopian Space Science Society Jimma Branch ; Lecturer, Department of Physics; College of Natural Sciences; Jimma University, Jimma, Oromia ET, Ethiopia.

Leave a Reply