Effect of Aspect Ratio of Fiber in HDPE Reinforced Concrete

DOI : 10.17577/IJERTV8IS090065

Download Full-Text PDF Cite this Publication

Text Only Version

Effect of Aspect Ratio of Fiber in HDPE Reinforced Concrete

Marabathina Maheshwara Rao1

1Research Scholar, Department of Civil Engineering,

Veer Surendra Sai University of Technology, Burla, Odisha, India

  1. Nikhitha Chowhan2

    2Post Graduate Student Department of Civil Engineering,

    Aditya College of Engineering and Technology, Surampalem, AP, India

    Sanjaya Kumar Patro3

    3Professor,

    Department of Civil Engineering,

    Veer Surendra Sai University of Technology, Burla, Odisha, India

    Abstract:- In recent years, with the development of industrial tech- nology, a series of reactions take place between HDPE plastic fi- bres and relate materials to form mixtures for different functions. Polymer reinforced concrete made up of HDPE fibres is known to increase the energy absorption, free shrinkage and post cracking strength. These effects are not quantified and the purpose of this paper is to show the impact of using HDPE fibres on important concrete characteristics. Basic tests on concrete like the test for workability, compressive strength test, beam flexure test and Plas- tic shrinkage tests are carried out to compare various character- istics of the HDPE polymer reinforced concrete with different fi- bre contents (i.e., 0.67% and 0.45% volume fraction over M40 and M25 grades of concretes respectively) by varying fibre aspect ra- tios (75 and 125) and are compared to the characteristics of plain concrete in order to evaluate the effect of the aspect ratios in HDPE Reinforced Concrete. Aspect ratio of fibre played a key role in effective enhancement in mechanical properties and plastic shrinkage properties of both M40 and M25 grade HDPE Fibre Reinforced Concrete over plain concrete. Least aspect ratio of FRC (i.e., 30mm length of HDPE fibres) shown better perfor- mance than the higher aspect ratio of FRC (i.e., 50mm length HDPE fibre).

    Keywords: HDPE fibre; aspect ratio; plastic shrinkage.

    1. INTRODUCTION

      Polymers are being used for various purposes and are virtually irreplaceable in the world today. Constant advancements in ma- terial and production technology has further lifted the availa- bility of polymers and diversified their use. Research on con- struction has been lately experimenting on the viability of use of polymers in concrete so as to bring out the desired charac- teristics to suit their requirements. High Density Poly Ethylene (HDPE) is a polymer of ethylene known for its high strength to density ratio and finds its use in many daily applications in life. Concrete reinforced with HDPE polymer resins is known to re- duce the permeability and control plastic shrinkage cracking and drying shrinkage cracking. Polymer reinforced concrete is known to have a superior after crack strength that prevents im- mediate failure of structures. Even though it is known that

      HDPE reinforced concrete exhibits such properties, its quanti- fied measurement and accurate mix designs are not known or standardized to find its way into daily construction activities. HDPE reinforced concrete shows different characteristics based on the type of material used and the design mix that is being implemented. Different sizes of fibres and different com- positions have to be tested to arrive at a suitable mix design that satisfies the requirements. The concrete mix is designed and proportionate quantity of fibres of HDPE rope of specific size are added and tested for the characteristics. Various tests are employed to know the properties like workability [1], density, compressive strength, flexural strength and plastic shrinkage properties of concrete. These properties are compared with the properties of both ordinary concrete and HDPE Fiber Rein- forced Concrete and corresponding recommendations are given.

    2. LITERATURE REVIEW

      J.M. Irwan et al (2013), investigated the performance of con- crete containing PET fiber of 0.5%, 1.0% and 1.5% fraction volume in order to measure the strength properties of concrete in which they concluded that the strength of the concrete will be affected by fiber content and also strong fibers are desired which helps in improving strength and ductility of concrete, but in turn may lead to loss in segregation, increased porosity, and overall reduction in concrete strength. Such that the addition of high dosages of fiber will also cause workability problems be- cause of their relatively surface area. Ninoslav Pesic et al (2016) used 0.25mm and 0.40mm diameter of HDPE fibres at a vol- ume fraction of 0.40%, 0.75% and 1.25%. The results showed that the compressive strength and modulus of elasticity were not improved using HDPE fibers and even a small amount of added HDPE fiber showed a significant result in early reduc- tion of plastic shrinkage cracking of concrete which decreases by more than 50% crack width realized at a volume fraction of 1.25% of 0.40mm diameter HDPE fibres. Sudarshan et al (2015) made an attempt to evaluate the strength properties of high den- sity polyethylene fibre reinforced concrete with varying fiber

      content from 0 to 6% and results shown an increment of Com- pressive strength by 10.63% Split tensile strength by 15.76% Flexural strength by 13.9%.As the HDPE is non bio degradable waste disposable material is much useful for the concrete works in durability aspects as it improved the strength gradually by 11.25% at 7days and 10.63% increase after 28days. Shi Yin et al (2015) made effective use of virgin and recycled polypropyl- ene fibers with 0.67% and 0.45% volume fractions in M40 and M25 grades of concrete respectively and compared the results with plain concrete [2] and concluded that there is no effect in compressive strength with the addition of these PP fibres, but a significant improvement in residual flexural strength was ob- served. Fernando Pelisser et al (2010) studied effect of different types of synthetic fibers on plastic shrinkage cracking in thin cement mortar slabs of size 910mm x 610mm x 20mm [3] using polypropylene, glass, PET and Nylon fibers with a volume fraction of 0.0%, 0.05% and 0.10% and performed tests in a climatized closed chamber rather than Paul kraais (1985) basic method of exposing the slabs to wind pressure [4]. The results have shown that the polypropylene fibers has a great effect on reduction of plastic shrinkage cracks while nylon fibers showed adverse results, Glass and PET fibres shown similar betterment in cracks as compared to the conventional thin slabs. Ruben Paul Borg et al (2016) used straight and deformed fibers of length 30mm and 50mm [5] that are obtained by shredding of recycled PET bottles while Ozgur EREN (2019) used steel fi- bers of aspect ratios 55, 65 and 80 at a fiber volume fraction of 0.5%, 1.0% and 1.5% in concrete to evaluate the effects of fi- bers on cracking potential due to plastic and restrained drying

      shrinkage. They concluded that the larger fibers has shown sig- nificant effects than that of short fibers in restraining crack de- velopment [6] and propagation while steel fibers reduced the total area of plastic shrinkage crack and maximum crack width by about 74% and 70%, respectively, compared to raw concrete.

    3. MATERIALS AND METHODOLOGY

        1. Materials Used

          Natural Godavari river sand confining to Zone II (As per IS 383

          1970) passing through 4.75mm sieve and the crushed stone aggregates of 12mm (passing through 20mm and retained on 4.75mm sieves) size were used as fine and coarse aggregates respectively and Ordinary Portland Cement of 53 Grade Dec- can Cement were used in the present study. The High Density Polyethylene (HDPE) rope of 0.4mm fiber diameter which i cut into 30mm and 50mm lengths having aspect ratios 75 and 125 are used as fibres for reinforcement. The properties of the materials are listed in Table 2.

        2. Concrete Mix Design

          Mix design for M40 Grade of concrete using 0.67% of fibres and M25 grade of concrete using 0.45% of fibres were done by following the guidelines of IS 10262: 2009. The following Table 1 gives the details of mix proportions for 1 cubic meter of M25 & M40 grades of concretes.

          Table 1. Mix proportion details

          Mix Proportions

          Grade

          Cement

          Fine aggregate

          Coarse aggregate

          W/C ratio

          HDPE Fibers (%)

          M25

          1

          2.04

          1.85

          0.50

          0.45

          M40

          1

          1.41

          2.05

          0.45

          0.67

          Table 2. Properties of Materials

          Material

          Test for

          Code for testing

          Properties

          Cement (OPC 53 Grade)

          Specific gravity

          IS 2386

          3.15 Kg/m3

          Fineness

          IS 4031 (Part 2)

          326 m2/Kg

          Initial setting time

          IS 1489 (Part 1)

          75 min

          Final setting time

          IS 1489 (Part 1)

          242 min

          Fine Aggregate

          Specific gravity

          IS 2386-3 (1963)

          2.60 Kg/m3

          Sieve analysis

          IS 383-1970

          Zone II

          Coarse Aggregate

          Specific gravity

          IS 2386-3 (1963)

          2.75 Kg/m3

          HDPE Fiber

          Density

          970 Kg/m3

          Diameter

          0.40mm

          Tensile strength

          345-490 MPa

          Elasticity Modulus

          5000 MPa

          Water absorption

          Nil

          Aspect ratio (30mm, 50mm)

          (l/d)

          75, 125

        3. Methodology:

      The present study is concerned with the comparison of proper- ties of M25 and M40 grades of plain concrete with 0.45% and 0.67% HDPE Fiber (both aspect ratios of 75 and 125, i.e., 30mm and 50mm length of fiber) Reinforced Concrete respec- tively. A set of 54 cubes, 54 prisms and 6 thin shrinkage slabs of plain and HDPE FRC samples are casted, cured and tested to compare the various properties of concrete. An attempt of evaluation of effect of aspect ratio in plastic shrinkage cracking behavior of thin cement mortar slabs has been made with ref- erence to the works done previously.

    4. RESULTS AND DISCUSSIONS

4.1 Slump Test

Slump, or measurement of the fluidity of the concrete, is also commonly specified to facilitate the placement of concrete in the formwork. The behavior of the concrete under this test is also a valuable indication of the cohesion of the mixture. A well-proportioned mixture will gradually collapse to the lowest altitude and maintain its original shape, while a mediocre mix- ture will collapse, separate and collapse.

The Fig: 1 shows the variations of slump in different mixes. It shows that the slump value decreases with addition of increased

aspect ratio of HDPE fibers for both grades of concrete. As slump value is the resemblance of its workability, from the be- low graph we can infer that the workability of concrete de- creases with the addition of HDPE fibers in the mix. The reason

is that the concrete mix with fibers makes the mix less workable. But when compared by grade wise, M25 grade of concrete is more workable than M40 grade of concrete.

Slump Test Chart

Aspect Ratio of Fiber

Aspect Ratio of Fiber

125 M40-0.67% HDPE

M25-0.45% HDPE

75

0

0 10 20 30 40 50 60 70 80 90

Slump (mm)

Fig: 1 Slump Test Chart

    1. Fresh Density Test

      Fresh density of concrete is the measure of unit weight of Con- crete. Density of Concrete is the weight per cubic meter of con- crete is calculated by dividing the weight of fully compacted concrete in the cylindrical measure by the capacity of measure in kg/cu. m. in the present study the Fresh density test is carried out in a cylindrical measure of Capacity 0.0053m3. It reflects the ability of concrete to function for structural support, dura- bility and air entrainment. This helps in calculating the yield of

      concrete per cubic meter. Fig: 2 shows that the fresh density of concrete has decreased with the increase in aspect ratio of HDPE fibers. When both M40 and M25 grades of 30mm HDPE Fiber reinforced concretes are compared, there was no such great difference in their fresh densities. The FRC with 125 as- pect ratio of fibers has least density than FRC with 75 aspect ratio and plain concretes. This is due to the formation of balling effect of fibers in the mixture due to their larger dimensions which cannot be compacted fully during tamping.

      Fresh Density Chart

      Fresh Density Chart

      M40-0.67% HDPE

      M40-0.67% HDPE

      125

      125

      M25-0.45% HDPE

      75

      M25-0.45% HDPE

      75

      0

      0

      3620

      3640

      3660

      3680

      3700 3720

      3740

      3760

      3780

      3620

      3640

      3660

      3680

      3700 3720

      3740

      3760

      3780

      Fresh Density (Kg/m3)

      Fresh Density (Kg/m3)

      Aspect Ratio of Fiber

      Aspect Ratio of Fiber

      Fig: 2 Fresh density chart

    2. Rebound Hammer Test

      Rebound hammer test or Schmidt hammer test is a non-destruc- tive test method for concrete that provides a comfortable and quick indication of the compressive strength of concrete. Fig:

      3 indicates the compressive strength of concrete of M40 & M25 grades of plain and HDPE FR Concrete which are evaluated from Rebound hammer test using calibration chart.

      Rebound Hammer Test Results

      Rebound Hammer Test Results

      M40-0.67% HDPE

      75

      M40-0.67% HDPE

      75

      0

      0

      0

      5

      10

      15

      20

      25

      30

      0

      5

      10

      15

      20

      25

      30

      Average Rebound Strength (MPa)

      Average Rebound Strength (MPa)

      125

      125

      Aspect Ratio of Fiber

      Aspect Ratio of Fiber

    3. Ultra Sonic Pulse Velocity Test

      Fig: 3 Rebound Hammer Chart

      M25-0.45% HDPE

      M25-0.45% HDPE

      cracks. The quality of concrete in terms of Ultrasonic Pulse Ve-

      Ultrasonic test on concrete is used for Qualitative assessment of strength of concrete, any discontinuity in cross section like cracks, cover concrete delamination etc. and depth of surface

      locity can be characterized with the help of following table 3 as per IS 13311-Part 1-1992.

      Table 3. Pulse velocity

      Sl. No

      Pulse Velocity (Km/s)

      Concrete Quality Grading

      1

      Above 4.5

      Excellent

      2

      3.5 to 4.5

      Good

      3

      3.0 to 3.5

      Medium

      4

      Below 3.0

      Doubtful

      From Fig: 4, since the average pulse velocities of all cube specimens of both the grades of plain and HDPE FR Concrete are greater than 4.5km/s, all the specimens are considered to be of excellent quality.

      UPV Test Chart

      125

      Aspect Ratio of Fiber

      Aspect Ratio of Fiber

      M40-0.67% HDPE

      75

      M25-0.45% HDPE

      0

      4400 4450 4500 4550 4600 4650 4700 4750 4800 4850

      Average Pulse velocity (m/s)

      Fig: 4 UPV test chart

    4. Compressive Strength of Concrete

      The test for compressive strength of concrete was performed according to IS 516-1959 on M40 and M25 grades of HDPE fibre reinforced and plain concretes. Concrete specimens of size 150mmx150mmx150mm were casted, cured for 28 days and tested under Compression Testing Machine (CTM) of 2000KN capacity at a rate of loading of 140kg/ Sq.cm. From the Fig: 5, when the strength regarding grades are compared, M40 grade of concrete has shown higher compressive strength

      than M25 grade of concrete in both plane concrete and HDPE fiber reinforced concretes at various fiber dosages and lengths. There was only an average increment of 7.61% of compressive strength from plain to 30mm FRC and a decrement of 5.4% from 30mm length HDPE FRC to 50mm length HDPE FRC which are not much noticeable. This shows that the incorpora- tion of increased length of fibers in concrete increases its strength to a very little extent as compared to plain concrete.

      Compressive Strength Chart

      M40-0.67% HDPE M25-0.45% HDPE

      Compressive Strength Chart

      M40-0.67% HDPE M25-0.45% HDPE

      125

      125

      75

      75

      0

      0

      0

      10

      20

      30

      40

      50

      60

      0

      10

      20

      30

      40

      50

      60

      Averge Compressive Strength (MPa)

      Averge Compressive Strength (MPa)

      Aspect Ratio of Fiber

      Aspect Ratio of Fiber

      Fig: 5 Compressive Strength Chart

    5. Beam Flexure Test:

      The flexural strength test on 500mmx100mmx100mm beams was performed under Two-point loading system in which equal loads are applied at a distance one-third of the two beam sup- ports in order to get pure bending according to IS 516:1959 at a rate of loading of 180kg/min. The Fig: 6 shows a drastic change of flexural strength between plain and 30mm HDPE re- inforced concrete of designed volume fraction of both grades

      than with 50mm. For M40, 16% of flexural strength was in- creased from plain to 30mm fiber while 2.2% decreased from 30mm to 50mm fiber length. Similarly, for M25, 6.69% incre- ment and 2.2% decrement in flexural strength was observed from plain to 30mm and 30mm to 50mm respectively. In all the above three cases, HDPE fiber reinforced concrete with the least aspect ratio has shown higher strengths than the plain and the FRC with highest aspect ratio.

      Flexural Strength Chart

      125

      Aspect Ratio of Fiber

      Aspect Ratio of Fiber

      M40-0.67% HDPE

      75

      M25-0.45% HDPE

      0

      0 1 2 3 4 5 6 7

      Average Flexural Strength (MPa)

      Fig: 6 Flexural Strength Chart

    6. Plastic Shrinkage Test:

Plastic shrinkage of concrete occurs where high evaporation takes place from the fresh concrete surface that tends to dry early due to high temperatures, relatively low humidity with high velocity of wind, before it sets. These shrinkage cracks impair the strength of concrete floors and pavements, such that can allow the access of hostile particles or chemicals that affect the durability and may become the reason for the initiation of larger cracks further.

To avoid plastic shrinkage cracking, the most widely accepted method is the use of randomly distributed fibers, particularly fine synthetic fibers in the lower volume fraction. In the present study, an attempt has been made to reduce these plastic shrink- age cracks in concrete by the incorporation of HDPE fibers of 75 and 125 aspect ratios, with reference to the works done by Fernando et al [3], P. Kraai [4], and Ruben Paul Borg et al [5]. The test described here, however, is not a measure of drying shrinkage, but rather the cracking potential.

Rectangular thin slabs of 910mmx610mmx20mm size were casted with 0% (plain S1), 0.67% of 30mm (S2) and 50mm (S3) HDPE Fibres for M40 grade of concrete and 0% (plain S4), 0.45% of 30mm (S5) and 50mm (S6) HDPE fibres for M25 grade of concrete to evaluate the effect of addition of HDPE fibres in fresh concrete on plastic shrinkage cracking. The ends of the slabs are restrained by 3.5mm thick L-angles over the

entire perimeter of the 19mm thick 910mmx610mm wooden plank [3]. A thick polythene sheet is to be spread on the plank before pouring the mortar for easy removal of slab after drying. Constant environmental conditions of nearly 70°C temperature and 50% relative humidity with constant wind speed are main- tained by using blow hot room heater of 2000W capacity under polythene sheet coverage as shown in Fig: 7. Two rectangular boxes of size 230mmx130mmx70mm are also arranged to note the rate of evaporation of water and mortar mass losses.

The test was carried out with Mortar i.e., mixture of water, ce- ment, fine aggregate and fibres. Coarse aggregates are avoided in this test so as to avoid the intermediate restrain of the mortar flow. A minimum of 1Kg/m²/hour of evaporation is allowed to carry out the test as per ACTM C1579-06, 2006. The readings of water loss (evaporation), temperature, humidity and mortar mass loss are taken for every hour during the test. The test was performed for 7 hours under these closed environmental condi- tions to allow the mortar to shrink. At the end of the test, the number of cracks developed on the surface of the slab as shown in Fig: 8 was keenly observed and lengths of the cracks were recorded with the help of sewing thread and scale. The experi- ments are conducted for six days with one specimen cast and test per day. The average test results of plastic shrinkage crack- ing for the 6 slabs casted were tabulated in the following Table 4.

Table 4: Plastic Shrinkage test results

Grade of Concrete

M25

M40

Volume fraction of HDPE fiber added (%)

0.00

0.45

0.00

0.67

Slab Specification

S1

S2

S3

S4

S5

S6

length of HDPE fiber (mm)

Plain

30

50

Plain

30

50

Aspect ratio (l/d)

75

125

75

125

Cracking:

Average Crack length (mm)

320

65

35

285

40

30

Number of cracks observed

18

12

3

32

9

5

Environmental Conditions:

Average temperature(C)

66

62

65

69

66

69

Relative Humidity (%)

61.10

59.60

60.40

63.00

68.30

66.90

Mixture conditions and mass loss:

Average rate of evaporation (kg/m2/h)

1.2

1.01

0.98

1.3

1.12

1.01

Mass loss (g)

38.71

35.85

30.62

34.12

33.14

30.06

As the aim of the test is to access the control of plastic shrink- age cracking with the introduction of HDPE fibers in the ce- ment mortar, from Fig: 9, a graph is plotted between the fiber aspect ratio and number of cracks formed during the test and another graph (Fig: 10) is plotted between the fiber volume fraction and aerage length of the cracks formed for M40 and M25 MPa strength concrete. Fig: 9 shown a decrement in for- mation of number of cracks with increased aspect ratio of fibers for both grades of concrete. In case of 40MPa strength, 72% of cracks are minimized with introduction of 0.67% 30mm HDPE fibers (aspect ratio 75) in the mortar mix while, 84.37% of cracks are minimized with the introduction of 50mm fibers (as- pect ratio 125) in the same cement mortar mix. The same dec- rement pattern is repeated with the 25MPa strength mixture with 33.33% of decrement by addition of 30mm HDPE fibers

and 83.33% of decrement by the addition of 50mm HDPE fi- bers of same volume fraction of 0.45. Fig 10 shows a decrement in the average plastic shrinkage crack length with the incorpo- ration of generous amount of fibers into the cement mortar for both mix grades. On an average, with an addition of 0.47% HDPE fibers, around 81% of crack length has been decreased for M25 mortar mixture and around 86% for 0.67% M40 mix- ture.

There may be a quite difference in these results as they are in- terpreted with naked eye rather than optical zoom cameras to determine the absolute crack length. But however this helps in gaining a better knowledge in reducing plastic shrinkage cracks using various volume fractions of HDPE fibers with different aspect ratios.

Fig: 7 Testing of Shrinkage Slab Fig: 8 Crack assessment of shrinkage slabs

Number of Cracks vs Aspect Ratio

125 M40-0.67% HDPE

Aspect Ratio of Fiber

Aspect Ratio of Fiber

M25-0.45% HDPE

75

0

0 5 10 15 20 25 30 35

Average number of cracks observed

Fig: 9 Number of Cracks vs Aspect Ratio

Plastic Shrinkage Crack length vs Fiber Volume Fraction

Plastic Shrinkage Crack length vs Fiber Volume Fraction

Aspect Ratio 125

Aspect Ratio 75

Aspect Ratio 0

Aspect Ratio 125

Aspect Ratio 75

Aspect Ratio 0

0

50

100

150

200

250

300

350

0

50

100

150

200

250

300

350

Average Shrinkage crack length (mm)

Average Shrinkage crack length (mm)

0.67% (M40)

0.67% (M40)

0.45% (M25)

0.45% (M25)

Volume Fraction of Fiber

Volume Fraction of Fiber

Fig: 10 Shrinkage Cracking length vs Fiber Volume Fraction

14. CONCLUSION

From the above mentioned test results, the following conclu- sions can be drawn.

The concrete mix with HDPE fibers made the mix less worka- ble such that the strength of concrete increased as it is inversely proportional to the workability of concrete.

Fresh density of concrete is reduced with an increase in Water to cement ratio and increased with increase in aspect ratio i.e., HDPE fiber length.

The flexural strength and compressive strength properties of concrete with 75 aspect ratio (30mm length) HDPE FRC was found to be higher followed by 125 aspect ratio (50mm) length HDPE FRC followed by the plain concrete one for both the M40 and M25 grades of 0.45% and 0.67% volume fraction re- spectively.

Average shrinkage cracking length and number of cracks formed on the surface of thin slab were found to be decreased with increased fiber volume fraction and aspect ratios respec- tively. As these values are obtained only by the eye judgment, better results can be expected by assessing the cracks with the help of optical microscope. However, the results obtained are remarkable.

REFERENCES

  1. Irwan JM, Asyraf RM, Othman N, Koh HB, Annas MMK and Faisal SK, The mechanical properties of PET Fibre Reinforced Concrete From Recycled Bottle Wastes, Advanced Materials Research Vol- ume 795(2013) pp 347-351.

  2. Yin Shi ,Tuladhar Rabin, Riella Jacob , Chung David , Collister Tony, Combe Mark , Sivakugan Nagartnam, Comparative evalution of Vir- gin and Recycled Polypropylene Fibre Reinforced Concrete, Con- struction and Building Materials 114 (2016) 134-141.

  3. Pelisser Fernando, Barros da S. Santos Neto Almir , Rovere La Lebre Henriette, Caldas de Andrade Pinto Roberto, Effects of the addition of Synthetic Fibres to Thin Concrete Slabs on Plastic Shrinkage Cracking, Constructions and building materials 24 (2010) 2171 2171.

  4. Karaai P Paul, A proposed test to determine the cracking potential due to drying shrinkage of concrete, the Aberdeen Group, Publication C850775-1985.

  5. Borg Paul Ruben, Baldacchino Owen, Ferrara Liberato, Early Age Performance and Mechanical Characteristics of Recycled PET Fiber Reinforced Concrete, Construction and Building Materials 108 (2016) 29-47.

  6. EREN Ozgur, Abdalkader HM Ashraf, Plastic Shrinkage Cracking of Fiber Reinforced Concrete Conference Paper-August 2006.

  7. IS: 10262-2009, Recommended Guidelines for Concrete Mix Design, Bureau of Indian Standards, New Delhi, India.

  8. Sudarshan, Manjulavani, Bhikshama V. Strength Characteristics of HDPE Concrete, International Journal of Research in Engineering and Technology, Volume 04, Special Issue: 13, 2015.

  9. Pesic Ninoslav, Zivanovic Stana, Gracia Reyes, abd Papastergiou Panos, Mechanical Properties of Concrete reinforced with Recycled HDPE Plastic Fibers, Construction and Building Materials, 115, pp 362-370, 2016.

Leave a Reply