Energy and Exergy Analysis of Coal Fired Cogeneration Power Plant

DOI : 10.17577/IJERTV3IS20737

Download Full-Text PDF Cite this Publication

Text Only Version

Energy and Exergy Analysis of Coal Fired Cogeneration Power Plant

Darshan H Bhalodia

PG Student

TIT College Bhopal

Sanjeev Yadav Assistant professor TIT College Bhopal

Abstract- In this paper an energy and exergy analysis of cogeneration power plant is presented. Most of the power plants are designed by an energetic performance criteria based on first law of thermodynamics only it gives an amount of energy inlet and outlet but it does not specify the quantity of energy losses in an environment. Real use of energy can justified by second law of thermodynamics which gives quality and quantity of energy at inlet and outlet. In this study an energy and exergy analysis of different components of coal based power plant is carried out and found out that and energy and exergy efficiency of boiler is 84.38% and 58.50% respectively.

1. INTRODUCTION

Conventional Steam power plants are widely utilized throughout the world for electricity generation, and coal is often used to fuel these plants. Although the worlds existing coal reserves are sufficient for about two centuries, the technology largely used today to produce electricity from coal causes significant negative environmental impacts. To use coal more efficiently and effectively efforts are been made to improve an efficiency of thermal power plant. Cogeneration is a technique for producing heat and electricity in one process that can save considerable amounts of energy.

To improve efficiency of thermal power plant, a heat rate improvement of only a few percent appears desirable which is carried out by analyzing an amount of heat loss in different components. Energy technologies are normally examined using energy analysis but for better understanding, complete thermodynamic view is taken by 2nd law of thermodynamics in conjunction with energy analysis, by exergy methods.

An exergy analysis is is a straight forward method for assessing and improving thermal generating stations. An exergy analysis is carried out in different components and identifies that where maximum heat loss occurs so that proper improvement can be done to increase an efficiency of coal based power plant.

technologies are making cogeneration cost-effective at smaller scales, meaning that electricity and heat can be produced for neighbourhoods or even individual sites. Micro- cogeneration systems produce heat and power at site scale for individual buildings or building complexes.

  1. COGENERATION PLANT

    In several industries, saturated steam at required temperature and pressure is used for heating purpose. Apart from heating, industries also need electric power for running various machineries and for lightening purpose. Formally in industries moderate pressure of steam was generated for power purpose and saturated steam at required pressure for heating purpose. Having two different units for generating power and for heating purpose is wasteful.

    By modifying the initial and exhaust steam pressure required power can be generated and it makes available for process heating. In cogeneration plant, the exhaust steam from the turbine is used for the process heating purpose hence process heaters are kept instead of condensers of the ordinary rankine cycle

  2. EXERGY ANALYSIS

    Exergy analysis is thermodynamic analysis technique based on the second law of thermodynamics which provides an alternative and illuminating means of assessing and comparing processes and systems meaningfully and rationally. In particular, exergy analysis yields efficiencies which provide a true measure of how nearly actual performance approaches to ideal and the causes and locations of thermodynamic losses can be identified more clearly then energy analysis. Moreover, exergy analysis helps in improving and optimizing designs.

    2. COGENERATION

    Cogeneration, or combined heat and power (CHP), is the simultaneous production of electricity and usable heat. In conventional power plants, a large amount of heat is produced but not used. By proper designing the system maximum amount of heat can be utilized hence the efficiency of energy production can be increased from current levels that range from 35% to 55%, to over 80% (DOE, 2003). New

  3. DESCRIPTION OF COGENERATION POWER PLANT The technical data of a cogeneration power plant is given

    as below:

    E out = E

    Where,

    g +E sg

    25MW Cogeneration Plant Technical Data

    E f

    = fuel energy in kJ/sec = m

    f hf

    Parameters

    Value

    Nominal power output

    9MW

    Steam generation rate

    120TPH

    Pressure, temperature & mass flow rate of main steam

    105bar/505°C/

    33.33 kg/s

    Pressure, temperature & mass flow rate of Extracted steam

    30bar/350°C/ 15.27kg/s

    Condenser pressure and temperature

    1.6bar/28°C

    Flue gas temperature

    109°C

    Fuel type

    Lignite coal

    Lower heating value

    4226 kcal/kg

    E pa =Energy of primary air in kJ/sec = m pa hpa

    E sa = Energy of secondary air in kJ/sec= m sa hsa

    E g = Energy of flue gas in kJ/sec =

    m g hg

    E sg = Energy required to generate steam from water in kJ/sec = m sg hsg

    E

    1st Law Efficiency = E out

    =98.93%.

    Exergy Part:

    I

    in

    in =f +pa +sa

    out = g +sg

    Energy and Exergy calculation of combustor considering above data is as follow:

  4. SAMPLE CALCULATION FOR COMBUSTOR

    Where,

    in =Exergy in or Availability at inlet to the combustor in kJ/sec.

    out =Exergy out or Availability at combustor outlet in kJ/sec.

    f =Specific exergy of fuel in kJ/sec. = m f (hf -T0sf )

    Energy part:

    E in =E f +E pa +E sa

    pa =Specific exergy of primary air in kJ/sec. =

    m pa (hpa -T0spa )

    sa =Specific exergy of secondary air in kJ/sec. =

    m sa (hsa -T0ssa )

    g =Specific exergy of flue gas in kJ/sec. =

    m g (hg -T0sg )

    sg =Specific exergy utilized for steam generation in evaporator kJ/sec.= m sg (hsg -T0ssg )

    destruction = in –

    Combustor.

    out

    in kJ/sec. in

    8. CONCLUSION:

    From above result and discussions following conclusion are listed below:

    And, 2nd Law Efficiency of Combustor

    II

    = out =0.5850=58.50%

    in

    Similarly calculating an efficiencies of boiler, economizer, superheater, airpreheater we get the following result.

  5. OVERALL PLANT RESULTS AND DISCUSSION

    From energy and exergy analysis maximum exergy loss (68%) occurred in economiser section which leads to damage of certain portion of tubes suffering from fouling of the tubes, corrosive scaling of the tube and insulation leakage. Also whole heat recovery system has 62% of exergy loss which demands for cleaning of damaged tubes and replacing of fouled tube with new one.

    Compo-nent

    1stlaw

    2ndLaw

    %

    Energy loss

    % Exergy Destruction

    Combustor

    98.93%

    58.50%

    1.07%

    41.50%

    Heat Recovery system

    73.20%

    37.59%

    26.8%

    62.7%

    Super Heater

    57.22%

    34.86%

    42.78%

    65.14%

    Economiser

    85.49%

    33.98%

    14.51%

    68.02%

    Air Preheater

    94.67%

    56.99%

    5.33%

    43.01%

    Comparison between exergy and energy losses

    As shown in above figure, the highest exergy loss occurs in an economiser so to increase an efficiency of power plant we have to carry out efforts to decrease exergy losses in the economiser

    The lowest exergy loss occurs in back pressure turbine as from tthe graph shown below.In case of energy loss, the highest energy loss occurs in superheater and lowest energy loss occurs in combuster.

    1. Exergy efficiency of the plant is lower than energy efficiency due to so many losses occur in the plant and energy degradation.

    2. It has been found out that 65.14% exergy loss occurs in superheater and 68.02% exergy loss occurs in economiser (heat exchanger). Which are main parts that contribute more loss of exergy.

    3. It has been found that 41.50% exergy loss occurs in combustor (furnace) which shows combustor is not fully adiabatic and combustion may not be completed. It is due to the irreversibility within the combustion process. This study indicates that the combustor requires necessary modification like refractory (insulation) modification to reduce exergy destructions thereby plant performance can be improved.

    4. The major exergy destruction(62.74%) occurs in the heat recovery system which leads to inefficient heat transfer between hot stream (flue gas) and cold stream (water & air).It indicates that heat exchanger system need to be carefully inspected.

    5. Back pressure turbine shows variation in energy and exergy losses which is due to variation in stream flow at extraction and exhaust stage according to variation in plant demand of heat and electricity. It should be optimized between heat load and electrical load at given mass ratio for better operation and to minimize the variation between energy and exergy efficiency.

    1. SCOPE OF FUTURE WORK

      The exergy method can be a useful tool for furthering the goal of more efficient energy-resource use, for it enables the locations, types and magnitudes of wastes and losses to be identified and meaningful efficiencies to be determined.

    2. REFERENCES

  1. Ibrahim Dincer and Marc A.Rosen,Exergy_Energy environment and sustainable development june 2007.

  2. Prachuab peerapong and Bundit limmeechokchai, Exergetic and thermoeconomics analyses of rice-husk power plant in Thailand Journal of Metals, Materials and Minerals, Vol.19 No.2 pp.9-14, 2009.

  3. Kaushik S.C., Reddy V.S., Tyagi S.K. Energy and Exergy analysis of thermal power plants., A Review

  4. Ganapathy T, Alagumurthi N, Gakkhar RP, Murugesan K.

    Exergy analysis of operating lignite fired thermal power plant. Journal of Engineering Science and Technology Review 2009; 2:12330.

  5. Dong Yang, Hong Xu, Haiping Chen, RuixuanJia, Analysis of the Exergy Efficiency and Influencing Factor of CFB Boiler, International Conference on Energy and Environment TechnologyVol-1, 22-525,2009

  6. P.K.Nag, Engineering Thermodynamics. Second edition.

  7. Kotas T.J., The Exergy Method of Thermal Plant Analysis.

    In: Butterworths, Essex.1985

  8. Prof. Alpesh V. Mehta, Thermodynamic Analysis of Gandhinagar thermal power station, International Journal of Advanced Engineering Technology, E-ISSN 0976-3945, December [2010].

Leave a Reply