- Open Access
- Total Downloads : 28
- Authors : Pooja M, Dr. Mohd. Z. A. Ansari
- Paper ID : IJERTCONV5IS18001
- Volume & Issue : NConPCS – 2017 (Volume 5 – Issue 18)
- Published (First Online): 24-04-2018
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Enhancing Maximum Power with Switched PV Technology under Shading Condition for both AC and DC loads
Pooja M
Assistant Professor, Dept. of EEE ATME College of Engineering
Mysuru, Karnataka, India Affiliated to VTU, Belagavi
Dr. Mohd. Z. A. Ansari, Member IEEE Professor and Head, Dept.of EEE Ghousia College of Engineering Ramanagaram, Karnataka, India Affiliated to VTU, Belagavi
AbstractThis paper aims at extracting a maximum power from a PV array under different shading condition using switched PV technology. The proposed topology enhances power once there is less isolation due to shading. The methodology proposed here is cost effective, more economical throughout partial shading, simple, reduced in size and may be easily adopted for associate existing system. The simulated results explain that the proposed system is more efficient during partial shading conditions compared to conventional system for both AC and DC loads.
Index TermsSwitched PV technology, Maximum power, Different shading, PV application, renewable energy.
-
INTRODUCTION
Currently, there is a rapid increase in electricity demand. To meet the power demand of every individual consumer, there is a wide usage of renewable energy sources. In present scenario, 30% of installed capacity are due to renewable energy sources. Solar power is one of the important and trending energy sources which can be implemented at consumer premises. The new invention and modification of PV module has helped in reducing size with greater output.
Extracting a maximum power from a solar PV module during shadowing condition is a significant measure. Foremost the P(V) and I(V) Characteristic response of solar PV modules to be analyzed for a varying isolation and temperature [1]. The effect of shading on power output and tracking maximum power point can be done using various Global power point Technique [2]. The different PV configuration, such as central inverter, string inverter, module integrated converter and differential power processing helps in extracting maximum power with their own advantages and disadvantages [3] [4]. String type of PV arrangement is more advantageous and cost effective compared to the other PV configuration with P & O MPPT control [5]. In this paper maximum power is extracted by using a string inverter configuration with switching technique. It is simulated for both AC and DC load at STC and compared with the traditional approach. The proposed scheme is more economical and efficient during partial shading condition with less investment and maintenance. The most significant advantage of the proposed topology is that, it can be implemented for an existing system. Figure 2 shows the general block diagram of the proposed topology.
-
PROPOSED SWITCHED PV ARRANGEMENT
In the proposed topology, each string has a converter and PV Panels in each string is exactly divided into 2 parts and connected to the diodes and switches as represented in the Figure 3. The proposed topology has 2 states of operation state 1 when the switch is in closed condition and state 2 when the switch is in an open condition.
When the switch is in a closed condition, we get maximum voltage of all the panels in a string, when the switch is open condition each segment will act as independent string contributing to the maximum voltage which is nearly twice that on stage 1. The Sepic converter is used because it performs the operation of Buck-Boost with non inverting output voltage. With a combination of H Bridge inverter of an AC load.
Fig.1. Types of PV Technology
III ANALYSIS OF PHOTOVOLTAIC CELL AT STC
A light energy from the sun is captured to produce electrical energy using PV cell. The mathematical modeling of PV cells is executed at STC (standard test conditions). The
data considered for a PV cell is with respect to Table 1 provided by MITSUBISHI ELECTRIC – PVUD19MF5. The
model developed in the MATLAB/Simulink environment is simulated for change in temperature with an STC of isolation and vice-versa. The P(V) and I(V) characteristics obtained stating that the output power decrease with increase in temperature above 25 degree Celsius and a decrease in isolation. These behaviors of PV cell for a change in temperature from 0-75 degree Celsius and change is isolation from 1000-250 can be seen in the graphs.(Figure 5-9)
Fig.2. Block Diagram of a Proposed Topology
Fig.3. Proposed Switched PV Arrangement
Fig.4. Subsystem Model of Solar PV cell
Fig.5. Plot of P(V) and I(V) at STC
Fig.6. Plot of P(V) for Varying Isolation at STC of Temperature
Fig.7. Plot of I(V) for Varying Isolation at STC of Temperature
IV LOAD CALCULATION
A load is an electrical component which consumes power. The generation capacity depends on the load present in a system. The load is either AC or DC. On a mean the residential users consume 5KW of power a day. Other loads like AC and DC motor can be considered where farmer uses for the aim of irrigation. The Table 2-4 gives the standard AC, DC motor load details and power consumed by residential users. On an mean load is considered to be 5KW.
Fig.8. Plot of P(V) for Varying Temperature at STC of Isolation
Fig.9. Plot of I(V) for varying Varying Temperature at STC of Isolation Table.1. 190W PV Panel Data
Parameters |
Values |
Pmp(w) |
190 |
Imp(A) |
7.71 |
Vmp(V) |
24.7 |
Isc(A) |
8.23 |
Voc(V) |
30.8 |
Rs() |
0.20758 |
Rp() |
975.6 |
µsc (k) |
1.3e-3 |
Noct |
47.5 |
Ns |
50 |
-
TECHNIQUE TO TRACK MAXIMUM POWER POINT AND SELECTION OF CONVERTER
To extract a most power throughout partial shading condition associate electronic controller is used known as MPPT controller.
Fig.10. Flowchart Indicates the Operation of P&O MPPT Technique Table. 2. Standard DC Motor Specification
Description
Motor 1
Motor 2
Motor 3
Motor 4
PV Array
1200Wp
1800Wp
3000Wp
4800Wp
Electronic
controller
Can be
adopted
Can be
adopted
Can be
adopted
Can be
adopted
Dynamic
Head
45 meters
45 meters
70 meters
70 meters
Water
Pumped
42000 lts
per day
63000 lts
per day
63000 lts per
day
100000 lts
per day
Table. 3. Standard AC Motor Specification
Description
Motor 1
Motor 2
Motor 3
Motor 4
PV Array
1200Wp
1800Wp
3000Wp
4800Wp
Electronic
controller
Can be
adopted
Can be
adopted
Can be
adopted
Can be
adopted
Dynamic
Head
45 meter
45 meters
70 meters
70 meters
Water
Pumped
38000 lts
per day
57000 lts
per day
57000 lts per
day
91000 lts per
day
MPPT controller operates in 3 steps initially it will calculate power /voltage output of a PV panel next it compares it with the Specified output and so optimizes power from the PV array to fulfill the load demand. There are many types of MPPT controller such as fuzzy logic, neural network, incremental conductance method, Perturb and Observe Technique etc.. Here we have adopted P & O method because it has more advantages such as, straight forward implementation, less power consumed, simple algorithm. The only disadvantage is that during rapid changes in a surrounding system, it takes the
Table. 4. Residential power consumed
Sl.
No.
From Date
To Date
Up To Date
Reading
Previous Reading
No of Units
1
18/1/16
18/2/16
2805
2708
97
2
18/2/16
2/3/16
2853
2805
48*2
3
18/11/15
18/12/15
2610
2519
91
4
18/12/15
1/1/16
2708
2610
98
5
18/10/15
18/11/15
2519
2417
102
6
2/3/16
2/4/16
2950
2853
97
wrong track in order to avoid this huge scale is taken into account. Figure 10 shows the Flow chart of a P&O method with controlling action of duty cycle in Table 5. For the change in surrounding temperature MPPT controller will adjust the duty cycle of the converter to optimize power for a given load can be seen in Figure 11. The duty cycle will increase or decrease to meet the global point. To track MPPT a code is written as per the flow chart using Matlab13 and called to the functional block of simulink. The inputs considered for an MPPT controller are MPPT enable, voltage and current of a panel and physical parameter.
A converter Chosen here is a Sepic converter because it can be used to vary the voltage easily to maintain constant output voltage required. The electrical stress on a deviceis is a smaller amount and it has reduced current ripple thus its additional economical than alternative converters. Together with this associate H Bridge inverter is employed to convert a power from DC to AC to fulfill AC load needs.
Case
Conditions
Position
Control Action
1
pk > 0, vk > 0
Left of MPP
Increase
2
pk > 0, vk > 0
Right of MPP
Decrease
3
pk < 0, vk < 0
Right of MPP
Decrease
4
pk < 0, vk < 0
Left of MPP
Increase
Fig.11. Change in Duty Cycle to Shift to Maximum Power Point Table.5.Control Action of Duty Cycle
-
PROPOSED SYSTEM SIMULATION AND
RESULTS
MATLAB/SIMULINK-2013b is employed to create a Simulink model. The proposed system of State 1(Figure 12) and State 2(Figure 13) is compared with the conventional system (Figure 14) for various Shading condition as shown in Table 6. The total power output for every shading pattern is recorded.
Fig. 12. Proposed State 1 switch connection
Fig. 13. Proposed State 2 switch connection
PV
Mo
dul e
No shading
10%
shading
20%
shadin g
30%
shadin g
40%
shading
50%
shadin g
1
1000
900
800
700
600
500
2
1000
900
800
700
600
500
3
1000
900
800
700
600
500
4
1000
900
800
700
600
500
Fig. 14. Conventional System Simulation Block Table.6 Shadowing Pattern
Fig. 15. Proposed System Simulation Block Fed to DC load
Fig. 16. Proposed System Simulation Block Fed to AC load
Figure 15-16 are the complete Simulink block of a proposed system fed to AC and DC load. Figures 17-22 show the plot of power output in watts for all shading condition fed with AC and DC load. The Simulink result recorded is tabulated in the Table 7-8. The power output is same for all the case when there is no shadow. Proposed state 1 is comparable to conventional system where in state 2, the output power obtained for different shadowing condition is greater compared with other condition. The power obtained in state 2 is more than twice the power of state 1 and as well as of conventional system during 40% and 50% of shading condition.
Table. 8. Power Output of AC load in Watts
PV
Modul e
No shadi
ng
10%
shadin g
20%
shadin g
30%
shadin g
40%
shadin g
50%
shading
Con
5000
4100
3200
2500
1800
1250
State 1
5000
4250
3400
2550
1900
1300
State 2
5000
4700
4555
4416
4150
3800
Fig. 17 (a f) Power output of different shading Pattern in Watts of a Conventional System Fed to DC Load
Table. 7. Power Output of DC load in watts
PV
Modul e
No
shadi ng
10%
shadin g
20%
shading
30%
shadi ng
40%
shadin g
50%
shading
Con
5100
4200
3350
2500
1900
1250
State 1
5000
4270
3400
2600
1900
1330
State 2
5300
4950
4627
4320
4050
3750
Fig.18. (a f) Power output of different shading Pattern in Watts of a Conventional System Fed to AC Load
Fig.19. (a f) Power output of different shading Pattern in Watts of a Proposed State 1 Fed to DC Load
Fig.20. (a f) Power output of different shading Pattern in Watts of a Proposed State 1 Fed to AC Load
Fig.19. (a f) Power output of different shading Pattern in Watts of a Proposed State 2 Fed to DC Load
Fig.22. (a f) Power output of different shading Pattern in Watts of a Proposed State 2 Fed to AC Load
-
CONCLUSIONS
The Simulink model of a PV array with dfferent shading conditions were implemented for AC and DC loads and the comparative results for conventional and proposed system were tabulated. From the simulation results obtained it can be observed that the power output of the proposed system varies between 4 – 200% for DC loads for no shading to 50% shading condition, whereas for AC loads, it varies between 0
204%. Hence it can be concluded that the proposed system is more efficient than the conventional system during partial shading to obtain maximum power with low investment cost.
ACKNOWLEDGEMENT
The authors would like to thank the authorities of Ghousia College of Engineering, Ramanagaram and ATME College of Engineering Mysuru, for all support and encouragement received in carrying out this work.
REFERENCES
-
Habbati Bellia, RamadaniYoucef, and Moulay Fatima, A detailed Modeling of Photovoltaic module using MATLAB, NRIAG Journal of Astronomy and Geophysics, pp. 53-61, May 2014.
-
G. Smita Ganesh Pachpande,and Prof. Pankaj H. Zope, Studying the effect of shading on Solar Panel using MATLAB, International Journal of Science and Applied Information Technology,Vol.1,No. 2,May-June 2012.
-
P.S. Shenoy, K.A.Kim, B.B. Jhonson, and P.T. Krein differential Power Processing for increased energy production and reliability of photovoltaic system, IEEE trans on Power Electronics, Vol.28, No. 6, June 2006.
-
J.M.A. Myrzik, and M. Calais, String and module integrated inverters for single phase grid connected photovoltaic systems-A review, 2013 IEEE Bologna Power Tech Conference, Vol. 2, 2003.
-
Smitha Ganesh Pachpande, Prof. Pankaj H. Zope, studying the effect of shading on solar panel using MATLAB, International journal of science and applied information Technology, Vol 1 .N02, May-June 2012