Enhancing the Structural Performance of Column using GFRP Rebar and Hybrid Fiber

DOI : 10.17577/IJERTV9IS050827

Download Full-Text PDF Cite this Publication

Text Only Version

Enhancing the Structural Performance of Column using GFRP Rebar and Hybrid Fiber

  1. V. Manjari Blessing1

    Assistant Professor, Department of Civil Engineering,

    Anna University Regional Campus Coimbatore, Coimbatore, India.

    1. Vignesp

      M.E- Structural Engineering,

      Anna University Regional Campus Coimbatore, Coimbatore, India.

      Abstract Glass fibre reinforced polymer (GFRP) rebars is a proven and successful alternative reinforcement that will give structures a longer service life as well as noncorrosive material properties. In this, present study an experimental study on columns with hybrid fibre and GFRP rebars was performed. Their performance was evaluated by comparison with a conventional steel reinforced column. Six hybrid columns with fibre and GFRP rebar and three conventional concrete steel reinforcement columns were casted and tested under different eccentric (0,0) (0,25) (0,50) loadings. The fibres used were steel and glass fibres which improves the concrete strength property. Tests were done to check the load carrying capacity of columns for both axial and eccentric loads, deflection, and buckling nature of column. The GFRP rebars were able to withstand the peak concentric and eccentric loads without crushing and local buckling. Also after load removal, deflected GFRP column regained its original position and crack width also reduced. In steel reinforced column, steel rebar were yielded column and after load removal, no deflection regain and crack width reduction were found. The performance of HYFC rebar was 18% greater while considering to that of conventional concrete column.

      Keywords Elastic instability; GFRP; Hybrid fiber; load carrying capacity

      1. INTRODUCTION

        1. General

          Columns are important structural members which carry the load from the beams and upper columns to transfer the ground through foundations. Column failure can cause elastic instability due to load carrying capacity of RCC columns reduced drastically for actual cross sectional area and percentage of reinforcement steel, crushing failure due to high axial load compared to cross sectional area of the members causes the RCC vertical member is crushed failure or material failure.

          The most popular drawback for corrosion steel reinforcement due to aggressive environments, voids present in RCC member, coastal regions that cause weak tension strength of reinforcement hence failure of columns. Glass Fiber reinforced polymer (GFRP) rebar is a satisfying replacement or auxiliary for this condition because of its high tension strength (1600Mpa), noncorrosive characteristics.

          ACI 440-1R-06 reported in the US typical uses GFRP rebar to constructed bridge deck, in 1997. FRP- composite material consisting of continuous fibers impregnated with a fiber binding polymer then moulded and hardened in the intended shape. Hybrid a combination of two or more different fibers, such as carbon and glass or carbon and aramid, in to a structure

          In this present work was to investigate structural behavior of columns load vs deformational character, load carrying capacity for different eccentric conditions, spiffiness of the HYFRC column with GFRP compared the conventional steel reinforcement column. Hybrid fiber used to enhancing the concrete strength properties and prevent the crushing failure or material failure.

        2. Hybrid fibre

          Fibres are mostly used for special requirement only. the fibre used in concrete to increase the concrete strength properties and prevent the shrinkage crack, bleeding of water etc. different type of fibre such as glass fibre, coconut fibre, glass fibre, polypropylene . A composite can be termed as hybrid, if two or more types of fibres are rationally combined in a common matrix to produce a composite that drives benefits from each of the individuals fibres and exhibits a synergetic response.

        3. GFRP rebar

        Glass fibre reinforced polymer (GFRP) rebar is sold bar which contain of thinnest glass fibre embedded in a polymeric resin matrix and additives. The major cause of deterioration among reinforced concrete structures is corrosion of the reinforcing steel. Among others, one viable option is to reinforce concrete with glass fiber-reinforced polymer (GFRP) bars, a non-corrosive material.

        GFRP reinforcing bars are made primarily of glass fibers. Being non-corrosive, GFRP bars can help extend the lifecycle of reinforced concrete structures substantially, as well as reduce their maintenance, repair, and replacement costs. While GFRP is becoming a viable reinforcement alternative, it presents design challenges which are different than those in the design of conventional steel reinforced concrete.

      2. MATERIAL USED

        1. Cement

          Ordinary Portland cement conform to IS 10262-2009 JSW cement 53 grade produced from single source was used

          TABLE 1 PROPERTIES OF CEMENT

          Properties

          Specifications

          Specific gravity

          3.15

          grade

          53

        2. Fine aggregate

          Locally available river sand was used as fine aggregate which passes through 4.75mm sieve as per IS 383-1978

          TABLE 2 PROPERTIES OF FINE AGGREGATE

          Properties

          Specifications

          Specific gravity

          2.67

          Fineness modulus

          2.8

        3. coarse aggregate

          Locally available coarse aggregate was used as coarse aggregate which passes through 20mm to retain 12.5mm sieve as per IS 383-1978. The specific gravity of the coarse aggregate is 2.74.

        4. water

          Potable water which is available in laboratory is used for casting and curing of specimen as per IS 456-2000. W/C .45 was in mix.

        5. Steel fibre

          Defined as short, discrete length of steel fibres with an aspect ratio 20 to 100 with different types of steel fibres is used for concrete reinforcement. Round fibres are the most common type and their diameter ranges from 0.25 to 0.75 mm. Rectangular steel fibres are usually 0.25 mm thick.

          TABLE 3 PROPERTIES OF STEEL FIBRE

          Properties

          Specifications

          Type of steel fibre

          Crimped

          Length

          50mm

          Diameter of fibre

          0.5mm

          Aspect ratio

          100

          Percentage

          0.75 % (volume of cement)

        6. Glass fibre

          Glass fibre is a material consisting of numerous extremely fine fibres of glass. Glass fibre thinnest fibres are the strongest because the thinner fibres are more ductility.

          TABLE 4 PROPERTIES OF GLASS FIBRE

          Properties

          Specifications

          Type of Glass fibre

          Alkali resistant

          Length

          12mm

          Diameter of fibre

          0.05mm

          Aspect ratio

          240

          Percentage

          0.75 % (volume of cement)

        7. GFRP rebars

          GFRP- Fibreglass and composite material consisting of continuous fibres impregnated with a fibre binding polymer then moulded and hardened in the intended shape. Non corrodible, high tensile strength, low weight compare to steel. Different diameter is available 6mm, 8mm, 10mm, 12mm, and 16m.

          TABLE 5 PROPERTIES OF GFRP

          Properties

          Specifications

          Tensile strength

          483 to 1600 Mpa

          Modulus of elasticity

          51.0 Gpa

          Density

          1.25 to 2.1 g /cm3

          TABLE 6 MECHANICAL PROPERTIES OF GFRP

          Diameter ( mm)

          Area (mm2)

          Density (g/cm3)

          Tensile strength (Mpa)

          Modulus of elasticity

          (Gpa)

          6

          28.27

          1.25

          1600

          51.0

          8

          50.26

          1.25

          1600

          51.0

          10

          78.5

          1.25

          1500

          51.0

          12

          113.09

          1.25

          1350

          51.0

          16

          201.06

          1.25

          1150

          51.0

        8. Concrete mix proportion

        Mix proportion of M35 grade concrete was designed as per IS 10262-2009 and IS 456-2000.

        TABLE 7: MIX PROPORTION

        Properties

        Specifications

        Grade

        M35

        Ratio

        1:1.6:2.5

        Water cement ratio

        0.45

      3. TEST PROGRAM

        The test program consisted of 9 concrete columns measuring 150mm x150mm x1000mm cross section, the test column could be specified as a short column because the slenderness ratio (L/d) of the specimens was less than to 12, that is, less than 22 based on ACI 318-14 [24]. The tested specimens were divided into three groups, as shown in Table 1. Each group consisted of two concrete columns with the same reinforcement details but tested under different eccentricity conditions of 0, 25, and 50mm ( equal tov( 0,0), (0,25), and (1,50), respectively). The specimens were identified on the basis of the longitudinal and tie reinforcement material (steel or GFRP), diameter of the longitudinal bar, tie spacing, and eccentricity amount of the applied load. For example, specimen G10-T150-E0.0 is reinforced with GFRP bars and ties, four 10 mm diameter bars were used as longitudinal reinforcement, tie spacing was 150 mm, and it was tested under concentric load. the first group (S10-T150, reference specimens) consisted of three concrete columns reinforced with four Ø10 longitudinal steel bars and Ø6 steel ties placed at a spacing of 150 mm. the columns in the three other groups were reinforced with GFRP bars and tie. The dial gauge was positioned at mid height to measure the lateral deflection of the column during the loading stage.

        TABLE 8 DETAILS OF TESTED SPECIMEN

        S. no

        Specimen

        Type of bar

        Main bar

        Lateral tie

        1.

        S10-T150-E0,0

        STEEL

        4Y-10

        Y6 AT 150mm

        S10-T150-E0,25

        4Y-10

        Y6 AT 150mm

        S10-T150-E0,50

        4Y-10

        Y6 AT 150mm

        2.

        G10-T150-E0,0

        GFRP

        4Y-10

        Y6 AT 150mm

        G10-T150-E0,25

        4Y-10

        Y6 AT 150mm

        G10-T150-E0,50

        4Y-10

        Y6 AT 150mm

        1. Cube test result

          Fig: 1 Column test setup

      4. TEST RESULTS

Compressive strength is the maximum compressive stress that, under a gradually applied load, given solid material can sustain without fracture. Compressive strength is calculated by dividing the maximum load by the original cross section area of the specimen in compression test. Cube test result mentioned below in table 9 (7 days test)

TABLE 9 TEST RESULTS OF COMPRESSIVE STRENGTH OF CONCRETE

S.no

Specimen

Dimension (mm)

Initial load (kn)

Final load (kn)

Compressive strength (n/mm²)

Percentage of strength compare hyfrc to cc

1.

CC

150×150

571

621

27.62

8 % Increase

17 % Increase

24 % Increase

20 % Increase

2.

HYFRC 0.9%

150×150

629

670

29.77

3.

HYFRC 1.1%

150×150

683

726

32.26

4.

HYFRC 1.3%

150X150

712

770

34.22

5.

HYFRC 1.5%

150X150

706

738

32.82

Fig: 2 cube test result

  1. Experimental test results on the column load carrying capacity

    The section discussion for test results of steel reinforcement RCC column and HYFC with GFRP rebar RCC column. All specimen were tested under the different eccentric (0,0) (0,25) (0,50) load condition they failed and their reached maximum load carrying capacity. The moment and stiffness are finding as the maximum load vs horizontal deflection at maximum load.

    The results are show table: 10.

    TABLE 10 RESULTS FOR TESTED SPECIMEN

    S. no

    Specimen

    Emin (mm)

    PMax (KN)

    YMax (mm)

    MMax (KN.m)

    1.

    S10-T150-E0,0

    0

    179

    1.30

    0.234

    S10-T150-E0,25

    25

    126

    8.50

    1.077

    S10-T150-E0,50

    50

    94

    12.7

    1.238

    2.

    G10-T150-E0,0

    0

    210

    1.45

    0.30

    G10-T150-E0,25

    25

    137

    11.45

    1.56

    G10-T150-E0,50

    50

    85

    16.7

    1.42

    1. Conventional column reinforced with steel bar

      For column specimen 1:

      Fig: 3 Load vs Deflection S10-T150-E0, 0

      For column specimen 2:

      Fig: 4 Load vs Deflection S10-T150-E 0, 25

      Fig: 5 Load vs Deflection S10-T150-E 0, 50

    2. Hyfrc column reinforced with gfrp rebar eccentricity (0, 0)

      For column specimen 1:

      For column specimen 2:

      Fig: 6 Load vs Deflection G10-T150-E 0,0

      Fig: 7 Load vs Deflection G10-T150-E 0, 0

    3. Hyfrc column reinforced with gfrp rebar eccentricity (0, 25)

      For column specimen 1:

      Fig: 8 Load vs Deflection G10-T150-E 0, 25

      For column specimen 2:

      Fig: 9 Load vs Deflection G10-T150-E 0, 25

    4. Hyfrc column reinforced with gfrp rebar eccentricity (0, 50)

      For column specimen 1:

      For column specimen 2:

      Fig: 10 Load vs Deflection G10-T150-E 0, 50

  2. Load vs Moment characteristics

    Fig: 11 Load vs Deflection G10-T150-E 0, 50

    Maximum moment was calculated as the maximum load multiplied by the summation of initial eccentricity and lateral displacement at maximum load.

    1. Conventional column reinforced with steel bar

      For beam specimen 1:

      Fig: 12 Load v Moment S10-T150-E0, 0

      For column specimen 2:

      Fig: 13 Load vs Moment S10-T150-E0, 25

      For column specimen 3:

      Fig: 14 Load vs Moment S10-T150-E0, 50

    2. Hyfrc column reinforced with gfrp rebar eccentricity (0, 0)

      For column specimen 1:

      Fig: 15 Load vs Moment G10-T150-E0, 0-1

      For column specimen 2:

      Fig: 16 Load vs Moment G10-T150-E0, 0-2

    3. Hyfrc column reinforced with gfrp rebar eccentricity (0, 25)

      For column specimen 1:

      Fig: 17 Load vs Moment G10-T150-E0, 25-1

      For column specimen 2:

      Fig: 18 Load vs Moment G10-T150-E0, 25-2

    4. Hyfrc column reinforced with gfrp rebar eccentricity (0, 50)

      For column specimen 1:

      For column specimen 2:

      Fig: 19 Load vs Moment G10-T150-E0, 50-1

      LOAD VS MOMENT

      LOAD VS MOMENT

      150

      100

      50

      0

      150

      100

      50

      0

      0

      1.2 2.4 3.6 4.4 5.2

      6 6.8 7.6 8.4 9.2

      0

      1.2 2.4 3.6 4.4 5.2

      6 6.8 7.6 8.4 9.2

      MOMENT (kN-m)

      MOMENT (kN-m)

      LOAD (KN)

      LOAD (KN)

      Fig: 20 Load vs Moment G10-T150-E0, 50-2

  3. Compare load carrying capacity of hyfrc column reinforced with gfrp rebar to conventional column

    TABLE 11 TEST RESULT OF LOAD CARRYING CAPACITY

    S. no

    Specimen

    Max load (kn)

    Avg load(kn)

    Max mm

    1.

    S10-T150-E0,0

    179

    179

    1.30

    G10-T150-E0,0

    210

    191.5

    1.45

    G10-T150-E0,0

    173

    2.

    S10-T150-E0,25

    126

    126

    8.85

    G10-T150-E0,25

    135

    124.5

    12.25

    G10-T150-E0,25

    117

    3.

    S10-T150-E0,50

    94

    94

    11.85

    G10-T150-E0,50

    76.5

    72

    18.1

    G10-T150-E0,50

    67.5

    Fig: 21 Load vs Deflection G10-T150-E0, 0 AND S10-T150-E0, 0

    Fig: 22 Load vs Deflection G10-T150-E0, 25 AND S10-T150-E0, 25

    DEFLECTION(mm)

    DEFLECTION(mm)

    Fig: 23 Load vs Deflection G10-T150-E0, 50 AND S10-T150-E0, 50

    LOAD VS DEFLECTION

    LOAD VS DEFLECTION

    12

    10

    8

    6

    4

    2

    0

    S10-T150-E0,0

    12

    10

    8

    6

    4

    2

    0

    S10-T150-E0,0

    S10-T150-E0,25

    S10-T150-E0,50 G10-T150-E0,0 G10-T150-E0,25 G10-T150-E0,50

    S10-T150-E0,25

    S10-T150-E0,50 G10-T150-E0,0 G10-T150-E0,25 G10-T150-E0,50

    0

    15

    30

    45

    65

    75

    85

    105

    125

    145

    155

    165

    175

    185

    0

    15

    30

    45

    65

    75

    85

    105

    125

    145

    155

    165

    175

    185

  4. Stiffness

    Fig: 24 Load vs Deflection hyfrc with gfrp normal

    Stiffness is the rigidity of an object the extent to which it resists deformation in response to an applied force.

    Stiffness is measured in force per unit length (N/mm), and is equivalent to the force constant in Hookes Law.

    Stiffness K = P/

    TABLE 12: INITIAL STIFFNESS AND FINAL STIFFNESS

    S.no

    Specimen

    Initial stiffness (N/mm)

    Final stiffness (N/mm)

    Average X 103N/mm

    1.

    S10-T150-E0,25

    13.12

    14.25

    14.25

    2.

    G10-T150-E0,25

    12.41

    11.05

    11.7

    3.

    G10-T150-E0,25

    11.5

    12.35

    4.

    S10-T150-E0,50

    7.25

    7.58

    7.58

    5.

    G10-T150-E0,50

    5.532

    6.818

    5.884

    6.

    G10-T150-E0,50

    6.25

    4.95

  5. Crack pattern

S10-T150-E0, 0 S10-T150-E0,25 S10-T150-E0,50

G10-T150-E0,0 -1 G10-T150-E0,25 -1 G10-T150-E0,50-1 G10-T150-E0,0 -2 G10-T150-E0,25 -2 G10-T150-E0,50-2

Fig: 25 Ultimate load crack profile

V.CONCLUSION

The following conclusions were drawn based on the experimental investigation on eccentric behavior of column

  • The load carrying capacity of eccentricity (0, 0) HYFRC column with GFRP was found to be 18% greater than the value of conventional concrete column.

  • The maximum deflection noted at their ultimate axial load in the GFRP rebar and normal steel reinforcement column are 1.45 mm and 1.3 mm respectively.

  • Percentage of eccentricity increase in GFRP column is very similar to behaviour of conventional reinforced column

  • All eccentric loaded GFRP columns showed no rebar failure and the column top compression zone crushing failure occurred.

  • Hybrid fibre performed well with increase in compressive strength and prevention of fine cracks.

  • The moment carrying capacity GFRP column was 5% higher than the steel reinforcement column.

  • The increase of eccentricity of GFRP column decreased the stiffness compare to axial stiffness

  • The GFRP column with increase in the eccentricity without local buckling or elastic in stability

  • GFRP column had large deflection capacity without failure compared to steel reinforcement column.

REFERENCES

  1. ACI 440.1R-06 Guide for the design and construction of structural concrete reinforcement with FRP bars .USA2015

  2. ACI319:1989 building code requirements for reinforced concrete, American concrete institute.

  3. Ahmed heidayet mohammed(2019), behaviour of eccentric concrete column reinforced with carbon fibre reinforcement polymer bar, international journal of emerging trends of technology in computer science.

  4. Nandini devi and deepi (2017), performance of concrete column with glass fibre reinforced polymer rebar under axial loading.

  5. IS456-2000, plain and reinforced concrete code of practices Indian standard.

  6. IS456-1978, Design aids for reinforced concrete to sp16.

  7. AS3600:1988, concrete structure, standards association of Australia.

  8. American concrete institute, building code requirements for structural concrete (ACI318-16), USA, 2014

  9. M.N.Sheikh, Experimental investigation on circular concrete columns using GFRP bars and helices under different loading conditions journal of composite for construction vol.20, No: 4, article 04016009:2016.

  10. B.Benmokrane, strength of circular HSC columns reinforced internally with CFRP bars under axial and eccentric loadings, constructoin and building materials, vol.141, pp.336-378, 2017