Experimental Analysis of Evacuated Tubular Collectors with Plain & Concave Reflectors

DOI : 10.17577/IJERTV3IS040400

Download Full-Text PDF Cite this Publication

Text Only Version

Experimental Analysis of Evacuated Tubular Collectors with Plain & Concave Reflectors

Paul Thomas[1], Praveen Ajith[1], Arjun Palayakkodan[1], M. Natarajan[2]

1 Mtech Energy & Environmental Engineering,

4 Faculty, Energy Division, School of Mechanical & Building Sciences, VIT University, Vellore-632014, Tamil Nadu, India

AbstractThis paper presents about the comparative tests between three different types of solar thermal collectors. A standard evacuated tubular collector, two evacuated tube collector with external plain and concave reflector attached below the tubes. The tests are carried out under same experimental conditions in order to compare the performance analysis.

Efficiencies of the three experimental setups are determined at different mass flow rates and solar flux. The test is conducted at the VIT University, Vellore in the last week of October 2013 after optimizing the position of setup with respect to the latitude and longitude of the place.

The purpose of this work is to find out which one is experimentally efficient, and to determine the amount by which the performance has been increased. The experimental analysis shows that the efficiency is higher for evacuated tubular collector with concave reflector. The plain reflector reflects the incident radiation depending upon the incident angle whereas concave reflector concentrates the same on to the focal line. This paper discusses about how the analysis is done and made the conclusions.

Keywords: Efficiency, Evacuated tube collector, Reflector

  1. INTRODUCTION

    In this era, the demand for the energy is increasing day by day. Majority of the energy production is from conventional energy sources like fossil fuels. As these sources are not sufficient in quantity to meet the growing demand, the stepping to the renewable sources of energy is very essential. The renewable sources can be utilized for many applications. One of them is the utilization of solar energy to heat the water. The solar thermal collectors absorb the incident solar energy to heat up the running water through the tubes. Different types of solar thermal collectors are available based on the requirements, amount of heating required etc. and researches are going on to find out the ways to increase the efficiency further.

    In the case of solar thermal collectors, the two main types are flat plate collector and evacuated tube collectors. In both types, water is used as the transferring medium for heat. The evacuated tubular collector consists of glass vacuum sealed tubes. The presence of vacuum medium reduces the conductive and convective losses when compared to flat plate collector.

    The evacuated tube collectors may be subdivided in two types. In the direct flow heat transfer liquid is pumped through the tubes. The second type consists of heat pipes inside vacuum sealed glass tubes.

  2. EXPERIMENTAL APPARATUS

    The experimental work was done after fabricating a sample test setup (Figure: 1.0) with single glass evacuated copper tube in each set. A plain and concave mirror made of high reflective material was attached below the evacuated tubes to divert the incoming radiation into the tubes. The aperture of the concave reflector is adjusted so that the radiation concentrates on the evacuated tube. These are protected by a wooden box and are insulated to reduce the losses. The copper tubes carry the water medium for heat transfer. Two header pipes made of copper having a slightly larger diameter are attached to the both ends of the evacuated tubes for making the inlet and outlet.

    Fig: 1.0 Experimental apparatus

    For all the setups inlet and outlet connections are made. The inlet is connected to an external water tank of 20L whose mass flow rate can be adjusted with the help of a rotameter which was calibrated initially. Thermocouples are attached to the inlet and outlet valves. A Pyranometer and Pyreheliometer were used to measure the global radiation and beam radiation respectively.

    Table 1.0: Specifications of the Experimental Setup

    The efficiency is given as to

    = F. [()en. UL . Tm*] (2)

    where Tm* is the reduced temperature difference.

    IV. EFFICIENCY IN NORMAL CONDITIONS

    The performance of three apparatus is compared on the basis of the efficiency obtained under the identical experimental conditions. The experiment was performed with two different mass flow rates and different solar radiations. For a particular mass flow rate, the inlet temperature, outlet temperature, ambient temperature, global radiation and beam radiation are measured. The same is repeated at regular intervals for obtaining different values. The rotameter used for controlling the mass flow rate is calibrated initially. The losses occurred in the determination of efficiency is not taken into account since all the three apparatus have the same design. The analysis involves the study of increased efficiency due to the increase in the outlet temperature of the evacuated tubes with reflector.

    The efficiency is given by

    No.

    Components

    Dimensions

    1

    Copper tube Diameter

    12.5mm

    2

    Copper tube thickness

    0.5mm

    3

    Effective length of Copper tube

    978mm

    4

    Header pipe diameter

    19.05mm

    5

    Header pipe length

    200mm

    6

    Separation between Cu tube & glass tube

    25mm

    7

    Length of plane reflector

    1000mm

    8

    Width of plane reflector

    200mm

    9

    Thickness of plane reflector

    2mm

    10

    Length of concave reflector

    1000mm

    11

    Width of plane reflector

    200mm

    12

    Thickness of plane reflector

    2mm

    13

    Distance to the focal line from reflector

    125mm

    Efficiency, = mw

    . Cp . ( To

    Ti ) / Is

    . A (3)

    The experimental apparatus is located at the VIT University, Vellore, India. Based on the location coordinates, the apparatus is placed focusing towards the south. The experiment is carried out in the last week of October 2013 which was partially cloudy.

    Table 2.0. Installation condition of the Experimental Setup

    Location

    VIT University/ Vellore/ Tamil Nadu/India

    Latitude

    12.9692° N

    Longitude

    79.1559° E

    Tilt angle

    20°

    Direction

    South

  3. EFFICIENCY IN STEADY STATE CONDITIONS

    The useful output power of a solar collector for near normal incidence angle of the solar radiation during steady state conditions is given by Duffie and Beckman as

    Q = F'. Aa . [()en. Ig UL . (tm-ta)] (1)

    where Q is the useful output power transmitted to the liquid, F' the collector efficiency factor, Aa the aperture area of collector, ()en the effective transmittanceabsorptance product at normal incidence, Ig the global solar irradiance, UL the overall heat los coefficient and (tm-ta), the difference between the average fluid temperature in the collector tm and the ambient air ta..

    Where, A the absorber area of collector, Is the global solar irradiance, (to-ti) the difference between the outlet temperature and inlet temperature. The global solar irradiation can be measured by the pyranometer which is having a sensitivity of 12.56*10-3 mV.

    1. RESULTS & DISCUSSIONS

      The experiments were carried out on that particular day and the observations were analyzed. The highest global radiation occurred at 11:40am comes to 931.53 W/m2 and the lowest is at 11:15am which comes to 660.82 W/m2.

      The Figure 2.0 shows the relation between efficiency and solar flux. It is observed that the efficiency of the evacuated tube collectors varies with the variation in solar flux. The figure below shows the variation of efficiency with respect to solar flux for a mass flow rate of 24 LPH. Out of the three, the efficiency is higher for concave reflector. The maximum efficiency obtained for concave reflector is 28.29 %, whereas for plain reflector is 23.94% and the lowest value 19.58% which is for tube without reflector.

      Fig 2.0: Graph between Efficiency & Solar flux at a mass flow rate of 24LPH

      For the mass flow rate of 36 LPH, the efficiency curve gradually increases with increase in the solar flux. The fluctuation in efficiency is lower when compared to the previous one. It is observed that the maximum efficiency for concave reflector is 27.13%, for plain reflector is 26.18% and 20.05% for without any reflector. As in the below Figure 3.0, the efficiency variation is less than 2% for a change in the flux of 50W/m2. The efficiency obtained for concave reflector varies between 25.34% and 27.13%, for plain reflector the variation is between 19.36% and 25.17%. In the case of tube without any reflector efficiency varies from 16.47% to 20.05%.

      Fig 3.0: Graph between Efficiency & Solar flux at a mass flow rate of 36LPH

      Relating the temperature difference between outlet and inlet to the solar flux, it is observed that the rise in temperature is higher at higher values of solar flux. Figure.4.0 shows the variation between the temperature difference of outlet and inlet with respect to Solar flux. The graph follows the same trend as the efficiency curve. A maximum rise of 3.4oC is observed for concave reflector type. All the three types follow the same trend in this observation. Considering the lowest points, for tube without reflector, at least 1.6 oC rise is there at the outlet. In the case of Plain reflector and Concave reflector, 1.8 oC and 2.2 oC is noted.

      Fig 4.0: Graph between Temperature Difference & Solar flux at a mass flow rate of 24LPH

      When compared to the 24LPH, again the temperature rise observed is lower according to the solar flux. The temperature difference varies from 2.0oC to 2.3oC for concave reflector and is from 1.5oC to 2.2oC for tube with Plain reflector. For a mass flow rate of 36LPH, the rise in temperature reduces to

      1.4 oC, the lowest value observed.

      Fig 5.0: Graph between Temperature Difference & Solar flux at a mass flow rate of 36LPH

      As seen from the above figures, the temperature difference decreases with increasing the mass flow rate and increases with increasing radiation amount.

    2. CONCLUSIONS

      Experimental measurements taken on evacuated tube collectors with and without reflector are presented here. The efficiency curves at different mass flow rates have been obtained with respect to solar flux for the three configurations. It is observed that the efficiency of the tubular collectors depends on the mass flow rate, incident solar radiation, temperature difference between the inlet and outlet. Out of the three experimental setups here, the evacuated tube with concave reflector is more efficient. The use of the concave reflector diverts the incoming radiation to the focal line where the copper tube is located. That is, more incident energy is concentrating on it and the water in the tube will gets heated up easily. In case of evacuated tube with plain reflector, the reflector cannot concentrate the radiation, as it

      just reflects it. so the increase in the water temperature is found to be less than that of concave type. For the evacuated tube without any reflector, only the incident radiation causes the rise in temperature. Hence the efficiency is much lower. For the radiations obtained on the day of experiment, for a mass flow rate of 36LPH the evacuated tube without reflector shown a variation from 16.47% to 20.05%, while the evacuated tubes with plain and concave reflector shown 19.36% to 26.17% and 25.34% to 27.13% respectively. The experiment is conducted for two different mass flow rates, out of this lower mass flow rate gives higher temperature difference as the water will remain in the tube for more time. So it can be concluded that the efficiency can be further raised if the incident radiation can be more concentrated on the tube.

    3. REFERENCES

  1. E. Zambolin, D. D. Col, Experimental analysis of thermal performance of flat plate and evacuated tube solar colleccollectors in stationary standard and daily conditions, Solar Energy 84 (8) (2010) 13831396

  2. I. Buduhardjo, G. L. Morrisin, Performance of water-inglass evacuated tube solar water heaters, Solar Energy 83 (1) (2009) 4956.

  3. Pei, G.; Li, G.; Zhou, X.; Ji, J.; Su, Y. Comparative Experimental Analysis of the Thermal Performance of Evacuated Tube Solar Water Heater Systems With and Without a Mini-Compound Parabolic Concentrating (CPC) Reflector(C < 1). Energies 2012, 5, 911-924.

  4. W. Weiss, F. Mauthner, Solar heat worldwide. market and contribution to the energy supply 2008, Tech. rep., Solar Heating & Cooling Programme International Energy Agency (2010).

  5. R. Tang, W. Gao, Y. Yu, H. Chen, Optimal tilt-angles of all-glass evacuated tube solar collectors, Energy 34 (2009) 13871395.

  6. Z.D. Cheng, Y.L. He, J. Xiao, Y.B. Tao, R.J. Xu, Three- dimensional numerical study of heat transfer characteristics in the receiver tube of parabolic trough solar collector, International Communications in Heat and Mass Transfer 37 (2010) 782787.

  7. Weidong Huang, Peng Hu, Zeshao Chen, Performance simulation of a parabolic trough solar collector, Solar Energy 86 (2012) 746 755.

  8. Zbysaw Pluta, Evacuated tubular or classical flat plate solar collectors, Journal of Power Technologies 91 (3) (2011) 158164

  9. D.R. Waghole, Dr. G.V.Parishwad, Dr.R.M.Warkhedkar, Dr.N.K.Sane, Dr.V.S.Kulkarni, Heat Transfer analysis of receiver/absorber Tube of Parabolic Trough collector, Proceedings of the 37th National & 4th International Conference on Fluid Mechanics and Fluid Power, December 16-18, 2010, IIT Madras, Chennai, India.

  10. Matthew Roesle, Volkan Coskun, Aldo Steinfeld, Numerical Analysis of Heat Loss from a Parabolic Trough Absorber Tube with Active Vacuum System, Journal of Solar Energy Engineering, August 2011, Vol. 133 / 031015-1.

  11. Jian-Feng Lu and Jing Ding (2011). Heat Transfer Performances and Exergetic Optimization for Solar Heat Receiver, Evaporation, Condensation and Heat transfer, Dr. Amimul Ahsan (Ed.), ISBN: 978-953-307-583-9,InTech

  12. R. Ben Slama, "Experimentation of a plane solar integrated collector storage water heater," in Proc. International Renewable Energy Congress, Sousse Tunisia, November 5-7, pp. 395-403, 20 10.

  13. S.A. Kalogirou, "Solar thermal collectors and applications," Progress in Energy and Combustion Science, Vol. 30, pp. 23 1- 295, 2004

  14. Han Zongwei, Zheng Maoyu, Experimental Research on Solar Assisted Ground Source Heat Pump Heating System with a Latent Heat Storage Tank in Severe Cold Area, Acta Energiae Solaris Sinica, vol 29(5), pp. 574-580, 2008.