- Open Access
- Total Downloads : 542
- Authors : Bharatesh R , B S Sureshchandra
- Paper ID : IJERTV3IS070900
- Volume & Issue : Volume 03, Issue 07 (July 2014)
- Published (First Online): 22-07-2014
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Experimental and Numerical Investigation of Hollow Section With and Without Infill Under Compression and Flexure
Bharatesh R
PG-Student
Civil Engineering Dept
Dr. Ambedkar Institute of Technology Bangalore, India
B S Sureshchandra Associate Professor Civil Engineering Dept
Dr. Ambedkar Institute of Technology Bangalore, India
Abstract A steel-concrete composite column is a compression member, comprising either a concrete encased hot- rolled steel section or a concrete filled tubular section of hot- rolled steel and is generally used as a load-bearing member in a composite framed structure. In the present study, an experiment is conducted on hollow structural steel with and without infill under compression and flexure. The Experiment is carried out on square hollow sections of dimension 75X75X1.6mm. For compression test; short, intermediate and long columns of length 300mm, 360mm, and 400mm are considered respectively. For flexure test, the composite specimen of length 350mm (effective length 310mm) is considered. The infill materials used in the hollow sections are design mix concrete and nofines concrete with chemical bond and mechanical bond. Compression and flexure tests are performed on the specimens and the behavior of the specimens are plotted. The behavior of hollow specimens with and without infill is observed from the experiment and also the effect of bonding between the concrete and steel is obtained. The percentage increase in the strength of hollow section is achieved from the experimental work. The results obtained from the experimental work are compared with numerical study by Finite Element Modeling using ANSYS.
Keywordscomposite section, chemical bond, mechanical bond compression, flexure, FEM.
I.INTRODUCTION
A steel-concrete composite structural member contains both structural steel and concrete elements which work together. There are many combinations between structural steel and concrete. For example, a concrete slab on a steel beam with mechanical shear connectors allows the slab and beam to resist bending moment together. Steel-reinforced concrete column (SRC), comprising a structural steel core surrounded by reinforced concrete, is used when an exposed concrete surface is required and when concrete is to protect the steel core from fire. Steel-concrete composite structures have become a popular choice for building construction due to their efficient and economic use of both steel and concrete construction materials. Most composite structures consist of structural steel frames with steel concrete composite columns to help control lateral drift. These composite columns may be circular or rectangular concrete-filled steel tubes (CFT) or steel shapes encased in reinforced concrete .In a concrete- filled steel tube column (CFT or CFST) the hollow steel tube
is filled with concrete, with or without reinforcing bars. Here, the steel element contributes tensile capacity, provides confinement to concrete elements, and reduces concrete shrinkage while concrete element prevents steel from premature local buckling and fatigue.
Two types of composite columns, those with steel section encased in concrete and those with steel section in-filled with concrete are commonly used in buildings. Basic forms of cross-sections representative of composite columns are Concrete-encased steel composite columns Concrete-filled steel tubular columns
Figure 1- concrete filled steel columns
Figure 2- Encased composite section
A hollow structural section (HSS) is a type of metal profile with a hollow tubular cross section HSS is used as a structural element in buildings, bridges and other structures, and in a wide variety of manufactured products. It's produced in round, square and rectangular shapes in a broad range of sizes and gauges. HSS has many benefits: aesthetic appeal, high strength-to-weight ratios, uniform strength, cost effectiveness and recyclability. HSS is fire resistant and does not warp, twist, split, swell or shrink. It resists dry rot and mildew, termites and carpenter ants. For increased fire resistance, the exterior of the product may be sprayed with a fire retardant material, or boxed in with drywall. The interior can be filled with concrete.
Hollow sections are produced in circular, square and rectangular shapes in broad range of sizes and gauges. Fig shows the typical shapes of cross hollow sections.
Figure 3- shapes of tube sections
-
Finite Element Analysis
The finite element method (FEM) of analysis is a very powerful, modern computational tool. The method has been used to solve very complex structural engineering problems, particularly in the aircraft industry, transient dynamic analysis, buckling analysis, nonlinear structural analysis, contact mechanics, fracture mechanics and composites analysis. It has gained wide acceptance in other disciplines such as thermal analysis, fluid mechanics and
electromagnetics.
II. APPLICATIONS OF COMPOSITE CONSTRUCTION
br , t e
Composite construction has been mainly applied to idges and multistory buildings with he mor traditional forms of composite beams and composite columns. This section will look at the various applications of composite
construction to both bridges and buildings.
A. Bridges
to
Composite construction with bridges allows the designer take full advantage of the steel section in tension by shifting the compression force into the concrete slab in sagging bending. This is made possible through the transfer of longitudinal shear force through traditional headed-stud shear connectors. Headed-stud shear connectors not only provide the transfer of shear force, but also help to assist
lateral stability of the section.
-
Buildings
In steel-framed buildings throughout the world, composite floors are essential in order to achieve an economic structure. This is for quite a few reasons. First, composite slabs allow reduced construction time by eliminating the need for propping and false work in the slab-pouring phase. Furthermore, composite beams are economical, as they reduce the structural depth of the floor and thereby increase the available floors in a given building.
-
Other Structures
In addition to bridges and buildings, composite slab and beam systems have seen considerable application in car park
structures. Steel and steelconcrete composite construction provide a lighter structure with reduced foundation loads.
-
METHODOLOGY
The tests were performed in four series for each of the two tests each series consists of 9 specimens which are further subdivided as short column specimens, intermediate column specimens and long column specimens, consisting of 3 specimens respectively. Series 1 and 2 the specimens are casted with concrete and series 3 is casted with no fines concrete. Each column has cross sectional dimension as 75mmX75mm, and the length of specimens vary as 300mm, 360mm, and 400mm for short, intermediate and long column specimens respectively. the thickness of the hollow section used are 1.6mm. Table 1 and table 2 shows the tabulation of specimens used for compression and flexure tests
Table 1 specification of composite column for compression test
Series number
Concrete type
Bond type
COLUMN TYPE
Abbreviati on used
Series I
Design mix concrete
Mechanica l bond
Short column
RMSC1
RMSC2
RMSC3
Intermedia te column
RMIC1
RMIC2
RMIC3
Long column
RMLC1
RMLC2
RMLC3
Series II
Design mix concrete
Chemical bond
Short column
RCSC1
RCSC2
RCSC3
Intermedia te column
RCIC1
RCIC2
RCIC3
Long column
RCLC1
RCLC2
RCLC3
Series III
No fines concrete
Chemical bond
Short column
NCSC1
NCSC2
NCSC3
intermediat e column
NCIC1
NCIC2
NCIC3
Long column
NCLC1
NCLC2
NCLC3
Series IV
Hollow section
Short column
HSC1
HSC2
HSC3
Intermedia te column
HIC1
HIC2
HIC3
Long column
HLC1
HLC2
HLC3
Table 2 specification of composite beam section
Series number
Concrete type
Bond type
Abbreviation used
Series I
Design mix concrete
Mechanical bond
RMFC1
RMFC2
RMFC3
Series II
Design mix concrete
Chemical bond
RCFC1
RCFC2
RCFC3
Series III
No fines concrete
Chemical bond
NCFC1
NCFC2
NCFC3
Series IV
Hollow section
HFC1
HFC2
HFC3
-
RESULTS AND DISCUSSION
-
Observation on Compression Test
Failure of short column under compression.
The height of the short column used in the experiment was 300mm. Initially the failure of concrete took place in no-fines concrete infill later composite action took place. In composite column yielding of steel is observed at the middle portion. The failure is as shown in the fig 4
Figure 4- failure of composite section under compression
Failure in intermediate column
Majority of the intermediate column failed due to buckling of the column either at the top or at the bottom. Especially in the no fines infill, failure took place at the top of the column, whereas in design mix concrete infill, failure took place at the bottom.
Figure 5- failure of composite section under compression
Failure of long column
Majority of the long column failed due to buckling of the column either at the top or at the bottom was observed. Especially in the no fines infill, failure took place at the top of the column, whereas in design mix concrete infill, failure took place at the bottom. In comparison with design mix concrete, nofines concrete infill showed maximum bending.
Figure 6- failure of composite section under compression
-
Observation on Flexure Test
The flexure test is performed in the universal testing machine by applying concentrated load at the center of the specimen. The failure of the flexural member took place at the bottom layer with formation of crack as shown in the fig 7
Figure 7- failure of composite beam section
-
Load Deflection Relationship of Compression Test.
The load- axial deformation curves for all the series are obtained. The variation for concrete filled short column specimens is shown in fig 8.
Figure 8 load – deformation curve for composite section
-
Load Deflection Relationship of Flexure Test.
The load deformation curve for flexure is as shown in fig
9
Figure 9 load deformation curve for composite section
The comparison of the hollow sections with and without infill is shown in the fig 10
Figure 10- comparison of sections with and without infill
The ultimate load and deformation of the series of specimens used are tabulated as shown in the table
Table 3 summary of flexure test results
Infill type
Bonding type
Beam specificatio n
Ultimat e load (in kN)
Maximum deformatio
n (in mm)
Hollow
HFC1
15
8.59
HFC2
14
9.3
HFC3
14
9.08
Concret e
Chemical bonding
RCFC1
70
11.29
RCFC2
75
6.4
RCFC3
75
13.4
Concret e
Mechanica l bonding
RMFC1
76
24
RMFC2
70
17
RMFC3
70
9
Nofines
Chemical bonding
NCFC1
35
20
NCFC2
35
26.82
NCFC3
30
10.8
Infill type
Bonding type
Column specifications
Ultim ate load (in
kN)
Maximum axial deformatio n (in mm)
Hollow
Short column
HSC1
104
1.25
HSC2
106
1.1
HSC3
106
2.25
Intermedia te column
HIC1
96
1.22
HIC2
96
1.1
HIC3
82
1.9
Long column
HLC1
80
1.09
HLC2
102
1.35
HLC3
100
1.4
Concrete infill
Chemic- al bonding
Short column
RCSC1
274
13.7
RCSC2
212
20.95
RCSC3
236
19.47
Intermedia te column
RCIC1
28.17
RCIC2
300
21.64
RCIC3
284
22.85
Long column
RCLC1
262
14.95
RCLC2
260
12.61
RCLC3
244
10.02
Concrete infill
Mechani- cal bonding
Short column
RMSC1
162
5
RMSC2
214
4.8
RMSC3
192
6.6
Intermedia te column
RMIC1
146
5.15
RMIC2
172
3.96
RMIC3
156
3.85
Long column
RMLC1
206
12.3
RMLC2
216
28.58
RMLC3
206
24.03
Nofines
Chemic- al bonding
Short column
NCSC1
140
7
NCSC2
140
8.3
NCSC3
130
6.6
Intermedia te column
NCIC1
125
12.5
NCIC2
110
12.5
NCIC3
145
8.95
Long column
NCLC1
116
14.1
NCLC2
120
9.53
NCLC3
118
11.45
Table 4 summary of compression test results
The above experimental results are compared with the numerical analysis. The FEM model of the specimen subjected to compression and flexure are shown in figure 11 and figure 12.
-
-
CONCLUSIONS
-
In the present study following conclusions are derived
-
The strength of the hollow section with infill were observed to be greater than the hollow section without infill in compression as well as in flexure.
-
Among the composite sections used the design mix concrete composite sections were shown better results than other forms of composite section.
-
The percentage increase in the compressive strength of the composite columns are as shown
-
composite columns with chemical bonding – 60 to
70%.
-
composite columns with mechanical bonding – 50
to 60%
-
hollow columns with no fines concrete – 15 to
Figure 11 Model of composite section subjected to compression
Figure 12 Model of composite section subjected to flexure
The numerical analysis in comparison with experimental results shows similar variations. The plot of numerical and experimental result is shown in figure 13.
Figure 13 Comparison of experimental and FEA results under flexure
25%
-
-
The percentage increase in the flexural strength are as shown below.
-
Composite section with chemical bonding and mechanical bonding – 80%
-
hollow columns with no fines concrete – 57%
-
-
The above experimental results are compared with the numerical analysis of composite section. The results are compared for composite column section (RCIC) and composite beam section (RCFC).In comparison with the experimental results the numerical study shows similar variation.
-
There is an enhancement of ultimate load carrying capacity of specimen in numerical method than that of experimental results. It shows a deviation of 12% from experimental results for compression and the deviation under flexure is observed to be 15%.
REFERENCES
-
K. Chithira and K. Baskar "Experimental and Numerical Investigation on Circular CFT Columns under Eccentric Load Condition with and without Shear Connectors" International Journal of Earth Sciences and EngineeringISSN 0974-5904, Vol. 05, No. 01, February 2012, pp. 169- 179 (2012)
-
Shehdeh Ghannam "Buckling of Concrete-Filled Steel Tubular Slender Columns"
-
E. K. Mohanraj, Perundurai Dr. S. Kandasamy "Experimental Behavior of Axially Loaded Slender Hollow Steel Columns in-filled with Rubber Concrete" (2007)
-
Anil Kumar Patidar" Behaviour of Concrete Filled Rectangular Steel Tube Column " IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684 Volume 4, Issue 2 (Nov. – Dec. 2012), PP 46-52 (2012)
-
N.E. Shanmugam, B. Lakshmi "State of the art report on steelconcrete
composite columns" Journal of Constructional Steel Research 57 (2001) 1041 1080 (2001)
-
Lin-Hai Han "Flexural behaviour of concrete-filled steel tubes" Journal of Constructional Steel Research 60 (2004) 313337
-
E. M. Lui "Structural Steel Design" 1999 by CRC Press LLC
-
Brian Uy, J.Y. Richard Liew "Composite SteelConcrete Structures" 2003 by CRC Press LLC