Illumination Control using MEMS based Detection

DOI : 10.17577/IJERTV5IS020080

Download Full-Text PDF Cite this Publication

Text Only Version

Illumination Control using MEMS based Detection

Masood Anzar, Tarun Rajvanshi*, Tanvi Aggarwal*, Megha Sharma* (*Students)

Department of EIE,

Meerut Institute of Engineering & Technology, Meerut

Abstract-In this paper we propose a design using both a microprocessor and light sensors for automatic room light detection and control. Our design, the LIC (light intensity controller) which will be installed in every light fixture of a family, is made up of three: Omron d6t thermal sensor, Luxmeter, 8051 microprocessor and Omron thermal sensor is used as a detector of human presence under the field of view (FOV). Luxmeter is used as an intensity monitor so as to regulate the illumination at the desired level. The illumination in the region of interest/room is proportional to the power consumption in lamps. The idea is to reduce the illumination level depending on the environmental conditions and occupancy in the home so as to minimize the power consumption.

Keyword: Light Intensity Controller (LIC), Microcontroller Unit (MCU), Energy Management System, Home Power Saving.

  1. INTRODUCTION

    In recent years the energy crisis has become one problem which the whole world must confront. Home power consumption makes up the largest part of energy consumption in the world. In the particular, the power consumption of lamp in a typical home is a factor which can't be ignored. The typical user needs different light intensities in different places. Sometimes the light intensities from outside is sufficient for the user, and thus we don't need to turn on any light. But sometimes the user leaves and forgot to turn off the light. These factors cause energy waste. Therefore some power management of light control in a home is necessary in order to save energy.

    Lights are usually controlled by On\Off switches. Of course, the user can switch a light on or off remotely by connecting a specific device to a PC, but there has to be at least a PC, for the control mechanism. Moreover, this inconvenient practice comes at a high cost for users. In some design one must install specific hardware and software to control the lights, resulting in unacceptable cost. Furthermore this type of system cannot detect either the temperature of human body or the room light intensity.

    In this paper we purpose a design for automatic room light detection and control. We install a low power light intensity controller (LIC) in every setup area of a home. The design detects the person presence in the detection area by means of MEMS based Omron Thermal Sensor (d6t) in the LIC unit. The unit also detects and controls the variation of the light intensity in a room from the desired level.

    The paper is organized as follow. Section I comprises of a complete introduction and scope of the proposed work. Section II covers the description of the proposed work area describing the illumination requirement according to the room dimensions. Light Illumination Control Unit (LIC) is described in section III. Outcomes and achievements are discussed in section IV. Section V covers the conclusion and future scope of work.

  2. PROPOSED WORK AREA

    The proposed energy management system can be applied to any building type, including offices, shopping malls, homes, shops, dining halls, conference rooms, etc. In our problem, we have worked on home power management. For this we have considered a house of basically three sections including bedroom, living room, dining area, study table. Each section is measured and the system is applied as follows:

    Fig 1: Proposed Area of Work

    Area

    Watts

    No of Bulbs

    Total Wattage

    Bedroom

    12

    4

    48

    Kitchen

    12

    2

    24

    Sitting Area

    12

    2

    24

    12

    1

    12

    Dining Area

    12

    2

    24

    Study Room

    12

    1

    12

    12

    4

    48

    Total Wattage

    192

    Table 1: Illumination Load of the Proposed Area

    A bedroom of 13 1 x 7 is considered and four lights are considered across each corner of the room of 60 W each. A 7 7 x 6 9 wide kitchen is taken with two lamps of 60 W each. Similarly, living room of 12 9 x 11 is taken to be comprised of a dining area, study room and sitting area. Four Lamps are used in the sitting area of 60W each with a central designer light of 100W. Dining area is taken to be illuminated by two lamps of 40W each covering 3 persons each on a dining table. A study room is also considered with a 40W lamp light and 100W room light. The total illumination load of the house is 920 Watts if all the lights are switched ON after the sunset.

    This causes large power consumption during the day.

    The proposed power management system is capable of power saving by monitoring the illumination level in each area. The system calculates the illumination level as per the requirement in each sub area and adjusts the illumination level as per requirement. Various cases/conditions have been taken as per living conditions.

  3. LIGHT INTENSITY CONTROL UNIT

    The proposed LIC is designed to minimize the daily illumination load by adjusting the illumination level as per the requirement and working conditions. The system is made up of the presence sensor, occupancy sensor, light sensor circuit, light controller unit, and the low power MCU. We also provide a DC power supply from AC power to every component.

    Omron Thermal Sensor is used as an occupancy sensor to detect the presence of a person in the working sub-area.

    Fig 2: Circuit Diagram of LIC

    The proposed work area is a home with living room and bedroom. We have considered three sub-work areas in living room including dining table area, television area and study table area.

    Time Slot

    Day/Night Activity

    Area of Illumination

    Power Consumption without LIC

    Power consumption with LIC

    Power Saving

    No of Lamps

    Watt

    Total Watt

    No of Lamps

    Watt

    Total Watt

    (Watts)

    6am-7am

    Reading Newspaper

    Sitting Area

    2

    12

    24

    2

    3

    6

    18

    6am-7am

    Study

    Study Area

    2

    12

    24

    2

    6

    12

    12

    7am-8am

    Breakfast Preparation

    Kitchen

    2

    12

    24

    2

    3

    6

    18

    7 am -8 am

    Breakfast

    Dining Area

    3

    12

    36

    3

    8

    24

    12

    8 am -11 am

    Household Work

    Living Area

    1

    12

    36

    1

    3

    9

    27

    11am-12pm

    Watching TV

    Living Area

    1

    12

    24

    1

    3

    6

    18

    12 pm-1 pm

    Lunch Preparation

    Kitchen

    2

    12

    24

    2

    3

    6

    18

    1pm-2pm

    Lunch

    Dining area

    3

    12

    36

    3

    6

    18

    18

    2pm-3pm

    Entertainment

    Living Area

    1

    12

    12

    2

    3

    6

    6

    3pm-5pm

    Evening Rest

    Bedroom

    2

    12

    48

    2

    6

    24

    24

    5pm-6pm

    Refreshment

    Living Area

    2

    12

    24

    2

    4

    8

    16

    6pm-7pm

    Study

    Study Room

    2

    12

    24

    2

    6

    12

    12

    7pm-8pm

    Dinner Preparation

    Kitchen

    2

    12

    24

    2

    6

    12

    12

    8pm-8.30pm

    Dinner

    Dining area

    3

    12

    18

    3

    8

    12

    6

    8.30pm-10.00pm

    Watching TV

    Living Area

    2

    12

    36

    2

    8

    24

    12

    10pm-11pm

    Study

    Study Room

    4

    12

    96

    4

    6

    48

    48

    11pm-6am

    Sleep

    Bedroom

    1

    12

    84

    1

    6

    42

    42

    Average Saving in a day

    594

    275

    319

    Average saving in a month

    17820

    8250

    9570

    Table 2: Average Load Chart

    1. Presence Detector

      We have taken much care for the power consumption even in the controller circuitry. An IR sensor circuit at the entrance is used to detect the presence of a person in the house. Thus, it will act as an enable signal for the LIC control circuitry. LIC put all the light OFF when there is no person in the house.

      The moment person enters the house LIC gets triggered by presence detector and starts monitoring the illumination level of the house according to the designed requirements.

      IR presence detector also acts as an automatic switching in case if the person leaves the area while keeping the lights ON.

      Omrons non-contact temperature sensor can solve the shortcomings of a conventional pyroelectric sensor, which cannot catch the signal of a stationary person because the sensor detects the change of signal. Moreover, Omrons non- contact temperature sensor keeps detecting the far-infrared ray of an object, while the pyroelectric models do not.

      The sensor is connected as per the connection shown in figure (5),

      The system is capable to turn it OFF automatically, thereby reducing the power consumption level in no requirement condition.

    2. Occupancy Detector

      The idea is to illuminate the area only when it senses the person under the sensor area. We have taken MEMS based thermal sensor as a presence detector.

      Fig 3: Omron Thermal Sensor

      Omron D6T-8L is made up of a cap with silicon lens, MEMS thermopile sensor chips, and dedicated analog circuit and a logic circuit for converting to a digital temperature value on a single board through one connector.

      Fig 4: Detection of Poly-electric and Omron Sensor

      Fig 5: Interfacing of D6T with MUC

    3. Microcontroller Unit

    We have used 8051 microcontroller as a logic controller which regulates the condition of the system

    Working Area

    Minimum Illumination (LUX)

    Maximum Illumination (LUX)

    Bedroom

    200

    500

    Kitchen

    300

    500

    Sitting Area

    150

    300

    Dining Area

    150

    300

    Study Room

    500

    1000

    Table 3: Illumination Range in each area

    Figure 6 : PIN diagram of MCU

    Fig 7: Flowchart of the Strategy

    Large area is divided into sub areas. If the sensor does not find any person in the sub area for 5 minutes, then MCU sets the command for minimum illumination of 80 LUX.

    Luxmeter implanted at the sub area detects the illumination level. The Luxmeter value is then compared with the reference value adjusted by a variable resistance (R) in figure 8 connected with the inverting terminal. The control signal is obtained at terminal 6 which is used to feed the intensity controller for illumination correction. The variable resistance

    (R) provided at the panel of the main unison that the user can adjust the required illumination as per his/her requirement. Thus, it makes it a generalized user friendly control circuit.

    e) Intensity Controller

    Intensity controller is that part of LIC which is responsible to provide variable power supply for to the load/lamp for illumination balance.

    Fig 9: Circuit of Intensity Controller

    Each work area is made to set for a reference illumination level. Various levels of illumination are taken in the proposed strategy for each sub-area of the house. Table x clearly define the reference illumination range for each sub- area.

    The flowchart shown in Fig 7 clearly describes the assumed condition for our test area/ home.

    The system is also made to set at sleep mode during 11pm – 6am. In this mode, all lights (except bedroom night lamp) are set to get turned off irrespective of any required reference illumination value. Manual switching is also possible as per convenience of the user.

    d) Intensity Detector

    In order to keep the illumination at the reference level, flux- meter constantly monitors the illumination in each area.

    Fig 8: Circuit Diagram of Intensity Detector

    Fig 10: Pin Diagram of TRIAC voltage controller

    It is provided with two input signal featuring control signal from intensity detector and enable signal from MCU. Both the signals are logically AND before feeding the phase controlled ac voltage controller.

    Variable voltage supply at the load/lamp is provided with TRIAC phase angle controller. TDA1185A is used for the above requirement. It provides variable voltage for different value of control signal.

  4. OUTCOMES

    The proposed scheme find it useful in regulating the excessive power consumption. The scheme is tested with the simulation of the scheme setup. Luxmeter is installed in the house and its illumination values are measured in each target room. The average hourly data of complete one month is analysed initially. The hourly data is then passes to the signal conditioner so as to minimise the disturbances. We have then appled it to the LIC simlation and the power saving is calculated on hourly basis.

    Office

    Conference Reception room

    200-750 lux

    Clerical Work

    700-1500 lux

    Typing Drafting

    1000-2000 lux

    Factory

    Packing Place Entrance

    150-300 lux

    Visual Work at Production line

    300-750 lux

    Inspection Work

    750-1500 lux

    Electronic parts Assembly Line

    1500-3000 lux

    Hotel

    Public room, Cloak Room

    100-200 lux

    Reception , Cashier

    220-1000 lux

    Store

    Indoors Stairs Corridor

    150-200 lux

    Show window, Packing table

    750-1500 lux

    Forefront of Show Window

    1500-3000 lux

    Hospital

    Sick Room, Ware house

    100-200 lux

    Medical Examination Room

    300-750 lux

    Operation Room , Emergency

    750-1500 lux

    School

    Auditorium

    100-300 lux

    Classroom

    200-750 lux

    Laboratory, Library, Drafting Room

    500-1500 lux

    Fig 10: Average hourly plot for power consumption in light

    It is to be noted from the plot that LIC is capable of saving the illumination power at each hour.

    Various illumination controller is proposed by many researchers. The work finds it useful in detecting the stationary person which other strategy fails as it sense the person movement for illumination control.

    The controller logic differ from other previous schemes as they worked on regulating the switching of lamps only. The proposed scheme provide fine illumiination control thereby varying the applied voltage. Thus, it is highly precise controller which constantly regulate the illumination level at each stage.

  5. CONCLUSION AND FUTURE SCOPE

    The system seems to be quite beneficial for the minimization of power consumption. It can be installed not only in hose but also in the following places as stated in table

    4. If universally adopted, such a system finds it extremely useful for the minimization of electric power consumption; thereby reducing the electricity bill up to 50%. The work can also be extended as a security system also. The presence sensor can detect the uninvited person in the area and can provide an alarming signal for unauthorized entry. A check can also be made for the fire. If the illumination and heat sensed by the Luxmeter and thermal sensor exceed the required level, the system can be used to provide alert for fire.

    Table 4: Illumination Range in other areas

  6. REFERENCES

  1. Changseok Bae, Jinho Yoo, Kyuchang Kang, Yoonsik Choe, and Jeunwoo Lee, Home server for home digital service environments, IEEE International Conference on Consumer Electronics, 2003, Vol 49, pp. 1129-1135, Nov. 2003.

  2. A. Z. Alkar, and U. Buhur, An Internet Based Wireless Home Automation System for Multifunctional Devices, IEEE Transactions on Consumer Electronics, Vol. 51, pp. 1169-1174, Nov. 2005.

  3. Yu-Ping Tsou, Jun-Wei Hsieh, Cheng-Ting Lin, and Chun-Yu Chen, Building a Remote Supervisory Control Network System for Smart Home Applications, IEEE International Conference on Systems, Man and Cybernetics, 2006, ICSMC '06, Vol. 3, pp.1826-1830, Oct. 2006.

  4. A. R. Al-Ali and M. Al-Rousan, Java-based home automation system, IEEE Transactions on Consumer Electronics, Vol. 50, Issue 2, pp.498-504, May 2004.

  5. Chia-Hung Lien, Chi-Hsiung Lin, Ying-Wen Bai, Ming-Fong Liu, and Ming-Bo Lin, Remotely Controllable Outlet System for Home Power Management, IEEE Tenth International Symposium on Consumer Electronics, 2006, ISCE/ 2006, pp. 7-12, June 28-July 1, 2006.

  6. A. Alheraish, Design and implementation of home automation system, IEEE Transactions on Consumer Electronics, Vol. 50, pp.1087-1092, Nov. 2004.

Leave a Reply