Independent Control of Two Three Phase Motors using Z-Source Five Leg Inverter

DOI : 10.17577/IJERTV3IS030836

Download Full-Text PDF Cite this Publication

Text Only Version

Independent Control of Two Three Phase Motors using Z-Source Five Leg Inverter

M. Arunachalam, P. Kumaresan, S. Jayaprakash

Sathyabama University,Chennai,Tamilnadu,India.

Abstract This paper presents Z-source Five Leg Inverter(ZFLI) design and its simulation result. This inverter consists of two main parts. The first part having impedance network and second part having eight switching devices and two capacitors. It can independently control two three phase motors using pulse width modulation. The number of switches used in this inverter is less than the required in Voltage-Source Inverters (VSI). In Five Leg Inverter, since the DC voltage source is shared between the two loads, the voltage across each load is less than in the case of a VSI. Therefore, a larger DC voltage source needs to be used in this method which increases system cost and size. In this paper this is improved by using Z-source structure. This inverter uses shoot through mode so both the upper and lower devices of any one leg (i.e., both devices are gated on), any two legs, any three leg or all four legs will short together. This shoot- through state provides the unique buck-boost feature to the inverter. Capacitors in the switching network act as switch during zero state operation.

  1. INTRODUCTION

    Normally AC motors are driven with three leg inverter. But two motor cannot control independently with three leg inverter, for that operation two inverter is required. To improve and simplify the control system for the independent control of two three-phase loads, some other methods have been proposed such as the FLI and NSI which consist of ten and nine switches, respectively, less than the required number of switches in Voltage-Source Inverters (VSI). This inverter (ZFLI) is a improved version of FLI, it uses only eight switches.

    The impedance source or Z-source inverters are special types of inverters that provide the voltage boost capability in conventional inverters. The conventional inverters work as a buck converter only, because the output voltage is always lower than the DC input voltage. Moreover, the upper and lower power switch cannot conduct simultaneously, otherwise the DC source will short circuit. Hence, a dead band is provided intentionally between the switching on and switching off of the complimentary power switches of the same leg. This dead band causes distortion in the output current. These shortcomings are overcome in the Z source inverter.

  2. STRUCTURE OF ZFLI

    Fig1. Z-source FLI

    The Fig1. Shows the Z source five leg inverter. Impedance network consists of two equal inductors (L1, L2) and two equal capacitors (C1, C2). The network inductors are connected in series arms and capacitors are connected in diagonal arms. The main inverter circuit consists of five legs. In this four legs are having switching devices and fifth leg is having capacitors. The u and v phases of motor1 are connected in a leg1 and a leg2 respectively, those of a motor 2 is connected in a leg3 and a leg4 and w phase of the both motors are connected in the neutral point of the two sprit capacitor.

    The Impedance Network can either buck or boost the input voltage depending upon the boosting factor. This network is also used as a second order filter. This network requires smaller value of inductances and capacitances. This network is coupled between the source and main inverter circuit. The source can be battery, diode rectifier, thyristor converter, and inductor, capacitor or combination of those.

  3. OPERATION & CONTROL OF ZFLI

    The unique feature of the Z-source inverter is that the output ac voltage can be any value between zero and infinity regard- less of the input dc voltage. That is, the Z-source inverter is a buckboost inverter that has a wide range of obtainable voltage. The traditional V- and I-source inverters cannot provide such feature. The three-phase Z-source inverter bridge has three states of operation unlike the traditional three-phase V-source inverter that has two state . The traditional three- phase V-source inverter has active state when the dc voltage is impressed across the load and zero state when the load terminals are shorted through either the lower or upper three devices, respectively.

    However, the three-phase Z-source inverter bridge has one extra shoot through state when the load terminals are shorted through both the upper and lower devices of any one leg (i.e., both devices are gated on), any two legs, any three leg or all four legs. This shoot-through state is forbidden in the traditional V-source inverter, because it would cause a shoot- through. The Z-source network makes the shoot-through state possible. This shoot-through state provides the unique buck- boost feature to the inverter. .

    Fig2. Equivalent circuit of Z-source inverter

    The Fig2. Shows the equivalent circuit of the Z-source inverter when viewed from the dc link.

    Fig3. Z-source inverter-Shoot through state

    The Fig3 shows, the inverter bridge is equivalent to a short circuit when the inverter is in the shoot-through state.

    Fig4. Z-source inverter-Non Shoot through state

    The Fig4. Shows, the inverter bridge becomes an equivalent current source during non shoot through state.

    All the traditional pulse width-modulation (PWM) schemes can be used to control the Z- source inverter and their theoretical inputoutput relationships still hold. The traditional

    enough to generate the desired ac voltage, the traditional PWM is used.

    While the dc voltage is not enough to directly generate a desired output voltage, a modified PWM with shoot-through states will be used to boost voltage. It should be noted that each phase leg still switches on and off once per switching cycle. Without change the total time interval, shoot-through states are evenly allocated into each phase. That is, the active states are unchanged. However, the equivalent dc-link voltage to the inverter is boosted because of the shoot-through states. During zero state, the load terminals are shorted through either the lower or upper two devices. When two lower switches are shorted the upper capacitor act as switch and half of the dc link voltage will fed to motor and when two upper switches are shorted the lower capacitor act as switch and half of the dc link voltage will fed to motor respectively

  4. DESIGN OF IMPEDANCE NETWORK

    For the traditional V-source inverter, the dc capacitor is the sole energy storage and filtering element to suppress voltage ripple and serve temporary storage. For the traditional I-source inverter, the dc inductor is the sole energy storage/filtering element to suppress current ripple and serve temporary storage.

    The Z-source network is a combination of two inductors and two capacitors. This combined circuit, the Z-source network is the energy storage/filtering element for the Z-source inverter. The Z-source network provides a second-order filter and is more effective to suppress voltage and current ripples than capacitor or inductor used alone in the traditional inverters. Therefore, the inductor and capacitor requirement should be smaller than the traditional inverters.

    Fig5. Equivalent circuit of Impedance network

    Fig5. Shows the impedance network is redrawn as bridge circuit for calculation purpose.

    Now assume I2=0, the current I1enters the bridge at point 1 and divides equally between the two arms of the bridge. Using Kirchhoffs law,

    PWM switching sequence based on the triangular carrier method. In every switching cycle, the two non shoot through states are used along with twoadjacent active states to synthesize the desired voltage. When the dc voltage is high

    I L V I1 1 2 2 2C

    – (1)

    V2

    I1 I L

    2C 1 2

    – (2)

    6. SIMULATION RESULT

    V I1 [ 1 L]

    2 2 C

    – (3)

    To verify the validity of the methods, various simulations are performed. The simulation parameters are given Table1. In order to show that the Z source FLI is able to control each motor independently, the two similar rating motors are

  5. MODULATION TECHNIQUE USED IN ZFLI

    Simple Boost PWM of the Z-source FLI in fig6. In method, four line signals are produced as the reference signals. Now, for a Z-source inverter modulation, additional shoot-through states need to be added to the control circuit. In simple-boost PWM method, like the conventional PWM, the switching signals are generated by comparing four reference waves with the carrier wave. The only difference is that this method

    operated at different speed.

    DC voltage source

    220 V

    Carrier signal

    1KHz

    Motor 1

    0.37kW,400V,50Hz,

    750 rpm

    Motor 2

    0.37kW,400V,50Hz,

    750 rpm

    Z source capacitor

    1000µf

    Z source inductor

    160µH

    Sprit capacitors

    5000µf

    Table 1. Parameters of simulation

    utilizes two constant envelope signals V1

    circuit states.

    and V2

    for short

    These constant envelope signals are equal to or greater than the maximum value of the sinusoidal reference signals. When

    a triangular high frequency carrier signal is greater than V2 or

    is smaller than V1 , all switches are turned on and the circuit turns into shoot through state as illustrated in Fig. 6. In this method, boost factor can be written as:

    T

    Fig 7 to 14 shows the simulation result for simple boost

    1

    1

    0 1V1 T

    B 1

    1 2 T0

    T

    2V 1

    – (4)

    – (5)

    modulation method. In this figure, with DC input voltage is equal to 220V, DC voltage of Z source network is boosted to a value nearly equal to 250V. In this method DC link voltage is unstable. The reason is that here two envelope signals are producing short circuit signal for each load. This causes the short circuit time to increase.

    Fig6. Simple Boost modulation

    The Fig 6 shows gate signals for switches in one leg using simple boost PWM. It has sine wave as reference signal, triangular wave as carrier signal and two envelope signal for shoot through mode.

    From above equation it is observed that by decreasing V1 , the value of B can be increased. However, it should be noted that V1 cannot be smaller than M otherwise it would interfere with a reference wave and convert an active vector to a zero vector.

    Fig 7 .Motor1&2 speed

    Fig 7 shows the motor1 and 2 running at speed of 750 rpm and 520 rpm respectively.

    Fig 8 .Motor1voltage

    Fig8. shows the voltage wave form for motor1 and voltages are 240/120/120V.

    Fig 9 .Motor1 current

    Fig9. shows the current wave form for motor 1 and currents are 2/2/2Amps.

    Fig 10. Motor 2 voltage

    Fig10. shows the voltage wave form for motor2 and voltages are 250/125/125V.

    Fig 11. Motor2 current

    Fig11. shows the current wave form for motor 2 and currents are 2/2/2Amps.

    Fig 12. DC voltage

    Fig12. shows the DC source voltage of 220V and DC link voltage is varying from 190V to 245V,due buck-boost operation.

    Fig 13 .PWM signal for Motor1

    Fig13.shows gate pulse signals of switch S11, S21, S12 & S22 for motor1

    Fig 14. PWM signal for Motor2

    Fig14.shows gate pulse signal of switch S13, S23, S14 & S24 for motor2.

    Fig 15. Simulation circuit for Inverter

    Fig15.shows simulation circuit of ZFLI with DC source, Z network, five leg inverter with eight switches & two capacitors and two similar rated three phase induction motors.

    Fig 16. Simulation circuit for PWM

    Fig16.shows simple boost pulse width modulation circuit. This circuit generates gate pulse signal for switches in the inverter.

  6. CONCLUSION

In this paper, Z source five leg inverter operation, simulation and design are explained and proved that it can be control two motors independently at different speed. This inverter can use Battery or fuel cell or solar cell or rectifier circuit as DC source. This inverter used less number of switches than other conventional inverter so cost is saved and size of the main and control system are reduced. This also reduces the inverter losses and increases the efficiency. This inverter can operate for wide speed range with proper selection of inductor and capacitor value in the circuit. Energy saved in the impedance network is utilized to circuit. For more stable operation of the inverter, feedback circuit can be introduced.

REFERENCE

1 .Z-Source Five Leg Inverter by A.R. Barati, M. Moslehi, D. Arab Khaburi Electr. Eng. Dept., Iran University. of Sci. & Techno., Tehran, Iran

  1. Z-Source Inverter for Motor Drives by Fang Zheng Peng, Fellow, IEEE, Alan Joseph, JinWang, Student Member, IEEE, Miaosen Shen, Student Member, IEEE, Lihua Chen, Zhiguo Pan, Student Member, IEEE, Eduardo Ortiz-Rivera, Member, IEEE, and Yi Huang

  2. Z-Source Inverter by Fang Zheng Peng, Senior Member, IEEE

  3. Comparison of Performance Characteristics of Five-Leg and Four-Leg Inverters Fed to Two Different Induction Motor Drives by Mr.B.Ravi and Mr.E.Narasimhulu

  4. M. N. Uddin, T. S. Radwan, and M. A. Rahman,Fuzzy-logic- controllerbased cost-effective four-switch three-phase inverter-fed IPM synchronous motor drive system, IEEE Trans. Ind. Appl., vol. 42, no. 1, pp.438444, Jan./Feb. 2006.

  5. Y. Kimura, M. Hizume, K. Oka, and K. Matsuse,Independent vector control of two induction motors with five-leg inverter by the expanded two arm PWM method, in Proc. IEEJ Int. Power Electron. Conf., 2005, pp. 613616.

  6. M.H.Rashid , Power electronics, 2nd ed. Englewood cliffs, PH,1993

8 .B.K.Bose, Power electronics and variable frequency drives, Upper saddle river, PH,2002

  1. F.Z.Pemg. M.Shen and Z.Qian , Maximum boost control of Z source inverter ,IEEE Trans Power electro, vol.20, no4, pp833-838, jul-2005

  2. Kazuo oka, Kouki Matsuse, PWM technique of five leg inverter applying two arm modulation, pp811-816

M.Arunachalam has completed Diploma in Electrical and Electronics Engineering,

Government Polytechnic, Tuticorin in 1999.He is working in DAE, Kalpakkam.

P.Kumaresan has completed Electrician in Government Industrial Training Institute, Thiruvannamalai and Diploma in Electrical and Electronics Engineering, Central Polytechnic, Chennai in 1999. He is working in DAE, Kalpakkam.

S.Jayaprakash has completed Diploma in Electrical and Electronics Engineering, DOTE, Chennai, in 1996.B.E. Degree in Electrical and Electronics from the Madras University in 1999 and M.E.Degree in Power Electronics and Industrial Drives from Sathyabama University in 2007.He is a life member of Indian Society for Technical Education. Presently he is pursuing Ph.D. programme at Sathyabama University, Chennai, India. His research interests include Power Electronic Converters, PWM Technique in Power

Electronics and other related topics.