- Open Access
- Total Downloads : 3
- Authors : Gulshan Kumar, Arvind Kumar, Jitender Kumar, Shiv Singh, Vivek Walia
- Paper ID : IJERTCONV1IS05015
- Volume & Issue : MAM – 2013 (Volume 1 – Issue 05)
- Published (First Online): 30-07-2018
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Indoor radon measurement in the some houses of Mandi district Himachal Pradesh, India using solid state nuclear track detectors.
Gulshan Kumara*, Arvind Kumarb, Jitender Kumara, Shiv Singha, Vivek Waliab aArni School of Basic Sciences, Department of Physics, Arni University Indora, Kangra,
India-176401
bNational Center for Research on Earthquake Engineering, NARL, Taipei 106, Taiwan
*Corresponding author: Tel. No.+91-9418195031
E-mail address: goldy_physics@rediffmail.com (G. Kumar)
Abstract
Radon is the most important source of natural radiation and exposure to radon (222 Rn) can result in a significant inhalation risk to population particularly to those living in homes. Because of this, the monitoring of the indoor radon levels in the different geographic areas is important where human activities are developed. In the present study indoor radon levels have been measured in some houses of Mandi district Himachal Pradesh, India using solid state nuclear track detectors (SSNTDs) commercially known as LR – 115 type II. Forty (40) indoor radon detectors were placed in the various houses for three months (i.e. From April 2012 to July 2012) in the study area. Indoor radon concentration in the study area found to be varies from 42.22 Bq/m3 to 398.3Bq/m3 with the average value of 138 Bq/m3 which are higher than the world average of 40 Bqm-3 and are below the recommended action level (200- 600 Bq m-3).
Key Words: Radon, SSNTDs, Alpha Particle, LR- 115 type-II.
-
Introduction:
The measurement of radon in mans environment is of interest because of its alpha emitting nature. Many environmental pollutants are classified as cancer- causing solely on the basis of laboratory studies using either animals or cell cultures. In the case of radon, there is direct evidence from human studies of a link between exposure to radon and lung cancer. Most of our time is spent indoors; therefore, the measurement and evaluation of radon concentrations in buildings are important. Radon is a naturally occurring odourless, colorless, tasteless inert gas which is imperceptible to our senses. It is produced
continuously from the decay of naturally occurring radionuclide such as 238U, 235U and 232Th.The radioisotope 222Rn, produced from the decay of 238U, is the main source (approximately 55%) of internal radiation exposure to human life [1]. Worldwide average annual effective dose from ionizing radiation from natural sources is estimated to be 2.4 mSv, of which about 1.0 mSv is due to radon exposure [2]. The numerous measurements of the activity concentrations of radon in different countries along with epidemiological studies regarding the indoor radon and risk of lung cancer have been published in recent years [3,4,5]. The main natural sources of indoor radon are soil, building materials (sand, rocks, cement, etc.,), tap water, natural energy sources used for cooking like (gas, coal, etc.,) which contain traces of 238U, the topography of the area, house construction type, soil characteristics, ventilation rate, wind direction, atmospheric pressure and even the lifestyle of people. The Solid State Nuclear Track Detectors (SSNTDs) are an important tool in investigations concerning the presence of radon gas [6, 7]. Solid State Nuclear Track Detectors (SSNTDs) are insulating solids both naturally occurring and man-made. In the present study, Solid State Nuclear Track Detectors (SSNTDs) technique has been utilized for the study of indoor radon level in the some houses of Mandi district Himachal Pradesh.
-
Material and methods:
The indoor radon level was measured in forty houses between the MCT and MBT in the Mandi district of Himachal Pradesh using the LR-115 type II (SSNTDs). The houses were selected at randomly situated in different areas, at a few kms away from each other. For this purpose the LR film was cut into pieces of size 1.5cm x 1.5cm and was placed on the
cardboard such that the sensitive portion of the film was exposed to the air (fig. 1). These detectors were placed at about the 2m height from the ground, so that they were capable of recording the alpha- particles resulting from the decay of radon in the room. After exposure to standard durations of 90 days, the detectors were subjected to chemical processing in a 10 M analytical grade sodium hydroxide solution at (60 ±1)ºC, for 90 min, in a constant temperature water bath to enlarge the latent tracks produced by alpha particles from the decay of radon. After the etching, the detectors were washed for 30 minutes with running cold water, then with distilled water and finally with a 50% water/alcohol solution. After a few minutes of drying in the air, the detector becomes ready for track counting. The etched tracks were counted using an optical microscope (Zeiss at 400× magnification). The recorded tracks recorded on the films were converted into the radon concentration by the following conversion:
0.02tracks/cm2 /day= 1Bq/m3 [8].
-
Result and Discussion:
Table 1 shows the type of houses where the LR-115 films were installed and recorded indoor radon concentrations in 40 different houses of Mandi district, Himachal Pradesh during April, 2012 to July, 2012. The indoor radon concentration obtained from the present study varied from 42.22 to 398.33 Bq/m3 with an average value of 138 Bq/m3 which are higher than the world average of 40 Bqm3 and are below the recommended action level 200-600 Bq m-3[9].The highest value was observed in the house of survey number 4 with an indoor radon concentration of
398.33 Bq/m3. The high radon concentration level in survey point 4 is due to poor ventilation, lifestyle and the accumulation of dust in the room due to the closeness of the house to the roadside which are usually considered as important sources of radon in buildings. The lowest value was found in the house of survey number 28 with an indoor radon concentration of 42.22Bq/m3. Although the indoor radon concentration is within the recommended action level 200-600Bq/m3, but all the values are higher than the world average of 40 Bqm-3. The factor explaining the high levels of radon in these houses is the poor ventilation status due to the relatively narrow openings. Also, most of the houses in the present study areas serve as both living rooms and bedrooms for the residents. This could also account for the high radon concentration levels since most of the residents valuables are kept in one room
making the room non-spacious for inflow of air. Another factor for high values of radon in the study value may be its closest to active faults where radon concentration is more.
S. No.
Name of Place
House Type
Rn (Bq/m3)
1
Barot
Mud Based
97.22
2
Barot
Dwelling
322.78
3
Barot
Wooden
and concrete
127.22
4
Barot
Concrete
based
398.33
5
Barot
Concrete
based
44.44
6
Tikkan
Concrete
based
48.89
7
Tikkan
Concrete
based
292.78
8
Jhatingni
Mud and granite
124.44
9
Jhatingni
/td>
Mud and
granite
107.78
10
Mohar dhar
Mud house
133.33
11
Mohar dhar
Mud and
granite
92.78
12
Mohar dhar
Concrete
House
124.44
13
Chipnu near
Mandi
Concrete
House
133.33
14
Chipnu near
Mandi
Concrete
House
160.00
15
Mandi
Concrete
House
138.33
16
Mandi
Concrete House
67.78
17
Mandi
Concrete
House
113.33
18
Malori
Mud House
117.22
19
Malori
Mud House
213.33
20
Lunapani
Concrete House
65.56
21
Baggi
Mud House
137.22
22
Pali near Baggi
Concrete
House
137.22
23
Pali
Mud House
140.00
24
Sundernagar
Concrete
House
126.11
25
Harabag
Concrete
128.89
Table1: Summary of the results obtained
House
26
Harabag
Concrete
House
60.56
27
Harabag
Mud House
161.67
28
Ropari
Concrete
House
42.22
29
Bhubwana
Mud House
71.67
30
Bhubwana
Mud House
143.33
31
Kangu
Concrete
House
170.00
32
Kangu
Dwelling
150.00
33
Slappar
Concrete
House
76.11
34
Slappar
Concrete
House
156.67
35
Sundernagar
Concrete
House
375.56
36
Sundernagar
Concrete
House
253.33
37
Sundernagar
Mud House
109.44
38
Sundernagar
Concrete
House
42.78
39
Sundernagar
Concrete
House
49.44
40
Lunapani
Concrete House
62.22
Average
137.94
work. We are also thankful to the people of the study area of their nice cooperation, without them it was impossible to carry out this study.
References:
-
Conclusions:
Indoor radon concentration in the study area found to be varies from 42.22 Bq/m3 to 398.33Bq/m3 with the average value of 138 Bq/m3 which are higher than the world average of 40 Bq/m3 and are below the recommended action level (200-600 Bq/m3).Variations in levels of radon concentration appear due to the use of building materials used for construction of houses and the degree of their ventilation.
Acknowledgement:
We are very grateful to the laboratory staff of the Arni University for their cooperation to complete the
-
ICRP, 1993, Protection against radon-222 at home and work, ICRP Publications 65, Annals of the ICRP, 23(2)
-
UNSCEAR, 2000,United Nation Scientific committee on the effect of atomic Radiations, United Nation, New York.
-
S. Singh, A. Kumar, and B. Singh, 2002, Radon level in dwellings and its correlation with uranium and radium content in some areas of Himachal Pradesh, India, Environ. Int., 28, pp. 97-101
-
T. Iyogi,S. Ueda, S. Hisamatsu, K. Kondo, N. Sakurai and J. Inaba, 2003,Radon Concentration in Indoor occupational Environments in Aomori prefecture, Japan J. Environ. Radioact. 67,pp 91- 108.
-
M.H. Magalhaes, E.C.S. Amaral, T. Sachett and
E.R.R. Rochedo, 2003, Radon-222 in Brazil: an outline of indoor and outdoor measurement, J. Environ. Radioact. 67,pp 131-143.
-
L.S.Bech and J.E.Gingrich, 1976,Track etch orientation survey in the Cliff Lake area, Northern Saskatchewan, Canadian Inst. Min and Met., Bull.,69,pp 104-109.
-
J.E.Gingrich and J.C. Fisher, 1976, Uranium exploration using the Track- Etch method, In : Exploration for uranium ore Deposits ,IAEA, Vienna,pp 213-227.
-
K.P. Eappen and Y.S. Mayya, 2004, Calibration factors for LR-115(Type-II) based radon thoron discriminating dosimeter, Science Direct, Radiation measurement 38, pp 5-17.
-
R. Mehra, K. Badhan, R.G. Sonkawade, S. Kansal, and S. Singh, 2010, Analysis of terrestrial natural radio nuclides in soil samples and assessment of average effective dose, Indian Journal of Pure and Applied Physics, vol 48,pp 805-808.