- Open Access
- Total Downloads : 209
- Authors : Meghana B M , Archana Sukumaran
- Paper ID : IJERTV6IS060336
- Volume & Issue : Volume 06, Issue 06 (June 2017)
- DOI : http://dx.doi.org/10.17577/IJERTV6IS060336
- Published (First Online): 19-06-2017
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Linear Analysis of Multistorey Irregular RCC Buildings with Different Sections of X-Bracing
Meghana B. M 1,
1PG Scholar,
Civil Engineering Department, Sree Buddha College of Engineering,
Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam Technological University,
Ayathil, Elavumthitta P.O, Pathanamthitta-689625
Archana Sukumaran2
2Assistant Professor, Civil Engineering Department,
Sree Buddha College of Engineering, Alappuzha/Pathanamthitta cluster of APJ Abdul Kalam Technological University,
Ayathil, Elavumthitta P.O, Pathanamthitta-689625
Abstract: The most suitable method for the improvement of reinforcement concrete structures against lateral loading is to provide steel bracing system. Braced frames are a very common form of construction, being economic to construct and simple to analyse. In the present study, G+14 storeyed RC irregular buildings is analyzed with X bracing for different IS steel sections such as rolled beam and channel sections with different depths. The building is situated in seismic zone III. Response spectrum analysis is carried out using ETABS 2015 software to investigate seismic performance of a multi storey steel frame building and to find the most effective IS section in resisting lateral loads.
Keywords: Irregular buildings, IS steel sections of X bracing, Base shear, Maximum storey displacement, Response spectrum analysis
-
INTRODUCTION
The primary purpose of all kinds of structural systems used in the building type of structures is to transfer gravity loads effectively. Besides these vertical loads, buildings are also subjected to lateral loads caused by wind, blasting or earthquake. Lateral loads can develop high stresses, produce sway movement or cause vibration. Use of steel bracing systems is one of such method which is highly efficient and economical. A bracing system improves the seismic performance of the frame by increasing its stiffness and capacity. Steel braced frames are efficient structural systems for buildings subjected to seismic or wind lateral loadings. In braced construction, beams and columns are designed under vertical load only, assuming the bracing system carries all lateral loads. The potential advantages of using steel bracing are their high strength, stiffness, economical, occupies less space and adds much less weight to the existing structure.
Steel bracings can be arranged like diagonal, cross bracing X, V, inverted V or Chevron. Rolled steel sections are often used for strut bracings in buildings and single angles for ties. The applications of braced frame includes structures like bridges, aircrafts, buildings, transmission towers. In this study, irregular high rise reinforced concrete buildings are analysed with different rolled steel sections of X bracing system.
-
OBJECTIVES
-
To investigate seismic performance of multi-storey RC irregular buildings with X bracing system located in seismic zone III.
-
To study the effect in base shear and storey drift with the variation of depth of rolled steel I sections of X bracing for all irregular buildings.
-
To study the effect in base shear and storey drift with the variation of depth of rolled steel channel sections of X bracing for all irregular buildings.
-
To find out which section is more effective in resisting lateral loads by comparing both IS sections.
-
-
SCOPE
The study is limited to:
-
Irregular plans of C, plus, I and L shape buildings with uniform eccentricity.
-
High rise RC buildings.
-
X bracing system with different rolled steel I and channel sections.
-
Linear Response- Spectrum analysis.
-
-
LITERATURE REVIEW
This chapter gives a brief review of previous studies conducted on behaviour of RC buildings provided with steel bracings.
Nitin N. Shinde, R. M. Phuke (2015)[1] published a paper on Analytical Study of Braced Unsymmetrical RCC Building. In this report two separate Unsymmetrical RCC framed buildings one braced and another unbraced subjected to lateral loads are analyzed. Different bracing sections along with different bracing systems are employed to study the seismic response of the building. The comparison is done between the braced and unbraced building on the basis of floor displacements, storey drifts, base shear, axial force and bending moments. It was observed that seismic performance of the braced building is improved as compared to unbraced building.
Dr. Ramesh B.R et.al (2015)[2] submitted a paper on Study on Effective Bracing Systems for High Rise Steel Structures. This paper is about the efficiency of using different types of bracings and with different steel profiles for bracing members for multi-storey steel frames. Wind load and Earthquake loads are taken by bracings. The bracings are provided only on the peripheral columns. Maximum of 4 bracings are used in a storey for economic purposes. In this study, an attempt has been made to study the effects of various types of bracing systems, its position in the building and cost of the bracing system with respect to minimum drift index and inter storey drift.
Anitha, Divya (2015)[3] published a paper on Seismic Effect of Different Types of Steel Bracings. In this study, a comparison of knee braced steel frame with other types of bracings had been done. Performance of each frame had been studied using non-linear static analysis and nonlinear time history analysis. In nonlinear static analysis performed, steel frame with double knee bracings shoed very good behaviour during a seismic activity. The ultimate load for double knee bracings is very much higher compared to without bracings. Double knee bracings showed more lateral stiffness compared to other type of bracings.
Krishnaraj R. Chavan et al. (2014)[4] studied on The Seismic Response of RC Building with Different Arrangement of Steel Bracing Systems. In this study, the seismic analysis of reinforced concrete buildings with different types of bracing (Diagonal, V type, inverted V type, X type) is studied. The bracing is provided for peripheral columns. A G+6 storey building is situated at seismic zone III are analyzed by equivalent static analysis as per IS 1893:2002 using STAAD Pro V8i software. It is found that the X type of steel bracing significantly contributes to the structural stiffness and reduces the maximum interstorey drift of R.C.C building than other bracing system.
Till now, all of the studies are carried out on different types of bracings in regular RC and steel buildings. So aim of this study is to investigate on the effect of different rolled steel sections of X bracings in an irregular RC building frame.
-
METHODOLOGY The response spectrum method is employed.
-
Modelling of Building
Here the study is carried out for the behaviour of G+14 storied RCC buildings with irregular plans of I, L, C and Plus shapes with X bracing system. Properties are defined for the frame structure. Three varying depths of both I and channel sections are used as bracing sections for each model. The general software ETABS has been used for the modelling. ETABS is an engineering software product that caters to multi-story building analysis and design.
-
Building Plan and Dimensions
For the present study, G+14 storied irregular RC buildings located in seismic zone III is used. Floor height is provided as 3.4m. Fixed supports are provided for all the supports. The details and dimensions of the buildings are given in Table I.
TABLE I
p>DIMENSIONAL DETAILS OF THE BUILDING
Type of structure
All general RC frame
Thickness of slab
160mm
Dimension of beam
300mm × 400mm
Dimension of column
300mm × 450mm
Grade of concrete
M25
Grade of steel
Fe415
Type of bracing used
X bracing
Steel sections of bracing
Rolled Steel Beams
ISHB 200, ISHB 250, ISHB 300
Rolled Steel Channels
ISMC 200, ISMC 250, ISMC 300
Fig.1 Plan of I shape building
Fig.2 Plan of C shape building
Fig.3 Plan of L shape building
8. 1.5(DL+EQX)
9. 1.5(DL+EQY)
10. 1.5(DL- EQX)
11. 1.5(DL- EQY) 12. 0.9DL+1.5EQX 13. 0.9DL+1.5EQY 14. 0.9DL – 1.5EQX 15. 0.9DL – 1.5EQY
-
Analysis Results
The three dimensional reinforced concrete structures were analyzed by Response Spectrum to evaluate dynamic results in form of storey shear, storey drifts in X and Y directions. It is a linear dynamic statistical analysis method to indicate the likely maximum seismic response of an elastic structure. A plot of the peak acceleration for the mixed vertical oscillators.
-
Maximum storey drift in X direction:
TABLE III
Sections of X bracing
Shape of Plan of Buildings
I
L
C
PLUS
ISHB 200
0.001701
0.002164
0.001957
0.001697
ISHB 250
0.00154
0.001949
0.001775
0.001566
ISHB 300
0.001407
0.001762
0.001608
0.001283
ISMC 200
0.001955
0.002491
0.002226
0.001361
ISMC 250
0.001752
0.002246
0.002023
0.001249
ISMC 300
0.001672
0.002156
0.001918
0.001174
MAXIMUM STOREY DRIFT IN X DIRECTION FOR DIFFERENT I AND CHANNEL SECTIONS OF X BRACING
Fig.4 Plan of PLUS shape building
-
-
-
Load Formulation
For given structure, loading is applied which includes dead load, live load, earthquake load and floor finish and are according to IS 875 part I, part II and IS 1893:2002
-
Live Load Floor load:
Live Load Intensity specified (Commercial building) = 4kN/m2 Live Load at roof level =1.5 kN/m2
TABLE II EARTHQUAKE LOAD DATA
Earthquake zone
III
Damping ratio
5%
Importance factor, I
1
Type of soil
Medium soil (Type II)
Response reduction factor, R
5
Zone Factor ,Z
0.16
-
Load Combinations
The following Load combinations have been considered for the analysis
-
DL
-
DL+LL
-
-
3. 1.5(DL+LL)
-
1.2(DL+LL+ EQX)
-
1.2(DL+LL+ EQY)
-
1.2(DL+LL – EQX)
-
1.2(DL+LL – EQY)
-
Maximum storey drift in Y direction:
TABLE IV
MAXIMUM STOREY DRIFT IN Y DIRECTION FOR DIFFERENT I AND CHANNEL SECTIONS OF X BRACING
Sections
of X bracing
Shape of Plan of Buildings
I
L
C
PLUS
ISHB200
0.001597
0.002003
0.001534
0.001637
ISHB 250
0.001421
0.001855
0.001307
0.001471
ISHB 300
0.001384
0.001638
0.001298
0.001209
ISMC 200
0.001581
0.002429
0.001368
0.001353
ISMC250
0.001463
0.002155
0.001256
0.001211
ISMC300
0.001361
0.002025
0.001203
0.001158
It is found that as the size of the both sections increases, the value of maximum storey drift decreases for all irregular buildings. In beam sections of X bracing, ISHB 300 has minimum value of storey drift and in channel sections, ISMC 300 has the minimum value in both X and Y directions.
-
Base Shear:
TABLE V
-
Maximum Storey Drift in Y Direction
Sections of X bracing
Shape of Plan of Buildings
I
L
C
PLUS
ISHB 200
19048
12214
19991
14273
ISHB 250
20597
13374
21530
15535
ISHB 300
22219
14580
23067
16971
ISMC200
16877
10857
18009
8678.43
ISMC250
18497
11867
19539
9454.42
ISMC300
19354
12257
20242
14520
BASE SHEAR FOR DIFFERENT I AND CHANNEL SECTIONS OF X BRACING
It is found that as the size of the both sections increases, the value of base shear also increases for all irregular buildings. In beam sections of X bracing, ISHB 200 has minimum value of base shear and in channel sections, ISMC 200 has the minimum
Fig.6 Comparison of Storey Drift in X Direction among I and Channel Sections of X Bracing in Irregular Buildings
From graph, it is found that in Y direction, ISHB 300 has minimum value of storey drift in L shape building. But in I, C, plus shape buildings, there is only a little variation in storey drift value between ISHB 300 and ISMC 300 and the minimum value is for ISMC 300.
value.
-
-
RESULTS AND DISCUSSIONS
-
Base Shear
After analysing the models various results are obtained. The results of base shear and storey drift in X and Y directions are represented graphically. The performance of ISHB and ISMC sections are compared to find which section of X bracing is more effective in resisting lateral loads.
A. Maximum Storey Drift in X Direction
Fig.5 Comparison of Storey Drift in X Direction among I and Channel Sections of X Bracing in Irregular Buildings
From the graph, it is found that in X direction, ISHB 300 has minimum value of storey drift for I, L, C shape buildings and for plus shape building, ISMC 300 has the minimum value.
Fig.7 Comparison of Base Shear among I and Channel Sections of X Bracing in Irregular Buildings
From the graph, it is seen that, ISMC 200 has minimum base shear for I, L, C, plus shape buildings and maximum for ISHB 200 in all irregular shape of buildings. Thus ISMC 200 is better in terms of base shear.
-
-
CONCLUSIONS
-
As size of section increases, maximum storey drift decreases for both ISHB and ISMC sections for all irregular plan of buildings.
-
The value of base shear increases for both ISMC and ISHB sections with increase in size of section for all irregular buildings.
-
In beam sections of X bracing, ISHB 300 and in channel sections, ISMC 300 has the minimum value of storey drift in both X and Y directions.
-
In beam sections of X bracing, ISHB 200 and in channel sections, ISMC 200 has the minimum value of base shear.
-
In X direction, ISHB 300 has minimum value of storey drift for I, L, C shape buildings and ISMC 300 has the
minimum value for plus shape building (percentage reduction for I shape is
-
In Y direction, ISHB 300 has minimum value of storey drift in L shape building. But in I, C, plus shape buildings, ISMC 300 has the minimum value.
-
In base shear point of view, ISMC 200 has minimum base shear for I, L, C, plus shape buildings.
-
ACKNOWLEDGEMENT
I am thankful to my guide, Asst. Professor, Archana Sukumaran in Civil Engineering Department for her constant encouragement and able guidance. Also I thank my parents, friends etc. for their continuous support in making this work complete.
REFERENCES
-
Nitin N. Shinde, R. M. Phuke, Analytical Study of Braced Unsymmetrical RCC Building, International Journal of Science and Research, Volume 4 Issue 5, pp 485-489, May 2015
-
Adithya. M, Swathi rani K.S, Shruthi H K, Dr. Ramesh B.R, Study On Effective Bracing Systems for High Rise Steel Structures, International Journal of Civil Engineering, volume 2 Issue 2, pp 19-23, February 2015
-
Anitha, Divya, Seismic Effect of Different Types of Steel Bracings, IJSR, pp 49-53, 2015
-
Krishnaraj R. Chavan et al., The Seismic Response of RC Building with Different Arrangement of Steel Bracing Systems. International Journal of Science and Research, Volume 3 Issue 2, pp 39-43, 2014
-
Vani Prasad et al. Effectiveness of Inclusion of Steel Bracing in Existing RC Framed Structure. , IJSR, 2014
-
Linu Shaji, Sreedevi Lekshmi, Seismic and Structural Behavior of Building with Different Combination of Bracing, IJSR,
Volume 5 Issue 7, pp 1107-1112, July 2016
-
Zasiah Tafheem, Shovona Khusru, Structural behaviour of steel building with concentric and eccentric bracing: A comparative study International Journal Of Civil And Structural Engineering,
Volume 4, No 1, 2013
-
Sachin Dhiman, Mohammed Nauman, Nazrul Islam, Behaviour of Multistory Steel Structure with Different Types of Bracing Systems, International Refereed Journal of Engineering and Science, Volume 4, Issue 1, pp 70-82, January 2013
-
Prof. Sarita Singla and et al.,Behaviour of Framed Building with Different Lateral Bracing Systems, Journal of Structural Engineering, 2012
-
S. Sabouri-Ghomi1 and P. Ebadi, Concept improvement of behavior of X-Bracing systems by using Easy-Going Steel, pp 1-7, 2008
-
IS: 800-2007 Indian Standard General Construction in Steel- Code of Practice.
-
IS: 1893 (Part-1): 2002, Indian Standard Criteria for Earthqauke Resistant Design of Structures Bureau of Indian Standards, New Delhi.
-
IS: 875 (Part 2) 1987, Indian Standard Code of Practice For Design Loads (Other Than Earthquake) For Buildings And Structures, Part 3 Imposed Loads.