Non Linear I-V Curve of PV Module: Impacts on MPPT and Parameters Estimation

DOI : 10.17577/IJERTV1IS8553

Download Full-Text PDF Cite this Publication

Text Only Version

Non Linear I-V Curve of PV Module: Impacts on MPPT and Parameters Estimation

B.K. Nayak1

School of electrical Engg., Kalinga Institute of Industrial Technology, Bhubaneswar, India

A.Mohapatra2

School of electrical Engg., Kalinga Institute of Industrial Technology, Bhubaneswar, India

B.Misra3

School of electrical Engg., Kalinga Institute of Industrial Technology, Bhubaneswar, India

Abstract

This paper explains the various issues regarding the parameters extraction of PV module and performance improvement of MPPT tracker. The comparative analysis of parameters extraction using iterative method and trust-region-dogleg method is presented. The effect of dynamic resistance on MPPT and dc-dc converter due to non linear characteristic of PV module is presented. The criteria for choosing various type dc-dc converters are explained. The necessity of capacitor across the solar cell and its design is explained. This paper gives the basic fundamentals of PV module for researchers to extend the modelling and feedback controller design in stand-alone mode or synchronization to grid for power transfer.

  1. Introduction

    Clean and renewable energy sources such as photovoltaic (PV) power generation are expected to become essential for mitigating global warming. A photovoltaic cell converts sunlight to electricity. The number of cells is grouped in series and parallel to form large photovoltaic arrays in order to meet the voltage and current of the load. It is possible to use PV power in stand-alone mode or distributed generation mode (micro grid).Since PV arrays exhibit nonlinear I-V characteristic and also the characteristic is modified by changing of temperature and solar radiation, their power output mainly depends on the nature of the

    connected load. Hence, direct load connections to PV systems result in poor overall efficiency. As solar panels are still expensive, minimizing the cost of their life cycle has recently become an important consideration. To achieve some of these goals, direct connected PV systems are being replaced by PV systems having an intermediate maximum power point (MPP) tracker. The power generated from a given PV module mainly depends on solar irradiance and temperature. As these quantities vary with time[1], it is necessary to develop a control logic that continuously monitors the terminal voltage and current and updates the control signal accordingly. To achieve these goals, various conventional single-stage (CSS) MPP tracking (MPPT) algorithms have been proposed and used to extract maximum power from PV arrays under different operating conditions. Connecting one PV array is not recommended due to space limitations for installation in addition to the load voltage and current demands. Normally large number of PV array known as modular connection are connected in series and parallel fashion, in order to satisfy the required voltage and current demands. Modular connection has several advantages both from a physical layout as well as a load demand point of view. These can be broadly classified into two schemes from the MPPT point of view wherein

    1. Each modular PV system may be provided with its own MPPT controller, and

    2. All the modular PV systems may be controlled by a single centralized MPPT controller.

    A battery is required to act as extra source and load in stand alone mode or grid connection PV module in order to mitigate the flow of power. Unlike fixed dc input voltage of dc-dc converter for regulated voltage load, the input voltage or input current of PV module is

    regulated through MPPT, using dc-dc converter in such a way that the output voltage and current of the MPPT is always at maximum power point of PV module. The dc-dc converter may be buck, boost or buck-boost type depending upon PV voltage and battery voltage, used as an extra load or extra source. If the load demand is more than the maximum power production of PV panel, operated in stand-alone mode, the extra load demand is supplied by battery. In this condition the battery and PV module act as sources of the system. The extra power of PV module is used for charging of battery in reverse condition. In micro grid connection, an inverter is required for connecting to grid at the common point of coupling, where the power of PV module and battery is used to fulfil of the power demand of sensitive load. During disturbances, the PV

    Figure 1. Equivalent circuit of a PV module using one diode

    The Equivalent circuit with single diode of the photovoltaic module is shown in Fig-1.The basic equation that mathematical describes the I-V characteristic of PV array is [2]:

    generation and corresponding loads can separate from

    I = I

    I exp V+RsI 1 V+RsI

    (1)

    the distribution system to isolate the microgrids load through the static switch and thereby the PV module

    pv 0

    Ns Vt a Rp

    charges the battery without harming the transmission grids integrity. Thus the MPPT and the dc-dc converter can provide the flow and control of power in stand-alone mode, whereas Inverter and MPPT with dc- dc converter together used to control the flow of power effectively required for plug-and- play functionally in microgrid connection. The control function of inverter includes to synchronization of voltage, frequency and phase before connecting the PV module to grid at common point of coupling.

    This paper presents the various technical issues and solutions such as selection of dc-dc converter circuit, design of passive parameters in dc-dc converter and MPPT tracking problem. The aim of the paper is to provide the researcher the various problems associated with PV model used mainly in stand-alone mode, so that the researcher can enhance the research capability to improve the system dynamics. Nevertheless, the above technical issues can also be applicable in microgrid connection.

    Where Ipv(Ipv,cellNp) and I0(I0,cellNp) are the photovoltaic and saturation currents of the module consist of Ns cells connected in series and Np cells connected in parallel and Vt=kT/q is the thermal voltage of the PV cell. q is the charge of electron (1.602.10-19C) ,k is the Boltzmann constant (1.3806503.10-23J/K),T in Kelvin(K) is the temperature of junction and a is the diode ideality constant, whose range lies between 1 to

    1.5. Rs [rs (Ns/Np)] and Rp [rp (Ns/Np)] are the equivalent series resistance and equivalent parallel resistance of the module respectively, where rs and rp denote the series and parallel resistance of PV cell .The I-V characteristic of PV module depends on the internal passive parameters of the device(RS, Rp) as shown in eq.-1.Not only the I-V characteristic depends on internal passive parameters but also depend on the temperature and solar insolation (irradiance) level. The change of temperature and irradiance has an effect of the PV module according to the following equations [7]:

    G

    Ipv=[Ipv,n+Ki T-Tn ] G

    n

    (2)

    Voc=[Voc,n+Kv T-Tn ] (3)

  2. Modelling of PV and parameter extraction

    RS I

    Here the subscript n represents the nominal condition (usually Tn= 250C and Gn=1000W/m2).Ki the short- circuit current/temperature coefficient and Kv denote the open-circuit voltage/temperature coefficients of solar cell.

    As shown in equation-2 the current level of solar cell depends on temperature and irradiance level of PV module. Voltage depends on temperature directly and in turn depends on irradiance level indirectly because of current dependent. Data sheets of PV module only inform three remarkable point, that is te short circuit

    IPV

    D RP

    V

    Id

    www.ijert.org 2

    point (0,Isc,n),Maximum power point(Vmp,n,Imp,n) and open circuit point(Voc,n,0) under nominal operating condition(usually 250C and 1000W/m2).To draw the I- V characteristic as in Fig-2,the nominal saturation current is written as [3]:

    the Ki and Kv are calculated. The values are found to be:

    Ki

    -0.1229V/K

    By Expt.

    Kv

    0.0031 A/K

    do

    0,n

    I = Isc ,n

    exp V oc ,n 1 a N s V t ,n

    9

    mp

    Isc=8.21 V =26.3

    (4)

    Table 1

    Parameters of KC200GTsolar array at nominal 250 C,1.5 AM,1000w/m2

    8 Current source region

    7

    Current in Amp.

    6

    5

    4

    3

    2

    1

    0

    MPP

    Power region

    Imp=7.61

    Voltage source region

    Voc=32.9

    Isc,n

    8.21

    Voc,n

    32.9

    Vmp,n

    26.3

    Imp,n

    7.61

    Ns

    54

    The other parameters are estimated by using different techniques given in different literatures. The equations are used as follows [3][6]:

    0 5 10 15 20 25 30 35

    Voltage in Volt.

    = +

    (5)

    Figure 2. Characteristic I-V curve of PV module

    ,

    ,

    and the three remarkable points

    = , , ,

    (6)

    ,

    , ,

    ,

    250

    200

    Pmax=200.143W

    Rewriting equation (1) at the short circuit, open circuit and MPP points yield:

    Power in Watt

    Isc ,n = Ipv ,n I0,n exp RsIsc ,n 1 Rs Isc ,n

    (7)

    150

    100

    MPP

    Ns Vt ,n a Rp

    Ipv ,n = I0,n exp Voc ,n 1 + Voc ,n

    (8)

    Ns Vt ,n a Rp

    50

    Imp ,n

    = Ipv ,n

    I0,n

    exp Vmp ,n +Rs Imp ,n 1

    Ns Vt ,n a

    0

    0 1 2 3 4 5 6 7 8 9

    Current in Amp.

    Vmp ,n +Rs Imp ,n

    Rp

    (9)

    Figure 3. Characteristic P-I curve of PV module

    As shown in Figure-2, the I-V characteristic is divided into three operating regions, such as voltage

    Another three equations can be written by taking the derivative of three remarkable points[6]:

    (dP V = Vmp ,n = 0, dI I = Isc ,n = 1

    source region, power source region and current source dV

    dV RP

    region. To improve the MPP tracking of maximum

    and dI | V = Voc ,n = 1 ):

    power point, it is required to operate the MPP in power region and voltage region before tracking the maximum power point. The explanation of the above is explained in latter paragraph. The I-P curve is shown in Figure.3, which indicates that at one point the power of PV

    dV

    I0 s Imp ,n 1

    , = V

    N s a V t ,n

    mp ,n

    RS

    V mp ,n +R

    exp N s a V t ,n +R p

    V mp ,n +R

    (10)

    module is maximum. In order to examine the

    R I s I

    s 0 mp ,n R s

    p

    1+ exp +

    performance analysis and improve the dynamic performance the various parameters of PV cell must be known. By experiment in two different conditions, one at nominal condition and other at 300C and 500w/m2,

    N s a V t ,n

    N s a V t ,n R

    I0 exp R s Isc ,n + 1

    8.4

    1 = N s a V t ,n N s V t ,n a R p

    (11)

    Rp 1+ R s I0 exp R s Isc ,n +R s

    8.35

    N s a V t ,n

    N s V t ,n a R p

    8.3

    I0 exp V oc ,n + 1

    8.25

    Current in Amp.

    8.2

    =

    1 N s a V t ,n

    R s I0

    N s V t ,n a R p

    V oc ,n R s

    (12)

    8.15

    1+N s a V t ,n exp N s V t ,n a +R p

    8.1

    8.05

    Rp=415 ohm Rp=500 ohm Rp=800 ohm

    The variations of I-V curve for different Rp and Rs are shown in Figures-(4, 5) and maximum power point in tabular forms in Table-2 and Table-3.

    Table 2

    Rs in

    Ohm

    Rp in

    Ohm

    Vmp,nin

    Volt

    Imp,n in

    Amp.

    Pmax in

    watt

    0.221

    415

    26.3480

    7.5956

    200.1301

    500

    26.3500

    7.6051

    200.3935

    800

    26.3550

    7.6220

    200.8786

    Table 3

    Rp in

    Ohm

    Rs in

    Ohm

    Vmp,nin

    Volt

    Imp,n in

    Amp.

    Pmax in

    watt

    415

    .221

    26.3480

    7.5956

    200.1301

    .24

    26.2230

    7.5904

    199.0436

    .28

    32.8990

    7.7218

    254.0396

    The two parameters Rs and Rp are estimated using equation-1 and comparing the maximum power at different Rs and Rp with actual maximum power by incrementing Rs. The drawback of the method is that value of a is considered 1.3 before the iterative process starts. The other parameters (Ipv,n,I0,n) are determined using the equations(4,5). The value of estimation is dependent upon the assumption of initial condition and also the chosen tolerance band for power. Furthermore it also depends on the increment of Rs. As shown in Figure-4, the change of value of Rp is modified the slope of current source region and also the power region, whereas the change of value of Rs is modified the slope of voltage source region and the power region. The change of power region and slope of current source region is very less with wide change of Rs as shown in table. Therefore the exact value of Rs is difficult to estimate by this method if chosen tolerance band is large. In this method the increment of Rp is not allowed because of the iterative solution may not be converged as Rs may exceed the value (greater than.28) where the slope at open circuit condition is infinity, which is confirmed by Figure-5.

    8 5 10 15 20 25

    0

    Voltage in Volt.

    Figure 4. Partial representation of I-V curve of PV module at different values of Rp

    9

    8

    7

    Current in Amp.

    6

    Rs=.221 Ohm

    Rs=.240 Ohm Rs=.280 Ohm

    5

    4

    3

    2

    1

    0

    0 5 10 15 20 25 30 35

    Voltage in Volt.

    Figure 5. Characteristic of I-V curve of PV module at different values of Rs

    Another method used in literature is trust-region- dogleg, which is used to solve the non-linear equations by fsolve in matlab command. The equations (7, 8, 9, 10, 11) are used. In this method the five unknown quantities are estimated. The accuracy of estimation is dependent on the initial conditions. Convergence rate depends on the initial conditions, tolerance band and the equations used in fsolve example. As for example, the estimation values are not converged, if the equation-12 is used instead of equation-11 in fsolve command. The main region is the slope at this point is more sensitive to move towards infinity. The author has verified the above two methods using the value of a=1.3 in first method. The results are shown in Table4 and Table-5.

    Table 4

    Tolerance=0.01

    Tolerance=0.001

    Remark

    Rs=0.2173 Ohm

    Rs=0.2246 Ohm

    Estimate d

    Rp=370Ohm

    Rp=483Ohm

    do

    Ipv,n=8.2148Ohm

    Ipv,n=8.2138Amp.

    Formula

    I0,n=9.8944.10-8Ohm

    I0,n=9.8944.10-8Am.

    do

    Initial

    Table 5

    Initial values(.001,50,8,10-

    values(.001,40,8,10-7,1)

    7,1)

    Rs=0.260 Ohm

    Rs=0.201 Ohm

    Rp=462Ohm

    Rp=471Ohm

    Ipv,n=8.17Amp.

    Ipv,n=8.1637Amp.

    I0,n=9.10-8Amp.

    I0,n=9.10-8Amp.

    a=1.7655

    a=1.7436

    The exact values of unknown quantities can be found out using non linear curve fitting method. This method is based on non linear least square method using the experimental data. Hence exactness depends on the correctness of data. Detail comparative analysis of parameters estimation is explained in detail in another literature, which has submitted for publish.

  3. Analysis of converter used in solar system

    1. Selection of Proper dc-dc converter

      12

      10 G=1000W/m2

      G=800W/m2

      G=500W/m2

      Current in Amp.

      8 G=200W/m2

      dependent on insolation level, but less dependent on temperature. The I-V characteristics for different insolation and temperature and are shown in Figure-6 and Figure-7.The fast dynamics of insolation is usually caused by a cover of mixed moving clouds. If the MPPT is used to track the current at the maximum power point, the MPP tracking requires fast dynamics to follow a wide operating range, depending on irradiance level which changes rapidly on weather condition. Nevertheless, the changing insolation slightly affects the voltage variation at MPP point as shown in fig. The cell temperature is the major factor for shifting the voltage at MPP point. Temperature posses slow dynamics as compared to insolation and therefore the MPPT is used to track the voltage at maximum power point. The variation of voltage is usually bounded by 70% to 80% of the open circuit voltage under any condition of temperature and insolation. This is the deciding criteria for choosing of proper dc-dc converter depending upon the battery used at output terminals of converter.The stand-alone mode of solar module using dc-dc buck converter is shown in Figure- 8.The MPPT control procedure is shown in Figure-9.

      6 MPP Point

      4

      2

      0

      0 5 10 15 20 25 30 35

      Voltage in Volt.

      Figure 6. Simulated I-V curve of PV module influenced by different insolation levels with constant temperature of 250C

      12

      Figure 8. Circuit diagram of dc-dc buck converter in stand-alone mode

      10

      Current in Amp

      8

      6

      T=00C.

      4 T=300C.

      T=600C T=900C.

      2

      MPP Point

      0

      0 5 10 15 20 25 30 35 40

      Voltage in Volt.

      Figure 7. Simulated I-V curve of PV module influenced by different temperature levels with constant insolation of 1000W/m2

      It is necessary to track the input voltage or current of PV module in such a way that power extracted from PV module is always maximum at any condition. The PV current at which maximum power occurs is highly

      Figure 9. Block diagram for regulate of PV voltage at maximum power point through MPPT

      • If the battery voltage is below the 70% of the open circuit voltage the buck converter can be used for transfer of the power.

      • If the battery voltage is above the 70% of the open circuit voltage the boost converter can be used for transfer of the power.

      • Buck-Boost converter is used for any range of battery voltage rating.

      0

      Dynamic resistance in Ohm.

      -50

      -100

      -150

    2. Capacitor requirement and determination of its value

      A buck dc-dc converter has a discontinuous input current and a continuous output current. On the contrary, a boost converter has a continuous input current and a discontinuous output current. In order to flow the continuous PV current at maximum power point the capacitor must be connected in shunt to PV cell in buck dc-dc converter, so that the current will

      -200

      -250

      -300

      -350

      -400

      -450

      G=1000W/m2 G=800W/m2 G=600W/m2 G=200W/m2

      10 15 20 25 30 35

      Voltage in Volt.

      flow through the capacitor during the switch off period. Other capacitor at output may be connected for filter purpose. The value of capacitor depend upon the battery voltage ,the worst case of the PV current at MPP, open circuit voltage of PV, change of Vmp during switching off period and switching frequency.

      Let the battery voltage is V, which is less than the 70%of the open circuit voltage and the PV current at maximum tracking point is Imp,wg in worst case of insolation.

      D = V

      . 7Voc

      Figure 11. Dynamic resistance with change in

      PV voltage for different levels of module insolation

      The characteristic of PV modules are nonlinear and time variant due to rapid change of insolation level. Due to nonlinearity, the ratio of the voltage across the PV module to the current through it varies with either the voltage or current. The ratio of change in voltage to change in current is known as dynamic resistance. The dynamic resistance remains constant in voltage source region due to linearity of I-V curve of PV module, whereas it remains approximately constant in power

      C = Imp ,wg (1D)Ts

      (.7Voc )

      (13)

      region. The wide variation of dynamic resistance in

      current source region due to large nonlinearity in current source region makes it difficult to track the

      where D is the duty ratio and Ts is the switching frequency. The value of capacitor is calculated using eq-(13).

    3. Dynamic resistance and its impact on MPP tracking[1]

      0

      -50

      Dynamic resistance in ohm.

      -100

      -150

      maximum power point, if the MPPT operates in current source range. The dynamic resistance of PV module is negative although the static resistance of the circuit element is defined as positive. To improve the MPP tracking and the design of feedback controller to regulate the PV voltage through dc-dc converter, it is important to understand the distribution of dynamic resistance at the MPPs regarding different temperature and insolation.Dynamic resistances with respect to PV

      -200

      -250

      -300

      -350

      -400

      T=00 C. T=300 C T=600 C T=900 C

      voltage at different levels of temperature module and different insolation level are shown in Figure-10 and Figure-11 respectively. From the Figures (10, 11) it is clear that their amplitudes increase with decreasing module temperature or with decreasing insolation. The

      -450

      5 10 15 20 25 30 35

      Voltage in Volt.

      Figure 10. Dynamic resistance with change in PV voltage for different levels of module temperature

      largest amplitude occurs when the insolation and temperature both are at lowest level. Unlike the control of output of dc-dc converter with fixed dc input voltage, the controller design of PV module is difficult and need more attention for achieving stability in all region of PV curve due to large variation of current and large change of dynamic resistance with the variation of insolation and temperature level.

  4. Conclusion

    The two methods for extraction of parameters are compared. The methods explained in this paper are not free from error. The causes of error are explained in detail. The curve fitting method is the one of the choice for exact estimation of parameters, if exact data is available by experiment. The change of the characteristic of I-V curve of PV module with change of temperature and insolation level is explained in detail. The impact of change of current due to change in insolation level in PV module is more than the change of temperature. Furthermore, the change of insolation posses fast dynamic compared to change in temperature. For this reason, the output of MPPT must be voltage at which the PV module has maximum power. A capaitor must be connected in parallel to PV module before the dc-dc converter to transfer the power to load through battery or synchronization of the PV module to grid. The value of capacitor is calculated in worst case condition. The choice of different types of dc-dc converters depends on battery voltage is explained in detail.

  5. References

[1] W.Xiao , W.G.Dunford , P.R. Palmer, A. Capel: Regulation of photovoltaic voltage, IEEE Trans. Ind. Electron., 2007, 54, (3), pp. 13651374.

[2]M.G.Villalva, J.R. Gazoli, E.F.Ruppert: Comprehensive approach to modeling and simulation of photovoltaic arrays, IEEE Trans. Power Electron., 2009, 25, (5), pp. 11981208.

  1. M.G.Villalva, J.R. Gazoli, E.F.Ruppert: Modeling and circuit-based simulation of photovoltaic arrays, Revista Eletronica de Potencia (SOBRAEP), Brazilian J. Power Electron., 2009, 14, pp. 3545.

  2. M.G.Villalva, T.G De Siqueira, E.Ruppert : Voltage regulation of photovoltaic arrays: small-signal analysis and control design,IET Power electron.,2010,Vol.3,Iss. 6, pp. 869880.

  3. Ghias Farivar, Behzad Asaei: Photovoltaic Module Single diode Model Parameters Extraction Based on Manufacturer Datasheet ParametersIEEE Int.Conf.Power and energy(PECon 2010),Nov 29-Dec 1,2010,Kuala Lumper,Malaysia, pp. 929934.

[6]D. Sera, R. Teodorescu, and P. Rodriguez, PV panel model based on datasheet values, in Proc. IEEE Int. Symp. Ind. Electron. (ISIE), 2007,pp. 23922396.

[7]Ayedh H.ALQahtani, A Simplified and Accurate Photovoltaic Module Parameters Extraction Approach using Matlab,IEEE 2012, pp. 17481753.

[8]B.Subidhi,R.Pradhan,A comparative study on solar array parameter extraction methods Inderscience,Int.J.Renewable Energy Technology,vol 3,No 3,2012, pp. 295315.

  1. Ye Zhihao, Wu Xiaobo: Compensation loop design of a photovoltaic system based on constant voltage MPPT. Power and Energy Engineering Conf.,2009, APPEEC 2009,

    Asia-Pacific, 2731 March 2009,pp. 14

  2. D. Chan and J. Phang, Analytical methods for the extraction of solarcell single- and double-diode model parameters from i-v characteristics,Electron Devices, IEEE Transactions on, vol. 34, no. 2, 1987, pp. 286293.

International Journal of Engineering Research & Technology (IJERT)

ISSN: 2278-0181

Vol. 1 Issue 8, October – 2012

Leave a Reply