- Open Access
- Total Downloads : 225
- Authors : Dr. Abhipsa R Makwana
- Paper ID : IJERTV6IS040773
- Volume & Issue : Volume 06, Issue 04 (April 2017)
- DOI : http://dx.doi.org/10.17577/IJERTV6IS040773
- Published (First Online): 28-04-2017
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Nutrient Removal through Electrocoagulation
Dr. Abhipsa R Makwana
Assistant Professor
Civil Engineering Department, Faculty of Technology and Engineering The Maharaja Sayajirao University of Baroda, Gujarat, India
Abstract: -Several biological processes are having one major limitation for inefficient nutrient removal despite of type of nutrient like phosphate or nitrogen. Further large uses of fertilizer add on the concentration of nutrient in underground water as well in direct runoff which ultimately contributes to surface water. Recently anaerobic biological treatments are gaining wide interest by young researchers and hence understanding limitations of such treatment is necessary and research towards minimization of these limitations is also needed. Upflow anaerobic sludge blanket is one of the anaerobic treatments. In India there are more than 25 STP based on upflow anaerobic sludge blanket reactor. UASB reactor hardly alters nutrient level of effluent being treated. On the other hand electrocoagulation treatment promises good removal of pollutants. Hence simulated phosphate wastewater treatment was carried to understand nutrient removal possibility from anaerobically treated wastewater. Current density, electrolysis time, waste strength, NaCl dose, initial pH, interelectrode distance are various process variables which affect EC efficiency. This study reports effect of electrocoagulation process variables on phosphate wastewater. In this study effect of current density, electrolysis time and waste strength were studied using response surface methodology (RSM) as a statistical tool for design of experiments and statistical data analysis. RSM was done using Design Expert software version 8.0. It is reported through RSM studied that the variation in applied current, exposure time and phosphate concentration has direct effect on EC process efficiency.
Keywords: Electrocoagulation, Current Density, RSM, Electrode.
I. INTRODUCTION
Fast population growth and fast urbanization leads to more use of fertilizer in the farming activity and simultaneous demands efficient sewage treatment which can promise proper nutrient removal. Anaerobic technology presents a high potential in most developing countries for domestic wastewater treatment, and thus is a suitable and economical solution [5]. Within the spectrum of anaerobic sewage treatment technologies, the upflow anaerobic sludge blanket (UASB) reactor offers great promise, especially in developing countries that usually have hot climates [5]. India is one of the leading countries in terms of the amount of sewage volume treated by the UASB process (Sato et al, 2006). At present about 23 number of sewage treatment plants with total installed capacity of 985 MLD (MoEF, 2005
– 2006) based on the UASB are in operation and about 20 number are in pipeline which are likely to be commissioned within next 3-4 years.
Electrocoagulation is a process consisting of creating metallic hydroxide flocks within the wastewater by electro-dissolution of soluble anodes, usually made of iron or aluminium [1]. The difference between electrocoagulation and chemical coagulation is mainly in the way aluminium ions are delivered [1]. In electrocoagulation, coagulation and precipitation are not conducted by delivering chemicals called coagulants to the system but via electrodes in the reactor [2]. Suitable electrode choice is very important in electrocoagulation. Most common electrode materials are iron and aluminium. Both of these are cheap, easily found and effective materials [1].
There are several variables or factors which influence performance of electrocoagulation treatment process. These variables include current density, reaction time, electrolyte concentration (NaCl dose), initial pH, initial effluent concentration, type of electrode connection (monopolar, bipolar etc), sludge formation, interelectrode distance and temperature. In the present study effect of CD, time and waste strength has been studied to understand their effect on phosphate removal using response surface methodology as a statistical tool for process optimization.
II MATERIAL AND METHOD
-
Experimental
In the experimental study, simulated phosphate solution was prepared at laboratory using sodium phosphate salt (Na3PO4.H2O). The experimental setup is shown in Fig. 1 for process optimization. The electrocoagulation cell was made up from glass with 250mm x 100mm x 100mm.
Fig. 1 Experimental set up for process optimization study (adopted from [6])
Two aluminium electrodes (anode-cathode) assembly was used for process optimization. The anode and cathode are of 190 mm x 80 mm x 5 mm with effective sacrificial electrode area of 60 cm2. The simulated phosphate solution used per batch run was 600 mL, interelectrode spacing was 15 mm. DC power supply was given to the electrodes to perform EC process. All treatment runs were performed at room temperature of 25-27°C. 100 rpm magnetic stirring was given to ensure proper mass transfer. After completion of each run treated wastewater was collected through the treated effluent outlet located at 20mm above the bottom of inner surface of EC cell. After each run electrodes were washed using 1N HCl to avoid passivation.
-
Experimental Design and Data Analysis
The Box-Behnken design (BBD) is an economical, efficient and rotatable quadratic design where factor
Further, electrocoagulation process involves destabilization of particulate impurities and their aggregation. Destabilization of pollutant is faster stage in EC process but aggregation stage needs more time for accomplishment. The first stage is usually short, whereas the second stage is relatively long [7]. Efficient pollutant removal is possible when both stages are done, this can be achieved by giving enough time to the treatment.
Varying concentration of phosphate is necessary to take in to account due to varying concentration of nutrient in surface runoff as well as in anaerobically treated wastewater. Following tables shows design matrix along with observed and predicted response values.
TABLE II DESIGN MATRIX ALONG WITH OBSERVED AND PREDICTED
RESPONSE VALUES
combinations are at the midpoints of the edges and at the centre [3,4,6]. The central points are used to estimate the experimental error and to perform the model adequacy check.
mA/cm2
mg/L
Actual
Predicted
1
-1
-1
0
57.77
49.53
2
1
-1
0
39.6
44.59
3
-1
1
0
57.43
52.44
4
1
1
0
81.19
89.43
5
-1
0
-1
48.51
50.88
6
1
0
-1
77.23
66.90
7
-1
0
1
59.48
70.34
8
1
0
1
89.26
86.36
9
0
-1
-1
40.59
46.2
10
0
1
-1
52.28
54.63
11
0
-1
1
52.57
50.22
12
0
1
1
95.15
89.54
13
0
0
0
90.23
91.22
14
0
0
0
90.72.
91.22
15
0
0
0
90.94
91.22
16
0
0
0
92.94
91.22
Std Run
Current density
Time min
Influent phosphate
Phosphate removal (%)
Where y represents the predicted response; xi and xj are the independent variables, b0, bi, bii and bij are regression coefficients for intercept, linear, quadratic and interaction coefficients respectively, is the error and k is the number of variables studied.
Table. I shows the independent variables used for RSM along with their coded values. The BBD factorial design with five replicates at central point is presented in Table 3. To evaluate the contribution of the three variables, experimental data were analysed and fitted to the following second-order polynomial model using Design Expert 8.0 software.
TABLE I EXPERIMENTAL RANGE AND LEVELS OF THE INDEPENDENT VARIABLES
Variable
Factors
-1
0
1
CD (mA/cm2)
x1
1
5
9
Time (min)
x2
1
7
13
Coded Form
Waste strength as Phosphate (mg/L)
x3 1 6 11
17 0 0 0 91.25 91.22
-
Model Development and Validation
-
Obtained results of effluent phosphate removal (%)are presented in Table II. Observed removal percentages were used to develop the model using second order polynomial as shown in equation (1). Following equation (2) represents
III. RESULTS AND DISCUSSION
Applied voltage is important process variable which has
model for % phosphate removal in terms of coded factors.
direct effect on the efficiency of EC process. Increase in applied voltage provides more sacrificial metal electrode ions
Phosphate removal (%)
= +91.22 + 8.01×1 +11.94×2 + 9.73×3 + 10.48×1 x2 -11.87x 2
1
20.35x 2 10.72x 2 (2)
to get dissolved in the solution and thus enhances the EC 2 3
process. Therefore, more metal ion dissolution increases
hydroxide floc formation in the reactor, which improves the efficiency of the process. More application of current will induce more metal dissolution which removes pollutant, but for any specific waste concentration there is a specific metal ion to pollutant load ratio which has to balance to suggest cost effective treatment.
ANOVA test has given quadratic models for % phosphate removal. ANOVA results for effluent phosphate removal are represented in Table III. Fisher test was used to evaluate the significance of each factor and their interaction with each other. Values of "Prob > F" less than 0.0500 indicate model terms are significant [8].
TABLE III ANALYSIS OF VARIANCE (ANOVA) TEST FOR EFFLUENT PHOSPHATE REMOVAL (%)
adjusted
Model term |
Source |
Sum of |
p-value |
|
Squares |
Prob > F |
|||
Model |
6203.32 |
0.0035 |
significant |
|
1 |
x1-Current Density |
513.44 |
0.0318 |
significant |
2 |
x2-Time |
1140.51 |
0.0053 |
significant |
3 |
x3-Influent Phosphate |
757.58 |
0.0141 |
significant |
4 |
x1 x2 |
439.53 |
0.0425 |
significant |
5 |
x1 x3 |
0.28 |
0.9519 |
Not significant |
6 |
x2 x3 |
238.55 |
0.1110 |
Not significant |
7 |
x1^2 |
593.55 |
0.0238 |
significant |
8 |
x2^2 |
1742.90 |
0.0017 |
significant |
9 |
x3^2 |
484.14 |
0.0355 |
significant |
Residual |
512.19 |
All model term – R2 = 0.9251, R2
= 0.8288, Model term 1,2,3,4,6,7,8,9 –
(a)
adjusted
R2 = 0.9251, R2 = 0.8501.
Coefficients with p-value greater than 0.1 were considered statistically insignificant and were eliminated from the quadratic equation [8]. Equation (2) was developed after eliminating statistically insignificant term (x1 x3) based on p-value (0.9591 > 0.1) of coefficient for those terms. The p-value for all the model terms were less than 0.05 means model for % phosphate removal was found to be significant with 5% confidence interval. R2 being the coefficient of determination, determines overall efficiency of model prediction. In this study R2 and R2adjusted ensures good correlation with each other. The p-value for phosphate was also 0.01 indicates significance of waste strength on the overall electrocoagulation process efficiency.
Fig 2. Predicted v/s actual values for (a) % phosphate removal
Fig 2 represents comparison of actual and predicted values of
% phosphate removal with good agreement due to presence of all process variables which have significant effect on EC process.
(b)
Fig. 03 Contour plots for % phosphate removal as a function of (a) influent phosphate and time (b) current density and time
Fig. 03 (a) represents interaction effect of influent phosphate and time on % phosphate removal, it is visible that at lower time increase in phosphate up to certain extent shows good removal and then it reduces which at higher time with high phosphate concentration removal also increases due to better balance of pollutant to metal ion ratio. While fig. 03
(b) represents effect of time and current density on the same, where good removal were achieved at moderate time and applied current.
IV CONCLUSION
The study was conducted to understand effect of current density, electrolysis time and initial phosphate concentration on overall phosphate removal efficiency from simulated phosphate wastewater.RSM study showed all the three process variables having significant effect on the EC process
efficiency. It was also concluded that specific concentration of waste strength cancan be treated at specific current density. If more current applied to mild waste there will be wastage of metal electrode and if less current is applied for complex waste there will be poor effluent quality hence optimization of EC process current, time and waste concentration are three necessary process variables due to significant interaction effect.
REFERENCES
-
S. Irdemez, N.Demircioglu, Y.S. Yildiz, Z.Bingul, The effect of current density and phosphate concentration on phosphate removal from wastewater by electrocoagulation using aluminium and iron plate electrodes. Seperation and Purification Technology, 52, 218-223, 2006.
-
A.S. Kopral, The removal of salinity from produced foration by conventional and electrochemical methods. Fresenius Environ. Bull., 11 (12a), 1071-1077, 2002.
-
M.A., Bezerra, R.E., Santelli, E.P., Oliveiraa, L.S., Villar, L.A. Escaleira. Response surface methodology (RSM) as a tool for optimization in analytical chemistry. Talanta 76, 965-977, 2008.
-
S.L.C., Ferreira, R.E., Bruns, H.S., Ferreira, G.D., Matos, J.M., David, G.C., Brandao, E.G.P., da Silva, L.A., Portugal, P.S., dos Reis, A.S., Souza, W.N.L dos Santos, Box Behnken design: an alternative for the optimization of analytical methods. Anal. Chim. Acta., 597, 179-186, 2007.
-
L., Foresti, Anaerobic Treatment Of Domestic Sewage: Established Technologies And Perspectives. Water Sci Technol., 45(10), 181-6, 2002.
-
A.R. Makwana, M.M. Ahammed. Continuous electrocoagulation process for the post-treatment of anaerobically treated municipal wastewater. Process Safety and Environmental Protection, 102, 724-733, 2016.
-
M Kobya,. M Bayramoglu,. M. Eyvaz, Techno-economical evaluation of electrocoagulation for the textile wastewater using different electrode connections. J. Hazar. Mater., 148, 311-318, 2007.
-
D.C. Montgomery, Design and analysis of experiments. seventh ed. Wiley India Pvt. Ltd., New Delhi, 2010.