Performance of Direct Coupled Kijito Wind Pump Drip-Irrigation System

DOI : 10.17577/IJERTV2IS120492

Download Full-Text PDF Cite this Publication

Text Only Version

Performance of Direct Coupled Kijito Wind Pump Drip-Irrigation System

P. A. Kabok1*, D. M. Nyaanga2, M. C. Chemelil2

  1. Lake Basin Development Authority, P. O. Box 1516-40100, Kisumu, and.

  2. Department of Agricultural Engineering, EgertonUniversity, P.O. Box 536-20115,

Egerton, Kenya.

Abstract

A horizontal axis wind pump was directly – coupled to a drip-irrigation system at Rusinga Island, Kenya and its field performance established through a total of 39 test runs repeated at fixed time every day for a period of 20 days. The choice of time of test-runs captured the approximate difference in the wind speed pattern of the area, three times daily for the period of the tests. The power source, for a 900m2 drip- irrigation unit with pressure compensating emitters, was the Kijito wind pump manufactured in Kenya. The unit, designed for mature passion fruits had emitter spacing of 0.9m x 2m limited by market availability, but could be used by trellising. Potential evapotranspiration in the design procedure was by Pan Evaporation method. The other normal irrigation parameters related to climate and soils were calculated or estimated. The aim was to establish use of a wind pump for drip irrigation and its field performance. It was established that wind pump coupled to drip-irrigation system with pressure compensating emitters was technically feasible. Drip-

irrigation efficiencies EU and EUa were acceptable and varied between 93% in the morning to 94% in the afternoon for the 39 test-runs. Wind regime at site, knowledge of wind pump performance characteristics and type of emitter discharge were the critical parameters for the system design and development. Subsequently the design (technology) was considered

realistic, replicable and applicable and would be useful in arid and semi-arid areas or areas faced with weather vagaries but have favourable wind regimes

Key words: Wind Regime, Field performance, Test runs, Pressure compensating Emitters, Irrigation Efficiencies

  1. Introduction

    The Lake Victoria shore (LS) is a narrow band along the Winam Gulf covering Busia, Siaya, Kisumu, Homa Bay and Migori counties, parts of former Western and Nyanza provinces in Kenya. Itis delineated by a 1200 m topographical height above sea level or about 60-km distance off the Kenyan gulf of Lake Victoria shoreline This is bounded by Latitudes 0° 00'00" Equator, 1° 05' 00"S and Longitude 34° 59' 00"E. It has a mild climate, low rainfall with seasons that are distinguishable as dry period (Dec-March), wet or long rains (April-July) and short rains (August- Nov) as described by [22]. The average annual rainfall is less than 1,000 mm and increases towards the highlands to 2000mm per year. The rainfall is bimodal with most occurring during the wet season, the remainder is spread between June and

    November. Evaporation exceeds rainfall in most months except April/May [42].The LS therefore requires supplementaryirrigation in most parts of the year [24].

    It is observed that energy is a critical component in any irrigation undertaking in the region. But energy sources particularly petroleum have problems of high capital costs, operational and maintenance costs, environmental concern, technical know-how and availability. Utilization of renewable energy sources (wind, hydro and solar) do offer attractive options when viable in an area to the small- scale farmer individually or in groups for irrigated agriculture. In this respect, the government of Kenya has in place plans to implement within the region multipurpose hydro-power projects. These will not be adequate for the whole region and particularly parts of the Lake shore. Solar and wind energy though require specific technologies for their exploitation but solar energy in terms of irradiances has high potential. In the case of wind energy potential it is established within the LS[20] that it increases with proximity to the Lake Victoria shore. As such, there are sites within the LS which have existing water pumping windmills and many others where wind speeds are considered favourable for water pumping.

    The wind energy potential can therefore be utilized for water supply and for irrigation. Wind pumps though have capacity limits to pumping that need to be used judiciously especially when under taking irrigation. Drip irrigation among the methods is recognized to have great potential for high irrigation efficiencies [11] [32] but may be affected by standard of the system management and design. It then becomes the best choice for use with the wind pumps for the crop production. In Kenya though, drip- irrigation is in its early stages and mostly limited to backyard activities of horticulture by individual efforts. The system parameters on the other hand need to be designed with the knowledge of the effects of (i) physical factors and (ii) the hydraulic factors to allow

    (i) sound operation and (ii) for checking of the specifications as diagnostic tools for maintenance [2].

    Wind energy conversion systems (WECs) and drip-irrigation technologies as in this case, developed separately in the different parts of the world

    [41] for diverse purposes. The WECs are used in agriculture, water supply, and other industrial applications, but vary on the basis of the state of wind technology, institutional framework and macro-

    economic factors in place [6]. In agriculture WECs are often mainly used for surface irrigation [35] [33] [38]. In Kenya the Global Wind Pump Evaluation Programme [16] [23], describes the potential of WECs in agriculture and particularly could be directed for drip-irrigation.

    Wind energy over the past years however has sometimes been viewed negatively, often associated only with destruction of the environment – buildings, crops, evaporation from reservoirs and soil erosion. Only until recently when characterization studies in various parts of the world by among others: [5][8] [7][17][15][36][34][10][18][19][19][37][29][4]

    enhanced its application methodology as also recorded in [40][41][25][26][14] [9]and[43].The above

    literature is prerequisite reading for the planning and modeling of the wind pump – drip-irrigation. In Kenya use of WECs in this respect is unknown.

    In recognition of such positive views towards application of wind energy in enhancement of energy needs and developments, this study presents a wind pump drip-irrigation system mainly with respect to: –

    (i) a field test-run of a direct coupled wind pump driven drip-irrigation system along the shores of Lake Victoria and (ii) to evaluate the performance of the developed wind pump drip-irrigation system with respect to changing wind speeds and discharges.

  2. Materials and Methods

    The design, installation operation and monitoring of the performance of a wind pump drip- irrigation system require the knowledge of wind regime, wind pump operating characteristics and the crop water requirement (CWR). The system discharge hence should be compatible with the wind pump, the wind regime and cop water requirement. The study aspects thus included system discharge and the performance test run of the drip irrigation system. These are captured in the form of the location, the crop water requirement, the wind speeds, the test run evaluation and the system and the discharge.

    1. Location

      The study was conducted at Tom Mboya High School, Rusinga Island which lies between latitude 00° 30'S and longitude 34° 15'E in Kenya. The wind pump was already installed on a hand dug well located at a site 10m off the Lake Victoria shore. Westward of the site was a long stretch of lake water towards Tanzania and Uganda. Eastward, northward and southward there was an interruption of wind flow by the Rusinga Island ridges that surround the pump site in form of figure C curvature. Approximately 290m away from the wind pump within the school, the designed pilot irrigation unit branched off into a drip- irrigation head control unit (Figure 1), supplied by a 50 mm galvanized iron main pipe.

    2. Water Requirement

      The water requirement for passion fruit at Rusinga was determined according to [39][12] [13] as

      illustrated in Table 2. The evapotranspiration values were calculated based on EPanvaluesderived from data of a nearby Rusinga historical data. This was used to derive and valuestogether with the other parameters as in the Table 2, which were estimated with regard to the prevailing weather and soil conditions of the site. The Pan Method results (Table

      1) as opposed to Radiation, Blarney Criddle and Penman (modified) 1948, was selected for computation of water requirements. The ETo values based on Epan were considered average compared to the other methods, thus used to avoid over irrigation or under irrigation. Also that in the LS region, the equipment and data for the Pan methodismore easily available. The maximum ETo of 5.5 mm/day (Table 1) was determined for the month of March with average gross irrigation water requirement of 4.6mm/day (Table 2). The maximum irrigation interval based on soil and ETcrop parameters was thus calculated (12 days), for the required emitter and system discharge.

      Table 1: Mean daily potential evapotranspiration, Rusinga data: (1972 1981)

      M O N T H S

      METHOD 1 2 3 4 5 6 7 8 9 10 11 12

      Blaney-Criddle

      5.3

      5

      4.1

      3.9

      3.9

      3.8

      3.7

      3.8

      4

      4.4

      4.2

      4.8

      Pan Evaporation

      5.2

      5.3

      5.5

      4.4

      4.1

      4

      4.3

      4.6

      5

      5.2

      4.6

      4.9

      Pen Man (1948)

      Modified

      6.4

      6.6

      6.2

      5.5

      5.1

      5

      5.2

      5.5

      5.9

      6.2

      5.8

      6.1

      Radiation

      6.6

      6.4

      6.2

      5.9

      5.7

      5.4

      5.3

      5.7

      6

      6.6

      6.1

      6.2

      Table 2: Seasonal water requirement of passion fruit at RusingaIsland

      MONTH OF THE YEAR

      Sep

      Oct

      Nov

      Dec

      Jan

      Feb

      Mar

      Apr

      May

      Jun

      Jul

      Aug

      ETO Pan Evap.

      mm/day.

      5

      5.2

      4.6

      4.9

      5.2

      5.3

      5.5

      4.4

      4.1

      4

      4.3

      4.6

      Kc

      0.85

      0.85

      0.85

      0.85

      0.9

      0.9

      0.85

      0.85

      0.85

      0.85

      0.85

      0.85

      Kr

      0.88

      0.88

      0.88

      0.88

      0.88

      0.88

      0.88

      0.6

      0.6

      0.6

      0.6

      0.6

      ETcrop mm/day

      3.7

      3.9

      3.4

      3.7

      4.1

      4.2

      4.1

      2.2

      2.1

      2.0

      2.2

      2.3

      Ks

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      1

      Eu

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      1.11

      IRg mm /day

      4.1

      4.3

      3.8

      4.1

      4.6

      4.7

      4.6

      2.4

      2.3

      2.2

      2.4

      2.6

      IRg L/day/Plant

      36.9

      38.7

      34.2

      36.9

      41.4

      42.3

      41.4

      21.6

      20.7

      19.8

      21.6

      23.4

      NB: Irrigation interval = 5 days, hours per day of irrigation = 12, Area per plant = 1.8 m2.

      Where: Ea = irrigation efficiency, Kc = crop coefficient, Eu = design emission uniformity, Kr = takes care of non- beneficial evaporation which occur in the conventional irrigation methods, Ks = water storage efficiency, ETo = potential evapotranspiration and ETcrop = crop evapotranspiration.

      The parameters of crop water requirement as a factor in the design are summarized in Table 2 and the following equations.

      = . + ….. (1)

      = . × 100 . . (2) Or

      = . . + ….. (3)

      = . . (4)

      Where: IRn = net irrigation water requirement, Lr = extra water needed for leaching, R = water received by the plant from other sources other than irrigation, IRg = maximum amount or depth of water to be applied taking into account suitable reduction as all the soil is not wetted. Fc = Volume moisture at field capacity (%), dm = moisture depletion allowed or desired (%), Rz = soil depth or root zone to be considered in meters, P = volume of the soil wetted as a percentage of the total volume, and b = bulk density of the soil(others as defined in Table 2).

    3. Wind Speeds

      In order to determine discharge for the wind pump, the wind speed historical data was obtained from the Rusinga weather station as in Table 3. The station was within a distance of one kilometer. It wasnot in use but the 2m height wind speed data coarsely indicated the wind regime to be between 2 m/s to 3m/s. The initial wind pump site preliminary wind measurements however showed the range to be within the 3m/s to 4m/s. This was later confirmed from the observed data taken from October to December season. The same time period was used for evaluation of the designed and installed wind pump drip irrigation system. Ordinarily, the established wind speed range from such data wouldbe used to select a wind pump rotor diameter for a system to be established. In this case, the wind pump was installed hence the data together with the Kijito Wind pump performance Table 4 was used for determining the possible discharge from the wind pump. The table is always obtained from the particular wind pump manufacturer.

      Table 3: Mean monthly wind speeds (m/s)

      Month

      N

      Missing

      Mean

      SD

      Jan

      341

      0

      2.94

      0.57

      Feb

      311

      30

      3.08

      0.65

      Mar

      341

      0

      2.99

      0.60

      Apr

      330

      11

      2.60

      0.52

      May

      341

      0

      2.28

      0.43

      Jun

      330

      11

      2.32

      0.38

      Jul

      341

      0

      2.45

      0.45

      Aug

      340

      1

      2.56

      0.43

      Sep

      330

      11

      2.62

      0.41

      Oct

      341

      0

      2.63

      0.52

      Nov

      330

      11

      2.61

      0.66

      Dec

      340

      1

      2.78

      0.47

      Annual Avg

      335.67

      6.3

      2.65

      0.508

    4. System and discharge

      Since the main line wasinstalledfor purposes of water supply to a school/hospital, the drip-irrigation system was however designed, checked for hydraulic characteristics and installed. The Hazen William's

      equation together with Christiansens (1942) modifying factor (F) in [31] and the system discharge(equations 5 and 6) were thus used for the design of the hydraulic system, the manifold and the laterals. The 20% rule by [3] was used in the design process to help achieve the maximum allowable range of uniformity coefficient (Cu) for the drip irrigation.

      The irrigation interval (Ii) and system discharge (Qs) were calculated based on CWR equations 5 and 6 and by specifying the other parameters as listed in Table 5.

      When using the wind pump performance table, they characteristically show the pump head (Hs) in meters, diameter of the rotor, wind speed range (m/s) and the corresponding discharge. Table 4 shows the characteristic arrangement of the wind pump

      operating conditions by the manufacturer. This was however modified in the top row by putting wind speed instead of discharge and adding in columns below; the percent head loss (J) and head loss (H) within the pipeline. The Table 4 of the J, H and Q values is specific to the main line of 50 mm diameter and length of 290m. If the size is changed then the J, H and Q values will vary. The Hs values given include head (m) due to mainline.

      Table 4: Calculated J & H Values – Based on theKijito wind pump table.

      Wind Speed (m/s)

      Head (Hs) (m) 2 3 3 4 4 5

      10

      J

      Q

      H

      J

      Q

      H

      J

      Q

      H

      20

      0.64

      0.79

      1.86

      4.3

      2.21

      12.6

      18

      4.71

      51

      40

      0.2

      0.42

      0.58

      1.25

      1.13

      3.6

      5

      2.38

      14.4

      80

      0.12

      0.21

      0.16

      0.32

      0.54

      0.92

      1.3

      1.17

      3.9

      120

      0.17

      0.38

      0.48

      0.6

      0.79

      1.86

      160

      0.1

      0.29

      0.29

      0.4

      0.58

      1.05

      200

      0.06

      0.21

      0.17

      0.2

      0.46

      0.69

      240

      0.2

      0.38

      0.48

      (J) =The percent head loss (H)=head loss andQ= System discharge

      Table 5: Micro-irrigation System Parameters

      I

      II

      III

      IV

      V

      qd (L/hr.)

      3.5

      18.4

      3.5

      3.5

      3.5

      Qs (m³/hr.)

      0.86

      4.6

      1.7

      0.79

      0.86

      Ii (days)

      3

      12

      5

      3

      3

      Ih (hours)

      16

      12

      12

      7

      16

      Pe (m)

      10

      10

      10

      10

      10

      AP (m²)

      2 x 2

      2 X 2

      0.9 X 2

      0.9 X 2

      2 x 2

      At (ha)

      0.1

      0.1

      0.09

      0.04

      0.1

      Where: (qd)= suitable emitter discharge, Qs =system discharge, Ii=irrigation interval (Ih) = irrigation hours and (At)

      =irrigation area Pe is the pump elevation

      A total head (22.15 m) based on Fig.1 inclusive of H value was used to read out by interpolation the expected main line discharge for the wind regime (3 to 4 m/s).The system total head (drip- irrigation unit, manifold, main line/others) once determined (Hs); the expected discharge was read from the wind pump operating characteristics (Table 4) and compared to the calculated water requirement regime to specify the system discharge (Qs). These would correspond only after varying some of the limiting factors given in Table 5. Instinctively, the wind pump output should be greater than or equal to the calculated

      crop water requirement. All together, the size or length of the pipe can be varied, new values obtained and the discharge corresponded to the water requirement for the system.

      A choice however was made for a suitable emitter discharge (qd), system discharge (Qs), irrigation interval (Ii), irrigation hours (Ih) and irrigation area (At) with regard to Table 5 but pegged on values of qd and Qs. Emitter discharge choice was based on crop spacing and the type available. Change of any of the variables of equations (5 and 6) also

      adjusted the Qs and qd. In Table 5, only and Pe were reasonably held constant among the five option choices, signifying specific emitter and wind pump. The guideline was to design an option with parameters that complied with 3.5 l/hr. emitter size, wind pump/wind regime capacity of 3-4 m/s or water available, crop water requirement and system discharge (Qs) of 1.7 m3/hr restricted by the wind pump.

      brought into active exchange with the water/ the nutrients, the percentage-wetted soil (p). Both the Ks (Table 2) and p (35%) were however estimated.A horizontal axis wind pump was directly – coupled to a drip-irrigation system at Rusinga Island and its field performance established by 39 test runs for a period of 20 days and 10 minutes each. The choice of time of test-runs was such that it captured the difference in the wind speed pattern of the area, three times daily for

      Qs = qd

      . Ii .

      At . 10… (5)

      A

      A

      p

      the period of the tests (10.30, 12.30 and 15.30hrs). The Kijito wind pump was the main power source for the 900m2 drip-irrigation unit with pressure compensting emitters. The unit was designed for mature passion

      From

      = . = . . . 10 . (6)

      The proposed five system optional operational conditions were developed as in Table 5. Option V was selected at preliminary design stage and this changed at installation stage because first, one lateral was damaged and secondly, the largest emitter spacing obtained in the market was 0.9m. Trial option III indicted that the wind pump was able to provide 1.7m³/hr, as opposed to what was expected from the Rusinga historical wind data and Kijito wind pump performance. This meant that for maximum crop water requirement, irrigation was possible for 0.45 ha per season, on 12 hour day irrigation, 5 days interval and system discharge of 1.7m³/sec.

    5. Drip-irrigation field evaluation

      fruits and had emitter spacing of 0.9m x 2m limited by market availability. The Potential evapotranspiration was determined by Pan Evaporation method. The other irrigation parameters related to climate (effective rainfall, ET crop and soils (Leaching Lr) were either calculated or estimated.

      The study used the procedures proposed by [2][39][1] to determine the uniformity of distribution (Eu and Eua)as given in equations 8 and 9. During the test runs, an interval of ten minutes was selected for turn on and off of inflow to the irrigation unit. Pressure readings were only taken at the head control unit because of lack of pressure gauges and proper attachment equipments. A sample field test-run (Table 6) together with field layout (Fig. 1) shows the other necessary test-run details. Plate 1 shows how emitter discharges were done in the field.

      = (8)

      = 100 + (9)

      2

      This aspect of drip-irrigation system evaluated is expressed in the following equations.

      Ea = KsEu or 100,000 Ks Eu. (7).

      Where; Ea, Ks, and Eu are explained under Table 2. The other aspects of drip-irrigation evaluation that could be considered are monitoring of the soil

      Where Eu = field emission uniformity as a percentage, qmin = minimum discharge rate computed from average of the smallest four readings per test run, qavg = average of all the field data emitter discharge rates, Eu= design emission uniformity [21][30], Eua= absolute uniformity as a percentage and qx = average of the highest one-eighth emitter flow rates

      Table 6: Sample field micro-irrigation test run (3.20 – 3.30 pm)

      LOCATION OF LATERAL ON SUBMAIN

      Inlet End 1/3 Down 2/3 Down Far End

      Distribution Location

      Discharge

      Discharge

      Discharge

      Discharge

      on the Lateral (l/hr.) (l/hr.) (l/hr.) (l/hr.)

      A

      3.6

      3.7

      3.5

      3.4

      Inlet End

      B

      3.5

      3.6

      3.4

      3.5

      Time

      (Min)

      10

      10

      10

      10

      Aver.

      3.6

      3.7

      3.5

      3.5

      A

      3.3

      3.3

      3.5

      3.4

      1/3 Down

      B

      3.4

      3.4

      3.4

      3.3

      Time

      (Min)

      10

      10

      10

      Aver.

      3.4

      3.4

      3.4

      3.4

      A

      3.5

      3.3

      3.3

      3.4

      2/3 Down

      B

      3.5

      3.3

      3.4

      3

      Time

      (Min)

      10

      10

      10

      Aver.

      3.5

      3.3

      3.4

      3.2

      A

      2.9

      3

      3.1

      3.1

      Far End

      B

      3.1

      3.3

      3.4

      3.4

      Time

      (min)

      10

      10

      10

      10

      Aver.

      3

      3.2

      3.3

      3.3

  3. Results and Discussions

    1. System Discharge and Design

      The design process/approach is a two-sided concept [20] that must relate system discharge and the crop water requirements (CWR) for the balancing of parameters in equations 5 and 6.Headloss (Hs) for the system in Fig. 1 (22.15m) included: Pe = 10m, topographical head (6m), system frictional head loss (1.6m), mainline losses (7.7m) and 1.45m for the other losses due to additional equipment added to the system (filter, water meter etc.). Table 3as a first guide to wind speed characteristics of the area, showed that mean monthly wind speeds varied between 2.32 m/s in June to 3.1 m/s in February. Deviations below the mean lower than 2m/s were in the months of May, June and November. It was observed that supplementary irrigation within the lakeshore would be most necessary between August toMarch, when

      water deficit exists Monthly mean wind speed range, considering yearly average and monthly standard deviations is observed to be between 2-3 m/s (Table 3).

      From the wind speed range (2-3m/s), wind pump discharge size (Qs) and using Table 4, the system discharge was determined by interpolation as 0.62m3/hr. for a total head of 22.15m lying between 20m and 40m total head. This however, could not be sustained by any of the options in Table 5. Test runs at site indicated that wind speeds were actually in the range of 3 – 4m/s (Table 6). Option III (Table 5) was therefore selected for the operation because the system discharge of wind pump was 1.7m3/hr. based on the water requirement.

        1. Field Efficiency Tests

          A total of 39 test runs were carried out three times daily in the month of November. The choice of time of test-runs captured the approximate difference in the

          wind speed pattern of the area, three times daily for the period of tests.

          Results of the average discharge of the test runs, the amount of water passing to the irrigation unit, pressure at the control head and the calculated emission uniformity (Eu%) are given in Table 7. Table8presents the calculated minimum discharge for the test runs, coefficient of variation (CV) of discharge of test runs, average wind speeds of the one hour measurement period that covered test run interval, and the absolute emission uniformity of the test runs calculated using equation (9). Sample result of a test run and calculations are given in Table 6

          The efficiencies given in Tables 7 and 8 are the result of equations 8 and 9. Average discharges in the respective tables were the result of sample test-

          runs, example given in Table 7. The sample test-run shows location of laterals on the manifold and the distribution points on the lateral. The average of two adjacent discharge points denoted by letter A and B was taken as a single discharge point and resulted into sixteen discharge points within the micro-irrigation unit. The averages of the discharge points for each test-run time were then tabulated as in Table 7. The minimum discharge expressed as the average of the four lowest readings within the test-run unit was in turn tabulated as in Table 8. The average and minimum discharge of the two forms of efficiencies, for each day of the tes-run irrespective of time of the day is further shown in Figures 3 and 4. Time system of emitter discharge and uniformity coefficients with regard to the time of the day are illustrated in Figure 5.

          Table 7: Emission uniformity coefficient micro-irrigation test runs RusingaIsland

          Date

          Average Discharge ml/10 min/emitter

          Average Discharge at Control Head m3/10min

          Pressure at Control Head

          (bar) EU%

          Time

          10

          12.3

          3.2

          10

          12.3

          3.2

          10

          12.3

          3.2

          10

          12.3

          3.2

          3

          496

          570

          533

          0.34

          90

          91

          95

          4

          528

          536

          549

          0.32

          0.21

          0.34

          94

          94

          93

          5

          551

          577

          535

          0.22

          0.34

          0.47

          93

          93

          95

          6

          493

          531

          538

          0.31

          0.21

          0.31

          94

          95

          96

          9

          570

          534

          560

          0.23

          0.47

          0.43

          95

          90

          93

          10

          557

          533

          561

          0.23

          0.33

          0..39

          91

          95

          91

          11

          534

          553

          550

          0.23

          0.34

          0..33

          > 0.8

          > 1

          > 1.2

          91

          95

          97

          12

          538

          534

          552

          0.33

          0.43

          0.25

          > 0.8

          >1

          >1.8

          94

          94

          92

          13

          531

          535

          562

          0.43

          0.33

          0.24

          0.4 -0.6

          1-1.6

          >1.6>

          94

          94

          94

          14

          509

          519

          530

          0.31

          0.43

          0.31

          >0.4

          1.2 -1.8

          1-1.8

          94

          95

          95

          16

          565

          517

          570

          0.37

          0.3

          0.24

          0.8-14

          0.4

          1.4-2

          94

          95

          96

          18

          545

          556

          558

          0.23

          0..34

          0.44

          0.8-1.6

          0.6

          1-2.4

          96

          95

          94

          19

          524

          543

          600

          0.32

          0.26

          0.45

          0.6

          2-Jan

          94

          96

          97

          Aver.

          534

          541

          553

          0.3

          0.33

          0.35

          93

          94

          94

          Table 8: Absolute emission uniformity coefficient, micro-irrigation test runs RusingaIsland.

          Date

          Av. Min. discharge ml/10 min/emitter

          Coefficient of variation (CV)

          Test Run Average

          Wind Speed EUA

          Time

          10

          12

          3.2

          10

          12.3

          3.2

          10

          12.3

          3.2

          10

          12.3

          3.2

          3

          448

          518

          1015

          8.1

          6.6

          4.3

          3.2

          4.1

          9.4

          90

          91

          95

          4

          495

          502

          513

          5.1

          5.1

          5.8

          3.2

          2.2

          3.2

          93

          93

          93

          5

          511

          549

          506

          5.8

          3.7

          5

          4.2

          3.9

          3.6

          93

          95

          93

          6

          465

          502

          516

          4.2

          4.2

          4.1

          2.8

          2.8

          3.9

          94

          95

          95

          9

          543

          479

          521

          3.8

          8.1

          4.9

          4.5

          3.9

          6.2

          94

          91

          94

          10

          505

          527

          511

          6.4

          3.9

          7

          4.5

          3.5

          91

          95

          92

          11

          487

          486

          533

          6.4

          5.7

          3.1

          2.4

          5

          91

          92

          96

          12

          504

          504

          509

          5.3

          4.6

          6.1

          2.6

          3.9

          3.1

          93

          93

          91

          13

          497

          502

          530

          6.1

          4.3

          4.3

          1.7

          3.8

          4.1

          92

          94

          94

          14

          479

          493

          505

          4.3

          4

          4

          2.1

          3.5

          4.6

          94

          94

          94

          16

          533

          491

          547

          4

          4.6

          4.2

          3.7

          3

          3.6

          94

          94

          94

          18

          521

          526

          525

          4

          4.6

          4.5

          2.4

          2.9

          4.3

          95

          95

          94

          19

          492

          522

          579

          4.9

          3.1

          3

          1.9

          3.6

          2.9

          94

          96

          97

          Aver

          498

          508

          523

          5.3

          4.8

          4.6

          3

          3.5

          4.4

          93

          94

          94

          Table 9 summarizes the aalysis of variance for time of tests of 10.30a.m, 12.30pm and 3.20pm. A one-way analysis of variance was used to check on the difference that could occur in the average emitter discharges. The computed F-value of 2.93 and tabulated was 3.27 and the probability (P-value) at 5% significance level was 0.661. This result shows that the difference in average discharge was not significant. This study therefore concludes that the discharge averages were constant at head control unit irrespective of pressure developed by the wind pump at different wind speeds. This confirms consistency in performance of the system.

          Subtracting minimum discharges in Table 9 from average discharges in Table 8 shows that the closer the difference to the standard deviation 21,

          Table 9, the higher was the uniformity coefficient achieved in percent. This is exhibited in Figures 3 and

  4. Any difference that was lower than two standard deviations showed uniformity coefficient lower than 93%. Increase or decrease in system discharge cannot be perfectly matched to the efficiency coefficients. This could be attributed to wind speed, the pressure compensating nature of the emitters and the water held in the pipe line which could be pushed to the unit at minimal wind speed. Owing to the large interval of wind speed (1hr) measurements and the small test-run interval, this effect could not be explicit. But it is evident that the system efficiency did not follow wind speeds, it depended on the difference between the minimum and the average discharge with regard to the standard deviation. The coefficient of variation (Cv) was therefore also influenced by this phenomenon.

Table 9: Analysis of variance of mean emitter discharges

Sample

Time

Mean

Size

Group Std Deviation

10.30 am

533.92

13

24.336

12.00 pm

546

13

19.425

3.20 pm

553.69

13

18.741

Total

544.54

39

20.983

Degrees of Freedom

Sum of Squares

Mean Square

F

P

Time

2

2582

1291

2.93

0.0661

Error

36

15849

440.27

Total

38

18431.7

F0.05 , 2, 36 = 2.93, Cases included = 39, missing cases = 0

Water supply at control head varied between1.8 m³/hr. to 2.1m³/hr. (3.4%) This meant that an average of 1.8m³/hr. minimum water was available from the wind pump. It supported the system design discharge choice of 1.7m³/hr. (Table 4). A one-hour average wind speed was between 3.0m/s to 4.4 m/s, suggesting that 2- 3 m/s annual wind regime chosen earlier had to be revised to a regime of 3-4m/s. Pressure at the head control unit varied by up to 75% but was observed as non-significant (Table 9) for the emitter discharge. This was confirmed by the insignificant variations by the test runs average discharge and test run minimum discharge, which increased from 534 to 553 and 498 to 523 milliliters respectively. These varied with time (Fig. 5) and day of test (Figures 3 and 4) but showed in Table 8, the efficiencies, which remained constant at 93% in the morning and 94% in the afternoon. This is attributed to the temporal variations.

The average test run coefficient of variation (Cv) decreased from 5.3% to 4.6%, showing some improvement though small. This pointed out that increased average wind speeds in the morning meant improved average emitter discharges (Fig. 5) with time of the day, which corresponded with increased wind speed within the day. The variations of system discharges, efficiencies, and wind speed were consistent as shown in Figures 3 to 4 and Tables 8 and

9. Wind regime therefore, as the prime mover was consistent. The design approach and approaches used can be upheld and replicated as the pressure and discharge variations were well regulated by the

pressure compensating emitters. However, seasonality could affect results because of change of wind regime as is exhibited in the day variations.

It was found by [39] that values of EuandEua determined in the field were ranging from 85% to 95%. [2] on the other hand suggests "the general criteria for EuandEua values as; 90% or greater, excellent; 80 to 90%, good; 70 to 80%, fair; and less than 70%, poor". It can be deduced from the foregoing that the drip-irrigation unit performance was good based on trends above in spite of pressure variation due to wind speeds. The performance could also be attributed to the kind of emitter used (self- compensating) with an exponent value of nearly zero, screens that were at the head control unit at the 50 mm, Arad water meter at the foot of the wind pump, and the water meter at the head control unit that reduced the emitter blockage.

3.3. Design Challenges

The design process required that parameters were either accurately determined or estimated dependent on the conditions for implementation of the wind pump drip-irrigation system. Primarily the parameters are: location of the system, type of crop, soil type and the calculation thereof for the gross water requirement (IRg). Though the hydraulic calculations are routine process, challenges are occasioned mostly because of the spatial and temporal variations. ETo in

itself requires an established method for a region (e.g. PenMan Equation, Radiation, Pan Evaporation and Blaney-Criddle Methods) that accurately estimates it in a local area. The Ground cover and crop coefficient (Kc) also need knowledge of the crop in terms of its development stages within a management and the climatic conditions. Others include the percentage- wetted portion of the total soil volume (WP) and the factor Kr that take care of the non-beneficial evaporation, which occur in the conventional irrigation methods. In order to account for these, research is necessary for every locality of the region. Economic conditions often do not allow for this more so in the developing world. This is coupled with the wind regime, because it should be synchronized to only a particular design of a wind pump.

Equivalently, there are various approaches to the characterization of wind regime, problems with data availability, choice and use of predicting equations, density and sustenance of measurement facilities especially in the developing countries. Hence before embarking on the design process adequate understanding of the conditions of the drip-irrigation, wind, wind pump and their performance need a thorough situational review. Figure 2 may also serve to explain this. It also symbolizes a sprinkler design where emitter is the sprinkler head, motorized pump becomes the wind pump (WP) and wind regime (WR) serves to illustrate the horsepower of the pump, which may be varied for the same environment. The challenges may be quite specific but the design process illustrates the approach and key parameters required. Another factor was the water availability and quality, availability defined by crop water requirements and wind pump operating output at the available wind regime (Qs). Water quality for the system was taken care of by the preliminary assessment and the introduced appropriate filters.

  1. Conclusion

    This study has demonstrated that a wind pump directly coupled to a drip-irrigation system is feasible. The approach of synchronizing water requirement with respect to the plant for an irrigation unit area (system discharge), wind pump output based on its characteristics and wind regime and the emitter discharge is considered a new development for the use of the two otherwise separate systems.

    The emission uniformity coefficient (Eu) and the absolute emission uniformity coefficient (Eua) obtained in this evaluation were higher than 90% and confirmed that use of wind pump with pressure compensating emitters performed acceptably equally well and gave equally comparable (Eu and Eua) values. Morning or afternoon wind speed variation resulted into a one percent difference of 93% to 94%. This meant that the choice of wind pumps performance range; design criteria and the efficiency of irrigation achieved were acceptable for use in a drip-irrigation system.

    Wind speeds at the study site and period concentrated between 34 m/s and slightly greater for the 10m level anemometer observations. Application oftheKijito wind pump was therefore feasible considering its rated performance range (3 to 4m/s) as it was sustained. Drip-irrigation system parameters were however observed to relate or affect one another iteratively.

    Drip-irrigation uniformity coefficient achieved with use of pressure compensating emitters was reasonable and within acceptable range. Applications with different wind pump rotor diameters; will need adjustment of irrigation area because each rotor diameter performs differently in the same wind regime. The behaviour of non-pressure compensating emitters forms another important test area, particularly to see the effect of wind speed variation with discharge along the laterals. Wind tunnel test runs or other method of test would also be of interest in this regard.

  2. References

[1]. Barragan, J., Bralts ,V. Wu, I.P. (2006). Assessment of Emission Uniformity for Micro-irrigation Design. Elsevier Ltd.Volume 93, Issue 1, Pages 8997.

[2]. Bralts V.F (1980); Field performance and Evaluation in design and operation of farm irrigation systems, American Society of Agricultural Engineers.

[3]. Benami A. and Ofen A., (1983); Irrigation Engineering, Sprinkler, Trickle, Surface Irrigation. Principles, Design and Agricultural Practice. Irrig. Eng. Sci. Publ.,

Haifa, Israel 257pp

[4]. Buhari., A. M, Argungu., G. M. and Momoh.

M. (2013). Assessment of Wind Energy

Hants. RG27OPR, UK 108pp

Potential for Electricity Generation inSokoto,

[17].

Justus, C. G., Hargreaves, W. R. &Yalcin A.

NigeriaInternational Journal of Engineering

(1976); Nationwide Assessment of Potential

Research & Technology (IJERT) ISSN:

Output from Wind Power Generators, Journal

2278-0181 www.ijert.org Vol. 2 Issue 6.

of Applied Meteorology, 15, 673 678.

[5].

Carruthers, N. (1943); Variation in Wind

[18].

Justus C. G., Hargreaves, W. R. Mikhail, A., &

Velocity Near the Ground, Quarterly Journal

Graber, D. (1978); Methods for Estimating

of the Royal Meteorological Society, 289

Wind Speed Frequency Distributions, Journal

300.

of applied meteorology 17,. 350353.

[6].

Chavan., D. K., Priyanka., A. C, and Sachin.,

[19].

Justus, C. G., Mani, K. and Mikhail, A. S.

V. M (2012). Energy Harnessing By Various

(1979).Interannual and Month to Month

Non-Conventional Wind-Turbine Designs and

Variations of Wind Speed, In: Journal of

Augmentation of Its Aerodynamic Efficiency.

Applied Meteorology, 18, PP. 913-920.

International Journal of Engineering Research

& Technology (IJERT) Vol. 1 Issue 10, ISSN: 2278-0181.

[7]. Chipeta G.B. (1976); A study of Wind Power Availability in Kenya, MSc Thesis, Department of Meteorology University of Nairobi, Kenya.

[8]. Deacon, E. L. (1948); Vertical Diffusion in the Lowest Layers of the Atmospheric, Quarterly Journal of the Royal Meteorological Society, 75, 89 103.

[9]. De Jongh, J.A. and Rijs, R.P.P. (2004).Wind Resources, World Bank Technical Paper Number 101.

[10]. Doran, J. C. &Verholek, M. G. (1978); A Note on the Vertical Extraction Formula for Weibull Velocity Distribution Parameters. Journal of applied meteorology, 410 412,

[11]. Dorata Z. H. and Izuno F. T., (1997); The Basics of Micro-irrigation in African Farming.

[12]. Dorenboss J., Pruit W. O., (1977); Crop Water Requirements. Irrigation and Drainage paper No. 24 F.A.O. ROME 144pp.

[13]. Enciso J. and Michael .M. (2004).Using renewable energy to pump water. Texas Cooperative Extension, Texas A&M University System, College Station, TX. Reference No. L-5457.

[14]. Gipe Paul, (1993); Wind Power for Home and Business. Renewable Energy for the 1990's and Beyond. Chalsea Green Publishing Company. White Rivers Junction, Vermont413pp.

[15]. Hennessey J.P., (1977); Same Aspects of Wind power Statistics, Journal of Applied Meteorology, 16, 119-128.

[16]. It Power Ltd, (1987); Global Wind power Evaluation Programme, Kenya.Eversley,

[20]. Kabok, P. A. and Chemelil, M.C. (2001).The Relationship between Wind speeds and Kijito Wind pump Discharges in Rusinga Island, Lake Victoria: Journal of CivilEngineering, JKUAT Vol. 6, 27-43.

[21]. Keller J. and Karmeli D., (1975); Trickle Irrigation Design Parameters. Trans Amer. Soc. Agri. Eng. 17(4): 678-884.

[22]. KMD (1984) Managing risk and reducing and reducing vulnerability of agricultural systems under variable and changing conditions. The International Crops Research Institute for the Semi-Arid Tropics (ICRISAT) and Kenya meteorological department (KMD).

[23]. Kruger Consult (1993); The Wind Energy Sector in Kenya, Nairobi.

[24]. LBDA, (2005). Report on investment opportunities.

[25]. LE Gouriérés D. (1982); Wind Power Plant, Theory and Design Pergamon Press, England. 285 pp

[26]. Lysen E.H (1982); Introduction to Wind Energy Basic and Advanced Introduction to Wind Energy with Emphasis on Water Pumping Wind pumps.Amerfoot/The Netherlands 310 pp.

[27]. Mage, D.T. (1979); Comments on Frequency Distribution of Wind Speed near the Surface, Journal of Applied Meteorology, 18, .1089 1091.

[28]. Oludhe C. and Ogallo L. (1989); Statistical Characteristics of the Surface Winds over Kenya. Journal of Applied Statistics, 16, 331

334.

[29]. Oludhe, C. and Ogallo, L. (1990); Vertical Variation of Wind Power, Discovery and Innovations, 2, 73-79.

[30]. Pankaj Sharma, (2013).Hydraulic Performance of Drip Emitters under Field Condition. IOSR Journal of Agriculture and Veterinary Science (IOSR-JAVS): 2319- 2380, ISBN: 2319-2372. Volume 2, Issue),

PP 15-20.www.iosrjournals.org accessed on 8th August 2013.

[31]. Sadeghi, S. H., Mousavi, S. F., Gheysari, M. and Sadeghi, S. H. R. (2011). Evaluation of the Christiansen method for calculation of friction head loss in horizontal sprinkler laterals: effect of variable outflow in outlets. Water Eng. Dept., Isfahan University of Technology of Iran Transactions of Civil

Engineering, Vol. 35, No. C2, pp. 233- 245mousavi_sf@yahoo.com accessed on 28th August 2013

[32]. Seleshi, B.A., Philippe, L. and Taffa.T. (2009).Pumps for small-scale irrigation

.Improving Productivity and Market Success (IPMS) of Ethiopian farmers project. International Livestock Research Institute (ILRI), Addis Ababa, Ethiopia

[33]. Synman N. (1980); Windmill – A New Concept.

In Farmers Weekly.

[34]. Stewart, D. A. &EssenWanger (1978); Frequency Distribution of Wind Speds Near the Surface Journal of Applied Meteorology, 17, 1633-1642

[35]. Stout B.A. (1990); Handbook of Energy for World Agriculture. Elsevier Applied Science.

[36]. Takle, E. S & Brown J. M. (1977); Note on the Use of Weibull Statistics to Characteristics Wind Speed Data, Journal of Applied Meteorology, 17, 556 559.

[37]. Van Der Auwera, L., De Meyer, F. &Malet,

L.M (1980); The Use of Weibull Three Parameter Model for Estimating Mean Wind Power Densities, Journal of Applied Meteorology, 19, 819825.

[38]. Van Vilstren and A.E.M. (1980)Wind Mills for Water Lifting. A Feasibility Study, Vol I & II

– Report Written to the Ministry of Agriculture Land Development Division.

S.S.I.U NRB. Tool Foundation Amsterdam.

[39]. VermeirenI. AndJobling E.A., (1980)Localized Irrigation. Irrigation and Drainage paper No.

36. F.A.O. ROME. 203pp

[40]. W M O, (1964); Sites for Wind Power Installations, Technical Note No 63 (WMO-

NO 156.TP.76). 38pp

[41]. W M O, (1981); Meteorological Aspects of the Utilization of Wind As an Energy Source. Technical Note NO 175 (WMO.NO.575)

Geneva. 180pp

[42]. Xungang Yin, Sharon E. Nicholson (2000). On the diurnal cycle of cloudiness over lake Victoria and its influence on evaporation from the Lake.Department of meteorology, Florida state university, Tallahassee. Florida 32306, USA.Mamoudou .B.A. Department of meteorology, university of Maryland, college park, Maryland 20742. USA. Hydrological sciences (45) 3

[43]. Yao, F., Bansal, R.C., Dong, Z. Y., Saket, R. K. and Shakya, J. S. (2011).Wind Energy Resources: Theory, Design and Applications, Handbook of Renewable Energy Technology

© world scientific publishing co pte. ltd. http://www.worldscibooks.com/environsci/74 89.htmlAccessed on 26th August 2013.

Plate 1: Water from Emitters

999.565

999.565

998.365

998.365

998.665

998.665

1000.165

1000.165

1000.465

1000.465

999.865

999.865

999.265

999.265

998.965

998.965

End plug Laterals

TBM

WIND MILL

Emitters

998.855 999.255

999.555

999.855

1000.225

MURRAM ROAD FROM MBITA

MURRAM ROAD FROM MBITA

MAIN LINE

1000.765

1000.765

Head control unit

1 inch surface pipe

Manifold

Junction

2 inch undeground pipe

0 5 10 15 m

LEGEND

TBM

Existing Pipe from Windmill School fence

Temporary bench mark Telephone post

Tree

SOURCE

  • Field Survey by the Researcher in May 2007

  • Cartographic design and processing by Okotto-Okotto J.

1000.765

Contours

Study plot boundary

Fig. 1: Demonstration Plot for Drip-irrigation System at Tom Mboya Sec. School

A

ABSTRACTION

SINK

ABSTRACTION

SINK

IRD

MF

IL

MF

IL

WP WR

CROP

CROP

ED

ED

CWR

SD1

SD1

SD2

A

SD1 SD2

SD1 SD2

IRD to change design:- qd or Qs or Ih or Ap or At or wind pump (Pe)

Stop

SD1>> SD2

Stop

SD1>> SD2

A

A

IRD to change design:-qd or Qs or Ih or Ap or At or wind pump (Pe)

Figure 2: Wind Micro-irrigation Design Illustration Chart

Where IL = irrigation location, MF = Manufacturer, WP = wind pump, WR = wind regime, CWR

= crop water requirement, ED = Emitter discharge, SD1 = Wind pump rated discharge, SD2 = Discharge based on crop water requirement, IRD = Irrigation Designer.

      1. WP on the INPUT (Abstraction) side corresponds to CWR on the SINK side.

      2. SD1 should be just greater or equal to SD2 dependent on design efficiency.

      3. The chart (Fig. 1) can be applied elsewhere for the design of a sprinkler irrigation but developed for a wind pump (horizontal axis) micro-irrigation

560

550

540

Discharges

Discharges

530

520

510

500

490

480

Day system (Average and Minimum) Discharges

0 5 10 15 20

Day

Av. Disch.

Av. Min. Disch.

560

550

540

530

520

510

500

490

480

470

560

550

540

530

520

510

500

490

480

470

96

95

94

93

92

91

90

96

95

94

93

92

91

90

DISACHARGES

DISACHARGES

% COEFICIENT

% COEFICIENT

Fig. 3: Day System (Average and Minimum) Emitter Discharges

96

95.5

95

% Coefficient

% Coefficient

94.5

94

93.5

93

92.5

92

91.5

Fig. 4: Day System (EU% and EUA) Uniformity Coefficients.

AVER DISCH MIN. DISCH

AVER DISCH MIN. DISCH

10.00

10.00

12.30

12.30

15.20

15.20

TIME (24 Hour)

TIME (24 Hour)

EU% &EUA

EU% &EUA

10.00

10.00

12.30

TIME (24 Hour)

12.30

TIME (24 Hour)

15.20

15.20

Day Variaton of Eua and Eu%

0 5 10 15 20

Day

EUA EU%

Fig. 5: Time System of Emitter Discharges and Uniformity Coefficients

Leave a Reply