Pre-Stressed Analysis of Plastic Pump-Housing
( Static Structural Analysis snd Pre-Load Test)
Saideepak Maligi
B.Tech .Student Department of Mechanical Engineering Santhiram Engineering college, Nandyal
JNTU University, Hyderabad, India
Abstract Pump-housing consists of a 5 part assembly representing an impeller type pump. Our primary goals are to analyze the assembly with a preload on the belt of 100N to test in this we are observing that the impeller will not deflect more than 0.075mm with the applied load and also plastic pump housing will not exceed the materials elastic limits around the shaft bore using the FEA software ANSYS WORKBENCH 16.1 . This Analysis can be made by taking some assumptions Belt load is assumed to be at the contact surface of Belt and the pulley, which can be given with Bearing load in positive X-direction, Pump house is rigidly mounted to the rest of the pump assembly, Assuming wall condition at the face of Housing used compression only support. In this analysis we also carryout a sub-modeling analysis on Plastic Housing for accurate resolution of von-Mises Stress. Sub-modeling was carried out to reduce the stresses at the area of interest. It was done by preparing the geometry and preparing a cut boundary constraint and importing the loads and refining the mesh. To conclude Pre- stressed analysis was carried out using a static structural and frequency ranges from 100 to 1000Hz
Keywords Analysis, Modalanalysis, Von Mises Stress, Submodeling
-
INTRODUCTION
Static Structural Analysis of part assembly pre-load test for is made in this pump consists of a 5 part assembly representing an impeller type pump. Our primary goals are to analyze the assembly with a preload on the belt of 100N to test so that the impeller will not deflect more than 0.075mm with the applied load and also to observe the use of a plastic pump-housing will not exceed the materials elastic limits around the shaft bore. In later stages this pump-housing should undergo pre-stressed Modal analysis and also sub- modeling analysis on Plastic Housing for accurate resolution of von-Mises Stress. But throughout the whole process the major area of concern which is always to be kept in mind is the safety of the pump-house. that can be achieved by performing good number of iteration in the designs as per the results obtained after the analysis of the pump-house So this paper is all about what and all are the necessary tests which are to be performed on the pump-housing and how to optimize the results in order to ensure the safety of the housing
-
DESIGNING THE PUMP-HOUSING
Before getting started with the analysis, first of all it is necessary to know the basic steps which are being involved in designing pump-house It is always advised to
go through all the rules and constraints by keeping which in mind pump-house has to be built After designing the basic structure of the pump-house in any of the designing
software e.g. SOLIDWORKS, CATIA, etc., the next challenging task is to select the appropriate material for making the parts of the pump is the only way by giving strength to safety of the pump-housing can be ensured. While selecting the material for the pump one has to be
very careful as the selection of material also plays a very vital role in giving strength to the body of the pump. As there are a number of materials which are available for
making the pump, there are always a lot of confusions in selecting the best one for us. So materials can be selected on the basis of different parameters such as, its availability in the market, cost of the material, properties of the material and its strength to weight ratio.
Fig.1. imported pump view 1
Fig.2. imported pump view 2
A . Assumptions to be made before importing the geometry to ANSYS 16.1 software
-
Belt load is assumed to be at the contact surface of Belt and the pulley, which can be given with Bearing load in positive X-direction.
-
Pump house is rigidly mounted to the rest of the pump assembly
-
Assuming wall condition at the face of Housing used compression only support
TABLE.1. Properties of various materials
Name
Density g/cm3
Young Modulus
Poisson´s Ratio
Structural Steel
7850
200
0.3
polyethylene
950
78
0.46
In this assembly
PUMP-HOUSING material is taken Polyethylene remaining IMPELLER,PULLEY,SHAFT AND NUT are taken
structural steel
-
-
MESHING
In this project we use both global mesh and local mesh settings for reducing the stresses and improve the stiffness of geometry.
Fig.4.contact 1
Fig.5.contact 2
-
BOUNDARY CONDITIONS
Now a fixed support is applied to faces of holes by creating a named selection of same size and type. And a compression only support to the face of the pump housing as we assumed that it is fixed to wall surface and by compression only supports moving in ,out are restricted. Bearing load of 100N is selected on the circular face of a pulley in positive x direction.
-
Connections
Fig.3.Fully meshed pump
Fig.6. Bearing Load
A bearing load of 100N is applied on the belt so the required tension is created on the pump housing
As this is a linear problem only bonded and no seperation contacts are used. By default it has bonded contact then we changed no separation contacts for pump house to pulley
,pump house to shaft and mp house to impeller. Rest all contacts are by default bonded
Fig.7.Fixed Supports
Fig.8. Compression Support
-
-
RESULT
By checking the impeller deformation we can verify that one of our goal is met. The maximum deformation is approximately to 0.0231(goal<0.075mm)
Fig.9. Impeller Deformation
As we apply the boundary conditions and we find the stress and deformation.When the solution is complete highlight the results to plot each. While the overall plots can be used as reality to verify our loads. The maximum high stress is 0.61918 Mpa
Fig.10. Total Deformation
A . pre-stressed model analysis
pre-stressed model analysis is carried out with a large deflections on and the no of mode shapes given were 6 and the frequency range was given from 100 to 1000 hz (given) . The mode shapes and deformations are as follows.
Fig.11. MODE 1
Fig.12. MODE 2
-
sub-modelling
Sub modelling was carried out to reduce the stresses at the area of interest. It was done by preparing the geometry and preparing a cut boundary constraint and importing the loads and refining the mesh
Fig.13.SUB- MODELLING 1
By scoping the results of stresses on pump housing in full model and sub model the values got increased(0.85 to 0.94)
Fig.14. SUB-MODELLING 2
VII. CONCLUSION
The impeller deflection is less than 0.075mm The plastic pump housing materials elastic limits were
less than 25Mpa.Pre-stressed analysis was carried out using a static structural and frequency ranges from 100 to 1000Hz.Sub modelling analysis was carried out.