Remuneration of Rain Water Harvesting in Shekahwati Region, Rajasthan

DOI : 10.17577/IJERTV1IS7341

Download Full-Text PDF Cite this Publication

Text Only Version

Remuneration of Rain Water Harvesting in Shekahwati Region, Rajasthan

1Aakash Sharma, 1Bhavana Goswamee, 1Ranjan Kumar, 2Abhishek Agarwal

1Department of Mechanical Engineering, Shridhar University, Pilani, Rajasthan

2Asst. Professor, Department of Mechanical Engineering, Shridhar University, Pilani, Rajasthan

Abstract-

The aim of this paper is to provide the all details about the rain water harvesting. For this purpose we have selected the building of Department of Mechanical Engineering at Shridhar University , Pilani. Study shows that the year 2002 was the worst with rainfall being 62.3% less than mean annual rainfall. Since it is quite easy to collect rainwater falling on roofs, rooftop rainwater harvesting is the process of collecting rainwater falling on rooftops in a tank or sump for future productive use. This depends on the rooftop area, the size of the tank and the rainfall at that place. The existing roof is made use of to collect rainwater. Since rainwater is pure as it falls from the sky it is necessary that the roof be kept clean for it to remain pure when it is collected. It is estimated that annual water harvesting potential from 1402.23 m2 roof is 5,45,614.003 litres.

  1. Introduction- Chirawa is located at 28.25°N 75.63°E .It has an average elevation of 294 metres (965 ft). Chirawa is one of the oldest towns of Shekhawati region.[2]The Rajasthan Legislature approved Way to transform Shridhar University

    Table1- Land Use statics

    Pilani is just on the Outskirts of Chirawa. Jhunjhunu district is located in the extreme north eastern part (bordering Haryana state) of Rajasthan State and lies between 27°38 & 28°31 north latitudes and 75°02 &76°06 east longitudes. It covers 5928 sq.km. of geographical area. The population of district is 19,13,689 based on Census,2001 including 1518573(79.35%) rural and 395116 (20.65%) urban. The density of population is 323 persons/ sq.km. Jhunjhunu district is covered under mainly Sekhawati basin and north western part falls under the outside the basin i.e. having inland

    drainage. The area is drained mainly by Kantli river. The area in the south eastern part is drained by Singhana river and a small area in south western corner of district is drained by Budhi nala. All the rivers/nalas are ephemeral in nature and flows in response to heavy precipitation during monsoon.

    and north western part of district has inland drainage. Reappraisal hydrogeological survey was carried out in Jhunjhunu district in parts during 1980-81, 1987- 88 and1996-97. Ground water management studies for the entire Jhunjhunu district were carried out during 1999-2000. The term rainwater harvesting is usually taken to mean the immediate collection of rainwater running off surfaces upon which it has fallen directly.

  2. RAINFALL AND CLIMATE

    The climate of the district can be classified as semi- arid. It is charaterised by very hot summers and very cold winters with poor rainfall during south-west monsoon period. In May and June, the maximum

    o

    temperature may sometimes goes up to 48 C. The

    potential evapotranspiration rates are quite high, especially during May and June.[3] The total annual potential evapotranspiration is 1502.6mm. The mean annual rainfall of the district, based on 36 years data (1971-2006), works out to be 485.6mm. However normal annual rainfall (1901-71) of the district is 459.5mm. It can be inferred that the rainfall in the district has significantly increased in the recent years.

    Soil

    % covered in district

    Sand dunes

    2149 sq.km.area forming

    36.25%

    Lithosols and regisols of hills

    329 sq.km.area forming 5.55%

    Red desertic soil

    468 sq.km.area forming 7.90%

    Older alluvium

    316 sq.km.area forming 5.33%

  3. SOIL TYPES – The distribution of soil is given below.

    Desert soil

    2666 sq.km.area forming

    44.97%

    Table2-The distribution of soil

    The study of water table contour map reveals that general direction of ground water flow is from the hills areas in south and south eastern to northern side except 12 in the south eastern part. In south eastern hilly areas of the district, movement of ground water is The dynamic ground water resources as per ground water estimation as on 31.03.2004 is furnished below.

    Table3-The distribution of soil

    Fig.1-Water Level Trend map of District[4]

    Comparatively fast due to steep gradient while it is considerably slow in the remaining parts covered by alluvial formations having gentle gradient. The average hydraulic gradient of ground water table is southern part is 4m/km and is about 2 to 3 m/km in the northern part. Exploratory bore hole data drilled in alluvial formation has indicated that depth of drilling ranges from 27.74 to 135.00 m having depth of wells from 30 to -115m. The discharge of wells varies from 160 to 2733 lpm having moderate drawdown. The transmissivity value of aquifer varies

    2

    from 100 to 1915 m /day and storability from

    mg/l of nitrate concentration in the district. Nitrate concentration ranges from nil to a maximum value of 770 mg/l. Nitrate concentration within permissible limit i.e. 100mg/l is constituted by 69.14% of stations whereas 30.86% of stations represent more than 100 mg/l of nitrate concentration in the district. The high sodium absorption ratio (SAR) poses problem for irrigation water but sandy, highly porous and permeability nature of soil permit the use of ground water for irrigation. Ground water in Jhunjhunu urban area belongs to C3S3 and C3S4 class indicating the ground waters low suitability for irrigation purposes. The Jhunjhunu urban faces very high fluoride hazards having fluoride concentration reaching maximum to 15.3 mg/ l which is sustaintiated by the fact that 66.67% of stations constitutes fluoride concentration above permissible limit of 1.5 mg/l.[4] Apart from this, most part of the Alsisar block and western corner of Chirawa block have fluoride content more than 1.5 mg/l.

    Block

    Area (m2)

    Type

    Annual GW Available(mcm)

    Ground water

    draft for all uses(mcm)

    Chirawa

    493.04

    NC

    04.2657 A

    11.3842

    NC

    17.8892 A0

    58.3545

    Total

    22.1549

    69.7387

    5-Need- Long term water level data (pre-monsoon, 1997-2006) have indicated declining water level trend ranging from 0.0222 to 0.2010m/year. This area is under over-exploited category which is needed to be controlled through notifying the blocks and further imposing ban on construction of ground water abstraction structures except under indispensable cases. Three blocks i.e. Chirawa, Buhana, Surajgarh have been notified by Central Ground Water Authority, New Delhi. Due to pollution of both groundwater and surface waters, and the overall increased demand for water resources due to population growth, many communities all over the world are approaching the limits of their traditional water resources. Therefore they have to turn to alternative or new resources like rainwater harvesting (RWH). Rainwater harveting has regained importance as a valuable alternative

    or supplementary water resource

    Fig.2- Catchment Area layout of the study

    -5

    5.48×10

    -2

    to 1.05×10 .

  4. Ground Water Quality The ground water is alkaline type having pH value more than 7 and is potable in major part of the district except in northern part Alsisar block, northern most portion of Chirawa block, south east of Chirawa and in south eastern border (located at midst) of Khetri block. Nitrate concentration ranges from nil to a maximum value of 770 mg/l. Nitrate concentration within permissible limit i.e. 100mg/l is constituted by 69.14% of stations whereas 30.86% of stations represent more than 100

  1. Techniques may be adopted- In alluvial area, following ways of recharge techniques may be adopted. There are two main techniques of rain water harvestings.[8]

    a-Storage of rainwater on surface for future use.

    Recharge to ground water.

    b-The storage of rain water on surface is a traditional

    YEAR

    JAN

    FEB

    MAR

    APR

    MAY

    JUN

    JUL

    AUG

    SEP

    OCT

    NOV

    DEC

    TOTAL

    2001

    8

    0

    0

    3

    43

    151

    157

    100

    13

    0

    0

    0

    475

    2002

    0

    21

    0

    19

    37

    30

    0

    34

    9

    0

    0

    15

    165

    2003

    14

    7

    6

    0

    11

    27

    275

    190

    16

    0

    0

    7

    553

    2004

    0

    0

    0

    13

    33

    32

    2

    263

    0

    21

    0

    0

    364

    2005

    9

    56

    68

    0

    57

    58

    0

    0

    138

    0

    0

    0

    386

    2006

    0

    0

    56

    5

    43

    86

    243

    10

    77

    25

    0

    2

    547

    2007

    0

    74

    37

    20

    43

    68

    62

    26

    150

    0

    0

    0

    480

    2008

    0

    0

    0

    31

    78

    114

    87

    233

    138

    0

    0

    0

    681

    2009

    0

    1

    15

    0

    25

    41

    109

    33

    50

    0

    0

    0

    274

    2010

    4

    10

    4

    0

    0

    21

    84

    203

    186

    10

    20

    24

    566

    2011

    0

    42

    0

    0

    45

    48

    45

    182

    183

    0

    0

    0

    545

    AVG

    3.18

    19.18

    16.9

    8.27

    37.72

    61.45

    96.72

    115.81

    87.27

    5.09

    1.82

    4.36

    457.77

    Table4- Rainfall data of Chirawa Region (2001- 2011) in mm(Indian Metrological department)

    techniques and structures used were

    underground tanks, ponds, check dams, weirs etc.

    1. Roof top/paved area rain water harvesting for recharge to ground water in urban and industrial area.

    2. Village water runoff/roof top water harvesting by dug wells/percolation tanks in rural area.

    1. Site and Data Collection-

      The effective roof area and the material used in constructing the roof largely influence the efficiency of collection and the water quality. Artificial recharge to ground water is a process by which the ground water reservoir is augmented at a rate exceeding that obtaining under natural conditions or replenishment. Any man-made scheme or facility that adds water to an aquifer may be considered to be an artificial recharge system. Based on the above factors, the water harvesting potential of site could be estimated using the following equation:

      Rain Water harvesting potential = Amount of Rainfall x area of catchment x Runoff coefficient

      Fig.3- rain water endowment

    2. The calculation for runoff is as follows- Because of these factors the quantity of rain water which can effectively be harvested is always less than the rain

water endowment. The collection efficiency is mainly dependent on factors like runoff coefficient and first flush wastage etc. The total amount of water

which is received in the form of rainfall over an area is called the rainwater endowment of that area. Out of this, the amount that can be effectively wasted is

called the rainwater harvesting potential. Based on the calculation of floor, area of the building of department of Mechanical Engineering at Shridhar University, Pilani and rainfall pattern obtained from Indian Metrological department with-

Length of flat terrace (L)= 65.22 m Width of flat terrace (W)= 21.5 m

So, Total area (A) =L*W= 1402.23 m2

From table no. 1-

The average annual rainfall (R) on the site= 457.77 mm = 0.45777 m

The runoff coefficient (C) for a flat terrace may be considered as 0.85.

So, Annual water harvesting potential from 1402.23 m2 roof = A x R x C

= 1402.23 x 0.45777 x 0.85

=545.6140 cum

=545.6140x 1000

=5,45,614.003 litres

Diameter of pipe (mm)

Average rate of rain fall

(mm/hr)

50

75

100

100

13.4

8.9

6.6

Table 5- Arrangement of Pipe 8-System Requirement-

The rain water harvesting system consists of following basic components

  1. Catchment area

  2. Coarse mesh / leaf screen

  3. Gutter

  4. Down spout or conduit

  5. First flushing device

  6. Filter

  7. Storage tank

  8. Recharge structure

Catchment area is the surface on which the rain Water falls. In this study this is the floor of ME Department. This water can also be used for recharging ground aquifers after proper

filtration.

Coarse mesh / leaf screen is sed to prevent the entry of leaves and other debris in the system.

Gutters are provided to collect and divert the

Fig.4- Filteration Tank

rain water to downspout or conduits. Gutters can be of semi-circular, rectangular or trapezoidal shape.

Gutters must be properly sized, sloped and installed in order to maximize the quantity of harvested rain. Conduits can be of any material like PVC, GI or cast iron.

Filteration Tank is used to remove suspended pollutants from rain water collected over roof. The filter unit is basically a chamber filled with filtering media such as fiber, coarse sand and gravel layers to remove debris and dirt from water.

Concrete tanks are either poured in place or prefabricated . They can be constructed above ground or below ground.

Membrane Filtration-

Membrane filtration, such as reverse osmosis and nanofiltration work by forcing water under high pressure through a semipermeable membrane to

filter dissolved solids and salts, both of which are in very low concentrations in rainwater.

settlement tank The capacity of recharge tank is designed to retain runoff from at least 15 minutes of rainfall of peak intensity.

capacity of settlement tank = A x r x C

=1402.23×0.028×0.85

=33373 litres

For storing larger quantities of water the system will usually require a tank above or below the ground. Tanks can vary in size from a cubic metre (1,000 litres) up to hundreds of cubic metres for large reservoirs.

The rainwater storage tank collects all the filtered rainwater and keeps it for future use. The storage tank is made above the ground and on a platform. It can also be an underground sump in some cases. The capacity of the storage tank is based upon several design criteria: rainfall patterns and volume, the duration of the dry period and, of

course, the estimate of demand. Sometimes sophisticated calculations are involved, but these tend not to take into account human behavior and the

Fig.5-Proposed view of RHW Plan

willingness to use water if it is available and not to conserve it for future use, in the hope that the dry spell will soon be over.

OVERFLOW PIPE: The storage tank will have an overflow pipe from the top of the tank. In case of heavy rain, the overflow pipe will allow the excess rain water to be safely disposed of without causing any flooding.

  1. WATER QUALITY CHECK: If the roof, the gutter, the first rain separator and the filter is kept clean, the collected rainwater will be crystal clear. This is an indication that good maintenance is being followed. Most storage tanks are equipped with manholes to allow access for cleaning. Sediment and sludge can be pumped out or siphoned out using hose with an inverted funnel at one end without draining the tank annually. Rainwater harvesting is one of the most promising alternatives for supplying water in the face of increasing water scarcity and escalating demand. The use of slow sand filtration has proved to be a simple and effective treatment technology for the elimination of most of the organic and inorganic pollutants that may be present in rainwater, as well as

    Fig6.- storage Container

    producing a virtually pathogen-free water for drinking.

    1. Inspection- As a raindrop falls and comes in contact with the atmosphere, it dissolves naturally occurring carbon dioxide to form a weak acid. The resultant pH is about 5.7, whereas a pH of 7.0 is neutral. So it should be Periodic duty to include: a- monitoring tank levels, cleaning gutters and first- flush devices, repairing leaks, repairing and maintaining the system, and adopting efficient water use practices. The cleanliness of the roof in a rainwater harvesting system most directly affects the quality of the captured water. The cleaner the roof, the less strain is placed on the treatment equipment. Rainwater can be also treated for use as a potable water source.

    2. Result & Advantages from the study- We can see that, we can obtain 5,45, 614.003 Liters of water annually. Rain water harvested from catchment surfaces along the ground should be used for lawn watering, flushing, Horticulture and ground water recharge etc. Rainwater is valued for its purity and softness. It has a nearly neutral pH, and is free from disinfection by-products, salts, minerals, and other natural and man-made contaminants. Plants thrive under irrigation with stored rainwater. An advantage

      Fig.- Water supply from RHW Supply Tank

      for household systems is that users themselves maintain and control their systems without the need to rely on other members of the community. Since almost all roofing material is acceptable for collecting water for household purposes, worldwide many RWH systems have been implemented successfully. Demand for water is growing in most cities as every urban citizen requires almost double the amount of water that a rural citizen requires. Moreover, India is rapidly urbanizing. Urban population in India has grown almost five times in five decades from 1951 (62.44 million) to 2001 (286.08). Not long ago, most of our cities were self sufficient in meeting their water needs from the extensive urban water bodies to supply water to citizens. Today these water bodies have completely disappeared. Rainwater harvesting is practical only when the volume and frequency of rainfall and size

      of the catchment surface can generate sufficient water for the intended purpose. Rainwater harvesting in urban and rural areas offers several benefits including provision of supplemental water, increasing soil moisture levels for urban greenery, increasing the groundwater table via artificial recharge, mitigating urban flooding and improving the quality of groundwater. In homes and buildings, collected rainwater can be used for irrigation, toilet flushing and laundry.

      Rainwater is a relatively clean and free source of water. Rainwater harvesting provides a source of water at the point where it is needed. It is owner- operated and managed. It is socially acceptable and environmentally responsible. It promotes self- sufficiency and conserves water resources .Rainwater is friendly to landscape plants and gardens It reduces storm water runoff and non-point source pollution .It uses simple, flexible technologies that are easy to maintain. Offers potential cost savings especially with rising water costs.

    3. Reference-

  1. Pacey, Arnold and Cullis, Adrian, (1989), Rainwater Harvesting: The collection of rainfall and runoff in rural areas, Intermediate Technology Publications, London

  2. www.wikipedis.org/chirawa

  3. Imminent Water Crisis in India, UNICEF Report,August, (2007).

  4. Report of Central Ground Water Board, Region Jaipur, New Delhi, India Nov-2008

  5. Indian Standard Guidelines for Rain Water Harvesting in hilly areas by roof water collection system IS 14961:2001

  6. Sazakli E, Alexopoulos A, Leotsinidis M (2007) Rainwater harvesting quality assessment and utilization in Kefalonia Island, Greece.

  7. http://www.rainwaterharvesting.org

  8. World-wide Distribution of Water, A Water Harvesting Manual for urban areas issued by Centre

    For Science and Environment

  9. Remuneration of RAin Water harvwsting in KNIT campus by Abhishek Agarwal, Anoop Kumar, ISST Journal of Mechanical Engineering, Vol. 3 No.1, (January – June 2012), p.p. 41-45

  10. Energy and water conservation: Present need –

D.N. Srivastava, IJME,February, 2010

Author 1,2,3- are B.Tech. in Mechanical Engineering.

Author4- He is B.Tech. Hons. In Mechanical Engineering & M.Tech.in Thermal Engineering. He is Asst. Prof, in Dept. of ME. His various Research papers has been published in reputed journals in area of Environmental issues, Solar/PV Technology etc.

Leave a Reply