- Open Access
- Total Downloads : 5
- Authors : Safiya Daliya Ahammed, Shahla C. P
- Paper ID : IJERTV8IS020097
- Volume & Issue : Volume 08, Issue 02 (February – 2019)
- Published (First Online): 07-03-2019
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Seismic Behaviour of Hexagrid Type Structural System
Safiya Daliya Ahammed Shahla C. P
M Tech Scholar Assistant Professor
AWH Engineering College,
Kozhikkode
AWH Engineering College, Kozhikkode
Abstract
– There are a number of high-rise structures constructed all over the world and are being continue to construct. The analysis and design of high-rise structures is quite different from that of low rise structures because of lateral forces due to wind and earthquake. In high-rise structures the resistance to lateral loading becomes dominant criteria that have to be considered in the analysis and design and an efficient lateral load resisting system will define the efficiency of tall structures. In order to improve the efficiency of tube-type structures in tall buildings, a new structural system, called "Hexagrid", is introduced in this study. It consists of multiple hexagonal grids on the facade of the building. In hexagrid structural system almost all the conventional columns are eliminated. The hexagrid resist both gravity & lateral load by the axial action of the diagonal members so, they simply act in tension or compression with no bending, depending upon the direction of the loading. A regular floor plan 36m x 36m and irregular floor plans shaped in the form of C, L and T are considered, all structural members are designed as per IS 456:2000. G+30, G+40 and G+50 storeys models are considered to compare the performance in accordance with height. Earthquake parameters are considered from 1893-2002. Dead & live loads are considered as per Indian Standards. Here, analysis of hexagrid system will be conducted by using analysis & design software, ETABS.
-
INTRODUCTION
Tall buildings have great potential of creating sustain- able built environments by their own nature. Compared with the cities with low-rise buildings, those with tall buildings use land more efficiently. Early designs of tall buildings recognized the effectiveness of diagonal bracing members in resisting lateral forces. Most of the structural systems deployed for early tall buildings were steel frames with diagonal bracings of various configurations such as X, K, and chevron.
A major point of this design approach is to introduce a new structural system for Tall building. The hexagonal and diamonds were located along the entire exterior perimeter surfaces of the building in order to maximize their structural effectiveness and capitalize on the aesthetic innovation. This strategy is much more effective than confining diagonals to narrower building cores. In the hexagrid structure system, almost all the conventional vertical columns are eliminated. Our approach is to define a unique structural system for Tall building in order to minimize additional system for lateral loads (lateral system). In this system (Beehive), members in hexagrid structural systems can carry gravity loads as well
as lateral forces due to their hexagonized configuration in a distributive and uniform manner. Compared with other systems in Tall buildings, hexagrid structures are much more effective in minimizing shear deformation because they carry shear by axial action of the diagonal members, while other structures carry shear by the bending of the vertical columns and horizontal spandrels.
Fig 1. Example of hexagrid structure
-
METHODOLOGY
-
Conduct literature review on seismic behaviour of hexagrid structures.
-
Modelling of G+30, G+40 and G+50 RC structures with plan irregularities.
-
Analysis to be done using ETABS software.
-
Time period, top storey displacement, storey drift and base shear parameters are compared.
-
-
MODELLING OF BUILDINGS
An ideal symmetric structures having the distribution of loads is uniform along each storey and three asymmetric structures were chosen for the study. Asymmetric structures includes C shape, L shape and T shape floor. The buildings under consideration are high rise buildings. All the structure had got the same perimeter for the plot they are compared for their irregular plan. The seismic analysis were carried out as per the code IS 1893: 2002. Zone V and medium soil type are considered for analysis. The analysis of the structural model is done in ETABS 2016.
G+30, G+40 and G+50 storied RC structures which are symmetric and asymmetric in plan have been considered for the study. The RC design is based on IS-456 (2000). The building is assumed to be situated in Zone V as per IS 1893 (2000). The concrete floors are modelled as rigid. The details of the model is given in the table 1. The structures are assumed to be constructed on medium soil as per IS 1893.
Table 1: Structural details
Plan Dimensions
36m x 36m
Floor to floor height
3m
Depth of slab
120mm
Number of stories
G+30, G+40 and G+50
Floor finish
1kN/m2
Live load
2kN/m2
Characteristics strength of concrete
30N/mm2
Characteristics strength of steel
415 N/mm2
B1
400mm x 600mm
C1
1650mm x 1650mm
D1
800mm x 800mm
Angle of inclination
45°
Zone factor
0.36
Importance factor
1
Type of soil
Medium
Response reduction factor
5
Damping ratio
5%
-
Variation of height
It contains structures with variation in height. ie, G+30, G+40 and G+50 structures. Fig 2 shows the typical elevations for these structures.
G+30 G+40 G+50
Fig 2. Elevation of building
-
Variation in plan shape
It contains G+30, G+40 and G+50 structures with variation in plan shapes. Different plan shapes are C shape, L shape and T shape. Fig 3 shows the different plan irregularities used for the thesis work.
Regular shape C shape
L shape T shape
Fig 3. Plan irregularity
-
Model Geometry
-
In order to differentiate models from each other various abbreviations are used. For example, C30: Model with 30 storey C shaped plan irregularity. Table 3 given below shows the model details of the thesis work. Fig 4 to 6 shows the three dimensional view of models used for the study.
Table 2: Model details
Designation
Details
R30
30 storey regular structure
C30
30 storey C shaped plan irregular structure
L30
30 storey L shaped plan irregular structure
T30
30 storey T shaped plan irregular structure
R40
40 storey regular structure
C40
40 storey C shaped plan irregular structure
L40
40 storey L shaped plan irregular structure
T40
40 storey T shaped plan irregular structure
R50
50 storey regular structure
C50
50 storey C shaped plan irregular structure
L50
50 storey L shaped plan irregular structure
T50
50 storey T shaped plan irregular structure
(a) R30 (b) C30
(c) L30 (d) T30
Fig 4. Three dimensional view of 30 storey building
(a) R40 (b) C40
(c) L40 (d) T40
Fig 5. Three dimensional view of 40 storey building
(a) R50 (b) C50
(c) L50 (d) T50
Fig 6. Three dimensional view of 50 storey building
-
-
ANALYSIS
In the present study, static and dynamic analysis of the models created are carried out using modeling and analysis software ETABS. Hexagrid structural system consists of Hexagrid perimeter which is made up of a network of multi- story tall hex-angulated truss system. Hexagrid is formed by intersecting the diagonal and horizontal components. This innovation transfers both gravity loads and lateral loads by redirecting member forces, and eliminates the need for vertical columns on the exterior of the building. Architecturally the absence of columns in the corners of the building provides great panoramic views from the interior. Structurally, the degree of an angle between diagonal members consisting of Hexagird nodes is a significant design variable to determine stress distribution resisting internal forces into Hexagrid as well as a building system. In addition, the stress distribution changes depending on the height and span of a given building and the member size like thickness of Diagrid.
Most of all, connectivity among the hexagrid members linked to member angles is the first considerable element for hexagrid analysis, since investigation of connectivity, i.e., topology provides us with global systematical mechanism. In order to measure hexagrid member analysis and compare the results, in the comparison presented here, diverse pined supports for boundary condition are deposited into a given initial design space. Pined support positions are modeled by initial domain distributions of density which is referred to as design variables. The column-shape, and beam-shape, which depend on initial topologies into design space, i.e., angles of Pined supports. Positions where relatively large stress acts are structurally weak, and therefore material supplement needs to be properly stiffened there. The optimal density assignments are equal to stress distributions.
Stress at the centre node position which is produced by a horizontal load is larger than that by a vertical load. It means that material reinforcement for resisting a horizontal load is more necessary than one for a vertical load. The largest stress acts to the node part in all the angle models, and therefore a node part or a connection of diagonal members is the most significant reinforcement component with respect to structural safety in Hexagrid systems. The Hexagrids are redundant and load path following. It combines the benefits of a hollow tube with those of a truss and its chords. The angled setting of the columnar elements allows for a natural flow of forces through the structure. In this manner, both gravity loads and lateral loads are transferred through the Hexagrid to the ground below. Loads are able to follow the hexagons through the structure as it naturally resists vectors of forces through its hexagonal shapes. Load paths are continuous and uninterrupted. Vertical gravity loads follow the structure of the tube from top to base along the hexagonal members of said tube. The same vertical gravity loads are able to transfer from one columnar element to another in the rare or designed case of an interruption.
-
RESULTS AND DISCUSSIONS
Analysis of a structure provides a comprehensive idea about the overall response history of structure. Here we have done the linear static and dynamic analysis. Maximum story displacement, story shear, drift and time period for modes are obtained. Tables 3, 4 and 5 shows the analysis results of G+30, G+40 and G+50 storey models with plan irregularities.
Displacement comparison of G+30, G+40 and G+50 are shown in Fig 7, 9 and 11. Time Period comparison is shown in Fig 8, 10 and 12.
Table 3: Analysis results of G+30 models
Fig 7. Displacement comparison of G+30
Fig 8. Time Period comparison of G+30
Table 4: Analysis results of G+40 models
Model
Displacement (mm)
Time-period (sec)
Drift (%)
Base Shear (kN)
R40
90.7
3.356
0.06
7965
C40
75.8
3.401
0.06
9001
L40
86.5
3.424
0.1
5076
T40
98.4
3.34
0.08
5265
Fig 9. Displacement comparison of G+40
Model
Displacement (mm)
Time-period (sec)
Drift (%)
Base Shear (kN)
R30
59.33
2.289
0.04
8812
C30
47.6
2.333
0.04
10357
L30
58.46
2.237
0.08
5867
T30
64.13
2.209
0.06
5995
Fig 10. Time Period comparison of G+40
Table 4: Analysis results of G+50 models
Model
Displacement (mm)
Time-period (sec)
Drift (%)
Base Shear (kN)
R40
149
4.63
0.08
8333
C40
111.1
4.635
0.08
7878
L40
161.7
4.93
0.16
5839
T40
163.7
4.69
0.1
5490
Fig 11. Displacement comparison of G+50
Fig 12. Time Period comparison of G+50
-
CONCLUSIONS
In the above structural models the linear static and dynamic analysis is performed to investigate the performance point of the building frame in terms of displacement, Time period, Drift ration and Base shear. From the above study following conclusions were drawn.
-
Based on plan irregularity, minimum displacement is in the order C < L < Symmetric < T (X-direction) in G+30, G+40 and G+50.
-
As the height of building increases displacement also increases (maximum in G+50 model).
-
The performance point of T shape and L shape plan irregularity is almost nearer to each other. It maybe due to same plan area.
-
Time period increases with increase in height of the building.
-
Base shear is minimum for G+40 models except for C shaped model.
REFERENCES
-
Ronak S. Vagadiya, et al., (2017) A Study on Seismic Behavior of Hexagrid Type Structural System, IJARIIE-ISSN(O)-2395-4396 Vol-3 Issue-2 2017
-
Han-Ul Lee et al., (2017) Preliminary design of tall building structures with a hexagrid system, doi: 10.1016/j.proeng.2017.01.461.
-
Taranath S. D. et al., (2014) Comparative Study of Pentagrid and Hexagrid Structural System for Tall Building, ISSN: 2349-879X;
Volume 1, Number 2; August, 2014
-
Diya Susan Ebin et al., (2016) Study On Structural Behaviour of Hexagrid Structural Systems In Multi Storey Buildings, Int. J.
Chem. Sci.: 14(S1), 2016
-
Mohsen Rostami et al., (2016) Evaluation of new Hexagrid structural system in bionic high-rise buildings, 5th International conference on research in science and technology, London