Seismic Comparison of Building with or without Deep Beam

DOI : 10.17577/IJERTV5IS070440

Download Full-Text PDF Cite this Publication

Text Only Version

Seismic Comparison of Building with or without Deep Beam

Sagar Belgaonkar Assistant professor

Department of Civil Engineering

S.G.B.I.T Belagavi Karnataka, India

Abstract Tall structure developments are increasing rapidly now a days throughout the world. Due to earthquake which happens rarely around the world, so the structure have to made earthquake resisting structure.

The present study reviews that seismic analysis of reinforced concrete building with and without deep beam. The proposed building consists of 10 stories bottom storey height is 3.5m and the remaining storey height is 3.2m and building is 24m length, 24m width and 32.3m above from the ground level. It is considered under the seismic zone 5. The structure analysis of proposed building is carried out by E-tabs 2013 software. The proposed building model has been done. Models are analyzed by equivalent static method and dynamic method to resist the lateral load.

From the study on the behavior of the models with and without deep beams it is seen that deep beam has a significant impact on the entire structure and hence deep beams can be one of the solutions for resisting effect of earthquake on the structure.

Keywords Deep beam, Equivalent static analysis, Dynamic analysis, Base reaction, Time period, Storey Stiffness

  1. INTRODUCTION

    Earthquake (otherwise called a shudder, tremor or temblor) is the detectable shaking of the surface of the Earth, coming about because of the sudden arrival of vitality in the Earth's outside that makes seismic waves. This tremor can be the reason for the failure of soil, rupture of surfaces, damages to the structures and human deaths. At the Earth's surface, tremor show itself by shaking and once in a while uprooting of the ground. This is the point when the epicenter of a substantial seismic tremor is found offshore, the seabed might be displaced adequately to create Tsunami. The word tremor is utilized to portray any seismic occasion whether characteristic or created by humans that produces seismic waves. Tremors are brought about generally by crack of topographical faults, additionally by for example, volcanic action, avalanches, mine impacts, and atomic tests. A quake's purpose of introductory burst is called its center or hypocenter. The epicenter is the point at earth surface straightforwardly over the hypocenter.

    Rajashekhar Bilagi

    P.G Student Department of Civil Engineering

    S.G.B.I.T Belagavi Karnataka, India

    A. Deep beam concept

    Deep beams are basic structural components loaded as beams in which a significant measure of the load is exchanged to the supports by compression push joining the load and the reaction. As result, the strain distribution in no longer considered linear and the shear disfigurements get to be critical when thought about unadulterated flexure

    A few specialists have chosen that the shear span effective depth proportion l/d is more significant to characterize deep beam, and that a. beam could be viewed as deep if shear span to depth proportion (l/d) <2 for simply supported deep beam and l/d ratio is less than 2.5 for continuous deep beam.

    Especially, the utilization of deep beams at the lower levels in tall structures for both private and business purposes has expanded quickly as a result of their accommodation and sparing productivity. R.C deep beams have numerous helpful applications in structures, for example, transfer girders, wall footings, foundation pile tops, floor diaphragm and shear dividers. Beams such sort frequently emerge in the development of containers or comparative structures, and additionally pile tops and transfer girders.

  2. METHODOLOGY

    1. problem definition

      A 10 storey building with 3m and 3.2m deep beam and 10 storey conventional building of symmetric plan dimension of 24mx24m bay spacing 6m along each direction and bottom storey height is 3.5m and remaining storey height is 3.2m is considered

      1. Size of bay : 6m x 6m

      2. Size of column : 600mm x 600mm

      3. Size of beam : 300mm x 400mm

      4. Deep beam size :300mm x 3000mm

      5. Deep beam size :300mm x 3200mm

      6. Column size bottom storey : 950mm x 950m

        Table 1: physical properties of concrete and steel

        Properties of concrete

        Grade of concrete

        M30

        Modulus elasticity

        27386.12MPa

        Poisson's ratio

        0.2

        Properties of reinforcement steel and masonry

        Grade of steel

        Fe 415

        Modulus elasticity

        210000 MPa

        Density of concrete

        25kN/m3

        Poisson's ratio

        0.3

        Density of brick wall including plaster

        20kN/m3

        Table 2: seismic parameters

        Seismic parameters (IS 1893-2002)

        Zone

        V

        Soil type

        1(HARD SOIL)

        Impact factor

        1

    2. Modeling of the structure

    Generally this study consists of 3 different type of models which is listed below in Table 3 and building with 3m deep beam at ground storey that is named as model 1 similarly model

    2 which consists of 3.2m deep beam at ground storey the structure analysis of proposed building is carried out by E-tabs 2013 software. The proposed building model has been done. Models are analyzed by equivalent static method and dynamic method to resist the lateral load.

    Table 3: details of typical models

    Serial number

    Description of models

    1

    Bare Frame Model

    2

    Bare Frame Model With 3m Deep at

    Ground Storey

    3

    Bare Frame Model With 3.2m Deep

    Beam at Ground Storey

    Fig 1. Plan view of conventional building

    Fig 2. Elevation for Conventional Building

    Fig 3: Plan View of Bare Frame Building with 3m Deep Beam at

    Ground Storey

    Fig 4: Elevation for Bare Frame Building with 3m Deep Beam at

    Ground Storey

    Fig 5. Plan view for bare frame building with 3.2m deep beam at Ground Storey

    Fig 6. Elevation for Building with 3.2m Deep Beam at Ground Storey

  3. RESULT AND DISCUSSION

In this chapter results are shown in form of tables and figures for different type of building models and parameters such as storey stiffness, natural period, and base reactions are considered. Results for comparison between bare frame conventional building and building with deep beam are below.

  1. Base reaction

    Table 4: Maximum Base reaction for bare frame building

    Base Reaction(kN)

    Model 1

    Model 2

    Conventional

    1563.45

    1570.94

    1487.13

    Graph 1: maximum base reaction

    Table 4 and Graph .1 it is seen that base reaction of building with deep beam is more compared to the conventional building. The average increase in base reaction for deep beam building is about 5.35%and 0.46%. It is also observed that the base reaction is increases significantly i building with deep beam as compared with conventional building, since mass of the structure with deep beam is more compared to conventional building.

  2. Natural period

    Table 5: Natural period for bare frame building

    Natural

    period in (sec)

    Model 1

    Model 2

    Conventional

    2.088

    2.087

    2.132

    Graph 2: maximum. Natural period

    From the analysis and from Table 5 Graph 2 it is observed that the natural period obtained has a very slight difference for both type of analysis methods this is due to same structural configurations. Graph 4.4 indicates that there is increase in natural period in conventional building as compared to building with deep beam. The percentage of increase in natural period is 2.06% and 2.11%.The natural period decreases in building with deep beam compared with conventional building because as stiffness increases natural period decreases.

  3. Stiffness

    Table 6: maximum storey stiffness

    Stiffness in (kN/m)

    Storey

    Model 1

    Model 2

    Conventional

    Storey10

    112765.8

    112807

    117493.206

    Storey9

    176940

    176970.8

    176964.176

    Stoery8

    179813.4

    179826.6

    180285.415

    Storey7

    177173.9

    177190.1

    177573.601

    Storey6

    175119.9

    175134.4

    174643.818

    Storey5

    177823.5

    177845.2

    177333.377

    Storey4

    192802.3

    192855.1

    188862.722

    Storey3

    236341.8

    236470.3

    226144.838

    Storey2

    465277.2

    466330.6

    390784.044

    Storey1

    3683292

    3734948

    1883875.283

    Base

    0

    0

    0

    Graph 3.Maximum storey stiffness

    From Table 6 and Graph 3 it is seen that storey stiffness is more for building with deep beam as compared to conventional building, there is twice increase in the value of the stiffness at ground storey due to deep beam provided at ground storey.

    V.CONCLUSION

    The seismic behavior of deep beam is studied considering the deep beam at ground storey of the structure by using equivalent static method and response spectrum method. Based on analytic analysis result has been made.

    1. It is been observed that base reaction increases in building with deep beam as compared to conventional building

    2. Considering the effect of deep beam in building, the stiffness of the structure increases rapidly for ground storey up to 49.56% and it considerably changes in higher stories.

    3. Natural period is significantly lowered after introducing deep beam in building at ground storey.

ACKNOWLEDGMENT

I hereby acknowledge my deep sense of gratitude and indebtedness to my guide Prof. Sagar Belgaonkar, Civil Engineering department for suggesting this project title and for his invaluable guidance, inspiration and keen interest throughout my thesis work. He was the guiding beacon of light during the dissertation work

I also obliged to my beloved Parents for their unstinted support, encouragement and patience leading me to the successful completion of the project.

I also thank all my friends and seniors who have helped me directly or indirectly during the course of this project. Above all I would like to thank the Almighty for everything to complete this Project work.

REFERENCES

[1]. Yogendra singh, "Lateral Load Resisting System for Multistoried Buildings", Department of Earthquake Engineering, IIT Roorkee, India, April-2014, Page No 1-21.

[2]. Bashir Habeeb Alla Osman, "Shear in R.C Deep Beam", Faculty of Engineering, University of Khartoum, Civil Engineering Department. April-2008, Page No 1-93.

[3]. Abhijit Baikerikar and Kanchana Kanagali, "Study of Lateral Load Resisting System of Variable Heights in All Soil Types of High Seismic Zone", International Journal of Research Engineering and Technology.eISSN:2319-1163, pISSN; 2321-7308, Volm; 03Issue; 10 october-2014, Page No109-119

[4]. Dr. Panduranga .s. Patil, Experimental Study On R.C.C Deep

Beam "International Journal Of Emerging Technology and Advance Engineering, ISSN 2250-2459,ISO 9001;2008,volm 4,issue 7.july2014 , Page No 801-805.

[5]. Ma nay yee kyan, and aye mya cho, "Comparison On Force Of Reinforced Concrete Building Without And With Deep Beam, ISSN 2319- 885,volm.03,issue.09,may 2014,Page No 1688-1693.

[6]. Mohammad reza salamy Et al, "Experiment And Analytical Study On R.C Deep Beam Behavior Under Monotonic Load", Senior Research Engineer, Earthquake Engineering Research Team, Public Works Research Institution ,1-6 Minamihar, Tsukuba-shi, Ibaraki-ken 305-8516, Japan, Page No1-47.

[7]. Firoz alam Faroque, and Rishikesh kumar, "Comparison Of Design Of Calculation Of Deep Beam Using Various International Codes", International Journal Of Civil Engineering (SSRG-IJCE)-volume 2 Issue 10 .October- 2015, Page No 18-26.

[8]. J.Leon Raj, and G.Appa rao, "shear strength of R.C deep beam panels", International journal of research engineering and technology, eissn; 2319- 463, pissn; 2321-7308, Page No 89-103.

Books and IS codes

[1]. M.Y.H. Bangash, "Earthquake Resistant Building", Consultant Engineer in Advanced Structural Analysis, London, UK. ISBN 978-3-540-93817-0, eISBN 978-3-540- 93818-7, DOI 10.1007/978-3-540-93818-7, Published By;

Springer- Verlag Berlin Heidelberg 2011, Page No 1 4. [2]. Dr.N.Krishna raju, "Advanced Reinforced Concrete Design

(IS: 456-2000)", Indian Binding House, Noida, Second Edition 2005.

[3]. IS 875; 1987 "Code Practice for Design Loads (Other Than Earthquake) For Building and Structure, Part-2 Imposed Loads, Bureau of Indian Standard, New Delhi, India.

[4]. IS 875; 1987 "Code Practice for Design Loads (Other than Earthquake) For Building and Structure, Part-1 Dead Loads", Bureau of Indian Standard, New Delhi, India.

[5]. IS 456:2000, "Code of Practice for Plain and Reinforced Concrete", Bureau of Indian standards, New Delhi, India

[6]. IS 1893:2002,"Indian Standard Criteria For Earthquake Resistance Design Of Structure Part- 1 General Provisions And Building", Bureau Of Indian Standards, New Delhi, India.

[7]. IS 875; 1987 "Code Practice for Design Loads (Other Than Earthquake) For Building and Structure, Part-5 Special Loads and Combinations, Bureau of Indian Standard, New Delhi, India.

Leave a Reply