Theoretical Assessment of PV Energy Potential At Assam Engineering College using PV Indices

DOI : 10.17577/IJERTV3IS081033

Download Full-Text PDF Cite this Publication

Text Only Version

Theoretical Assessment of PV Energy Potential At Assam Engineering College using PV Indices

1*Barnam Jyoti Saharia, 2Bani KantaTalukdar

1,2Department of Electrical and Instrumentation Engineering, Assam Engineering College, Guwahati, Assam, India-781013

Abstract: This paper makes a photovoltaic (PV) energy potential assessment of a technological institution, namely Assam Engineering College (AEC) in Assam, India (26.13 °N, 91.66 °E) using PV indices. A 5kWp PV system is designed in MATLAB/SIMULINK simulation platform and PV indices are implemented to evaluate the feasibility and future applicability of the location as a possible site for renewable energy generation using PV technology. Results reflect that the possible yield of renewable power from the site lie within the range of average values of minimum of 1.82 kWh/kWp/day and a maximum of 2.651 kWh/kWp/day with an average value of 2.238 kWh/kWp/day for the year, thus indicating that the site can in fact be used successfully to harness solar energy.

Keywords: Renewable energy, PV, PV indices, Matlab/simulink

  1. INTRODUCTION

    Power generation through photovoltaic (PV) generation system is one of the most sought after forms of renewable energy sources, popularityof which has been in the rise due to its non-polluting, renewable and inexhaustible nature [1]. Immense demand for finding feasible and environmental friendly renewable energy sources to meet the future energy requirements as fossil fuel reserves deplete. Solar energy is a viable substitute to fossil fuels among other available renewable energy sources such as wind, hydroelectric and geothermal power [2]. Solar PV generators

    in the summer season due to inadequate supply of power from the utility. This paper studies the feasibility of using PV

    systems as a possible viable solution to compensate part of the inadequate supply. The paper is organised as follows. The introduction in section I is followed by the methodology implemented for the analysis in section II. This section comprises of the three subsections that discuss the data used for the site, PV module modelling and the PV performance evaluation for analysis. Section III summarises the results and discussion and section IV concludes with the findings of the study.

  2. METHODOLOGY IMPLEMENTED

    1. DATA USED

      The Indian Meteorological department has nationwide network of stations that records solar radiation and sunshine duration on a daily basis. However, North east India is not covered in a full extent by the radiation stations. This paper takes into account indirect measured data [5] (22 year averaged data for the site has been considered) due to inadequate measured data. Also the accuracy of data source is in the range of 11-17% [6].

      Temperature (°C)

      have been used in small scale, stand-alone systems at low Insolation (kW/m2)

      voltage levels as well as the high power installations, connected in grid mode and operating at medium or high voltage levels [2].

      Government of India, in an effort to meet up with the challenge of growing demand of power, has started several special initiatives to disseminate renewable energy systems in North Eastern states of India[3]. India as a country due to its location near the equatorial Sunbelt enjoys sufficient solar radiation, with about 300 clear sunny days and at an average of 4-7 kWh/day. Assam Engineering College(AEC), the first engineering college in the north-east India, was established in the year 1955. It is situated at Jalukbari in the south-west part of Guwahati, which is a landmark in the colourful and chequered history of Assam [4]. The institution faces a serious deterrent in meeting the adequate power requirement

      6.0 24

      5.5 22

      Insolation (kW/m2)

      Temperature (°C)

      5.0 20

      4.5 18

      4.0 16

      3.5 14

      3.0 12

      2.5 10

      1 2 3 4 5 6 7 8 9 10 11 12

      Month of year

      Figure 1: The average monthly solar total in-plane insolation and mean ambient temperature variation over a year

      TABLE 1: Solar insolation, temperature, and daylight hours at Assam Engineering College for a year

      Month

      Jan

      Feb

      Mar

      April

      May

      June

      July

      Aug

      Sept

      Oct

      Nov

      Dec

      Solar Insolation (kW/m2)

      0.4

      0.44

      0.47

      0.45

      0.39

      0.324

      0.308

      0.333

      0.329

      0.400

      0.417

      0.398

      Temperature (°C)

      11.7

      14

      17.6

      19.5

      21

      22.4

      22.7

      22.7

      21.6

      19.2

      15.8

      12.8

      Hours (h)

      10.7

      11.3

      12.0

      12.7

      13.4

      13.7

      13.6

      13.0

      12.3

      11.5

      10.9

      10.5

      The average monthly solar total in-plane insolation and mean ambient temperature variation over a year is shown in figure 1. Table 1 depicts the compiled data sets used in the

      analysis, showing the monthly averaged global horizontal incident radiation in kW/m2, temperature at 10 m above mean

      Module reverse saturation current (Irs) is given by:

      Irs Iscr / [exp(qVoc / NsKAT ) 1]

      (2)

      sea level above the surface of the earth in (°C) and daylight hours.

      The module saturation current (Io) varies with the cell

      temperature, which is expressed as:

      Io Irs[T / Tr]3 e xp(qEgo / AK )[ 1 1 ]

    2. PV module modelling in software:

      Tr T

      (3)

      A solar cell is basically a p-n junction fabricated in a thin

      The current output of the PV module (Ipv) is represented by:

      wafer of semiconductor. The electromagnetic radiation of

      I

      q(Vpv IpvRs)

      solar energy can be directly converted into electricity through

      the PV effect. When exposed to sunlight, photon with energy greater than the band-gap of the semiconductor creates the

      pv NpIph NpIo[e xp{ }1]

      NsAKT

      (4)

      electron-hole pairs proportional to the incident radiation which is responsible for the generation of photocurrent.

      Figure 2 shows the equivalent circuit of a PV cell. The current source Iph represents the photocurrent. Rsh and Rs are the intrinsic shunt and series resistances of the cell respectively. Usually the value of Rsh is very large and hence they may be neglected to simplify the analysis.

      Each PV cell, when grouped together in a combination of parallel and series cells constitute a PV module and PV arrays. Equations (1) (4) are used for the modelling of the reference PV module KYOCERA KC120- 1[7].

      FIG.2. PV cell as a diode circuit

      Where Iscr is the PV module short-circuit current(A) at 1kW/m2 and 25ºC, Kiis the short-circuit current temperature co-efficient at Iscr (0.0017A/°C), T is the module operating temperature in Kelvin (K), is the PV module illumination (kW/m2), Irs is the reverse saturation current of the module (A), q is Electron charge (1.6 × 10-19 C ),Vocis the open circuit voltage of the PV panel (V), Ns is the number of cells connected in series in the PV module, k is Boltzmanns constant having the vlue of 1.3805 × 10-23 J/K , A is an ideality factor having value of 1.2, Io is the PV module saturation current (A), Tr is the reference temperature in Kelvin ( 298 K), Ego is the band gap for silicon having value of 1.1 eV, Ipvis output current of a PV module (A) , Vpv is the output voltage of the PV module (V), Np is the number of cells connected in parallel for the PV module. In the mathematical model the cells in series and the cells in parallel have values of Ns=36 and Np=1.

      Table II lists the electrical specifications of the Kyocera KC120-1 PV module [7] specified at standard testing conditions (i.e. at a irradiation of 1000 W/m2, 25° C temperature and AM 1.5)which has been considered as the reference module in this paper for investigation. Figures 2 depicts the current voltage (I-V) and power voltage(P-V) characteristics of the simulated PV module at STC indicating that the model is able to predict accurately the PV module characteristics. To develop a 5kWp PV system, the number of strings required to be connected in series and parallel were found to be 6 and 7 respectively based on the reference module current and voltage ratings.

      Module Photocurrent (Iph) is expressed by:

      Iph [Iscr Ki(T 298)] /1000

      (1)

      Table II. Electrical Characteristics of Kyocera KC120-1 PV model[7]

    3. PV performance evaluation:

    Parameter

    Rating

    Maximum Power

    120 W

    Voltage at maximum power

    16.9 V

    Current at maximum power

    7.10 A

    Short circuit current

    7.45 A

    Open circuit voltage

    21.5 V

    Total number of cells in series

    36

    Total no of cells in parallel

    1

    Band Energy

    1.12 eV

    Ideality factor

    1.2

    In order to ascertain the ideal solar performance for a PV plant, the battery and loads are excluded from the system under investigation. Assumption is made that the system consists of only the PV generator and the inverter. For simplification, the inverter efficiency is assumed to be 95% (to account for the losses in the switching, etc). The system block diagram is shown in figure 3. The monthly averaged data for solar insolation and temperature for a year are given as inputs to the PV model developed in Matlab/Simulink software. The PV energy is computed as the product of the PV output power and the average daylight hour. The available AC power at the output of the inverter is the product of the PV generator power and the converter efficiency. Evaluation of the PV generator performance, the PV system performance monitoring guidelines for measurement, data exchange and analysis (IEC standard 61724) [8] and the international energy agency task II database on photovoltaic power system [9] have been used.

    8

    Current

    7 Power

    6

    Current (A)

    5

    4

    3

    2

    1

    0

    0 2 4 6 8 10 12 14 16 18 20 22 24

    Voltage (V)

    140

    120

    Power (W)

    100

    80

    60

    40

    20

    0

    Figure 4: Block diagram of the simple PV generator system

  3. RESULTS AND DISCUSSION

    The PV system indices considered in this study are the array yield(Ya), final yield (Yf), reference yield(Yr), system losses (Ls) and the performance ratio (PR). These parameters are independent of the array size and are normalised by the array nominal installed power at STC, obtained from the data given in the manufacturers data sheet for the considered reference PV module. The array yield is defined as the daily array energy output (Edc) per kW of the installed PV array (Ppv rated), and is expressed as

    Ya Edc Ppvrated

    (5)

    The final yield (Yf) of the PV system is the energy output of

    Fig 3: I-V and P-V curve of the PV module at 1kW/m2 and 25 ºC

    the PV generator per kW of the installed capacity of the PV array (Ppv rated). The final yield is represented as:

    Yf

    (6)

    Eac Ppvrated

    The system losses are the result of the inverter and is given as

    :

    Ls Ya Yf

    (7)

    Month

    Jan

    Feb

    Mar

    April

    May

    June

    July

    Aug

    Sept

    Oct

    Nov

    Dec

    Array yield

    (Ya)

    2.25

    2.47

    2.65

    2.578

    2.303

    1.90

    1.82

    1.96

    1.933

    2.29

    2.37

    2.25

    Final yield (Yf)

    2.14

    2.35

    2.52

    2.449

    2.188

    1.81

    1.86

    1.73

    1.836

    2.18

    2.26

    2.145

    System loss(Ls)

    0.112

    0.123

    0.132

    0.128

    0.115

    0.095

    0.091

    0.098

    0.096

    0.114

    0.118

    0.112

    Table 3: Monthly average array yield, final yield and system losses in kWh/kWp/day

    0.75

    0.70

    0.65

    Performance Ratio (PR)

    0.60

    0.55

    0.50

    0.45

    0.40

    0.35

    0.30

    0.25

    PR

    1 2 3 4 5 6 7 8 9 10 11 12

    Month of year

    figure it is evident that the performance of the PV panel increases for the months of April to September, while for the rest of the year it is low despite having sufficient yield in PV power.

  4. CONCLUSIONS

The analysis of the selected site of Assam Engineering College shows that there is potential for harnessing solar energy through PV installation. The results of the PV potential assessment using PV indices shows that the highest array yield is 2.65 kWh/kWp/day for the month of March with a lowest value of 1.82 kW/kWp/day for July, with an average value of 2.232 kW/kWp/day throughout the year. The performance ratio (PR) indicates that the system will have highest performance for the month of July (68.8% utilization) with an annual average of 46.47 %. Taking into consideration the fact that no tracking algorithm exist, the results of the assessment show that the site can be utilized to set up a PV generation system. More significant is the knowledge that the

Figure 5 : Performance ratio (PR) variation for the year at AEC

The reference yield (Yr) is defined as the total daily in-plane solar irradiation Ht (kWh/m2/day) divided by the array reference in-plane irradiance at STC (Gref =1 kW/m2). The equation representing Yris given as:

site will perform better during the months of June, July and August as during this period the institution sees shortage of power supply to keep up with the load demand.

REFERENCES

Yr

(8)

Ht Gref

  1. M.A. Eltawil, Z. Zhao MPPT techniques for photovoltaic applications,

    Renewable and Sustainable Energy Reviews 25, (2013), pp 793-813

  2. S. Sivasubramaniam, A. Faramus, R.D. Tilley and M.M. Alkaisi

    In order to evaluate the system performance the average value of monthly solar radiation and temperature are taken as input to the PV model developed in MATLAB/SIMULINK. The model output is the average PV power output from the system. The available power at the output of the converter is the product of the PV power and converter efficiency. And the difference in these two quantities gives the system loss. The results for the year are recorded in the table 3. The recorded data shows variation in the available PV power potential

    throughout the year. The array yield increases from a value of

    2.25 kW/kWp/day in January to 2.65 kW/kWp/day in March, which then decreases in generation capacity from May to September (2.303 kW/kWp/day -1.933 kW/kWp/day) and then shows increased trends towards the end of the year. This is due to the fact that during the months of May to late August and early September the site sees the influence of Monsoon and experiences precipitation. The figure 5 shows the variation of performance ratio throughout the year. From the

    (2014), Performance enhancement in silicon solar cell by inverted nanopyramid texturing and silicon quantum dots coating, Journal of Renewable and Sustainable Energy 6, doi 10.1063/1.4828364

  3. http://mnre.gov.in/file-manager/annual-report/2012- 2013/EN/chapter8.html , last accessed on 28th January, 2014.

  4. www.aec.ac.in last accessed on 13th August,2014

  5. http://eosweb.larc.nasa.gov/sse/ last accessed on 13th August,2014

  6. Labed S, Lorenzo E. The impact of solar radiation variability and data discrepancies on the design of PV systems. Renew Energy 2004;29:pp100722.

  7. Kyocera KC120-1 multi-crystalline photovoltaic module datasheet; 2001 (www.kyocerasolar.com/assets/001/5180.pdf ; last accessed on 1stAugust, 2014.

  8. Photovoltaic system performance monitoring-guidelines for measurement, data exchange and analysis, IEC standard 61724; 1998.

  9. Jahn U, Mayer D, Heidenreich M, Dahl R, Castello S, Clavadetscher L, Frölich A, Grimmig B, Nasse W, Sakuta K, Sugiura T, van der Borg N, van Otterdijk K. International EnergyAgency PVPS Task 2: analysis of the operational performance of the IEA database PV systems. In:16th European PV solar energy conference and exhibition, Glasgow, UK; 2000.

Leave a Reply