- Open Access
- Authors : Rajakumar R, Dr Christopher S, Arvinth Kumar P
- Paper ID : IJERTV12IS070079
- Volume & Issue : Volume 12, Issue 07 (July 2023)
- Published (First Online): 30-07-2023
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Thermal Sciences Design, Engineering and Experiments on Solar Water Heaters
Rajakumar R1, Dr Christopher S2,Arvinth kumar P 3
Center for Solar Pumping System,Department of Mechanical Engineering, Veltech Rangarajan Dr Sakunthala R&D Institute of Science and Technology, Avadi,Chennai 600062.TamilNadu,India
ABSTRACT
Solar flat plate collectors are used for producing hot water at an outlet temperature of 800 C by absorbing the solar radiation in the flat plate collector and heating a fixed quantity of water circulated by natural or forced circulation in the solar water heater.The research gaps in this experiment are the operating parameters and conditions that affect the Outlet temperature and the Instantaneous efficiency are not clearly defined.The objective of the research is to to determine the technical problem that affects the oultlet temperature and thermal efficiency of the solar water heater and to improve the performance of the solar heater by solving the technical problem.During the testing of the solar water heater it was found that the circulation was not effective and the overall efficiency was less than the expected output. Then the collector tilt angle was set to latitude angle and the velocity,mass flow rate of water was corrected by revising the layout of the solar Water heater. After correction,it was found the water outlet temperature was 750C and the thermal efficiency was 81 %.
Keywords: Circulation, Efficiency,Latitude, Radiation, Tilt.
INTRODUCTION
In 2017, India installed 36 new industrial solar process heat systems with a total collector area of 15,313 m2.The Country
now has the sixth largest installed capacity for solar thermal in the global market.
LITERATURE REVIEW AND OBJECTIVE
Prasad, Byregowda and Gangawati[1]conducted an experimental study on a water heater with a flat plate collector and a Solar tracking mechanism increasing the systems thermal efficiency by 21%.Basavanna etal[2] analysed a flat plate collector with triangular pipes obtaining an increase in water outflow temperature by 330K.Shelke and Patil[3] analysed the effect of variation in tube shapes for flat plate solar water heater.They compared the outlet temperature between an elliptical tube and a circular tube concluding that elliptical tube gives the maximum outlet temperature of water for the same heat flux and inlet temperature.Prakash vishnuprasad etal[4] showed that the use of special surface coatings improves the optical properties of the collector, the operating temperature and the performance of the system.Sopian etal[5]experimentally studied the performance
of a new design of solar water heater where the collector and storage tank are integrated in one unit.The temperatures registered in the storage tank oscillated between 600C and 630C with a radiation of 700w/m2 and the efficiency of the system was 75% with an ambient temperature of 310C. The ASHRAE standard requires an experimental determination of steady state collector efficiency under prescribed environmental and operating conditions [6] Ozoe etal[7,8] and Alvarado etal[9]among others have shown the changes in flow pattern with the collector inclination with respect to the horizontal postion.Hollands[10] correlation was used to calculate the Nusselt Number for solar water heater.Among theresearch equations, whillier etal have derived an overall heat loss coefficient and experimental generalised correlations as complements to determine the collectors efficiency[11].Cooper etal [12]have given equations to calculate the overall heat transfer coefficient Ut. Prapas[13] underscored the need for optimisation of system performance to the ultimate limit possible and the performance examination from user point of view.Active system whether direct or indirect can be easily retrofitted to already existing Solar water heater because the storage tank can be placed at any place unlike thermosiphon system.Harrison etal[14].The most commonly used method for analysis of solar water heaters is known as tau alpha method which is based on the product of net transmittance and absorptance of absorbing plate of solar water heater. This technique was developed by Holland and Wright in 1983 and described in detail by Duffie and Beckman[15].The correlation for natural convection between plates was given by Holland etal[16].The effect of tilt angle on the solar radiation can be evaluated using the ASHRAE clear sky equation[17].The effect of geometric and operating parameters by CFD method for solar flat plate collectors was given by Malleboyana etal.The effect of nano particles on the performance of solar flat plate collectors was given by Mohammad [18].The effect of volume flow rate on efficiency of solar collector is discussed in shah etal[19]. The flow distribution in flat plate collectors under different conditions were studied by weitbrect v etal[20].The design of absorber plate and the selective coating plays an active role in the performance of solar water heater for absorbing solar radiation, Jyothi etal[21]At present,solar energy utilisation techniques include photovoltaic, photothermal andphotochemical,Liu etal[22].Solar collectors include flat plate ,vacuum type,concentrating type,gao etal[23].Xuan and Li[24]
investigated the convective heat transfer and flow features of nano fluids,effect of volume concentration,convective heat transfer coefficient,friction factor and flow features.
the Collector.As the Water gets heated up, the density of the Water gets decreased and the hot water as a result,rises up through the Collector to the header and then to the Insulated Storage Tank. In the Tank, the top layer of the water will always be hotter than the bottom layer and there will be temperature difference inside the Tank.This Phenomenon is called Stratification,As a result of hot water flow into the Tank,Cold water gets forced to the Collector through the bottom header. Thus the hot Water flows to the storage tank. |
Solar water heater side view |
Thermosiphon Solar Water Heater Storage Sun tank |
swh |
OBJECTIVE
The objective of the Research is to perform Experiments in Solar Water Heater and plot the variation in Water Outlet Temperature and Instant Efficiency w.r.t the Time of the Day.
Thermal Efficiency of Solar Flat Plate Water Collector is given by
= output/input x 100 ——– (1.1)
= / . G =850w/m2.
= . . [1 2] ———(1.2)
1.MATERIAL AND METHODS
Solar water heater front view
Storage reservoir
pump
well
Measurement Equipments;Thermocouple, Pressure gauge,sun shine recorder,pyranometer, Water level Indicator,flow meter,digital thermometer.
The light rays from the sun,as they fall over the flat plate collector penetrate the transparent cover and hit the selectively coated(black body)surface of the Absorber Plate. A part of the Energy falling on the Collector surface is absorbed by the Collector and is then transferred to the Water flowing through the tubes fitted the absorber plate by conduction heat transfer. The remaining part of the radiation is lost to the atmosphere by Convection and Re-radiation. The ratio of the Energy Collected by the Collector Plate to the Energy Incident On the Collector Surface is defined as the Efficiency of
Solar Water Collector Tilt angle;
1.360 before Improvement.
2.220 after Improvement.
Tilt angle = Latitude angle of place.
2.0 CALCULATION OF THE INSTANTANEOUS EFFICIENCY OF OLAR FLAT PLATE COLLECTORS
Instantaneous Solar Efficiency is given by
= / . —-(2.1)
= . . [1 2] —–(2.2)
m =165Kg/hr
= 0.046Kg/Sec.
= 0.046 x 4.186 x(60-30)
—————————— x100
0.85 x 2 x 4
Solar constant G=0.850KW/m2
= 85.0%
Instantaneous Efficiency vs Time
80y = -0.6071×2 + 14.421x – 18.914
3.0 RESULTS AND DISCUSSION
TABLE 3.1
TEMPERATURE VS TIME;
Instant Efficiency in %
70 R² = 0.7364
60
50
40
30
20
10
0
y = -0.5541×2 + 20.565x – 125.85 R² = 0.9562
Time(x) |
8 |
9 |
10 |
11 |
12 |
13. |
14 |
15 |
16. |
T10 |
31 |
32 |
34 |
49 |
55 |
58 |
60 |
71 |
71 |
T11 |
31 |
32 |
34 |
50 |
56 |
58 |
62 |
73 |
71 |
T12 |
32 |
33 |
36 |
52 |
57 |
59 |
64 |
75 |
71 |
0 5 10 15 20
Time in hrs
90
80
70
60
50
40
30
20
10
0
Temperature y vs time x
y = -0.3149×2 + 13.108x – 54.184 R² = 0.9877
y = 0.25×2 – 1.9167x + 31.667
R² = 0.9938
0
temperature deg c
Chart 3.1
Chart 3.2
1000
900
solar radiation w/m2.
800
700
600
500
400
300
200
100
Series 1 -Actual Series 2-Predicted
0
Series1 Series2
Linear (Series1) Poly. (Series1)
Linear (Series2) Poly. (Series2)
Solar radiation vs Time of day
y = 63.617x – 136.51
R² = 0.9928
0 5 10 15 20
Time of the day
5
10
Series1
15
Series2
20
Linear (Series1) time in hrsPoly. (Series1)
Linear (Series2)
Poly. (Series2)
CHART 3.3
Table2.0 Efficiency vs Time.
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
9.3 4 |
11.9 7 |
16.5 8 |
33. 4 |
47.1 4 |
53. 0 |
60. 5 |
77. 8 |
79. 3 |
75. 0 |
Cross Section of the Water Storage Tank of Solar Heater.fig1.0
Insulation -Glass wool
Front view side view
…
Hot water 750 C
Cold water 300C
Dia 850mm
Shell =steel /casing -Al
Fig 2.0Photograph of the Experimental Set Up. 4.0EXPERIMENTS AND RESULTS
The storage tank is connected to the flat plate collectors through Header pipes at inlet to collector at the bottom and the Outlet of the solar flat plate collectors to connected to the upper
Header and connected to the storage vessel. Cold water enter the solar flat plate heater and by density difference and heat Given by the absorber plate gets heated up and rises up to the Upper portion of the tank by thermosyphon technique.
Temp vs Height of water
80
70 y = 0.0755×2 + 0.7146x + 32.64
60 R² = 0.9312
Temperature
50
40
30
20
10
0
0 5 10 15 20
Height
1.3 m xDia 0.850m
-
Water Oultlet Temperature vs Time of the Day.
After measuring the Water Outlet Temperature from the Collector periodically for all the three systems namely 400 LPD,500LPD and 600LPD , It was decided to compare the results obtained with the Theoretical Design Values.Hence in this Chapter, to Start with for each System, the Predicted Water Outlet Temperature and Instantaneous Efficiency are first evaluated before going in the Comparision with the given values.
chart 3.1 and chart 3.5 gives the variation in Water Outlet Temperature with Time of the Day.For 400 LPD System, a Maximum Temperature of 57 deg C will be obtained around noon if the water enters at 32 deg C.
The following observations are made w.r.t to the charts plotted for Temperature Vs Time.
1.A Maximum Temperature Rise is Obtained around Noon. 2.Temperature Rise is Maximum for Lower System Capacity names 400LPD and lower for Higher System Capacity namely 600LPD.
3.The Temperature Rise becomes lesser and lesser as the Inlet Water Temperature to the Collector Increases.This is due to the fact that higher the Temperature, Higher will be the Loss. 4.The variation of solar radiation w.r.t the time of the day
Is given in chart 3.3 and the max radiation is 800W/m2.
-
The Formula used for predicting the Instantaneous Efficiencyis given in topic 2.0.
CHART 3.4
400 LPD |
500LPD |
600LPD |
|
Inclination of Solar Flat Plate Collector |
220 |
220 |
220 |
Horizontal Distance of Storage tank from Solar water heater(.mm) |
577 |
585 |
585 |
Vertical Distance of Storage tank from Solar water heater.(mm) |
233 |
236 |
236 |
Velocity of water flow to Solar water Heater(m/sec) |
0.098 |
0.097 |
0.0986 |
4.2 Instant Efficiency vs Time of the Day.
The variation in Efficiency vs Time is plotted in Chart 3.2.
It is observed from the chart that maximum efficiency occurs around 2 o clock in the afternoon.This can be attributed to the fact that around 2 o clock,the water will be at high temperature
Forcing the other liquid to flow.Hence it is possible to achieve a better flow rate during noon hours and inturn a better efficiency.
-
Calculations for the Solar Water Heater before Improvement.
Diameter of the riser tubes(mm)=12.7 mm Material of the riser tubes= Copper.
Density of Water()= 1000kg/m3. Velocity of Water = 0.12m/sec.
Dynamic Viscosity of Water() =8.9 x 10-4 N.S/m2.
= ( )/.
Substituting the values,
Re= 2597.
Re> 2000 ,So the Flow is Turbulent.
-
Flow Calculations for the Solar Water Heater After Improvement.
Diameter of the riser tubes(mm)=12.7 mm Material of the riser tubes= Copper.
Density of Water()= 1000kg/m3. Velocity of Water = 0.15m/sec.
Dynamic Viscosity of Water() =8.9 x 10-4 N.S/m2.
= ( )/.
Substituting the values,
Re= 2796.
Re> 2000 ,So the Flow is Turbulent.
-
Layout of the Solar Water Heater Before Improvement.
-
Layout of the Solar Water Heater After Improvement.
The angle of Inclination of the solar water heater was 360 before Improvement and the tilt angle is 220 after Improvement.
Temp vs Time
40
35
Temperature
30
25 y = -0.295×2 + 7.3372x – 7.6852
R² = 0.9882
400 LPD
500LPD
600LPD
Inclination of Solar Flat Plate Collector
360
360
360
Horizontal Distance of Storage tank from Solar water heater(.mm)
793
696
793
Vertical Distance of Storage tank from Solar water heaer.(mm)
576
506
576
Velocity of water flow to Solar water Heater(m/sec)
0.091
0.093
0.094
20
15
10
5
0
0 5 10 15 20
Time
Series1 Series2
Series3 Linear (Series3) Poly. (Series3)
Chart 3.5
. With reference to the chart,the maximum temperature is 38 deg c before improvement and the maximum temperature of 75 degc was achieved after the tilt angle and layout is revised.
-
Performance of the Solar Water Heater before Improvement.
1.Absorber Plate2m x 1m Copper sheet. Black painted. 2.Headers= 1Cu pipe.
3.Risers=
½Cu tubes. 4.Insulation Glass wool.
C
copper tubes
Instant 25
Efficiency(%)
Subject
400LPD
500LPD
600LPD
Water Outlet Temperature (Deg C)
58
62
63
Water Inlet Temperature (Deg C)
32
32
32
56
54
W W
ater inlet =30degC.
ater outlet=75degC.
-
Performance of the Solar Water Heater after Improvement.
Subject |
400LPD |
500LPD |
600LPD |
Water Outlet Temperature (Deg C) |
78 |
75 |
72 |
Water Inlet Temperature (Deg C) |
32 |
32 |
32 |
Instant Efficiency(%) |
78 |
77.8 |
81.64 |
Fig 3.0Cross section of a solar flat water heater
i c
Outlet header
Inlet header Dia 1
Cu tubes are welded to the absorber plate.
Absorber sheet
5.0 CONCLUSION
It can be concluded from the studies conducted that by taking proper care in the Installation of collector tank, collector tilt angle and piping system, it is possible to achieve a high efficiency. Our Experience suggests that though the collector and storage tank are properly designed,due to lack of proper sizing and level of pipes in the system, a poor efficiency was
noticed.However this problem was removed when the pipes are sized and located properly.Hence it is suggested that due mportance shall be given not only to the basic design of the ollector system but also to the Installation.
ACKNOWLEDGEMENTS
1..Anna University,Chennai 25.
2.Veltech University,Chennai 62. 3.BHEL Hospitals, Trichy 4.NITTR Chennai.
5..TEDA,Chennai.
6.CAD CenterChennai 54. 7.www.ieindia.org NOMENCLATURE
g Ac |
Acceleration due to gravity Area of solar collector |
[m/sec2] [m2] |
I |
Solar constant |
[w/m2] |
T |
Temperature |
[Deg C] |
Absorptivity |
||
Density of water |
[kg/m3] | |
Rotor rotational speed |
[rad/s] | |
Q |
Heat Flow |
[KW] |
G Cp Tfi Tfo UL |
Solar Constant. Specific heat of water Water inlet temperature. Water outlet temperature. Transmissivity. Overall heat loss Coefficient. |
[W/m2] [W/m2 oK] [Deg C] [Deg C] [w/m2 0k] |
C |
||
REFERENCES 1.Mauthner,F;Weiss;Spork-Dur,MSolarHeat worldwide; IEA Solar Heating and Cooling Gleisdorf, Austria,2016. 2.https://www.researchgate.net/publication/353549578 _A_Review_of_Solar_Flat_Plate_Thermal_Collector. 3.Selmi etal.(2008)Validation of CFD simulation for flat Plate solar energy collector.Renewable Energy 33,383. 4.American Society of Heating,Refrigerating and Air Conditioning Engineers,inc ANSI/ASHRAE 93- 2010(RA2014),Methods of Testing to Determine the Thermal Performance of Solar Collectors,ASHRAE,Atlanta,USA 2014. 5.ISO 9806-1 International Standard,Test Methods for Solar Collectors-Part 1;Thermal Performance of Glazed Liquid Heating Collectors Including pressure drop,ISO,Switzerland 1994. 6.https://www.researchgate.net/publication/ 355184395_NON_CONVENTIONAL_ENERGY_ SOURCES_FOR_CONSERVING_THE_NATURAL_ RESOURCES_OF_EARTH.
Anna University,Chennai 600025. |