- Open Access
- Total Downloads : 511
- Authors : Muftah H. El-Naas, Sulaiman Al-Zuhair, Amal Al-Lobaney
- Paper ID : IJERTV2IS100471
- Volume & Issue : Volume 02, Issue 10 (October 2013)
- Published (First Online): 23-10-2013
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Treatment of Petroleum Refinery Wastewater by Continuous Electrocoagulation
Muftah H. El-Naas, Sulaiman Al-Zuhair, Amal Al-Lobaney
Chemical and Petroleum Engineering Department, UAE University
Abstract
Electrocoagulation is a process that involves dissolution of a metal anode with simultaneous formation of hydroxyl ions and hydrogen gas at the cathode. It has recently attracted the attention of many industries as a potential technique for the treatment and purification of several types of highly contaminated wastewater. In this study, electrocoagulation has been evaluated as a treatment process for the reduction of high concentrations of COD in petroleum refinery wastewater. Experiments were carried out in the continuous mode using an electrocoagulation reactor with aluminum electrodes. The effects of key operating parameters such current density, pH, initial COD content and the inlet flow rate were investigated. The reduction of COD content was significantly improved by increasing the current density and reducing the feed flow rate. The reactor performance was optimized at a neutral pH, in the range of 6-8, and ambient temperature of about 25 oC. The results demonstrated the technical feasibly of
electrocoagulation for the pretreatment of heavily contaminated industrial wastewater.
Keywords:COD reduction; aluminum electrodes; Petroleum refinery wastewater; Current density; Pretreatment
-
Introduction
The treatment of wastewater, generated by the industry, represents a significant environmental pollution challenge, because of its large quantity and the diversity of pollutants present [1]. One of these industries is the petroleum refinery, which produces considerable amounts of wastewater with high concentrations of aliphatic and aromatic hydrocarbon that usually have detrimental and harmful effects on plant and aquatic life, as well as the surface and ground water sources [2]. Therefore, effective and
feasible methods for treating petroleum refinery wastewater are needed. These methods may include biodegradation, ultrafiltration, adsorption, coagulantion, and electrochemical processes [2]. Electrochemical techniques such as, electroflotation (EF), electrodecantation (ED), electrocoagulation (EC), and electrokinetic remediation have the advantage of being easily distributed, and require minimum amount and number of chemicals. In recent years, several studies have focused on electrocoagulation, which is an effective process used to treat wastewaters with finely dispersed particles [3]. This technique is robust and compact, and hence has the potential to replace sophisticated processes that require large volumes and/or number of chemicals [4]. Electrocoagulation is a primary technique for treatment of various wastewaters generated by industry, agriculture or urban areas. The technique relies upon the electrochemical dissolution of sacrificial Al or Fe electrodes. The generated cations contribute to the reduction of the stability of suspended entities contained by reducing their zeta potential [5]. In addition, upon formation of hydroxides ions at the cathode, metal ions form complexes with iron or aluminum hydroxides, which are known to be efficient coagulants. Furthermore, the hydrogen bubbles formed at the cathode adsorb the flocs formed by the process, and ensure their flotation, which simplifies their separation from the treated water [5]. The electrocoagulation technique have been considered for the treatment of wastewaters in a very broad range in terms of nature and composition, such as: wastewater from textile industry [1, 5-7], oil suspension [8, 9], petrochemical industry wastewater [2], wastewater containing arsenic [10 ], phenolic compounds [11, 12], heavy metals [13, 14] and Fluorides [15, 16].In spite of the considerable success of electrocoagulation for the treatment of various types of wastewater, its application as a possible technique for the treatment of petroleum refinery wastewater is
rather scarce in the literature. A preliminary evaluation of a batch electrocaogulation reactor proved to be effective for the treatment of refinery wastewater [2]. The main objective of the present study, therefore, is to evaluate the potential of continuous electrocoagulation of refinery wastewater and to examine the effect of different operating parameters on the reactor performance.
-
Experimental Setup
Experiments were carried out in 1500 ml cylindrical reactor (14 cm diameter × 10 cm length). Electrode assembly is the heart of any electrochemical treatment facility. Therefore, appropriate selection of electrode material is very important [17]. The effectiveness of using aluminum, iron and stainless steel electrodes in different cathode and anode arrangement to treat the petroleum refinery wastewater was investigated. The results, presented in the batch study, showed that the aluminum electrode is more capable to treat such wastewater [2]. Therefore, in the present study aluminum electrode was used. The aluminum plates with different effective working areas in the range of 20 50 cm2 were tested. The electrodes of the electrochemical cell were connected to an electrical DC power supply (PE-23005 POPULAR). The distance between the anode and the cathode was kept constant at 7.5 cm.
The wastewater samples were collected from a specified location in the wastewater treatment system of a local petroleum refinery. The samples had a dark green color, a very strong pungent odor and had high concentrations of COD and total phenols. Characteristics of the wastewater samples are presented in Table 1. A 600 ml of the wastewater was treated in batch operation for one hour and then the continuous operation was started by pumping the wastewater to the reactor by a peristaltic pump (GILSON Miniplus 3) with different flow rates in the range of 5 -15 ml/min. The effluent was then sent to a settling tank, which has double the volume capacity of the electrocoagulation reactor. Samples were periodically withdrawn directly from the reactor medium and after the settling tank. The COD of the withdrawn samples was measured using HACH UV spectrophotometer (Model DR-5000). The experimental setup of the continuous electrocoagulation process is shown in Figure 1.
Figure 1. A schematic diagram of the electrochemical apparatus.(1) Feed tank, (2) Feed pump, (3) Magnetic stirrer, (4) Magnetic bar, (5) Anode, (6) Cathode, (7) Electrocoagulation reactor, (8) DC power supply, (9) Settling tank and (10) Product tank
Table 1. Characteristics of wastewater
Parameter
Value
pH
8.3-8.9
Conductivity (mS/cm)
5.2-6.8
Total Suspended Solid (g/l)
0.03-0.04
Total Dissolved Solid (g/l)
3.8-6.2
SO4 (mg/l)
14.5-16
COD (mg/l)
3600- 5300
Total Phenols (mg/l)
160-185
Phenol (mg/l)
11-14
o-Cresol (mg/l)
14-16.5
m,p-Cresol (mg/l)
72-75
N-Hexane (mg/l)
1.8-1.85
-
Results and Discussion
-
Effect of mixing mechanism
The actual residence time in the electrocoagulation reactor must be determined, before the start of the experimental work. Therefore, a residence time distribution (RTD)experiment was carried out by injecting 8.5 ml of NaOH as a pulse into the inlet stream to the reactor and the conductivity of the exit stream was measured with time. The residence time was then determined from dividing the working volume by the volumetric flow rate.The effect of using air bubbling and magnetic stirring as two mixing techniques at two different liquid flow rates is shown in Figure 2. It was found that, at the same inlet flow rate of 10 ml/min, the type of mixing had almost negligible effect on the reactor RTD. At an inlet flow rate of 10 ml/min, the mean residence times using air bubbling and magnetic stirring were 70 and 73.2 min, respectively. The effect of the two types of mixing
techniques, namely air bubbling and magnetic stirrer, on the performance of the EC cell was also evaluated. The COD removal during the continuous operation with a current density of 33 mA/cm2, initial pH = 7.8 and initial temperature = 25°C is shown in Figure 3. The results clearly show that the mixing mechanism
has an insignificant effect on the reduction of COD. However, it was observed that the sludge produced using air mixing settled faster than that produced with the magnetic stirrer. This is due to the enhanced floatation effect by air bubbling, removing the oily component of the wastewater and hence reducing time for settling of the generated sludge. Therefore, in all subsequent experiments, air mixing was selected as the preferable mixing technique.
Flow rate 10ml/min with air mixing Flow rate 10ml/min with stirrer Flow rate 15 ml/min with stirrer
Flow rate 10ml/min with air mixing Flow rate 10ml/min with stirrer Flow rate 15 ml/min with stirrer
0.020
RTD function E(t)
RTD function E(t)
0.015
0.010
0.005
0.000
0 50 100 150 200 250 300 350
Time (min)
Figure 2.RTD function, E(t), with time for different flow rates and types of mixing
Magnatic stirrer mixing Air mixing
Magnatic stirrer mixing Air mixing
100
%COD Reduction
%COD Reduction
80
60
40
20
0
0 1 2 3 4 5 6 7
Time (hr)
Figure 3.Effect of mixing type on the COD removal. Current density = 33 mA/cm2, initial pH= 7.8, initial concentration = 5064 mg/l, initial temperature = 25°C and flow rate = 10 ml/min
-
Effect of current density
It is well-known that current density not only determines the coagulant dosage rate but also the bubble production rate and size and the flocs growth, all of which can influence the treatment efficiency of the electrocoagulation [18-19]. Current density, which is defined as the ratio of applied current over the effective area of the electrode, increases with increasing the applied current and/or decreasing the area.The effect of current density by changing the current while keeping the effective area constant at 50 cm2, on the percentage removal of COD is shown in Figure 4. The results show that the steady state was reached after about 1 hr. This indicates that the system has reached the steady state after the batch period of the experiment, and during the continuous part, the reduction of COD remained constant at the steady state value. Similar behavior was observed in all continuous experiments. It can clearly be seen that the COD reduction enhanced by increasing the current
density. The removal percentage increased from 39% to 57 % by increasing the current from 750 mA (current density =15 mA/cm2) to 2000 mA (current density = 40 mA/cm2). This is expected, as by increasing the current, the anode dissolution rate increases, which in turn increases the concentration of metal ions in the solution, and consequently the pollutants removal rate is enhanced [2]. In addition, an increase in bubble density occurs at high current, which also results in a greater flux and faster removal of pollutants [2, 20].To further understand the effect of current density, the COD removal was tested at different current densities, varied by changing the electrode area, while keeping the applied current constant. It can be seen from Figure 5 that the percentage of COD reduction in this case was not affected. Increasing the electrode area results in reduction in current density, and hence decreases the amount of aluminum hydroxide produced, which should result in lowering the efficiency of COD reduction. However, at the same time this increase in the electrode area increases the overall electrolysis reaction effective area, which has a positive effect on the COD reduction. It seems then that the two opposing factors cancel each other, which results in the insignificant effect of electrode area as shown in Figure 5.
Current = 750 mA Current = 1000 mA
Current = 1500 mA
Current = 2000 mA
Current = 750 mA Current = 1000 mA
Current = 1500 mA
Current = 2000 mA
100
80
temperature caused an increase in the solubility of aluminum hydroxide, which is responsible for removing the colloidal particles, and hence reducing the electrolysis efficiency.
% COD Reduction
% COD Reduction
60
40
20
0
0 2 4 6
Time (hr)
100 60
55
80
% COD Reduction
% COD Reduction
Temperature oC
Temperature oC
50
60 45
40
40 35
%COD Reduction Temperature
%COD Reduction Temperature
30
20
25
Figure 4.Effect of current on the COD removal. Electrode area = 50cm2, initial pH =7.8, ,initial concentration = 5064 mg/l, initial temperature = 25°C and flow rate = 10 ml/min
Electrode area = 10 cm2 Electrode area = 12 cm2 Electrode area = 15 cm2 Electrode area = 20 cm2
Electrode area = 10 cm2 Electrode area = 12 cm2 Electrode area = 15 cm2 Electrode area = 20 cm2
100
% COD Reduction
% COD Reduction
80
60
40
20
0
0 2 4 6
Time (hr)
Figure 5.Effect of electrode area on the COD removal. Current = 600 mA, initial pH =7.8, , initial concentration = 5064 mg/l , initial temperature = 25°C and flow rate = 10 ml/min
-
Effect of temperature
In Figure 4, it was noted that the removal percentage slightly dropped after the batch period. This may be due to the increase in temperature during the electrolysis reaction. To understand this phenomenon, the temperature was monitored throughout the course of the experiment using a current of 2000 mA. It can be seen from Figure 6 that during the batch period of the experiment, the reduction of COD reach 48 % and the temperature increased to reach 42 °C. After about 4 hours of operation, the temperature reached 55 °C and the COD reduction stabilized at 40 %. The increase in
0 20
0 1 2 3 4 5 6 7
Time (hr)
Figure 6.Percentage COD reduction with time. Current = 2000 mA, electrode area = 50 cm2; initial pH =7.8, initial concentration = 5064 mg/l, initial temperature = 25°C and inlet flow rate = 10 ml/min
-
Effect of initial concentration
The initial concentration of COD in the wastewater samples differ from time to time according to disturbances inevitably occurred during the processing. The effect of the initial COD concentration on the percentage reduction of pollutants was determined for two samples collected from the same location, but at different times. Figure 7 shows that the sample with high initial concentration has a lower COD percentage removal. This is due to the fact that the amount of aluminum hydroxide is constant for both cases, which mainly depends on the current density and electrode material, and is independent of the initial concentration of the contaminants in the wastewater. Since the operating conditions of both cases were kept the same, similar amounts of COD were removed, and hence, lower percentage reduction resulted for the higher initial concentration sample.
70
60
%COD Reduction
%COD Reduction
50
40
30
COD = 5064mg/l
COD = 5064mg/l
i
CODi = 3528mg/l
i
CODi = 3528mg/l
20
10
0
0 1 2 3 4 5 6 7
80
pH = 4.2
pH = 7.7
pH = 9.4
pH = 4.2
pH = 7.7
pH = 9.4
% COD Removal
% COD Removal
60
40
20
0
0 1 2 3 4 5 6
Time (hr)
Time (hr)
Figure 7.Effect of initial concentration on the COD removal. Current = 2000 mA, electrode area = 50 cm2, initial pH =7.8, initial temperature = 25°C and flow rate = 10 ml/min.
-
Effect of pH
The value of pH is an important factor that affects the performance of electrochemical and chemical processes. The COD removal was examined at pH values of 4.2, 7.7, and 9.4, adjusted by using HCl or NaOH (0.1 M). Figure 8 shows that the COD removal increases with increasing the pH up to about 8, after which it becomes constant. The drop in the COD reduction at low pH values is in agreement with the amphotric chart of aluminum hydroxide Al(OH)3 that precipitate at pH 6-7 and its solubility increases as the solution becomes more acidic [21-23]. Increasing the precipitation of the Al(OH)3 tends to increase the amount of colloidal particle that is removed with the Al(OH)3. The solutions pH increases during the electrocoagulation experiments due to the cathodic reaction, given in Eq (1), which takes place during electrocoagulation [24]:
Figure 8.Effect of pH on the COD removal. Current density = 33mA/cm2, initial concentration = 5064 mg/l, initial temperature = 25°C and inlet flow rate = 10ml/min
-
Effect of inlet flow rate
-
The removal efficiency of COD was studied using different flow rates in the ranges 515 ml/min at constant current density of 33 mA/cm2. At the same current densities, it was shown that when the flow rate increased, the COD removal efficiency decreased, as shown in Figure 9. The COD reduction efficiency dropped from 48 to 41 % as the flow rate increased from 5 to 15 ml/min. This is expected since higher flow rates lead to lower retention time, and hence the pollutants spent less time in the reactor and its reaction with Al(OH)3 would not be complete. However, this decline in the COD reduction efficiency is not significant given that the flow rate had been tripled.
Inlet flow rate = 5ml/min Inlet flow rate = 10 ml/min Inlet flow rate = 15 ml/min
Inlet flow rate = 5ml/min Inlet flow rate = 10 ml/min Inlet flow rate = 15 ml/min
80
% COD Removal
% COD Removal
60
2H2O 2e H 2OH
2H2O 2e H 2OH
– –
29g0 ( aq)
(1)
40
20
0
0 1 2 3 4 5 6
Time (hr)
Figure 9.Effect of inlet flow rate on the COD removal. Current density = 33 mA/cm2, initial pH
=7.8, initial concentration = 5064 mg/l and initial temperature = 25°C
Conclusions
Electrocoagulation was assessed as a possible technique for the reduction of COD concentration in petroleum refinery wastewater. Wastewater samples containing two different COD concentrations (3628 to 5064 mg/l), collected from a specific location in the wastewater treatment system of a local petroleum refinery, were treated in a continuous electrochemical cell using aluminum electrode. The effects of current density, initial pH and inlet flow rate were investigated. At optimum conditions, it was shown that electrocoagulation can achieve percentage reduction of up to 57 % of the COD.
Acknowledgement
The authors would like to acknowledge the financial support provided by the Japan Cooperation Center, Petroleum (JCCP) and the technical support by JX Nippon Research Institute Co., Ltd (JX-NRI). They would also like to thank the College of Engineering at the UAE University for the continuous support.
References
-
Zodi, S., O. Potier, F. Lapicque and J. Leclerc. "Treatment of the textile wastewaters by electrocoagulation: Effect of operating parameters on the sludge settling characteristics". Separation and Purification Technology 69 (2009) 2936.
-
El-Naas, M. H., S. Al-Zuhair and A. Al-Lobaney. "Assessment of electrocoagulation for the treatment of petroleum refinery wastewater". Journal of Environmental Management 91 (2009) 180-185.
-
Mollah, M.Y.A., P. Morkovsky, J.A.G. Gomes, M. Kesmez, J. Parga and D.L. Cocke. "Fundamentals, present and future perspectives of electrocoagulation". Journal of Hazardous Materials B114 (2004) 199210.
-
Canizares, P., F. MartÃnez, M.A. Rodrigo, C. Jiménez,
C. Sáez and J. Lobato. "Modeling of wastewater electrocoagulation processes Part II: Application to dye-polluted wastewaters and oil-in-water emulsions". Separation and Purification Technology 60 (2008) 147 154.
-
Zongo, I., A.H. Maiga, J. Wéthé, G. Valentin, J. Leclerc, G. Paternotte and F. Lapicque. "Electrocoagulation for the treatment of textile wastewaters with Al or Fe electrodes: Compared variations of COD levels, turbidity and absorbance". Journal of Hazardous Materials 169 (2009) 7076.
-
Alinsafi, A., M. Khemis, M.N. Pons, J.P. Leclerc, A. Yaacoubi, A. Benhammou and A. Nejmeddine. "Electro-coagulation of reactive textile dyes and textile
wastewater". Chemical Engineering and Processing 44 (2005) 461470.
-
Canizares, P., F. MartÃnez, C. Jiménez, C. Sáez and
M.A. Rodrigo. "Coagulation and electrocoagulation of oil-in-water emulsions". Journal of Hazardous Materials 151 (2008) 4451.
-
Can, O.T., M. Kobya, E. Demirbas and M. Bayramoglu. "Treatment of the textile wastewater by combined electrocoagulation". Chemosphere 62 (2006) 181187.
-
Khemis, M., G. Tanguy, J. P. Leclerc, G. Valentin and
F. Lapicque. "Electrocoagulation for the treatment of oil suspension: Relation between the rates of electrode reactions and the efficiency of waste removal". Process Safety and Environmental Protection 83(B1) (2005) 5057.
-
Balasubramanian, N., T. Kojima and C. Srinivasakannan. "Arsenic removal through electrocoagulation: Kinetic and statistical modeling". Chemical Engineering Journal 155 (2009) 76-82.
-
Awad, Y.M. and N.S. Abuzaid. "The influence of residence time on the anodic oxidation of Phenol". Separation and Purification Technology 18 (2000) 227 236.
-
Ugurlu, M., A. Gurses, C. Dogar and M. Yalc-n. "The removal of lignin and phenol from paper mill effluents by Electrocoagulation". Journal of Environmental Management 87 (2008) 420428.
-
Heidmann I. and W. Calmano. "Removal of Zn(II), Cu(II), Ni(II), Ag(I) and Cr(VI) present in aqueous solutions by aluminium electrocoagulation". Journal of Hazardous Materials 152 (2008) 934941.
-
Heidmann I. and W. Calmano. "Removal of Cr(VI) from model wastewaters by electrocoagulation with Fe electrodes". Separation and Purification Technology 61 (2008) 1521.
-
Emamjomeh M.M. and M. Sivakumar. "Fluoride removal by a continuous flow electrocoagulation reactor". Journal of Environmental Management 90 (2009) 12041212.
-
Ghosh, D., C.R. Medhi and M.K. Purkait. "Treatment of fluoride containing drinking water by electrocoagulation using monopolar and bipolar electrode connections". Chemosphere 73 (2008) 1393 1400.
-
Tezcan , U., S. Ugur, A.S. Koparal and U.B Ogutveren. "Electrocoagulation of olive mill wastewaters". Separation and Purification Technology 52 (2006) 136 141.
-
Adhoum N. and L. Monser. "Decolourization and removal of phenolic compounds from olive mill wastewater by electrocoagulation". Chemical Engineering and Processing 43 (2004) 12811287.
-
Kim, T., C. Park, J. Lee, E. Shin and S. Kim. "Pilot scale treatment of textile wastewater by combined process (fluidized biofilm proesschemical coagulationelectrochemical oxidation)". Water Research 36 (2002) 39793988.
-
Yetilmezsoy, K., F. Ilhan, Z. Sapci-Zengin, S. Sakar and M.T. Gonullu. "Decolorization and COD reduction of UASB pretreated poultry manure wastewater by electrocoagulation process: A post-treatment study". Journal of Hazardous Materials 162 (2009) 120132.
-
Bensadok, K., S. Benammar, F. Lapicque and G. Nezzal. "Electrocoagulation of cutting oil emulsions using aluminium plate electrodes". Journal of Hazardous Materials 152 (2008) 423430.
-
Yilmaz, A.E., R. Boncukcuoglu and M.M. Kocakerim. A quantitative comparison between electrocoagulation and chemical coagulation for boron removal from boron-containing solution. Journal of Hazardous Materials 149 (2007) 475481.
-
Tezcan, U., A.S. Koparal and U.B. Ogutveren. Electrocoagulation of vegetable oil refinery wastewater using aluminum electrodes. Journal of Environmental Management 90 (2009) 428e433
-
Alaton, I.A., I. Kabdasl, D. Hanbaba and E. Kuybu. Electrocoagulation of a real reactive dyebath effluent using aluminum and stainless steel electrodes. Journal of Hazardous Materials 150 (2008) 166173.