Treatment of Urban Wastewater by Infiltration Percolation on a Bed of Phosphate
A. Achkoun
Applied Chemistry and Environment Laboratory. University of Science and Technology Settat 577.
Morocco.
R. Cherouaki, J. Naja,
Applied Chemistry and Environment Laboratory. University of Science and Technology Settat 577.
Morocco.
R. MHamdi
Water and Environment Laboratory, Study and Research Center of Mineral Phosphates, Casablanca 25679.
Morocco.
Abstract
The wastewater treatment by infiltration percolation is based on the principle aerobic biological filtration through fines granules. The water is uniformly distributed on the surface of the filter not covered. This study is conducted to demonstrate through a realization of pilot testing the feasibility of the process of infiltration percolation on a bed of phosphate. Therefore, the passage of water, that has undergone one day settling, on a bed of 15 cm thick with a flow rate of
0.5 l / h and a residence time of almost 2 hours, we get an abatement rate satisfying the main indicators of pollution parameters, with a 99% removal of suspended solids, 86% for chemical oxygen demand and 80% of the biological oxygen demand. These results are very interesting for the quality of treated water obtained on a support based on phosphate
Key words: purification, phosphate, wastewater, treatment, infiltration percolation.
-
Introduction
Human activities negatively affect the quality and quantity of existing freshwater resources. Since these resources are limited, it is necessary to preserve and to turn to the use of unconventional resources [1], such as wastewater treatment. Indeed there are several methods of water treatment systems including soil treatment, sand filters [2], systems of infiltration into the soil [3], and intermittent sand filters buried [4].
The infiltration – percolation is a process that involves passing the water slowly through a granular mid with a sequential mode of delivery which alternates feeding periods and resting periods.
Studies of wastewater treatment in the field and laboratory have obtained excellent performance by infiltration [5]. With removal rates of COD, BOD5, TSS, and the virus more than 80% [6-8], this is the result of infiltration, percolation, adsorption [9], chemical reaction, and biological pathway, predation and absorption mechanisms plants or purification process [10, 11]. But in order to improve this performance we opted for use of the natural phosphate by comparing the purifying power of rock phosphate with sand usually used [12].
-
Materials and methods
-
The wastewater
Before using, the pretreated wastewater undergoes a primary settling for 1 day, which can significantly reduce the pollution load.
Pollution parameters that were analyzed are; turbidity using a turbidimeter WTW according to NF T 90-053 standard, suspended solids with a set of vacuum filtration according to NF T 90-105 the chemical oxygen demand (COD) according to NF T 90-101 and this standard with a reactor VELP Scientifica, biological oxygen demand (BOD) using a WTW Oxytop and NF T 90-103. Table 2 summarizes the results of pollution parameters studied:
Settings
Raw water
pH
8,10
Conductivity (µs/cm)
3,39
Turbidity (NTU)
312
MES (mg/l)
776
COD (mg/l)
1034
BOD5 (mg/l)
833
Settings
Raw water
pH
8,10
Conductivity (µs/cm)
3,39
Turbidity (NTU)
312
MES (mg/l)
776
COD (mg/l)
1034
BOD5 (mg/l)
833
Table 1 : Characterization of waste water pretreated
-
Porous media
The materials used in this study are the phosphate of Khouribga city the sand of the Casablanca's sea. To remove impurities, the media were thoroughly washed with distilled water. This process was repeated several times until the removal of impurities [5], and then dried in an oven at 105 °C.
Samples were characterized by X-ray diffraction using a Siemens D500 powder diffractometer. The scanning electron microscope SEM (Zeiss DSM950) was used to determine the morphology of materials. The specific surface area was determined by the BET method using a Micromeritics ASAP2420. The size of the porous media was determined by the laser particle size Cilas. Table 1 summarizes the results:
Table 2 : Characterization of draining materials
Settings
Phosphate
Sand
Dm (Ã…m)
238,30
121,54
D10 (Ã…m)
136,86
5,12
D90 (Ã…m)
358,61
250,02
Uniformity coefficient
2
24
SEM
irregular or rounded grains
irregular or rounded grains
DRX
Fluorapatite, SiO2 ; CaMg(CO3) ; CaCO3
SiO2 ; CaMg(CO3) ; CaCO3
Surface area (m2/g)
12,74
1,58
-
Description of the pilot:
The treatment will be made on a glass column with 50 cm of height and 10 cm of diameter, the filter media has a height of 15 cm, it is arranged over 3 cm of gravel, everything is laid on a filter worn by a grid allowing the free flow of the treated water. The column is made up in its end by a funnel with a hose, which has 1cm of diameter through which the water outlet is recovered [13,14]. The filter medium is crowned with a layer of 3 cm of gravel and a canvas in order to ensure the dispersion of the feed water on the entire bed and to avoid the formation of a preferential path [13] (Fig.1). The clarified water is contained in a tank from which it is withdrawn at a rate of 0.5 l/h.
When the pressure drop, turbidity, or both reach their maximum values, the filter was washed in distilled ensuring continuous water supply. Washing was stopped when the turbidity of the inlet water is equal to that of water at the outlet.
Fig 1 : Drawing of the processing pilot
-
-
Results and discussion
-
Hydraulic study
Pressure drop & Turbidity (NTU)
Pressure drop & Turbidity (NTU)
The variation of the pressure drop as a function of time gives a curve with a slight curve upwards; this is explained by the fact that the elimination of a portion of the impurities takes place in depth [15].
Turbidity (NTU)
Pressure drop
Turbidity (NTU)
Pressure drop
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
0 100 200 300 400 500 600 700
Time (min)
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
0 100 200 300 400 500 600 700
Time (min)
Fig 2 : Variation of the pressure loss and turbidity
Depending on turbidity: the plateau level and duration of the period of use of the filter depends on: Low resistance of the flock; poor settling;increase the surface charge and increasing the thickness of the filter medium [15].
-
Pollution parameters
pH :
The pH of the medium is one of the major parameters that control the retention of inorganic substances such as heavy metals, nitrate and orthophosphate [16].
Table 3 : Variation of pH
Day
Phosphate
Sand
1st
7,57
7,59
2nd
7,79
7,73
3rd
7,56
7,38
4th
7,62
7,56
5th
7,84
7,74
The increase of pH in the treated water is the result of the reduction of aerobic decomposition of organic matter along the filter bed, and the accumulation of ammonia in the reaction column to the result of nitrification. [17]
Conductivity
The high conductivity of the pretreated wastewater indicates a high mineralization (3.39 mS / cm) and provides information on the salinity.
Table 4 : Variation of conductivity
Day
Phosphate
Sand
1st
1581
1850
2nd
2390
2430
3rd
2410
2480
4th
2480
2470
5th
2540
2480
These results can be explained by the rejection of highly mineralized industrial wastewater directly into the sewer system [18].
Turbidity
The primary settling of the pretreated wastewater for 2 days removed 62% of the colloidal material and 68% of suspended solids.
Fig 3 : Variation of turbidity
The average turbidity of the settled wastewater is
312 NTU. But it decreases significantly to 2.02 NTU for treated water by phosphate and 9.53 NTU
for the treated water by sand. This decrease is explained by the fact that smaller particles are retained by blockages between the pores, interception and fixing grains, or chemical interaction of Van der Waals type [17].
Suspended solids
The average content of suspended solids in wastewater is 776 mg/l, when the water settled has an average of 592 mg/l. In addition, the content of suspended solids decreases significantly in the treated water to 24 mg/l NTU for treated water by phosphate and 82 mg/l for the treated water by sand.
Fig 4 : Variation of suspended solids
Theories applied to granular materials show that sedimentation is the preferred disposal mechanism of suspended particles. The coarse suspended solids are retained on the filter surface by mechanical action. The finest particles are retained by the pores between blocks, interception and fixing the grains, or chemical interaction of Van der Waals type [17].
Chemical oxygen demand
The concentration average of COD in the input of the filtration system is 1034 mg/l, while the concentrations recorded at the output are approximately 254 mg/l for water treated by a bed of sand and 103 mg/l for water treated by a bed of phosphate.
Fig 5 : Variation of COD
This sharp reduction in COD could be the result of physical retention of organic matter in the wastewater through the filter and its oxidation by biological processes associated with the bacterial flora [19].
Biological oxygen demand
The average of BOD5 concentration in decanted wastewater, used to the input of the infiltration system is 833 mg / l.
Fig 6 : Variation of BOD5
The concentration average of BOD5 for treated water by the bed of phosphate is 82 mg/l. This means that 81% of the biodegradable organic material is removed.
This could be explained by better oxygenation of the filter allowing aerobic bacteria profiling and therefore ensure a better digestion and oxidation of organic matter [20].
-
-
Conclusion
The analysis of the results indicates a significant elimination of pollution, with both: treatment with a bed of phosphate or a bed of sand.
Moreover, those results reveal a purifying power of phosphate larger than sand with a reduction of 96% for suspended solids, 91% for COD and 81% for BOD5. As for the sand abatement rates are 86% for suspended solids, 77% for COD and 53% for BOD5.
These results are in agreement with those obtained in other studies [21-23], where the removal of COD and SS brushed rate of 80% for sand.
-
Bibliography
-
Kivaisi AK, The potential for constructed wetlands for wastewater treatment and reuse in developing countries: a review. Ecol. Eng. 16, 2001, pp. 545-560
-
Bhagat, R.M., Mangotra, M. and Sharma, Pradeep K. Tillage effects on soil physical properties and yield of rainfed rice (Oryza sativa L.). J. Indian Soc. Soil Sci.47, 1999a, pp. 415-421
-
Jenssen et Siegrist. Evaluation of sampling method effects on volatile organic compound measurements in contaminated soils. Environ. Sci. Technol. 24, 1990, pp. 1387-1392
-
P. Schudel, M. Boller, Onsite wastewater treatment with intermittent buried filters, Wat. Sci. and Tech. 22, 1990, pp. 93-100.
-
A.Tanik, B.Comakolu. Nutrient removal from domestic wastewater by rapid inltration system. Journal of Arid Environments 34, 1996, pp. 379390.
-
M.N. Viswanathan, M.N. Al Senafy, T. Rashid, E. Al- Awadi, K. Al-Fahad. Improvement of tertiary wastewater quality by soil aquifer treatment. Water Sci. Technol. 40, 1999, pp. 159 – 163.
-
T. Reemtsma, R. Gnirb, M. Jekel. Infiltration of combined sewer overflow and tertiary municipal wastewater: an integrated laboratory and field study on nutrients and dissolved organics. Water Res. 34. 2000, pp. 1179 – 1186.
-
D.M. Quanrud, J. Hafer, M.M. Karpiscak, J. Zhang,
K.E. Lansey, R.G. Arnold. Fate of organics during soil- aquifer treatment: sustainability of removals in the field . Water Res. 37. 2003, pp. 3401 – 3411.
-
A. Achkoun, J. Naja, R. MHamdi. Elimination of cationic and anionic dyes by natural phosphate. J. Chem. Chem. Eng. 6, 2012, pp. 721-725.
-
Zhiyin Zhang, Zhongfang Lei, Zhenya Zhang, Norio Sugiura, Xiaotian Xu, Didi Yin. Organics removal of combined wastewater through shallow soil infiltration treatment: A field and laboratory study., Journal of Hazardous Materials 149, 2007. pp. 657665.
-
S. Van Cuyk, R. Siegrist, A. Logan, S. Masson, E. Fischer, L. Figueroa. Hydraulic and purification behaviors and their interactions during wastewater treatment in soil infiltration systems. Water Res. 35. 2001. pp. 953 – 964.
-
A. Achkoun, J. Naja, R. M'hamdi. Use of a bed of phosphate for the treatment of wastewater. Patent No.
MA 32677 B1. 2011
-
Bilali, L., A. Aouad, K. El harfi, M.Benchanâa, A. Mokhlisse. Pyrolysis of Moroccan Youssoufia rock phosphate. J. Anal. Appl. Pyrolysis, 65, 2002 pp.221.
-
Macquarrie DJ, Nazih R, Sebti S. KF/natural phosphate as an efficient catalyst for synthesis of 2'- hydroxychalcones and flavanones. Green Chem , 4, 2002, pp. 56-59
-
R. Desjardins (1990). Water treatment. 2nd revised edition, Paris, 305p.
-
Gupta, V.K., Sharma, S. (2002) Removal of cadmium and zinc from aqueous solutions using red mud. Environmental Science Technology. Volume 36, 3612- 3617
-
A.Schmitt (1989). Modélisation de l'épuration par l'infiltration.Thése en Mécanique, Génie mécanique et
Génie Civil. université des sciences du Languedoc, Monpellier II, 261 p.
-
R. Bremond, R. (1973) Vuichard Settings, water quality, Department of Conservation and Environment,
SPEPE Paris, page 179
-
Spérandio, M., Urbain, V.,Ginestet, P., Audi, M.J., Paul, E. (2001) Application of COD fractionation by a new combined technique: Comparison of various wastewaters and sources of variability. Water Science and Technology , Volume 43, Issue 1, pages 181-190
-
C. Polprasert, N.P. Dan, N. (1996) Thayalahumaran. Application of constructed wetlands to treat some toxic wastewaters under tropical conditions. Wat. Sci. Tech., 34, 165-171.
-
Sun T., He Y., Ou Z., Li P., Chang S., Qi B., Ma X., Qi E., Zhang H., Ren L., Yang G. (1998), Treatment of domestic wastewater by an underground capillary seepage system, Ecological Engineering journal. Volume 11, pages 111119.
-
M.N. Viswanathan, M.N. Al Senafy, T. Rashid, E. Al-Awadi, K. Al-Fahad (1999), Improvement of tertiarywastewater quality by soil aquifer treatment, Water Science Technology. Volume 40, pages 159163.
-
Reemtsma T., Gnirb R., Jekel M. (2000), Infiltration of combined sewer overflow and tertiary municipal wastewater: an integrated laboratory and field study on nutrients and dissolved organics, Water Research. Volume 34, pages 11791186.