- Open Access
- Total Downloads : 118
- Authors : Shilpa Gurunath Kattimani, Kingston Stanely
- Paper ID : IJERTV5IS040614
- Volume & Issue : Volume 05, Issue 04 (April 2016)
- DOI : http://dx.doi.org/10.17577/IJERTV5IS040614
- Published (First Online): 21-04-2016
- ISSN (Online) : 2278-0181
- Publisher Name : IJERT
- License: This work is licensed under a Creative Commons Attribution 4.0 International License
Verification of External Parameters of Residual Current Circuit Breaker to Ensure the Security of Packaging
Shilpa Gurunath Kattimani Karunya University, EIE Department Embedded systems
Coimbatore, India
Mr. P. Kingston Stanely
Karunya University, Assistant Professor, EIE Department
Coimbatore, India
Abstract The paper aims at objective for testing the product before packaging. The product so tested here is the AC type residual current circuit breaker. The testing deals with following parameters barcode, punch mark, toggle, locking clip and logo of the company. This testing in the industrial application is very essential to reduce risk of packaging the vague products.
KeywordsBarcode,Punch Mark, Clip Presence,Switch And Logo
-
INTRODUCTION
The project deals with testing of residual current device before packaging of the product. It aims at checking the parameters like barcode, punch mark, clip presence, printing, and switch. Image processing is the major role in this process. It is used in industrial applications such as manufacturing industries.
Product testing seeks to ensure that consumers can understand which products is the best value. Product testing is a strategy to increase consumer protection. The process of product testing was the beginning of the modern consumer.
Product testing is accomplished by a testing department, an independent test plant, a government plant, etc. Often an existing test method is used as a basis for testing. As with growing technology engineers develop various kinds of test methods. These testing method subjects secure production.
Product testing have a variety of purposes, such as:
To verify whether the regulations and specifications of the contract are met . To determine the new product establishment on the track. Provide conceptual algorithm for the newer idea. Provide standard data for scientific, engineering, and ensure quality assurance functions. Provide a fundamentals for technical communication. Provide reports in evidence of legal proceedings . Help solve problems with current product. Help identify potential cost savings in products.
-
SCOPE
Barcode quality is more important today and forever. In the early days of retail scanning, a bad barcode was an inconvenience. Today a low standard barcode can be a huge liability. Barcode quality includes the quality of the printed barcode image and the encoded data in the barcode. You cannot rely on just a verifier to manage barcode quality risk.
Barcode Verification is the most easy way to ensure that you are printing good barcodes. Bar Codes are the cheapest and authentic way of entering data. Barcode attestation is the best way to ensure 100% scan ability. Clip presence for the product ensures that the product is the first time use and is the seal given by the company. It is the locking the product by the clip.
This project enables the device to be tested for the packing of the residual current device. These tests are very important according to the credentials of the industry.
-
RESIDUAL CURRENT CIRCUIT BREAKER An Residual current circuit breaker, or residual current
device, is a life-saving device which is designed to prevent from getting a deadly electric shock if touched something live, such as a bare wire. It can also provide some protection against electrical fires. There are three types of residual circuit breaker devices
Type AC: RCD for which tripping is protected from residual sinusoidal alternating currents.
Type A: RCD for which tripping is protected from AC, for residual pulsating direct current, with or without phase-angle control, independent of the polarity.
Type B: RCD for which tripping is protected as for type A, for residual sinusoidal currents up to 1 kHz, for residual sinusoidal currents superposed by a even direct current, for which results from rectifying circuit three-pulse star analogy or six-pulse bridge analogy, two-pulse bridge analogy line-to- line with or without phase-angle control, independently of the polarity.
By definition, AC current constitutes of positive and negative half cycles with respect to zero reference point, and an AC fault current flows towards earth at any point during either half cycle. An AC Type RCD will only trip in responds to either of half cycles of the AC earth fault current, whereas an A Type RCD will responds to both the half cycles.
IV APPLICATION OF RESIDUAL CURRENT
DEVICE
RCDs are intended to provide protection against electric shock, which can result from a person touching an exposed live conductor (Direct Contact) or touching exposed metalwork which has a dangerous touch voltage (Indirect Contact).
According to IEC 60479, two key levels of electric current need to be considered with regard to shock protection.
V BLOCK DIAGRAM
-
Imaging:
Fig 2: Residual current circuit breaker device
VI IMAGING PROCESSING
Fig 1: Block diagram
-
Employment login:
In this step the operator will login using the user name and password. As the operator logins, and clicks the ok button, there appears the window where the operator as to enter the details of the product.Ex: reference id, barcode, sensitivity etc
-
Image Capture:
After login step the operator places the product on the conveyor belt it moves towards the lab view vision module to capture the image.
-
Front Image:
The front image consists of toggle detection and printing check of the product. Here toggle refers to on/off button or switch of the residual current device. This should be always off during testing and packaging of the product. Printing check refers to checking the logo of the company.
-
Back Image:
The back image consists of barcode, punch mark and clip presence.
-
Result:
The result of front image and the back image are monitored for comparison with the lab view database which is already stored the pc. The result is displayed on the screen.
The image of the product is captured as front image and back image. The front area of the image consists of logo of the company, the switch. The back area of the image consists of barcode, punch mark, locking clip. Since the obtained image consists of noise factors and also having low intensity and low contrast. The obtained image has to be processed with image enhancements techniques to reduce noise factor, increase the intensity and contrast of an image
Consider an image of the product whose resolution is 256X256 which is an RGB image. The image in G-plane is used. Because in R-plane the intensity is too high, where the image is too bright. In the B-plane the image is more dark so we consider the image in G-plane where the intensity and contrast are balanced.
Fig 3: Image of a switch/toggle
-
Filtering:
Fig 4: Green plane image of switch/toggle
Fig 6: output for logo
-
To determine the clip presence:
Area is calculated, if the area of that particular region is greater than the specified which means that the clip is present. Consider that the clip area is 1000 then when the image is captured, the captured area for the clip, Area>1000 which indicates that the clip is present. Else the clip is absent.
Filtering is the process of improving the visual impact of the information content in an image. The main objective of filtering is to removal of the noise and blurring of an image. We are using median filtering. Median filtering allows the preservation of image features an removal of impulsive noise. In this filtering the input pixel is replaced by median of pixels contained in the window around the pixel. v(m,n)=median{y(m-k,n-l),(k,l)=W}
-
Intensity Enhancement:
The intensity of the image is increased. Brighter image appears to be brighter. Less bright image appears to be bright.
Fig 5: Intensity enhanced image
-
Contrast Enhancement:
The technique for improving image contrast is among the most widely used in image enhancement processes. To produce an image with optimum contrast ratio, it is important to use the entire brightness range of the display medium.
VII RESULTS
-
Verification of logo:
Once the image is processed for the above enhancements checks are to be taken .
To determine the logo presence particular area of the image is captured which is stored as test value and logo of the image is stored in the database when both the values are compared it indicates the logo is present .Else the logo is absent.
Fig 7: output for clip pressed
-
To determine the punch mark:
The area of the punch mark is indicated as 1 , when the image is processed for punch mark that area >1 which represents that punch mark found. Else the punch mark not found.
Fig 8: output for punch mark
-
To determine the toggle condition:
To examine toggle to be off condition. The toggle in the off condition is indicated as 1 and the toggle in the on condition is represented as 0, 1. So when the image is processed for toggle, if the image captured is in the off condition then toggle is off. Else the toggle is on, which indicates as error.
Fig 9: output for switch/toggle
-
-
-
To verify the barcode:
For barcode the image is captured, the barcode which is present on the product is compared with reference value stored in the pc. If both matches then barcode is correct. Else incorrect result is indicated.
Fig 10: output for barcode matching REFERENCES
-
The Effect of Earth Fault Current Harmonics on Tripping of Residual Current Devices. International School on Nonsinusoidal Currents and Compensation agów, Poland, 2008
-
High-Frequency Behavior of Residual Current Devices.IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 27, NO. 3, JULY 2012
-
Shock Hazard In The Presence Of Protective Residual current devices. Massimo mitolo, senior member IEEE.
-
Development of a Residual Current Device Based on Analytical and Numerical Analysis of the Sensitivity and Unbalance of Current Transformer. 2010 International Conference on Computer Application and System Modeling (ICCASM 2010).
-
Yan Han ,Chen Ding, Xinli Shou Design & Implementation of an A – Type Residual Current Circuit Breaker IC , IEEE transactions on Leakage Loss, Vol. 11, March 2010
-
Huijuan Yang, Xudong Jiang and Alex C.KotAccurate Localization Of Four Extreme Corners For Barcode Images Captured By Mobile Phones. IEEE 17th September ,pp26-29, 2010
-
"IEC 61008-1", Residual Current Operated Circuit-Breakers Without Integrated Overcurrent Protection for Household and Similar Uses (RCCBs)Part 1: General Rules, 2006
-
E. Ohbuchi, H. Hanaizumi and L. A. Hock, Barcode Readers Using the Camera Device in Mobile Phones, 2004 Int. Conf. on Cyber worlds, pp. 260-265, Nov. 18-20, 2004
-
A. C. Liew, "Nuisance trippings of residual-current circuit breakers or ground fault protectors of power sources connected to computer and electronic loads," Journal of Electric Power Systems Research, vol. 20, no. 1, pp. 23-30, December 1990.
-
BS 4293, Specification for residual current-operated circuit- breakers, British Standardization Institute, 1983
-
A.M. Featherstone and A.S. Sastrosubroto, "An examination of RCD performance during system disturbances (and other relays)," IEE Colloquium on Safeguarding Industrial Plant During Power System Disturbances, London, UK, 4 Dec 1989, pp. 3/1-3/6
-
S. Czapp, "The effect of earth fault current harmonics on tripping of residual current devices," International School on Nonsinusoidal Currents and Compensation, 10-13 June 2008, pp. 1-6
-
Jacques Schonek. "Residual Current Device in LV". Cahier Technique Schneider Electric.2006
-
K.Li,J.X.Qu,J.G.Lu,"Study on intelligent protective relay with discriminating phase and amplitude of residual current", Low Voltage Apparatus, April 2001, NO.4, pp.12-13,47
-
Dawei Yue,Kui Li, Jinli Yuan, Guanying Zhang. "Residual Current Monitoring Based on Devicenet". Proceedings of the 7th World Congress on Intelligent Control and Automation, June 25-27, 2008,
Chongqing, China: 6027-6030
-
S. Czapp "Protection Against Electric Shock Using Residual Current Devices in Circuits with Electronic Equipment", Electronics And Electrical Engineering, 2007,4(76)
-
Bender, "Installation monitoring with residual current monitors",
Technical information, 2004, NO.3, pp.1-8
-
X.K. Fang, et al, "Development of DeviceNet intelligent node", Fifth World Congress on Intelligent Control and Automation.
-
Schneider Electric, Vigirex Technical Aspects, France: 2004.
-
"IEC 60364; 2002-06", Electrical Installations of Buildings
-
M. Mitolo, "Effects of electrical currents and bonding requirements in buildings", Proc. 41st IEEE IAS Annu. Meeting, pp. 1816-1820, 2006
-
"IEC 60479-1; 2005-07", Effects of Current on Human Beings and LivestockPart 1: General Aspects
-
M. Mitolo, "Of electrical distribution systems with multiple grounded neutrals", Proc. IEEE Ind. Commercial Power Syst. Tech. Conf., pp. 1-6, 200
-
E. L. Owen, "Power system grounding Part II: RCD and GFCI", IEEE Ind. Appl. Mag., vol. 2, no. 4, pp. 71-73, 1996